[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-865-2":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":597},{"id":5,"name":6,"category":7,"favorite":8},865,"土建方向-岗位技能","建筑工程",0,2,50,399,[13,34,45,57,69,81,93,105,117,129,141,153,165,177,189,201,213,225,237,249,261,273,285,297,309,318,330,342,354,365,377,388,400,410,422,434,446,455,467,477,486,498,510,521,533,545,557,565,574,585],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},1276146,1,"单选题","下列( )不属于填土工程质量检验标准中的一般项目。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","回填土料",false,{"key":24,"text":25,"correct":22},"B","分层厚度及含水量",{"key":27,"text":28,"correct":22},"C","表面平整度",{"key":30,"text":31,"correct":32},"D","分层压实系数",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":27,"analysis":33},1276147,"下列( )不属于土方开挖工程的质量检验的主控项目。",[38,40,42,43],{"key":20,"text":39,"correct":22},"标高",{"key":24,"text":41,"correct":22},"长度、宽度",{"key":27,"text":28,"correct":32},{"key":30,"text":44,"correct":22},"边坡",{"id":46,"libraryId":5,"type":15,"typeLabel":16,"stem":47,"options":48,"answer":24,"analysis":33},1276148,"基槽开挖后,下列( )不属于应检验的内容。",[49,51,53,55],{"key":20,"text":50,"correct":22},"基坑的位置",{"key":24,"text":52,"correct":32},"基础尺寸",{"key":27,"text":54,"correct":22},"坑底标高",{"key":30,"text":56,"correct":22},"基坑土质",{"id":58,"libraryId":5,"type":15,"typeLabel":16,"stem":59,"options":60,"answer":27,"analysis":33},1276149,"一般项目在验收时,绝大多数抽查的处（件）,其质量指标都必须达到要求,其余20%虽可以超过一定的指标,也是有限的,通常不得超过规定值的50%,即最大偏差不得大于( )倍。",[61,63,65,67],{"key":20,"text":62,"correct":22},"1.2",{"key":24,"text":64,"correct":22},"1.1",{"key":27,"text":66,"correct":32},"1.5",{"key":30,"text":68,"correct":22},"2",{"id":70,"libraryId":5,"type":15,"typeLabel":16,"stem":71,"options":72,"answer":27,"analysis":33},1276150,"分部工程的验收应由( )。",[73,75,77,79],{"key":20,"text":74,"correct":22},"监理单位",{"key":24,"text":76,"correct":22},"建设单位",{"key":27,"text":78,"correct":32},"总监理工程师（建设单位项目负责人）",{"key":30,"text":80,"correct":22},"监理工程师",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":24,"analysis":33},1276151,"检验批的质量应按主控项目和( )验收。",[85,87,89,91],{"key":20,"text":86,"correct":22},"保证项目",{"key":24,"text":88,"correct":32},"一般项目",{"key":27,"text":90,"correct":22},"基本项目",{"key":30,"text":92,"correct":22},"允许偏差项目",{"id":94,"libraryId":5,"type":15,"typeLabel":16,"stem":95,"options":96,"answer":24,"analysis":33},1276152,"单层钢结构分项工程检验批按( )划分。",[97,99,101,103],{"key":20,"text":98,"correct":22},"施工段",{"key":24,"text":100,"correct":32},"变形缝",{"key":27,"text":102,"correct":22},"屋面、墙板、楼面等",{"key":30,"text":104,"correct":22},"楼层",{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":107,"options":108,"answer":27,"analysis":33},1276153,"建筑工程质量验收应划分为单位（子单位）工程、分部（子分部）工程、分项工程和( )。",[109,111,113,115],{"key":20,"text":110,"correct":22},"验收部位",{"key":24,"text":112,"correct":22},"工序",{"key":27,"text":114,"correct":32},"检验批",{"key":30,"text":116,"correct":22},"专业验收",{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":119,"options":120,"answer":20,"analysis":33},1276154,"《建筑节能工程施工质量验收规范》GB50411-2007中,当墙体节能工程的保温层采用预埋或后置锚固件固定时,锚同件数量、位置、锚固深度和拉拔力应符合设计要求。后置锚固件应进行锚固力现场( )试验。",[121,123,125,127],{"key":20,"text":122,"correct":32},"拉拔",{"key":24,"text":124,"correct":22},"强度",{"key":27,"text":126,"correct":22},"抗压",{"key":30,"text":128,"correct":22},"承载",{"id":130,"libraryId":5,"type":15,"typeLabel":16,"stem":131,"options":132,"answer":24,"analysis":33},1276155,"保温浆料应分层施工,每层厚度不宜大于( )。",[133,135,137,139],{"key":20,"text":134,"correct":22},"8mm",{"key":24,"text":136,"correct":32},"lOmm",{"key":27,"text":138,"correct":22},"12mm",{"key":30,"text":140,"correct":22},"14mm",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":20,"analysis":33},1276156,"找平层施工完成后,应及时覆盖浇水养护,养护时间宜为( )。",[145,147,149,151],{"key":20,"text":146,"correct":32},"7～10d",{"key":24,"text":148,"correct":22},"10～14d",{"key":27,"text":150,"correct":22},"14～18d",{"key":30,"text":152,"correct":22},"24～28d",{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":30,"analysis":33},1276157,"《屋面工程质量验收规范》GB50207-2002中,屋面找平层宜设分格缝,并嵌填密封材。分格缝应留设在板端缝处,水泥砂浆或细石混凝土找平层纵横缝的最大间距,不宜大于( )m。",[157,159,161,163],{"key":20,"text":158,"correct":22},"3",{"key":24,"text":160,"correct":22},"4",{"key":27,"text":162,"correct":22},"5",{"key":30,"text":164,"correct":32},"6",{"id":166,"libraryId":5,"type":15,"typeLabel":16,"stem":167,"options":168,"answer":24,"analysis":33},1276158,"《民用建筑设计通则》GB50352-2005中,阳台、外廊、室内回廊、内天井、上人屋面及室外楼梯等临空处应设置防护栏杆,临空高度在24m以下时,栏杆高度不应低于( )m,临空高度在24m及24m以上（包括中高层住宅）时,栏杆高度不应低于( )m。",[169,171,173,175],{"key":20,"text":170,"correct":22},"1.05,1.05",{"key":24,"text":172,"correct":32},"1.05.",{"key":27,"text":174,"correct":22},"1.10,1",{"key":30,"text":176,"correct":22},"1.05,1.15",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":27,"analysis":33},1276159,"《建筑装饰装修工程施工质量验收规范>GB50210-2001中,金属门窗框与墙体之间的缝隙应填嵌饱满并采用( )密封。",[181,183,185,187],{"key":20,"text":182,"correct":22},"水泥砂浆",{"key":24,"text":184,"correct":22},"细石混凝土",{"key":27,"text":186,"correct":32},"密封胶",{"key":30,"text":188,"correct":22},"腻子粉",{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":30,"analysis":33},1276160,"外墙砖勾缝应饱满、密实,勾缝形式常采用的是( )。",[193,195,197,199],{"key":20,"text":194,"correct":22},"平缝",{"key":24,"text":196,"correct":22},"凹缝",{"key":27,"text":198,"correct":22},"斜缝",{"key":30,"text":200,"correct":32},"半圆凹缝",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":20,"analysis":33},1276161,"《建筑防水工程技术规程》DBJ15-19-2006中,外墙找平层施工前,应对墙面进行检查,并按设计要求铺挂加强网。当设计无规定时,应在外墙面混凝土梁、板、柱与砌体之间铺挂加强网,每侧网宽不应小于( )mm。",[205,207,209,211],{"key":20,"text":206,"correct":32},"100～150",{"key":24,"text":208,"correct":22},"50～100",{"key":27,"text":210,"correct":22},"150～200",{"key":30,"text":212,"correct":22},"200～250",{"id":214,"libraryId":5,"type":15,"typeLabel":16,"stem":215,"options":216,"answer":24,"analysis":33},1276162,"《建筑地面工程施工质量验收规范>GB50209-2010中,为防止底层地面沉陷,基土应均匀密实,压实系数应符合设计要求,设计无要求时,不应小于( )。",[217,219,221,223],{"key":20,"text":218,"correct":22},"0.95",{"key":24,"text":220,"correct":32},"0.90",{"key":27,"text":222,"correct":22},"0.85",{"key":30,"text":224,"correct":22},"0.80",{"id":226,"libraryId":5,"type":15,"typeLabel":16,"stem":227,"options":228,"answer":27,"analysis":33},1276163,"厨,卫间周边翻边混凝土应整体浇筑,高度( )mm,混凝土强度等级( )。",[229,231,233,235],{"key":20,"text":230,"correct":22},"≥200,≥C30",{"key":24,"text":232,"correct":22},"≥300,≥C20",{"key":27,"text":234,"correct":32},"≥200,≥C20",{"key":30,"text":236,"correct":22},"≥300,≥C30",{"id":238,"libraryId":5,"type":15,"typeLabel":16,"stem":239,"options":240,"answer":30,"analysis":33},1276164,"大面积水泥、混凝土楼（地）面完成后应留设缩缝,横向缩缝间距按轴线尺寸,纵向缩缝间距( )。",[241,243,245,247],{"key":20,"text":242,"correct":22},"≤3m",{"key":24,"text":244,"correct":22},"≤4m",{"key":27,"text":246,"correct":22},"≤5m",{"key":30,"text":248,"correct":32},"≤6m",{"id":250,"libraryId":5,"type":15,"typeLabel":16,"stem":251,"options":252,"answer":20,"analysis":33},1276165,"《建筑地面工程施工质量验收规范》GB50209-2010中，室内楼（地）面面层与下一层应结合牢固，且应无空鼓和开裂。当出现空鼓时，空鼓面积不应大于( )cm²，且每自然间或标准间不应多于( )处。",[253,255,257,259],{"key":20,"text":254,"correct":32},"400,2",{"key":24,"text":256,"correct":22},"400,1",{"key":27,"text":258,"correct":22},"300,2",{"key":30,"text":260,"correct":22},"300,1",{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":30,"analysis":33},1276166,"《滚轧直螺纹钢筋连接接头》JG163-2004中,钢筋连接完毕后,标准型接头连接套筒外应有外露有效螺纹,且连接套筒单边外露有效螺纹不得超过( ),其他连接形式应符合产品设计要求。",[265,267,269,271],{"key":20,"text":266,"correct":22},"1P",{"key":24,"text":268,"correct":22},"4P",{"key":27,"text":270,"correct":22},"3P",{"key":30,"text":272,"correct":32},"2P",{"id":274,"libraryId":5,"type":15,"typeLabel":16,"stem":275,"options":276,"answer":20,"analysis":33},1276167,"《混凝土结构工程施工质量验收规范（2011年版）>GB50204-2002中,模板及其支架应具有足够的( ),能可靠地承受浇筑混凝土的重量、侧压力以及施工荷载。",[277,279,281,283],{"key":20,"text":278,"correct":32},"承载能力、刚度和稳定性",{"key":24,"text":280,"correct":22},"承载能力、刚度和整体性",{"key":27,"text":282,"correct":22},"传递能力、刚度和稳定性",{"key":30,"text":284,"correct":22},"承载能力、硬度和稳定性",{"id":286,"libraryId":5,"type":15,"typeLabel":16,"stem":287,"options":288,"answer":27,"analysis":33},1276168,"右图中的塑料垫块,主要用在( )部位。",[289,291,293,295],{"key":20,"text":290,"correct":22},"板",{"key":24,"text":292,"correct":22},"梁",{"key":27,"text":294,"correct":32},"柱",{"key":30,"text":296,"correct":22},"垫层",{"id":298,"libraryId":5,"type":15,"typeLabel":16,"stem":299,"options":300,"answer":27,"analysis":33},1276169,"《混凝土结构工程施工质量验收规范（2011年版）》GB50204-2002,底模及其支架拆除时的混凝土强度应符合设计要求;当设计无具体要求时,梁、拱、壳构件跨度小于或等于8m时,混凝土达到设计的混凝土立方体抗压强度标准值的( ),方可拆除。",[301,303,305,307],{"key":20,"text":302,"correct":22},"≥25%",{"key":24,"text":304,"correct":22},"≥50%",{"key":27,"text":306,"correct":32},"≥75%",{"key":30,"text":308,"correct":22},"≥100%",{"id":310,"libraryId":5,"type":15,"typeLabel":16,"stem":311,"options":312,"answer":24,"analysis":33},1276170,"混凝土浇筑时,浇筑柱混凝土高度不应超过( )m,否则应设串筒下料。",[313,315,316,317],{"key":20,"text":314,"correct":22},"1",{"key":24,"text":68,"correct":32},{"key":27,"text":158,"correct":22},{"key":30,"text":160,"correct":22},{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":24,"analysis":33},1276171,"砌体工程施工有①放线、②抄平、③摆砖、④立皮数杆、⑤挂线、⑥砌砖、⑦勾缝、⑧清理,正确顺序为( )。",[322,324,326,328],{"key":20,"text":323,"correct":22},"②→③→①→④→⑤→⑥→⑦→⑧",{"key":24,"text":325,"correct":32},"②→①→③→④→⑤→⑥→⑦→⑧",{"key":27,"text":327,"correct":22},"②→③→①→⑤→④→⑥→⑦→⑧",{"key":30,"text":329,"correct":22},"②→①→③→⑤→④→⑥→⑦→⑧",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":24,"analysis":33},1276172,"砌筑砂浆必须搅拌均匀,一般情况下砂浆应在( )h内用完,气温超过30℃时,必须在2～3h内用完。",[334,336,338,340],{"key":20,"text":335,"correct":22},"1～2",{"key":24,"text":337,"correct":32},"3～4",{"key":27,"text":339,"correct":22},"4～5",{"key":30,"text":341,"correct":22},"5～6",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":24,"analysis":33},1276173,"国家建筑标准设计图集《框架结构填充小型空心砌块体结构构造》02SG614说明，砌筑砂浆强度不应小于( )。",[346,348,350,352],{"key":20,"text":347,"correct":22},"M2.5",{"key":24,"text":349,"correct":32},"M5",{"key":27,"text":351,"correct":22},"M7.5",{"key":30,"text":353,"correct":22},"M10",{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":27,"analysis":33},1276174,"在施工缝处继续浇筑混凝土时,已浇筑的混凝土抗压强度不应小于( )MPa。",[358,360,362,363],{"key":20,"text":359,"correct":22},"0.8",{"key":24,"text":361,"correct":22},"1.0",{"key":27,"text":62,"correct":32},{"key":30,"text":364,"correct":22},"1.4",{"id":366,"libraryId":5,"type":15,"typeLabel":16,"stem":367,"options":368,"answer":24,"analysis":33},1276175,"地下室侧墙水平施工缝设置在距地下室底板的板面( )mm之问。",[369,371,373,375],{"key":20,"text":370,"correct":22},"100～200",{"key":24,"text":372,"correct":32},"300～500",{"key":27,"text":374,"correct":22},"500～700",{"key":30,"text":376,"correct":22},"700～900",{"id":378,"libraryId":5,"type":15,"typeLabel":16,"stem":379,"options":380,"answer":27,"analysis":33},1276176,"抗渗混凝土抗渗等级用符号( )表示。",[381,383,384,386],{"key":20,"text":382,"correct":22},"M",{"key":24,"text":27,"correct":22},{"key":27,"text":385,"correct":32},"P",{"key":30,"text":387,"correct":22},"MU",{"id":389,"libraryId":5,"type":15,"typeLabel":16,"stem":390,"options":391,"answer":27,"analysis":33},1276177,"《地下防水工程质量验收规范》GB50208-2011中,地下工程防水等级有( )级。",[392,394,396,398],{"key":20,"text":393,"correct":22},"二",{"key":24,"text":395,"correct":22},"三",{"key":27,"text":397,"correct":32},"四",{"key":30,"text":399,"correct":22},"五",{"id":401,"libraryId":5,"type":15,"typeLabel":16,"stem":402,"options":403,"answer":24,"analysis":33},1276178,"回填土应由低处开始分层回填、夯实,采用蛙式打夯机夯实,每层厚度不宜大于( )mm。",[404,405,406,408],{"key":20,"text":370,"correct":22},{"key":24,"text":212,"correct":32},{"key":27,"text":407,"correct":22},"250～350",{"key":30,"text":409,"correct":22},"350～450",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":27,"analysis":33},1276179,"《建筑桩基技术规范》JGJ94-2008中,压桩过程中当桩身垂直度偏差大于( )时,应找出原因并设法纠正。",[414,416,418,420],{"key":20,"text":415,"correct":22},"2%",{"key":24,"text":417,"correct":22},"3%",{"key":27,"text":419,"correct":32},"1%",{"key":30,"text":421,"correct":22},"4%",{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":424,"options":425,"answer":20,"analysis":33},1276180,"下列( )不属于混凝土结构工程中的质量通病。",[426,428,430,432],{"key":20,"text":427,"correct":32},"填充墙与梁板接合处开裂",{"key":24,"text":429,"correct":22},"混凝土结构裂缝",{"key":27,"text":431,"correct":22},"模板钢管支撑不当致结构变形",{"key":30,"text":433,"correct":22},"钢筋锚固长度不够",{"id":435,"libraryId":5,"type":15,"typeLabel":16,"stem":436,"options":437,"answer":27,"analysis":33},1276181,"( )是指各类影响工程结构、使用功能和外形观感的常见性质量损伤,犹如“多发病”一样。",[438,440,442,444],{"key":20,"text":439,"correct":22},"工程质量缺陷",{"key":24,"text":441,"correct":22},"工程质量事故",{"key":27,"text":443,"correct":32},"工程质量通病",{"key":30,"text":445,"correct":22},"工程安全事故",{"id":447,"libraryId":5,"type":15,"typeLabel":16,"stem":448,"options":449,"answer":20,"analysis":33},1276182,"对于框架柱纵向受力钢筋接头采用电渣压力焊做法,要求每( )楼层（每一检验批）都要做一次抽样送检,作抗拉、抗弯的力学性能化验,并且按使用的型号、规格分别来做。",[450,452,453,454],{"key":20,"text":451,"correct":32},"一",{"key":24,"text":393,"correct":22},{"key":27,"text":395,"correct":22},{"key":30,"text":397,"correct":22},{"id":456,"libraryId":5,"type":15,"typeLabel":16,"stem":457,"options":458,"answer":30,"analysis":33},1276183,"钢筋骨架和钢筋网片的交叉点焊接宜采用( )。",[459,461,463,465],{"key":20,"text":460,"correct":22},"闪光对焊",{"key":24,"text":462,"correct":22},"电弧焊",{"key":27,"text":464,"correct":22},"电渣压力焊",{"key":30,"text":466,"correct":32},"电阻点焊",{"id":468,"libraryId":5,"type":15,"typeLabel":16,"stem":469,"options":470,"answer":20,"analysis":33},1276184,"图中为钢筋( )连接方法。",[471,473,474,476],{"key":20,"text":472,"correct":32},"直螺纹套筒",{"key":24,"text":460,"correct":22},{"key":27,"text":475,"correct":22},"锥螺纹套筒",{"key":30,"text":464,"correct":22},{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":479,"options":480,"answer":30,"analysis":33},1276185,"下面( )连接,不属于钢筋机械连接。",[481,482,484,485],{"key":20,"text":472,"correct":22},{"key":24,"text":483,"correct":22},"套筒挤压",{"key":27,"text":475,"correct":22},{"key":30,"text":464,"correct":32},{"id":487,"libraryId":5,"type":15,"typeLabel":16,"stem":488,"options":489,"answer":27,"analysis":33},1276186,"钢材同一厂家、同一牌号、同一规格、同一炉罐号、同一交货状态每( )t为一验收批。",[490,492,494,496],{"key":20,"text":491,"correct":22},"20",{"key":24,"text":493,"correct":22},"40",{"key":27,"text":495,"correct":32},"60",{"key":30,"text":497,"correct":22},"80",{"id":499,"libraryId":5,"type":15,"typeLabel":16,"stem":500,"options":501,"answer":20,"analysis":33},1276187,"钢筋的工艺性能表示钢材在各种加工过程中的行为,包括弯曲性能和( )等。",[502,504,506,508],{"key":20,"text":503,"correct":32},"焊接性能",{"key":24,"text":505,"correct":22},"拉伸性能",{"key":27,"text":507,"correct":22},"冲击性能",{"key":30,"text":509,"correct":22},"疲劳性能",{"id":511,"libraryId":5,"type":15,"typeLabel":16,"stem":512,"options":513,"answer":24,"analysis":33},1276188,"《建筑抗震设计规范》GB50011-2010规定,有较高要求的抗震结构适用的钢筋牌号中已有带肋钢筋牌号后加( )的钢筋。",[514,515,517,519],{"key":20,"text":30,"correct":22},{"key":24,"text":516,"correct":32},"E",{"key":27,"text":518,"correct":22},"F",{"key":30,"text":520,"correct":22},"G",{"id":522,"libraryId":5,"type":15,"typeLabel":16,"stem":523,"options":524,"answer":20,"analysis":33},1276189,"砌块按其空心率大小可分为空心砌块和实心砌块两种。空心率小于( )或无孔洞的砌块为实心砌块。",[525,527,529,531],{"key":20,"text":526,"correct":32},"25%",{"key":24,"text":528,"correct":22},"20%",{"key":27,"text":530,"correct":22},"15%",{"key":30,"text":532,"correct":22},"10%",{"id":534,"libraryId":5,"type":15,"typeLabel":16,"stem":535,"options":536,"answer":24,"analysis":33},1276190,"砂浆强度等级是以边长为( )mm的立方体试件,在标准养护条件下,用标准试验方法测得28d龄期的抗压强度值(单位为MPa)确定。",[537,539,541,543],{"key":20,"text":538,"correct":22},"50",{"key":24,"text":540,"correct":32},"70.7",{"key":27,"text":542,"correct":22},"100",{"key":30,"text":544,"correct":22},"150",{"id":546,"libraryId":5,"type":15,"typeLabel":16,"stem":547,"options":548,"answer":30,"analysis":33},1276191,"下面( )不能作为建筑砂浆的胶凝材料。",[549,551,553,555],{"key":20,"text":550,"correct":22},"水泥",{"key":24,"text":552,"correct":22},"石灰",{"key":27,"text":554,"correct":22},"石膏",{"key":30,"text":556,"correct":32},"砂子",{"id":558,"libraryId":5,"type":15,"typeLabel":16,"stem":559,"options":560,"answer":24,"analysis":33},1276192,"混凝土强度用( )符号来表示。",[561,562,563,564],{"key":20,"text":387,"correct":22},{"key":24,"text":27,"correct":32},{"key":27,"text":382,"correct":22},{"key":30,"text":385,"correct":22},{"id":566,"libraryId":5,"type":15,"typeLabel":16,"stem":567,"options":568,"answer":24,"analysis":33},1276193,"按国家标准《普通混凝土力学性能试验方法》GB\u002FT50081-2002,标准混凝土试块为边长是( )mm的立方体试件。",[569,571,572,573],{"key":20,"text":570,"correct":22},"200",{"key":24,"text":544,"correct":32},{"key":27,"text":542,"correct":22},{"key":30,"text":540,"correct":22},{"id":575,"libraryId":5,"type":15,"typeLabel":16,"stem":576,"options":577,"answer":20,"analysis":33},1276194,"砂率是指混凝土中砂的质量占( )质量的百分率。",[578,580,582,584],{"key":20,"text":579,"correct":32},"砂十石",{"key":24,"text":581,"correct":22},"砂",{"key":27,"text":583,"correct":22},"石",{"key":30,"text":550,"correct":22},{"id":586,"libraryId":5,"type":15,"typeLabel":16,"stem":587,"options":588,"answer":30,"analysis":33},1276195,"混凝土和易性是一项综合的技术性质,下面( )不属于和易性范畴之内。",[589,591,593,595],{"key":20,"text":590,"correct":22},"流动性",{"key":24,"text":592,"correct":22},"黏聚性",{"key":27,"text":594,"correct":22},"保水性",{"key":30,"text":596,"correct":32},"安定性",[598,601,604,607,610,613],{"id":15,"name":599,"category":7,"favorite":600},"领导干部任职前廉政法规知识测试题",92,{"id":602,"name":603,"category":7,"favorite":15},595,"建筑结构与设备",{"id":605,"name":606,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":608,"name":609,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":611,"name":612,"category":7,"favorite":8},534,"BIM工程师",{"id":614,"name":612,"category":7,"favorite":8},535]