[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-862-3":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":600},{"id":5,"name":6,"category":7,"favorite":8},862,"设备方向-通用基础","建筑工程",0,3,50,490,[13,34,42,50,62,74,86,98,110,118,130,142,154,166,178,190,202,214,226,238,250,262,274,286,298,310,322,334,349,361,373,385,397,408,420,430,441,452,464,475,483,495,507,519,531,543,555,567,578,590],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},1274932,1,"单选题","屈服现象结束后,材料又恢复了抵抗变形的能力,这时必须重新增加负荷,才能使试件继续变形,这个阶段称作( )。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","弹性阶段",false,{"key":24,"text":25,"correct":22},"B","屈服阶段",{"key":27,"text":28,"correct":29},"C","强化阶段",true,{"key":31,"text":32,"correct":22},"D","颈缩阶段","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},1274933,"( )应力虽不增加,应变却继续增大,出现了较大的塑性变形,这种情况称为材料的屈服。",[38,39,40,41],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":29},{"key":27,"text":28,"correct":22},{"key":31,"text":32,"correct":22},{"id":43,"libraryId":5,"type":15,"typeLabel":16,"stem":44,"options":45,"answer":20,"analysis":33},1274934,"在拉伸的开始阶段试件变形很小,此时若将拉力卸去,试件变形可完全消失并恢复原状,这个阶段称为( )。",[46,47,48,49],{"key":20,"text":21,"correct":29},{"key":24,"text":25,"correct":22},{"key":27,"text":28,"correct":22},{"key":31,"text":32,"correct":22},{"id":51,"libraryId":5,"type":15,"typeLabel":16,"stem":52,"options":53,"answer":24,"analysis":33},1274935,"( )钢是有代表性的低碳钢,它所表现出的力学性能也比较典型。",[54,56,58,60],{"key":20,"text":55,"correct":22},"Q200",{"key":24,"text":57,"correct":29},"Q235",{"key":27,"text":59,"correct":22},"Q250",{"key":31,"text":61,"correct":22},"Q300",{"id":63,"libraryId":5,"type":15,"typeLabel":16,"stem":64,"options":65,"answer":24,"analysis":33},1274936,"在总变形不变的条件下,由于( )影响而使应力随着时间逐渐降低的现象,称为应力松弛。",[66,68,70,72],{"key":20,"text":67,"correct":22},"压力",{"key":24,"text":69,"correct":29},"温度",{"key":27,"text":71,"correct":22},"湿度",{"key":31,"text":73,"correct":22},"蠕变",{"id":75,"libraryId":5,"type":15,"typeLabel":16,"stem":76,"options":77,"answer":27,"analysis":33},1274937,"材料在某一固定应力和( )温度下,随着时间的增长,( )将缓慢增大,这种现象称为蠕变。",[78,80,82,84],{"key":20,"text":79,"correct":22},"不变,弹性变形",{"key":24,"text":81,"correct":22},"可变,弹性变形",{"key":27,"text":83,"correct":29},"不变,塑性变形",{"key":31,"text":85,"correct":22},"可变,塑性变形",{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":31,"analysis":33},1274938,"下面关于截面法求内力的步骤正确的是( )。",[90,92,94,96],{"key":20,"text":91,"correct":22},"截开→平衡→替代",{"key":24,"text":93,"correct":22},"平衡→截开→替代",{"key":27,"text":95,"correct":22},"替代→截开→平衡",{"key":31,"text":97,"correct":29},"截开→替代→平衡",{"id":99,"libraryId":5,"type":15,"typeLabel":16,"stem":100,"options":101,"answer":20,"analysis":33},1274939,"( )是卸去外力后能完全消失的变形。",[102,104,106,108],{"key":20,"text":103,"correct":29},"弹性变形",{"key":24,"text":105,"correct":22},"塑性变形",{"key":27,"text":107,"correct":22},"综合变形",{"key":31,"text":109,"correct":22},"刚性变形",{"id":111,"libraryId":5,"type":15,"typeLabel":16,"stem":112,"options":113,"answer":24,"analysis":33},1274940,"( )是指卸去外力后不能消失而保留下来的变形。",[114,115,116,117],{"key":20,"text":103,"correct":22},{"key":24,"text":105,"correct":29},{"key":27,"text":107,"correct":22},{"key":31,"text":109,"correct":22},{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":27,"analysis":33},1274941,"下列关于变形的叙述,错误的是( )。",[122,124,126,128],{"key":20,"text":123,"correct":22},"物体在外力作用下产生的变形有两种",{"key":24,"text":125,"correct":22},"弹性变形卸去外力后变形可以消失",{"key":27,"text":127,"correct":29},"工程上使用的多数构件可允许产生塑性变形",{"key":31,"text":129,"correct":22},"塑性变形是指卸去外力后变形不能完全消失",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":27,"analysis":33},1274942,"若将作用于物体上一个力,平移到物体上的任意一点而不改变原力对物体的作用效果,则必须要附加一个( )。",[134,136,138,140],{"key":20,"text":135,"correct":22},"力",{"key":24,"text":137,"correct":22},"力偶矩",{"key":27,"text":139,"correct":29},"力偶",{"key":31,"text":141,"correct":22},"力矩",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":31,"analysis":33},1274943,"下列关于力偶的叙述,错误的是( )。",[146,148,150,152],{"key":20,"text":147,"correct":22},"两个力可以组成力偶",{"key":24,"text":149,"correct":22},"等值反向的力能使物体发生转动",{"key":27,"text":151,"correct":22},"力偶能使物体转动",{"key":31,"text":153,"correct":29},"力偶不能单独存在",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":27,"analysis":33},1274944,"下列关于力矩的叙述,错误的是( )。",[158,160,162,164],{"key":20,"text":159,"correct":22},"力对点的矩是一个代数量",{"key":24,"text":161,"correct":22},"力矩大小等于力的大小乘以力臂",{"key":27,"text":163,"correct":29},"力矩正负的确定是:力使物体绕矩心顺时针转动时取正",{"key":31,"text":165,"correct":22},"力矩正负的确定是:力使物体绕矩心逆时针转动时取正",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":27,"analysis":33},1274946,"关于作用力与反作用力的叙述,错误的是( )。",[170,172,174,176],{"key":20,"text":171,"correct":22},"作用力与反作用力总是同时存在的",{"key":24,"text":173,"correct":22},"作用力与反作用力总是大小相等的,且方向相反",{"key":27,"text":175,"correct":29},"作用力和反作用力,都可以单独存在",{"key":31,"text":177,"correct":22},"作用力和反作用力必须同时存在",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":27,"analysis":33},1274947,"使物体处于平衡的充要条件是( )。",[182,184,186,188],{"key":20,"text":183,"correct":22},"两个力的大小相等",{"key":24,"text":185,"correct":22},"两个力的方向相反",{"key":27,"text":187,"correct":29},"两个力的大小相等,方向相反,且在同一直线上",{"key":31,"text":189,"correct":22},"两个力的方向在同一直线上",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":31,"analysis":33},1274948,"下面关于力的合成,叙述错误的是( )。",[194,196,198,200],{"key":20,"text":195,"correct":22},"作用在物体上同一点的两个力,都可以合成为一个力",{"key":24,"text":197,"correct":22},"力的合成可以用平行四边形法则",{"key":27,"text":199,"correct":22},"两个力合成的力的作用点也在该点",{"key":31,"text":201,"correct":29},"两个力合成的力的作用点,不一定在该点",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":24,"analysis":33},1274949,"火灾报警及消防联动系统要由( )验收确认,安全防范系统要由( )验收确认,两者均是一个独立的系统。",[206,208,210,212],{"key":20,"text":207,"correct":22},"公安监管机构,消防监管机构",{"key":24,"text":209,"correct":29},"消防监管机构,公安监管机构",{"key":27,"text":211,"correct":22},"施工单位,消防监管机构",{"key":31,"text":213,"correct":22},"公安监管机构,施工单位",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":24,"analysis":33},1274950,"施工图的种类按文字形式分类,不包括( )。",[218,220,222,224],{"key":20,"text":219,"correct":22},"图纸目录",{"key":24,"text":221,"correct":29},"设备材料清单",{"key":27,"text":223,"correct":22},"施工说明",{"key":31,"text":225,"correct":22},"各类计算书",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":27,"analysis":33},1274951,"正压送风系统的正确启动顺序是( )。",[230,232,234,236],{"key":20,"text":231,"correct":22},"火灾探测器或手动报警信号报警→正压送风机启动→正压送风口打开",{"key":24,"text":233,"correct":22},"正压送风机启动→火灾探测器或手动报警信号报警→正压送风口打开",{"key":27,"text":235,"correct":29},"火灾探测器或手动报警信号报警→正压送风口打开→正压送风机启动",{"key":31,"text":237,"correct":22},"正压送风口打开→正压送风机启动→火灾探测器或手动报警信号报警",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":31,"analysis":33},1274952,"排烟支管上应设有当烟气温度超过( )℃时,能自动关闭的防火阀。",[242,244,246,248],{"key":20,"text":243,"correct":22},"150",{"key":24,"text":245,"correct":22},"200",{"key":27,"text":247,"correct":22},"250",{"key":31,"text":249,"correct":29},"280",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":27,"analysis":33},1274953,"湿式自动喷水灭火系统的喷头安装中,当喷头DN﹤( )mm时,应在干管或配水管上安装过滤器。",[254,256,258,260],{"key":20,"text":255,"correct":22},"5",{"key":24,"text":257,"correct":22},"8",{"key":27,"text":259,"correct":29},"10",{"key":31,"text":261,"correct":22},"12",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":24,"analysis":33},1274954,"水压严密性试验应在水压强度试验和管网冲洗合格后进行。试验压力为( ),稳压( )h,应无泄露才可以。",[266,268,270,272],{"key":20,"text":267,"correct":22},"设计工作压力,12",{"key":24,"text":269,"correct":29},"设计工作压力,24",{"key":27,"text":271,"correct":22},"实际工作压力,12",{"key":31,"text":273,"correct":22},"实际工作压力,24",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":27,"analysis":33},1274955,"下列关于防火调节阀的叙述,错误的是( )。",[278,280,282,284],{"key":20,"text":279,"correct":22},"70℃时自动关闭",{"key":24,"text":281,"correct":22},"可手动关闭",{"key":27,"text":283,"correct":29},"可远程控制",{"key":31,"text":285,"correct":22},"适用于需隔断火源的通风管上",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":20,"analysis":33},1274956,"下列不属于按洒水形式及使用方法来分类闭式洒水喷头的是( )。",[290,292,294,296],{"key":20,"text":291,"correct":29},"倒立型",{"key":24,"text":293,"correct":22},"直立型",{"key":27,"text":295,"correct":22},"下垂型",{"key":31,"text":297,"correct":22},"边墙型",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":27,"analysis":33},1274957,"发生火灾事故时,在死亡的绝大多数人是因为( )。",[302,304,306,308],{"key":20,"text":303,"correct":22},"大火烧死",{"key":24,"text":305,"correct":22},"跳楼而死",{"key":27,"text":307,"correct":29},"吸入毒性气体而死",{"key":31,"text":309,"correct":22},"因人群踩踏而死",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":20,"analysis":33},1274958,"关于室外消火栓系统的选择,( )消火栓适用于气温较高的地方,( )消火栓适用于较寒冷的地区。",[314,316,318,320],{"key":20,"text":315,"correct":29},"地上,地下",{"key":24,"text":317,"correct":22},"地上,地上",{"key":27,"text":319,"correct":22},"地下,地上",{"key":31,"text":321,"correct":22},"地下,地下",{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":27,"analysis":33},1274959,"用声级计测定时,其测定点为房间中心离地面高度( )M处。",[326,328,330,332],{"key":20,"text":327,"correct":22},"0.5",{"key":24,"text":329,"correct":22},"1.0",{"key":27,"text":331,"correct":29},"1.2",{"key":31,"text":333,"correct":22},"1.5",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":24,"analysis":33},1274960,"相邻不同级别洁净室之间和洁净室与非洁净室之间的静压差不应小于( )",[338,340,342,344,346],{"key":20,"text":339,"correct":22},",洁净室与室外的静压差不应小于____Pa",{"key":24,"text":341,"correct":29},"5,5",{"key":27,"text":343,"correct":22},"5,10",{"key":31,"text":345,"correct":22},"10,10",{"key":347,"text":348,"correct":22},"E","10,15",{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":24,"analysis":33},1274961,"孔隙达到一定程度会使导热系数增大,通常把室温下导热系数低于( )W\u002F(m-K)的材料称为绝热材料。",[353,355,357,359],{"key":20,"text":354,"correct":22},"0.1",{"key":24,"text":356,"correct":29},"0.2",{"key":27,"text":358,"correct":22},"0.25",{"key":31,"text":360,"correct":22},"0.4",{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":27,"analysis":33},1274962,"立式水泵宜采用( )隔振器,并要求水泵机组隔振元件支承点应为偶数,且不少于( )个",[365,367,369,371],{"key":20,"text":366,"correct":22},"阻尼弹簧,4",{"key":24,"text":368,"correct":22},"阻尼弹簧,6",{"key":27,"text":370,"correct":29},"橡胶,4",{"key":31,"text":372,"correct":22},"橡胶,6",{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":24,"analysis":33},1274963,"对阀门进行强度试验时,试验压力为公称压力的( )倍,持续时间不少于( )min,阀门壳体、填料应无渗漏。",[377,379,381,383],{"key":20,"text":378,"correct":22},"1.5,3",{"key":24,"text":380,"correct":29},"1.5,5",{"key":27,"text":382,"correct":22},"2,3",{"key":31,"text":384,"correct":22},"2,5",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":20,"analysis":33},1274964,"各类耐压塑料管的强度试验压力为1.5倍( ),严密性试验压力为1.15倍的( )。",[389,391,393,395],{"key":20,"text":390,"correct":29},"工作压力,设计工作压力",{"key":24,"text":392,"correct":22},"工作压力,工作压力",{"key":27,"text":394,"correct":22},"设计工作压力,设计工作压力",{"key":31,"text":396,"correct":22},"设计工作压力,工作压力",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":20,"analysis":33},1274965,"燃油管道系统必须设置可靠的( )装置,其管道法兰应采用镀锌螺栓连接或在法兰处用铜导管线进行跨接,且结合良好。",[401,403,405,407],{"key":20,"text":402,"correct":29},"防静电接地",{"key":24,"text":404,"correct":22},"接地",{"key":27,"text":406,"correct":22},"防雷击",{"key":31,"text":402,"correct":22},{"id":409,"libraryId":5,"type":15,"typeLabel":16,"stem":410,"options":411,"answer":31,"analysis":33},1274966,"( )应垂直安装在便于检修的位置,其排气管的出口应朝向安全地带,排液管应装在泄水管上。",[412,414,416,418],{"key":20,"text":413,"correct":22},"电磁阀",{"key":24,"text":415,"correct":22},"调节阀",{"key":27,"text":417,"correct":22},"热力膨胀阀",{"key":31,"text":419,"correct":29},"安全阀",{"id":421,"libraryId":5,"type":15,"typeLabel":16,"stem":422,"options":423,"answer":24,"analysis":33},1274967,"风机盘管机组安装前宜进行水压检漏试验,试验压力为系统工作压力的( )倍,试验观察时间为( )min,不渗漏为合格。",[424,425,427,428],{"key":20,"text":378,"correct":22},{"key":24,"text":426,"correct":29},"1.5,2",{"key":27,"text":382,"correct":22},{"key":31,"text":429,"correct":22},"2,2",{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":24,"analysis":33},1274968,"风机试运转时,主轴承温升稳定后,连续试运转不少于( )h,停机后应检查管道密封性和叶顶间隙。",[434,436,438,439],{"key":20,"text":435,"correct":22},"3",{"key":24,"text":437,"correct":29},"6",{"key":27,"text":261,"correct":22},{"key":31,"text":440,"correct":22},"24",{"id":442,"libraryId":5,"type":15,"typeLabel":16,"stem":443,"options":444,"answer":20,"analysis":33},1274969,"水平悬吊的主、干管风管长度超过20m的系统,应设置不少于( )个防止风管摆动的固定支架。",[445,447,449,450],{"key":20,"text":446,"correct":29},"1",{"key":24,"text":448,"correct":22},"2",{"key":27,"text":435,"correct":22},{"key":31,"text":451,"correct":22},"4",{"id":453,"libraryId":5,"type":15,"typeLabel":16,"stem":454,"options":455,"answer":20,"analysis":33},1274970,"在风管穿过需要防火的楼板时,需要用钢管,并且钢板厚度不应小于( )mm。",[456,458,460,462],{"key":20,"text":457,"correct":29},"1.6",{"key":24,"text":459,"correct":22},"2.0",{"key":27,"text":461,"correct":22},"2.5",{"key":31,"text":463,"correct":22},"3.0",{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":27,"analysis":33},1274971,"消声弯头的平面边长大于( )mm时,应加吸声导流片。",[468,469,471,473],{"key":20,"text":245,"correct":22},{"key":24,"text":470,"correct":22},"400",{"key":27,"text":472,"correct":29},"800",{"key":31,"text":474,"correct":22},"1000",{"id":476,"libraryId":5,"type":15,"typeLabel":16,"stem":477,"options":478,"answer":24,"analysis":33},1274972,"风管法兰连接时,其连接应牢固,法兰管口平面度的允许偏差为( )mm。",[479,480,481,482],{"key":20,"text":446,"correct":22},{"key":24,"text":448,"correct":29},{"key":27,"text":435,"correct":22},{"key":31,"text":451,"correct":22},{"id":484,"libraryId":5,"type":15,"typeLabel":16,"stem":485,"options":486,"answer":27,"analysis":33},1274973,"中压圆形金属风管的允许漏风量,应为矩形风管规定值的( )。",[487,489,491,493],{"key":20,"text":488,"correct":22},"30%",{"key":24,"text":490,"correct":22},"40%",{"key":27,"text":492,"correct":29},"50%",{"key":31,"text":494,"correct":22},"100%。",{"id":496,"libraryId":5,"type":15,"typeLabel":16,"stem":497,"options":498,"answer":20,"analysis":33},1274974,"以下选项不属于工业工程常用垫料的是( )。",[499,501,503,505],{"key":20,"text":500,"correct":29},"橡胶板",{"key":24,"text":502,"correct":22},"石棉橡胶板",{"key":27,"text":504,"correct":22},"石棉板",{"key":31,"text":506,"correct":22},"软聚氯乙烯板",{"id":508,"libraryId":5,"type":15,"typeLabel":16,"stem":509,"options":510,"answer":24,"analysis":33},1274975,"下面关于风管尺寸标注的叙述,错误的是( )。",[511,513,515,517],{"key":20,"text":512,"correct":22},"圆形风管尺寸以外径Φ标注,单位为mm",{"key":24,"text":514,"correct":29},"风管尺寸标注时,一般要注明壁厚",{"key":27,"text":516,"correct":22},"矩形风管尺寸以AxB表示,A应为该视图投影面的边长尺寸,B应为另一边的边长尺寸",{"key":31,"text":518,"correct":22},"矩形风管尺寸的标注单位是mm",{"id":520,"libraryId":5,"type":15,"typeLabel":16,"stem":521,"options":522,"answer":27,"analysis":33},1274976,"空调设备的布置以机械制图法则用( )进行绘制,但仅为外形轮廓的尺寸。",[523,525,527,529],{"key":20,"text":524,"correct":22},"斜视图",{"key":24,"text":526,"correct":22},"轴测图",{"key":27,"text":528,"correct":29},"三视图",{"key":31,"text":530,"correct":22},"剖面图",{"id":532,"libraryId":5,"type":15,"typeLabel":16,"stem":533,"options":534,"answer":31,"analysis":33},1274977,"下列关于VRV系统叙述错误的是( )。",[535,537,539,541],{"key":20,"text":536,"correct":22},"VRV系统简单,厂方可以供给所有设备和管道配件",{"key":24,"text":538,"correct":22},"其施工工作周期大大减少",{"key":27,"text":540,"correct":22},"各末端装置的冷媒流量能满足负荷要求",{"key":31,"text":542,"correct":29},"但VAV系统会产生冷媒供应不良的现象",{"id":544,"libraryId":5,"type":15,"typeLabel":16,"stem":545,"options":546,"answer":20,"analysis":33},1274978,"( )是可变冷媒流量空调(VRV)系统的关键部分。",[547,549,551,553],{"key":20,"text":548,"correct":29},"风冷式冷凝器和压缩机",{"key":24,"text":550,"correct":22},"室外机",{"key":27,"text":552,"correct":22},"室内机",{"key":31,"text":554,"correct":22},"冷媒管路",{"id":556,"libraryId":5,"type":15,"typeLabel":16,"stem":557,"options":558,"answer":20,"analysis":33},1274979,"( )属于空调系统的附属系统,负责提供空气处理过程中所需的冷量和热量,制冷装置是制冷系统的核心。",[559,561,563,565],{"key":20,"text":560,"correct":29},"冷热源系统",{"key":24,"text":562,"correct":22},"空气处理系统",{"key":27,"text":564,"correct":22},"能量输送分配系统",{"key":31,"text":566,"correct":22},"自动控制系统",{"id":568,"libraryId":5,"type":15,"typeLabel":16,"stem":569,"options":570,"answer":24,"analysis":33},1274980,"空调系统由冷热源系统、空气处理系统、( )和自动控制系统四个子系统组成。",[571,573,574,576],{"key":20,"text":572,"correct":22},"热量输送分配系统",{"key":24,"text":564,"correct":29},{"key":27,"text":575,"correct":22},"通风系统",{"key":31,"text":577,"correct":22},"排烟系统",{"id":579,"libraryId":5,"type":15,"typeLabel":16,"stem":580,"options":581,"answer":27,"analysis":33},1274981,"下面不属于防雷接地装置外观检查的是( )。",[582,584,586,588],{"key":20,"text":583,"correct":22},"检查装置安装的完整性和连续性,连接应牢固、可靠",{"key":24,"text":585,"correct":22},"螺栓连接应有弹簧垫圈,焊接连接其搭接长度应符合要求",{"key":27,"text":587,"correct":29},"接地线可以直接穿过建筑物楼墙板,无需其他附属措施",{"key":31,"text":589,"correct":22},"接地线的规格应符合要求,接地线的色标应符合要求",{"id":591,"libraryId":5,"type":15,"typeLabel":16,"stem":592,"options":593,"answer":31,"analysis":33},1274982,"在室外敷设过程中,要将接地干线末端露出地面,以便续接接地线,其高度不宜超过( )mm。",[594,595,597,598],{"key":20,"text":245,"correct":22},{"key":24,"text":596,"correct":22},"300",{"key":27,"text":470,"correct":22},{"key":31,"text":599,"correct":29},"500",[601,604,607,610,613,616],{"id":15,"name":602,"category":7,"favorite":603},"领导干部任职前廉政法规知识测试题",92,{"id":605,"name":606,"category":7,"favorite":15},595,"建筑结构与设备",{"id":608,"name":609,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":611,"name":612,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":614,"name":615,"category":7,"favorite":8},534,"BIM工程师",{"id":617,"name":615,"category":7,"favorite":8},535]