[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-860-9":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":601},{"id":5,"name":6,"category":7,"favorite":8},860,"(装饰质量)专业管理实务 岗位知识","建筑工程",0,9,50,931,[13,34,46,58,70,82,94,105,115,127,139,150,162,174,186,198,210,222,234,246,258,268,280,292,304,313,325,337,349,361,373,385,397,409,421,433,445,457,469,481,493,505,517,529,541,549,557,569,577,589],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},1273912,1,"单选题","当住宅、幼儿园及小学等儿童活动场所电源插座底边距地面高度低于（ ）m时，必须选用安全型插座。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","1.8",true,{"key":24,"text":25,"correct":26},"B","2.0",false,{"key":28,"text":29,"correct":26},"C","2.2",{"key":31,"text":32,"correct":26},"D","2.4","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},1273913,"开向公共走道的窗扇，其底面高度应（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":26},"≥1.5m",{"key":24,"text":41,"correct":26},"≥1.8m",{"key":28,"text":43,"correct":22},"≥2.0m",{"key":31,"text":45,"correct":26},"≥2.5m",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},1273914,"分包单位与总承包单位签订分包合同，按照分包合同的约定应对（ ）负责。",[50,52,54,56],{"key":20,"text":51,"correct":26},"建设单位",{"key":24,"text":53,"correct":26},"施工单位",{"key":28,"text":55,"correct":26},"发包单位",{"key":31,"text":57,"correct":22},"总承包单位",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},1273915,"建筑工程的发包单位与承包单位应当依法订立（ ）施工合同，明确双方的权利和义务。",[62,64,66,68],{"key":20,"text":63,"correct":26},"口头",{"key":24,"text":65,"correct":22},"书面",{"key":28,"text":67,"correct":26},"临时",{"key":31,"text":69,"correct":26},"正式",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},1273916,"对于管根平面与管根周围立面转角处防水处理方法，以下不正确的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"凡遇到阴、阳角处，要抹成半径不小于5mm的小圆弧",{"key":24,"text":77,"correct":26},"管根与基层的交接部位，应预留宽环形凹槽，槽内应嵌密封材料",{"key":28,"text":79,"correct":26},"使用胎体增强材料做防水增强处理，施工时，边铺贴平整，边涂刷防水涂料",{"key":31,"text":81,"correct":26},"基层要求抹平压光无空鼓，表面要坚实，不应有起砂、掉灰现象",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},1273917,"根据《建设工程质量检测管理办法》（中华人民共和国建设部令第141号），具体规定：地基基础工程检测包括（ ）；桩的承载力检测；桩身完整性检测；锚杆锁定力检测。",[86,88,90,92],{"key":20,"text":87,"correct":26},"混凝土、砂浆、砌体强度现场检测",{"key":24,"text":89,"correct":22},"地基及符合地基承载力检测",{"key":28,"text":91,"correct":26},"钢筋保护层厚度检测",{"key":31,"text":93,"correct":26},"混凝土预制构件结构性能检测",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":31,"analysis":33},1273918,"工程质量的验收均应在（ ）自行检查评定的基础上进行。",[98,100,102,104],{"key":20,"text":99,"correct":26},"劳务单位",{"key":24,"text":101,"correct":26},"分包单位",{"key":28,"text":103,"correct":26},"总包单位",{"key":31,"text":53,"correct":22},{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":107,"options":108,"answer":31,"analysis":33},1273919,"隐蔽工程在隐蔽前，应由（ ）通知有关单位进行验收，并形成验收文件。",[109,110,112,114],{"key":20,"text":51,"correct":26},{"key":24,"text":111,"correct":26},"监理单位",{"key":28,"text":113,"correct":26},"业主",{"key":31,"text":53,"correct":22},{"id":116,"libraryId":5,"type":15,"typeLabel":16,"stem":117,"options":118,"answer":28,"analysis":33},1273920,"多层及高层钢结构主体结构的整体垂直度和整体平面弯曲的允许偏差应分别符合（ ）。",[119,121,123,125],{"key":20,"text":120,"correct":26},"H\u002F2500+10.0，且不应大于25.0L\u002F1500，且不应大于50.0",{"key":24,"text":122,"correct":26},"H\u002F2500，且不应大于25.0L\u002F1500，且不应大于25.0",{"key":28,"text":124,"correct":22},"H\u002F2500+10.0，且不应大于50.0L\u002F1500，且不应大于25.0",{"key":31,"text":126,"correct":26},"H\u002F2500，且不应大于25.0L\u002F1500，且不应大于50.0",{"id":128,"libraryId":5,"type":15,"typeLabel":16,"stem":129,"options":130,"answer":24,"analysis":33},1273921,"当装修施工的有关资料经审查全部表格、（ ）、现场检查或抽样检测测验结果全部合格时，工程验收应为合格。",[131,133,135,137],{"key":20,"text":132,"correct":26},"设计过程全部符合要求",{"key":24,"text":134,"correct":22},"施工过程全部符合要求",{"key":28,"text":136,"correct":26},"防火、防水处理过程全部符合要求",{"key":31,"text":138,"correct":26},"观感质量全部符合要求",{"id":140,"libraryId":5,"type":15,"typeLabel":16,"stem":141,"options":142,"answer":20,"analysis":33},1273922,"钢销式石材幕墙可以在非抗震设计或6度、7度抗震设中应用，幕墙高度不宜（ ）m，石板面积不宜（ ）㎡。",[143,145,147,149],{"key":20,"text":144,"correct":22},"大于20，大于1.0",{"key":24,"text":146,"correct":26},"大于20，小于1.0",{"key":28,"text":148,"correct":26},"小于20，大于1.0",{"key":31,"text":148,"correct":26},{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":24,"analysis":33},1273923,"民用建筑工程室内严禁使用（ ）清洗施工用具。",[154,156,158,160],{"key":20,"text":155,"correct":26},"无机溶剂",{"key":24,"text":157,"correct":22},"有机溶剂",{"key":28,"text":159,"correct":26},"强酸溶剂",{"key":31,"text":161,"correct":26},"强碱溶剂",{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":164,"options":165,"answer":31,"analysis":33},1273924,"根据《建设工程质量检测管理办法》（中华人民共和国建设部令第141号），具体规定：钢结构工程检测不包括下列那项（ ）。",[166,168,170,172],{"key":20,"text":167,"correct":26},"钢结构焊接质量无损检测",{"key":24,"text":169,"correct":26},"钢结构防腐蚀及防水涂装检测",{"key":28,"text":171,"correct":26},"钢结构点、机械连接用紧固标准文件及高强度螺栓力学性能检测",{"key":31,"text":173,"correct":22},"钢结构横截面尺寸大小检测",{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":176,"options":177,"answer":24,"analysis":33},1273925,"建设单位在领取（ ）或者开工报告前，应当按照国家有关规定办理工程质量监督手续。",[178,180,182,184],{"key":20,"text":179,"correct":26},"质检报告",{"key":24,"text":181,"correct":22},"施工许可证",{"key":28,"text":183,"correct":26},"施工进度表",{"key":31,"text":185,"correct":26},"财务报表",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":31,"analysis":33},1273926,"下列关于外墙防水工程各分项工程施工质量检验批数量的说法，错误的是（ ）。",[190,192,194,196],{"key":20,"text":191,"correct":26},"外墙面积每500~1000㎡为一个检验批",{"key":24,"text":193,"correct":26},"每个检验批应不少于3处",{"key":28,"text":195,"correct":26},"每个检验批每100㎡应至少抽查一处",{"key":31,"text":197,"correct":22},"抽查每处不小于20㎡",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":28,"analysis":33},1273927,"施工质量的隐蔽性主要是因为建筑产品生产过程（ ）。",[202,204,206,208],{"key":20,"text":203,"correct":26},"影响因素多",{"key":24,"text":205,"correct":26},"不可预见的因素多",{"key":28,"text":207,"correct":22},"工序交接多、隐蔽工程多",{"key":31,"text":209,"correct":26},"质量满足的要求既有明示的、又有隐含的",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":24,"analysis":33},1273928,"建建筑装饰装修工程所使用的材料应按设计要求进行（ ）处理。",[214,216,218,220],{"key":20,"text":215,"correct":26},"防爆、防滑和防火",{"key":24,"text":217,"correct":22},"防火、防腐和防虫",{"key":28,"text":219,"correct":26},"防水、防滑和防爆",{"key":31,"text":221,"correct":26},"防腐、防电和防爆",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":24,"analysis":33},1273929,"专设引下线（ ）根，并应沿建筑物四周和内庭院四周均匀对称布置，其间距沿周长计算（ ）m。",[226,228,230,232],{"key":20,"text":227,"correct":26},"不应大于2，不应大于5",{"key":24,"text":229,"correct":22},"不应少于2，不应少于5",{"key":28,"text":231,"correct":26},"不应大于2，不应少于5",{"key":31,"text":233,"correct":26},"不应少于2，不应大于5",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":31,"analysis":33},1273930,"装修施工过程中，当确需变更防火设计时，应经（ ）按有关规定进行。",[238,240,242,244],{"key":20,"text":239,"correct":26},"监理单位或具有相关资质的设计单位",{"key":24,"text":241,"correct":26},"施工单位或监理单位",{"key":28,"text":243,"correct":26},"施工单位或具有相关资质的施工单位",{"key":31,"text":245,"correct":22},"原设计单位或具有相关资质的设计单位",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":24,"analysis":33},1273931,"设计要求全焊透的一、二级焊缝应采用（ ）进行内部缺陷的检验，（ ）不能对缺陷作出判断，应采用（ ），其内部缺陷分级及探伤方法应符合现行国家标准。",[250,252,254,256],{"key":20,"text":251,"correct":26},"声波探伤，射线探伤，超声波探伤",{"key":24,"text":253,"correct":22},"超声波探伤，超声波探伤，射线探伤",{"key":28,"text":255,"correct":26},"射线探伤，射线探伤，超声波探伤",{"key":31,"text":257,"correct":26},"超声波探伤，射线探伤，超声波探伤",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":20,"analysis":33},1273932,"根据《建设工程质量检测管理办法》（中华人民共和国建设部令第-141号），主体结构工程检测不包括（ ）。",[262,263,264,266],{"key":20,"text":167,"correct":22},{"key":24,"text":87,"correct":26},{"key":28,"text":265,"correct":26},"钢筋保护层厚度检姍",{"key":31,"text":267,"correct":26},"后置埋件的力学性能检测",{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":20,"analysis":33},1273933,"因使用不当或者第三方造成的质量缺陷，不可抗力造成的质量缺陷，（ ）规定的保修范围。",[272,274,276,278],{"key":20,"text":273,"correct":22},"不属于",{"key":24,"text":275,"correct":26},"属于",{"key":28,"text":277,"correct":26},"部分属于",{"key":31,"text":279,"correct":26},"超出",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":28,"analysis":33},1273934,"检验同一施工批次、同一配合比的散水、明沟、踏步、台阶、坡道的水泥混凝土、水泥砂浆强度的试块，应按（ ）不少于1组。",[284,286,288,290],{"key":20,"text":285,"correct":26},"每100延长米",{"key":24,"text":287,"correct":26},"每120延长米",{"key":28,"text":289,"correct":22},"每150延长米",{"key":31,"text":291,"correct":26},"每200延长米",{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":24,"analysis":33},1273935,"根据我国相关文件规定，质量验收的基本单元是（ ）。",[296,298,300,302],{"key":20,"text":297,"correct":26},"分项工程",{"key":24,"text":299,"correct":22},"检验批",{"key":28,"text":301,"correct":26},"检验批和分项工程",{"key":31,"text":303,"correct":26},"分部工程",{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":28,"analysis":33},1273936,"隐蔽工程在隐蔽前应有（ ）通知有关单位进行验收，并应形成验收文件。",[308,309,310,311],{"key":20,"text":51,"correct":26},{"key":24,"text":111,"correct":26},{"key":28,"text":53,"correct":22},{"key":31,"text":312,"correct":26},"设计单位",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":20,"analysis":33},1273937,"幕墙结构的立柱与横梁在风荷载标准值作用下，钢型材的相对挠度不应大于（ ），绝对挠度不应大于（ ）；铝合金型材的相对挠度不应大于（ ），绝对挠度不大于（ ）。",[317,319,321,323],{"key":20,"text":318,"correct":22},"L\u002F300，15mm，L\u002F180，20mm",{"key":24,"text":320,"correct":26},"L\u002F300，20mm，L\u002F180，15mm",{"key":28,"text":322,"correct":26},"L\u002F180，15mm，L\u002F300，20mm",{"key":31,"text":324,"correct":26},"L\u002F180，20mm，L\u002F300，15mm",{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":28,"analysis":33},1273938,"实施过程建设性标准监督检查不采取下列那种方式（ ）。",[329,331,333,335],{"key":20,"text":330,"correct":26},"重点检查",{"key":24,"text":332,"correct":26},"抽查",{"key":28,"text":334,"correct":22},"随机检查",{"key":31,"text":336,"correct":26},"专项检查",{"id":338,"libraryId":5,"type":15,"typeLabel":16,"stem":339,"options":340,"answer":31,"analysis":33},1273939,"对于涂膜防水层平均厚度的测量方法可采取以下哪种方式（ ）。",[341,343,345,347],{"key":20,"text":342,"correct":26},"目测法",{"key":24,"text":344,"correct":26},"切片法，现场割取10mmx10mm实样用直尺测量",{"key":28,"text":346,"correct":26},"切片法，现场割取20mmx20mm实样用直尺测量",{"key":31,"text":348,"correct":22},"切片法，现场割取20mmx20mm实样用卡尺测量",{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":24,"analysis":33},1273940,"施工单位有下列（ ）行为的，由建设行政主管部门责令改正，并处1万元以上3万元以下的罚款。",[353,355,357,359],{"key":20,"text":354,"correct":26},"工程竣工验收后，向建设单位出具一年质量保证书的",{"key":24,"text":356,"correct":22},"质量保修的内容、期限违反本办法规定的",{"key":28,"text":358,"correct":26},"施工单位不履行保修义务的",{"key":31,"text":360,"correct":26},"施工单位拖延履行保修义务的",{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":28,"analysis":33},1273941,"工程监理单位违反强制性标准规定，将不合格的建设工程以及建筑材料、建筑构配件和设备按照合格签字的，责令改正，处（ ）万元以上（ ）万元以下的罚款，降低资质等级或吊销资质证书。",[365,367,369,371],{"key":20,"text":366,"correct":26},"10.30",{"key":24,"text":368,"correct":26},"20.50",{"key":28,"text":370,"correct":22},"50.100",{"key":31,"text":372,"correct":26},"100.150",{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":20,"analysis":33},1273942,"建设单位在工程竣工验收合格之日起（ ）内未办理工程竣工验收备案的，备案机关责令限期修正，处20万元以上50万元以下罚款。",[377,379,381,383],{"key":20,"text":378,"correct":22},"15日",{"key":24,"text":380,"correct":26},"25日",{"key":28,"text":382,"correct":26},"30日",{"key":31,"text":384,"correct":26},"一个月",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":20,"analysis":33},1273943,"材料或产品进场时还应符合下列规定：应有（ ）；应对型号、规格、外观等进行验收，对重要材料或产品应（ ）进行复验。",[389,391,393,395],{"key":20,"text":390,"correct":22},"质量合格文件，抽样",{"key":24,"text":392,"correct":26},"质量保修文件，全部",{"key":28,"text":394,"correct":26},"工作环境说明文件，抽样",{"key":31,"text":396,"correct":26},"工作环境说明文件，全部",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":31,"analysis":33},1273944,"违反工程建设强制性标准造成（ ）、安全隐患或者工程事故的，对事故责任人单位和责任人进行处罚。",[401,403,405,407],{"key":20,"text":402,"correct":26},"经济损失",{"key":24,"text":404,"correct":26},"人员伤亡",{"key":28,"text":406,"correct":26},"工期延误",{"key":31,"text":408,"correct":22},"工程质量",{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":411,"options":412,"answer":20,"analysis":33},1273945,"控制的重点是发现（ ），并通过分析提出施工质量改进的措施，保持质量处于受控状态。",[413,415,417,419],{"key":20,"text":414,"correct":22},"施工质量方面的缺陷",{"key":24,"text":416,"correct":26},"管理方面的缺陷",{"key":28,"text":418,"correct":26},"施工技术的不足",{"key":31,"text":420,"correct":26},"存在的安全隐患",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":20,"analysis":33},1273946,"隐框、半隐框幕墙所采用的结构粘结材料必须是中性硅酮结构密封胶，其性能必须符合（ ）的规定。",[425,427,429,431],{"key":20,"text":426,"correct":22},"《建筑用硅酮结构密封胶》GB16776",{"key":24,"text":428,"correct":26},"《检测用硅酮结构密封胶》GB16776",{"key":28,"text":430,"correct":26},"《结构用硅酮结构密封胶》GB17667",{"key":31,"text":432,"correct":26},"《试验用硅酮结构密封胶》GB17667",{"id":434,"libraryId":5,"type":15,"typeLabel":16,"stem":435,"options":436,"answer":24,"analysis":33},1273947,"钢网架结构总拼完成后及屋面工程完成后应分别测量其（ ），且所测（ ）不应超过相应设计值的（ ）倍。",[437,439,441,443],{"key":20,"text":438,"correct":26},"刚度值，刚度值，1.15",{"key":24,"text":440,"correct":22},"挠度值，挠度值，1.15",{"key":28,"text":442,"correct":26},"刚度值，挠度值，1.2",{"key":31,"text":444,"correct":26},"挠度值，刚度值，1.2",{"id":446,"libraryId":5,"type":15,"typeLabel":16,"stem":447,"options":448,"answer":24,"analysis":33},1273948,"室外低压配电线路应全线采用电缆（ ）敷设，在入户处应将电缆的金属外皮、钢管接到电位连接带或防闪电感应的接地装置上。",[449,451,453,455],{"key":20,"text":450,"correct":26},"室外",{"key":24,"text":452,"correct":22},"直接埋地",{"key":28,"text":454,"correct":26},"沿墙角",{"key":31,"text":456,"correct":26},"沿排水管",{"id":458,"libraryId":5,"type":15,"typeLabel":16,"stem":459,"options":460,"answer":20,"analysis":33},1273949,"对于室内防水工程涂膜防水层平均厚度的要求，以下哪种说法是正确的（ ）。",[461,463,465,467],{"key":20,"text":462,"correct":22},"涂膜总厚度不得低于1.5mm，最小厚度不应小于设计值的80%",{"key":24,"text":464,"correct":26},"涂膜总厚度不得低于1.5mm，最小厚度不应小于设计值的70%",{"key":28,"text":466,"correct":26},"涂膜总厚度不得低于1.2mm，最小厚度不应小于设计值的80％",{"key":31,"text":468,"correct":26},"涂膜总厚度不得低于1.2mm，最小厚度不应小于设计值的70％",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":24,"analysis":33},1273950,"单层结构主体结构的整体垂直度和整体平面弯曲的允许偏差应分别符合（ ）。",[473,475,477,479],{"key":20,"text":474,"correct":26},"H\u002F100+10.0，且不应大于25.0L\u002F1500，且不应大于50.0",{"key":24,"text":476,"correct":22},"H\u002F100，且不应大于25.0L\u002F1500，且不应大于25.0",{"key":28,"text":478,"correct":26},"H\u002F100+10.0，且不应大于50.0L\u002F1500，且不应大于25.0",{"key":31,"text":480,"correct":26},"H\u002F100，且不应大于25.0L\u002F1500，且不应大于50.0",{"id":482,"libraryId":5,"type":15,"typeLabel":16,"stem":483,"options":484,"answer":31,"analysis":33},1273951,"民用建筑工程室内装修中所采用的人造木板及饰面人造木板，必须有（ ）检测报告，并应符合设计要求和本规范的有关规定。",[485,487,489,491],{"key":20,"text":486,"correct":26},"游离甲醛含量或游离甲基丙胺释放量",{"key":24,"text":488,"correct":26},"无机化合物和游离甲醛释放量",{"key":28,"text":490,"correct":26},"有机化合物和甲基丙胺的含量",{"key":31,"text":492,"correct":22},"游离甲醛含量或游离甲醛释放量",{"id":494,"libraryId":5,"type":15,"typeLabel":16,"stem":495,"options":496,"answer":20,"analysis":33},1273952,"建设过程的最后一环是（ ），是投资转人生产或使用成果的标志。",[497,499,501,503],{"key":20,"text":498,"correct":22},"竣工验收",{"key":24,"text":500,"correct":26},"生产准备",{"key":28,"text":502,"correct":26},"建设准备",{"key":31,"text":504,"correct":26},"后评价阶段",{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":507,"options":508,"answer":28,"analysis":33},1273953,"建设单位应当（ ），依照本办法规定，向工程所在地的县级以上地方人民政府建设主管部门备案。",[509,511,513,515],{"key":20,"text":510,"correct":26},"自工程开工之日起15日内",{"key":24,"text":512,"correct":26},"自工程基础工程结束之日起",{"key":28,"text":514,"correct":22},"自工程竣工验收合格之日起15日内",{"key":31,"text":516,"correct":26},"自工程竣工验收之日起15日内",{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":31,"analysis":33},1273954,"在可能发生对地闪击的地区，下列不属于第二类防雷建筑物的情况（ ）。",[521,523,525,527],{"key":20,"text":522,"correct":26},"国家级重点文物保护建筑物",{"key":24,"text":524,"correct":26},"凡制造、使用或贮存火炸药及其制品的危险建筑，因电火花而引起爆炸、爆轰，会造成巨大破坏和人身伤亡者",{"key":28,"text":526,"correct":26},"国家特级和甲级大型体育馆",{"key":31,"text":528,"correct":22},"具有0区或20区爆炸危险场所的建筑物",{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":531,"options":532,"answer":28,"analysis":33},1273955,"厕所间和有防水要求的建筑地面必须设置（ ）。楼层结构必须采用现浇混凝土或整块混凝土板，混凝土强度等级（ ）。",[533,535,537,539],{"key":20,"text":534,"correct":26},"防水隔离层，大于C15",{"key":24,"text":536,"correct":26},"保温层，大于C20",{"key":28,"text":538,"correct":22},"防水隔离层，不应小于C20",{"key":31,"text":540,"correct":26},"保温层，不应小于C15",{"id":542,"libraryId":5,"type":15,"typeLabel":16,"stem":543,"options":544,"answer":24,"analysis":33},1273956,"单位工程完工后，（ ）应自行组织有关人员进行检查评定，并向建设单位提交工程验收报告。",[545,546,547,548],{"key":20,"text":101,"correct":26},{"key":24,"text":53,"correct":22},{"key":28,"text":111,"correct":26},{"key":31,"text":312,"correct":26},{"id":550,"libraryId":5,"type":15,"typeLabel":16,"stem":551,"options":552,"answer":24,"analysis":33},1273957,"施工单位有下列行为的，由建设行政主管部门责令改正，并处1万元以上3万元以下的罚款（ ）。",[553,554,555,556],{"key":20,"text":354,"correct":26},{"key":24,"text":356,"correct":22},{"key":28,"text":358,"correct":26},{"key":31,"text":360,"correct":26},{"id":558,"libraryId":5,"type":15,"typeLabel":16,"stem":559,"options":560,"answer":28,"analysis":33},1273958,"硅酮结构密封胶应根据不同的受力情况进行（ ）验算。",[561,563,565,567],{"key":20,"text":562,"correct":26},"抗拉强度",{"key":24,"text":564,"correct":26},"抗弯、扭承载力",{"key":28,"text":566,"correct":22},"承载力极限状态",{"key":31,"text":568,"correct":26},"变形程度",{"id":570,"libraryId":5,"type":15,"typeLabel":16,"stem":571,"options":572,"answer":20,"analysis":33},1273959,"根据《建设工程质量检测管理办法》（中华人民共和国建设部令第141号），具体规定：主体结构工程检测不包括下列那项（ ）。",[573,574,575,576],{"key":20,"text":167,"correct":22},{"key":24,"text":87,"correct":26},{"key":28,"text":91,"correct":26},{"key":31,"text":267,"correct":26},{"id":578,"libraryId":5,"type":15,"typeLabel":16,"stem":579,"options":580,"answer":31,"analysis":33},1273960,"不发火（防爆）面层中碎石的不发火性必须合格；砂应质地坚硬、表面粗糙，其粒径应为（ ），含泥量不应大于（ ），有机物含量不应大于（ ）。",[581,583,585,587],{"key":20,"text":582,"correct":26},"0.15～5mm，2%，0.5%",{"key":24,"text":584,"correct":26},"0.2～5mm，3%，0.6%",{"key":28,"text":586,"correct":26},"0.2～5mm，2%，0.6%",{"key":31,"text":588,"correct":22},"0.15～5mm，3%，0.5%",{"id":590,"libraryId":5,"type":15,"typeLabel":16,"stem":591,"options":592,"answer":20,"analysis":33},1273961,"空调与采暖系统冷热源设备和辅助设备及其管网系统的安装，哪项为不符合规定（ ）。",[593,595,597,599],{"key":20,"text":594,"correct":22},"冷热源和辅助设备必须进行单机试运转和调试",{"key":24,"text":596,"correct":26},"各种设备、自控阀门与仪表应按照设计要求安装齐全，不得随意增减或更换",{"key":28,"text":598,"correct":26},"空调冷热水系统，应能实现设计要求的变流量或定流量运行",{"key":31,"text":600,"correct":26},"供热系统应能根据热负荷及室内外温度变化实现设计要求的集中质量调节、量调节或质—量调节相结合的运行",[602,605,608,611,614,617],{"id":15,"name":603,"category":7,"favorite":604},"领导干部任职前廉政法规知识测试题",92,{"id":606,"name":607,"category":7,"favorite":15},595,"建筑结构与设备",{"id":609,"name":610,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":612,"name":613,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":615,"name":616,"category":7,"favorite":8},534,"BIM工程师",{"id":618,"name":616,"category":7,"favorite":8},535]