[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-860-14":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":718},{"id":5,"name":6,"category":7,"favorite":8},860,"(装饰质量)专业管理实务 岗位知识","建筑工程",0,14,50,931,[13,38,53,63,78,93,108,123,137,151,166,180,194,209,224,239,248,262,276,291,306,320,334,348,362,376,390,404,418,432,446,460,474,488,503,517,531,546,560,569,584,596,610,625,639,653,667,676,690,704],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},1274163,2,"多选题","墙体与门窗框交接处抹灰层空鼓、裂缝脱落的防治措施（ ）。",[19,23,27,30,33],{"key":20,"text":21,"correct":22},"A","抹灰前，应将基层表面清扫干净，脚手眼等孔洞填堵严实",false,{"key":24,"text":25,"correct":26},"B","不同基层材料交汇处宜铺钉钢板网，每边搭接长度应大于10cm",true,{"key":28,"text":29,"correct":26},"C","门洞每侧墙体内预埋木砖不少于三块，木砖尺寸应与标准砖相同，并经防腐处理，预埋位置正确",{"key":31,"text":32,"correct":26},"D","门窗框塞缝宜采用混合砂浆，塞缝前先浇水湿润，缝隙过大时，应分层多次填嵌，砂浆不宜太稀",{"key":34,"text":35,"correct":26},"E","加气混凝土砌块墙与门窗框联结时，应先在墙体内钻深10cm、孔直径4cm左右，再用相同尺寸的圆木沾上108胶水后打入孔内。每倒不少四处","BCDE","",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":52,"analysis":37},1274164,"立管四周渗漏的防治措施包括（ ）。",[42,44,46,48,50],{"key":20,"text":43,"correct":22},"墙面上设有热水器时，其防水高度为1500mm；淋浴处墙面防水高度不应大于1800mm",{"key":24,"text":45,"correct":22},"墙体根部与地面的转角处找平层应做成钝角",{"key":28,"text":47,"correct":26},"穿楼板的立管应按规定预埋套管",{"key":31,"text":49,"correct":26},"立管与套管之间的环隙应用密封材料填塞密实",{"key":34,"text":51,"correct":26},"套管高度应比设计地面高出20mm以上；套管周边做同高度的细石混凝土防水保护墩","CDE",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":52,"analysis":37},1274165,"立管四周渗漏的防治措施（ ）。",[57,59,60,61,62],{"key":20,"text":58,"correct":22},"墙面上设有水器时，其防水高度为1500mm；淋浴处墙面防水高度不应大于1800mm",{"key":24,"text":45,"correct":22},{"key":28,"text":47,"correct":26},{"key":31,"text":49,"correct":26},{"key":34,"text":51,"correct":26},{"id":64,"libraryId":5,"type":15,"typeLabel":16,"stem":65,"options":66,"answer":77,"analysis":37},1274166,"工程质量事故的分类（ ）。",[67,69,71,73,75],{"key":20,"text":68,"correct":26},"特别重大事故",{"key":24,"text":70,"correct":26},"重大事故",{"key":28,"text":72,"correct":26},"较大事故",{"key":31,"text":74,"correct":26},"一般事故",{"key":34,"text":76,"correct":26},"普通事故","ABCDE",{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":92,"analysis":37},1274167,"壁纸翘边的原因分析包括（ ）。",[82,84,86,88,90],{"key":20,"text":83,"correct":26},"涂刷胶液不均匀，漏刷或胶液过早干燥",{"key":24,"text":85,"correct":26},"基层有灰尘、油污等，或表面粗糙干燥、潮湿，胶液与基层粘结不牢，使纸边翘起",{"key":28,"text":87,"correct":22},"根据不同的施工环境温度，基层表面及壁纸品种，选择不同的粘胶剂，使纸边翘起",{"key":31,"text":89,"correct":26},"胶粘剂黏性小，造成纸边翘起，特别是阴角处，第2张壁纸粘贴在第1张壁纸的塑料面上，更易出现翘起",{"key":34,"text":91,"correct":26},"阳角处裹过阳角的壁纸宽度小于20mm，未能克服壁纸的表面张力，也易翘起","ABDE",{"id":94,"libraryId":5,"type":15,"typeLabel":16,"stem":95,"options":96,"answer":107,"analysis":37},1274168,"运用（ ）等统计方法进行分析，确定建筑装饰装修工程施工质量问题产生的原因。",[97,99,101,103,105],{"key":20,"text":98,"correct":26},"因果图、调查表",{"key":24,"text":100,"correct":26},"分层法、直方图",{"key":28,"text":102,"correct":26},"调查表、分层法",{"key":31,"text":104,"correct":26},"控制图、散布图",{"key":34,"text":106,"correct":22},"抽样调查表","ABCD",{"id":109,"libraryId":5,"type":15,"typeLabel":16,"stem":110,"options":111,"answer":122,"analysis":37},1274169,"暗龙骨吊顶分项工程检验批检验的主控项目包括（ ）。",[112,114,116,118,120],{"key":20,"text":113,"correct":22},"允许偏差",{"key":24,"text":115,"correct":26},"标高、尺寸、起拱、造型",{"key":28,"text":117,"correct":26},"吊杆、龙骨和饰面材料",{"key":31,"text":119,"correct":22},"填充吸声材料",{"key":34,"text":121,"correct":22},"饰面板上设备安装","BC",{"id":124,"libraryId":5,"type":15,"typeLabel":16,"stem":125,"options":126,"answer":77,"analysis":37},1274170,"外墙面砖空鼓、脱落的防治措施包括（ ）。",[127,129,131,133,135],{"key":20,"text":128,"correct":26},"在结构施工时，外墙应尽可能按清水墙标准，做到平整垂直，为饰面施工创造条件",{"key":24,"text":130,"correct":26},"面砖在使用前，必须清洗干净，并隔夜用水浸泡，晾干后（外干内湿）才能使用",{"key":28,"text":132,"correct":26},"在面砖粘贴过程中，宜做到一次成活，不宜移动，尤其是砂浆收水后再纠偏挪动，最容易引起空鼓",{"key":31,"text":134,"correct":26},"粘贴面砖砂浆要饱满，但使用砂浆过多，面砖又不易贴平",{"key":34,"text":136,"correct":26},"作好勾缝",{"id":138,"libraryId":5,"type":15,"typeLabel":16,"stem":139,"options":140,"answer":77,"analysis":37},1274171,"塑料墙纸和墙布具有（ ）等特点。",[141,143,145,147,149],{"key":20,"text":142,"correct":26},"装饰效果好",{"key":24,"text":144,"correct":26},"性能优越",{"key":28,"text":146,"correct":26},"适合大规模生产",{"key":31,"text":148,"correct":26},"粘贴施工方便",{"key":34,"text":150,"correct":26},"使用寿命长、易维修保养",{"id":152,"libraryId":5,"type":15,"typeLabel":16,"stem":153,"options":154,"answer":165,"analysis":37},1274172,"影响施工质量的因素包括（ ）。",[155,157,159,161,163],{"key":20,"text":156,"correct":26},"人、机械",{"key":24,"text":158,"correct":22},"设计图纸",{"key":28,"text":160,"correct":26},"机械、材料",{"key":31,"text":162,"correct":26},"施工方法",{"key":34,"text":164,"correct":26},"环境条件","ACDE",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":77,"analysis":37},1274173,"外墙涂料花纹不匀，花纹图案大小不一；局部流淌下坠；有明显的接槎防治措施包括（ ）。",[170,172,174,176,178],{"key":20,"text":171,"correct":26},"控制好骨料稠度，专人负责搅拌",{"key":24,"text":173,"correct":26},"基层应干湿一致",{"key":28,"text":175,"correct":26},"防止放“空枪”，应有专人加骨料；局部成片出浆、流坠，要及时铲去重喷",{"key":31,"text":177,"correct":26},"喷涂要连续作业，保持工作面“软接槎”，到分格缝处停歇",{"key":34,"text":179,"correct":26},"停歇前，应有专人作好未成活部位的遮挡工作，若已溅上骨料应及时清除",{"id":181,"libraryId":5,"type":15,"typeLabel":16,"stem":182,"options":183,"answer":77,"analysis":37},1274174,"骨架隔墙分项工程检验批质量检验的主控项目包括（ ）。",[184,186,188,190,192],{"key":20,"text":185,"correct":26},"材料品种、规格、性能",{"key":24,"text":187,"correct":26},"骨件与基体连接",{"key":28,"text":189,"correct":26},"骨架间距和构造连接",{"key":31,"text":191,"correct":26},"木质材料防火、防腐",{"key":34,"text":193,"correct":26},"墙面板安装；接缝材料、方法",{"id":195,"libraryId":5,"type":15,"typeLabel":16,"stem":196,"options":197,"answer":208,"analysis":37},1274175,"抹窗台板、踢脚线（或墙裙）时，应以（ ）水泥砂浆抹底层，表面划毛，隔1d后，用素水泥浆刷一道，再用（ ）水泥砂浆抹面。",[198,200,202,204,206],{"key":20,"text":199,"correct":22},"1:1",{"key":24,"text":201,"correct":22},"1:2",{"key":28,"text":203,"correct":26},"1:3",{"key":31,"text":205,"correct":22},"1:1.5",{"key":34,"text":207,"correct":26},"1：2.5","CE",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":223,"analysis":37},1274176,"某项目防水涂层厚度的设计要求为1.5mm厚，下列检验数据，符合验收要求的有（ ）。",[213,215,217,219,221],{"key":20,"text":214,"correct":26},"1.5mm",{"key":24,"text":216,"correct":26},"1.45mm",{"key":28,"text":218,"correct":26},"1035mm",{"key":31,"text":220,"correct":22},"1.25mm",{"key":34,"text":222,"correct":22},"1.2mm","ABC",{"id":225,"libraryId":5,"type":15,"typeLabel":16,"stem":226,"options":227,"answer":238,"analysis":37},1274177,"涂饰工程施工时，外墙涂料饰面起鼓、起皮、脱落的原因有（ ）。",[228,230,232,234,236],{"key":20,"text":229,"correct":22},"基层pH值为9.5",{"key":24,"text":231,"correct":26},"基层表面不坚实",{"key":28,"text":233,"correct":26},"基层表面有油污、粉尘等",{"key":31,"text":235,"correct":22},"基层含水率为8％",{"key":34,"text":237,"correct":26},"基层表面太光滑，腻子强度低","BCE",{"id":240,"libraryId":5,"type":15,"typeLabel":16,"stem":241,"options":242,"answer":165,"analysis":37},1274178,"影响施工质量的因素包括（ ）",[243,244,245,246,247],{"key":20,"text":156,"correct":26},{"key":24,"text":158,"correct":22},{"key":28,"text":160,"correct":26},{"key":31,"text":162,"correct":26},{"key":34,"text":164,"correct":26},{"id":249,"libraryId":5,"type":15,"typeLabel":16,"stem":250,"options":251,"answer":92,"analysis":37},1274179,"纤维板吊顶面层装钉后，部分板块逐渐产生凹凸变形现象的原因有（ ）。",[252,254,256,258,260],{"key":20,"text":253,"correct":26},"纤维板在使用中吸收水分",{"key":24,"text":255,"correct":26},"装钉时，从四角或四周向中心排钉装钉",{"key":28,"text":257,"correct":22},"吊顶格栅造型不对称、布局不合理",{"key":31,"text":259,"correct":26},"装钉板块时，板块接头未留空隙",{"key":34,"text":261,"correct":26},"吊顶分格过大",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":165,"analysis":37},1274180,"针对建筑装饰装修工程施工质量问题进行分析的统计方法有（ ）。",[266,268,270,272,274],{"key":20,"text":267,"correct":26},"排列图法",{"key":24,"text":269,"correct":22},"价值分析法",{"key":28,"text":271,"correct":26},"关系图法",{"key":31,"text":273,"correct":26},"调查表法",{"key":34,"text":275,"correct":26},"散布图法",{"id":277,"libraryId":5,"type":15,"typeLabel":16,"stem":278,"options":279,"answer":290,"analysis":37},1274181,"施工质量缺陷原因分析应针对影响施工质量的几大因素，这些因素有（ ）。",[280,282,284,286,288],{"key":20,"text":281,"correct":26},"人的因素",{"key":24,"text":283,"correct":26},"机械的因素",{"key":28,"text":285,"correct":26},"环境的因素",{"key":31,"text":287,"correct":22},"经济的因素",{"key":34,"text":289,"correct":26},"材料的因素","ABCE",{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":305,"analysis":37},1274182,"某项目门厅进行水磨石面层施工，设计文件中规定以普通水磨石面层标准进行验收，项目部进行了施工方案的编制。主要内容如下：浅色的水磨石面层采用硅酸盐水泥；彩色面层采用酸性颜料进行调色，掺人量为水泥重量的5％；水磨石面层结合层采用水泥砂浆。监理工程师验收时，发现有若干区域出现空鼓现象。根据背景资料，回答下列问题。 下列关于普通水磨石面层质量检验标准的说法，正确的有（ ）。",[295,297,299,301,303],{"key":20,"text":296,"correct":26},"水磨石表面平整度偏差不得大于3mm",{"key":24,"text":298,"correct":22},"水磨石踢脚线上口平直度偏差不得大于2mm",{"key":28,"text":300,"correct":26},"水磨石缝格平直度偏差不得大于3mm",{"key":31,"text":302,"correct":22},"普通水磨石面层磨光遍数不应少于2遍",{"key":34,"text":304,"correct":26},"水磨石颜料掺人量可以为5％","ACE",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":36,"analysis":37},1274183,"某商场进行内部装修工程。验收过程中发现瓷砖有大量空鼓、脱落现象，经过分析，为瓷砖铺贴过程中，工人操作不当造成，且部分瓷砖质量存在问题。根据背景资料，回答下列问题。 下列关于饰面砖粘贴工程施工质量控制要点的说法，正确的有（ ）。",[310,312,314,316,318],{"key":20,"text":311,"correct":22},"饰面砖的品种选择应以国家规范为主要依据",{"key":24,"text":313,"correct":26},"饰面砖粘贴必须牢固",{"key":28,"text":315,"correct":26},"阴阳角处搭接方式应符合设计要求",{"key":31,"text":317,"correct":26},"外墙饰面砖粘贴前应在相同基层上做样板件，并进行粘结强度试验",{"key":34,"text":319,"correct":26},"满粘法施工的饰面砖工程应无空鼓、裂缝",{"id":321,"libraryId":5,"type":15,"typeLabel":16,"stem":322,"options":323,"answer":107,"analysis":37},1274184,"施工质量事故报告通常应包括的内容有（ ）。",[324,326,328,330,332],{"key":20,"text":325,"correct":26},"事故发生的时间、地点、项目名称",{"key":24,"text":327,"correct":26},"事故发生的简要经过、伤亡人数",{"key":28,"text":329,"correct":26},"事故发生的原因和事故性质",{"key":31,"text":331,"correct":26},"事故发生后采取的措施及事故控制情况",{"key":34,"text":333,"correct":22},"事故报告单位、联系人及联系方式",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":107,"analysis":37},1274185,"造成大理石楼、地面空鼓的主要原因有（ ）。",[338,340,342,344,346],{"key":20,"text":339,"correct":26},"大理石材质松软，有背网，施工时不可能将背网撕下后再铺贴",{"key":24,"text":341,"correct":26},"一般情况下，楼地面铺贴石材已是工程尾声，肯定进人倒计时阶段，工期紧迫，施工程序已经顾不上了",{"key":28,"text":343,"correct":26},"铺贴石材的水泥砂浆尚未到达终凝期，就上机打磨进人镜面处理阶段，机器抖动将水泥砂浆振得酥松",{"key":31,"text":345,"correct":26},"成品保护未及时进行",{"key":34,"text":347,"correct":22},"工期紧迫，项目抢工",{"id":349,"libraryId":5,"type":15,"typeLabel":16,"stem":350,"options":351,"answer":107,"analysis":37},1274186,"下列关于公共建筑室内外台阶踏步的说法，正确的有（ ）。",[352,354,356,358,360],{"key":20,"text":353,"correct":26},"公共建筑室内外台阶踏步的宽度不宜\u003C0.30m",{"key":24,"text":355,"correct":26},"踏步的高度不宜>0.15m且不宜\u003C0.10m",{"key":28,"text":357,"correct":26},"相邻踏步的宽差、高差应≤10mm",{"key":31,"text":359,"correct":26},"踏步坡度应内高外低，约0.5％",{"key":34,"text":361,"correct":22},"踏步坡度应内低外高，约0.5％",{"id":363,"libraryId":5,"type":15,"typeLabel":16,"stem":364,"options":365,"answer":107,"analysis":37},1274187,"装饰施工企业拟申报“市优”、“省优”、“国优”的项目，企业必须具备的资质资料有（ ）。",[366,368,370,372,374],{"key":20,"text":367,"correct":26},"企业法人证照",{"key":24,"text":369,"correct":26},"资质等级证书",{"key":28,"text":371,"correct":26},"安全生产许可证",{"key":31,"text":373,"correct":26},"企业专业技术人员配备",{"key":34,"text":375,"correct":22},"企业全部的工程业绩",{"id":377,"libraryId":5,"type":15,"typeLabel":16,"stem":378,"options":379,"answer":165,"analysis":37},1274188,"装饰施工企业拟申报“市优”、“省优”、“国优”的项目，施工合同应重点关注的重点有（ ）。",[380,382,384,386,388],{"key":20,"text":381,"correct":26},"施工范围及施工内容",{"key":24,"text":383,"correct":22},"合同是否申报",{"key":28,"text":385,"correct":26},"中标通知书",{"key":31,"text":387,"correct":26},"有无特殊约定条款",{"key":34,"text":389,"correct":26},"申报工程名称与合同中工程名称是否相符",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":223,"analysis":37},1274189,"石材幕墙工程应对（ ）进行复验。",[394,396,398,400,402],{"key":20,"text":395,"correct":26},"石材幕墙挂件材质",{"key":24,"text":397,"correct":26},"石材幕墙挂件规格",{"key":28,"text":399,"correct":26},"石材幕墙挂件厚度",{"key":31,"text":401,"correct":22},"石材幕墙挂件数量",{"key":34,"text":403,"correct":22},"石材放射性",{"id":405,"libraryId":5,"type":15,"typeLabel":16,"stem":406,"options":407,"answer":107,"analysis":37},1274190,"下列关于建筑装饰玻璃使用方法的说法，正确的有（ ）。",[408,410,412,414,416],{"key":20,"text":409,"correct":26},"双面弹簧门应在可视高度部分安装透明安全玻璃",{"key":24,"text":411,"correct":26},"安装压花玻璃，压花面应朝室外；安装磨砂玻璃，磨砂面应朝室内",{"key":28,"text":413,"correct":26},"磨砂玻璃用在厨房间时，磨砂面应朝外，否则厨房间的油烟粘在磨砂面上不宜清洗",{"key":31,"text":415,"correct":26},"全玻璃门应采用安全玻璃，并应在玻璃门上设置防冲撞提示标识",{"key":34,"text":417,"correct":22},"天窗必须采用安全玻璃",{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":223,"analysis":37},1274191,"担任建筑装饰“精品工程”项目的项目经理必须提供的资料有（ ）。",[422,424,426,428,430],{"key":20,"text":423,"correct":26},"项目经理证书",{"key":24,"text":425,"correct":26},"安全考核证（安全生产B证）",{"key":28,"text":427,"correct":26},"身份证",{"key":31,"text":429,"correct":22},"专业职务证书",{"key":34,"text":431,"correct":22},"企业聘任证明",{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":434,"options":435,"answer":223,"analysis":37},1274192,"建筑外门窗水密性能分级表表述正确的（ ）。（单位Pa）。",[436,438,440,442,444],{"key":20,"text":437,"correct":26},"一级分级指标值100≤△P＜150",{"key":24,"text":439,"correct":26},"二级分级指标值150≤△P＜250",{"key":28,"text":441,"correct":26},"三级分级指标值250≤△P＜350",{"key":31,"text":443,"correct":22},"四级分级指标值350≤△P＜450",{"key":34,"text":445,"correct":22},"五级分级指标值450≤△P＜550",{"id":447,"libraryId":5,"type":15,"typeLabel":16,"stem":448,"options":449,"answer":107,"analysis":37},1274193,"饰面板安装工程的（ ）和防腐处理必须符合设计要求。",[450,452,454,456,458],{"key":20,"text":451,"correct":26},"预埋件（或后置埋件）",{"key":24,"text":453,"correct":26},"连接件数量",{"key":28,"text":455,"correct":26},"连接件规格",{"key":31,"text":457,"correct":26},"连接件位置",{"key":34,"text":459,"correct":22},"连接件生产厂家",{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":107,"analysis":37},1274194,"拟创建筑装饰“精品工程”的项目，应特别关注的安全隐患问题有（ ）。",[464,466,468,470,472],{"key":20,"text":465,"correct":26},"改动建筑主体、承重结构、增加结构荷载的安全问题",{"key":24,"text":467,"correct":26},"室内干挂石材墙、柱面的安全问题",{"key":28,"text":469,"correct":26},"共享空间、中庭的栏杆、栏板，临空落地窗及楼梯防护的安全问题",{"key":31,"text":471,"correct":26},"大型吊灯安装的安全问题",{"key":34,"text":473,"correct":22},"普通玻璃使用的相关问题",{"id":475,"libraryId":5,"type":15,"typeLabel":16,"stem":476,"options":477,"answer":77,"analysis":37},1274195,"引拉法玻璃有（ ）mm等种类。",[478,480,482,484,486],{"key":20,"text":479,"correct":26},"2",{"key":24,"text":481,"correct":26},"3",{"key":28,"text":483,"correct":26},"4",{"key":31,"text":485,"correct":26},"5",{"key":34,"text":487,"correct":26},"6",{"id":489,"libraryId":5,"type":15,"typeLabel":16,"stem":490,"options":491,"answer":502,"analysis":37},1274196,"《建筑节能工程施工质量验收规范》GB50411—2007，强制性条文中：墙体节能工程的施工应符合下列那些规定（ ）。",[492,494,496,498,500],{"key":20,"text":493,"correct":22},"保温浆料待结构成型后统一施工",{"key":24,"text":495,"correct":26},"保温隔热材料的厚度必须符合设计要求",{"key":28,"text":497,"correct":26},"保温板与基层及各构层之间的粘结或连接必须牢固",{"key":31,"text":499,"correct":26},"当墙体节能工程的保温层采取预埋或后置锚固件固定时，锚固件数量、位置、锚固深度和拉拔力应符合设计要求",{"key":34,"text":501,"correct":22},"各种设备、总控阀门与仪表应按设计要求安装齐全，不得随意增减和更换","BCD",{"id":504,"libraryId":5,"type":15,"typeLabel":16,"stem":505,"options":506,"answer":516,"analysis":37},1274197,"《建筑节能工程施工质量验收规范》GB50411—2007，强制性条文中：采暖系统的安装应符合下列那些规定（ ）。",[507,509,511,513,515],{"key":20,"text":508,"correct":26},"采暖系统的制式，应符合设计要求",{"key":24,"text":510,"correct":26},"散热设备、阀门、过滤器、温度计及仪表应按设计要求安装齐全，不得随意增减和更换",{"key":28,"text":512,"correct":22},"保温材料应分层施工",{"key":31,"text":514,"correct":26},"室内温度调整控制、热计量装置、水利平衡装置以及热力入口设置的安装位置和方向应符合设计要求，并便于观察、操作和调试",{"key":34,"text":501,"correct":22},"ABD",{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":165,"analysis":37},1274198,"《屋面工程质量验收规范》GB50207—2012，其中强制性文件中，保温材料的（ ）必须符合设计要求。",[521,523,525,527,529],{"key":20,"text":522,"correct":26},"导热系数",{"key":24,"text":524,"correct":22},"刚度系数",{"key":28,"text":526,"correct":26},"表观密度或干密度",{"key":31,"text":528,"correct":26},"抗压强度或压缩强度",{"key":34,"text":530,"correct":26},"燃烧性能",{"id":532,"libraryId":5,"type":15,"typeLabel":16,"stem":533,"options":534,"answer":545,"analysis":37},1274199,"房屋建设工程质量保修范围、保修期限说法正确的是（ ）。",[535,537,539,541,543],{"key":20,"text":536,"correct":22},"房屋建筑工程保修期从工程开工之日算起",{"key":24,"text":538,"correct":26},"地基基础工程和主体结构工程，为设计文件规定的该工程的合理使用年限",{"key":28,"text":540,"correct":22},"屋面防水工程、有防水要求的卫生间、房间和外墙面的防渗漏，为3年",{"key":31,"text":542,"correct":26},"供热与供冷系统，为2个采暖期、供冷期",{"key":34,"text":544,"correct":26},"电气管线、给排水管道、设备安装为两年；装修工程为2年；保温工程为5年","BDE",{"id":547,"libraryId":5,"type":15,"typeLabel":16,"stem":548,"options":549,"answer":77,"analysis":37},1274200,"建筑节能分部工程质量验收合格，应符合下列哪些规定（ ）。",[550,552,554,556,558],{"key":20,"text":551,"correct":26},"分项工程应全部合格",{"key":24,"text":553,"correct":26},"质量控制资料应完整",{"key":28,"text":555,"correct":26},"外墙节能构造现场实体检验结果应符合设计要求",{"key":31,"text":557,"correct":26},"严寒、寒冷和夏热冬冷地区的外窗气密性现场实体检验结果应合格",{"key":34,"text":559,"correct":26},"建筑设备工程系统节能性能检测结果应合格",{"id":561,"libraryId":5,"type":15,"typeLabel":16,"stem":562,"options":563,"answer":77,"analysis":37},1274201,"建筑节能分部工程质量验收合格，应符合下列规定（ ）。",[564,565,566,567,568],{"key":20,"text":551,"correct":26},{"key":24,"text":553,"correct":26},{"key":28,"text":555,"correct":26},{"key":31,"text":557,"correct":26},{"key":34,"text":559,"correct":26},{"id":570,"libraryId":5,"type":15,"typeLabel":16,"stem":571,"options":572,"answer":583,"analysis":37},1274202,"建设单位有下列行为（ ）责令改正，并处以20万以上及50万以下的罚款。",[573,575,577,579,581],{"key":20,"text":574,"correct":26},"明示或者暗示施工单位使用不合格的建筑材料、建筑构配件和设备的",{"key":24,"text":576,"correct":26},"明示或者暗示设计单位或者施工单位违反工程建设强制性标准、降低工程质量的",{"key":28,"text":578,"correct":22},"对发现的安全生产违章违规行为或安全隐患，未予以纠正或作出处理决定",{"key":31,"text":580,"correct":22},"对施工现场存在的重大安全隐患未向建设主管部门报告",{"key":34,"text":582,"correct":22},"明示或者暗示设计单位或者施工单位随意修改图纸","AB",{"id":585,"libraryId":5,"type":15,"typeLabel":16,"stem":586,"options":587,"answer":583,"analysis":37},1274203,"建设单位有下列行为的责令改正，并处以20万以上及50万以下的罚款（ ）。",[588,589,590,592,594],{"key":20,"text":574,"correct":26},{"key":24,"text":576,"correct":26},{"key":28,"text":591,"correct":22},"对发现的安全生产违章违规行为或安全隐患，未予以纠正或作出处理决定的",{"key":31,"text":593,"correct":22},"对施工现场存在的重大安全隐患未向建设主管部门报告的",{"key":34,"text":595,"correct":22},"明示或者暗示设计单位或者施工单位随意修改图纸的",{"id":597,"libraryId":5,"type":15,"typeLabel":16,"stem":598,"options":599,"answer":36,"analysis":37},1274204,"在可能发生对地闪击的地区，划为第二类防雷建筑物的情况有（ ）。",[600,602,604,606,608],{"key":20,"text":601,"correct":22},"省级重点文物保护的建筑物及省级档案馆",{"key":24,"text":603,"correct":26},"国家级的会堂、办公建筑物、大型展览和博览建筑物、大型火车站和飞机场、国宾馆，国家级档案馆、大型城市的重要给水泵房等特别重要的建筑物",{"key":28,"text":605,"correct":26},"国家及计算机中心、国际通信枢纽等对国民经济有重要意义的建筑物",{"key":31,"text":607,"correct":26},"国家级重点文物保护建筑物",{"key":34,"text":609,"correct":26},"国家特级和甲级大型体育馆",{"id":611,"libraryId":5,"type":15,"typeLabel":16,"stem":612,"options":613,"answer":624,"analysis":37},1274205,"建筑装饰施工，检验批应由监理工程师组织施工单位的（ ）等进行验收。",[614,616,618,620,622],{"key":20,"text":615,"correct":22},"施工操作者",{"key":24,"text":617,"correct":22},"专业工长",{"key":28,"text":619,"correct":26},"项目专业质量负责人",{"key":31,"text":621,"correct":26},"项目专业技术负责人",{"key":34,"text":623,"correct":22},"项目安全员","CD",{"id":626,"libraryId":5,"type":15,"typeLabel":16,"stem":627,"options":628,"answer":77,"analysis":37},1274206,"根据《建设工程质量检测管理办法》（中华人民共和国建设部令第141号），具体规定：见证取样检测包括（ ）。",[629,631,633,635,637],{"key":20,"text":630,"correct":26},"水泥物理力学性能检测",{"key":24,"text":632,"correct":26},"钢筋（含焊接与机械连接）力学性能检测明",{"key":28,"text":634,"correct":26},"砂、石常规检验",{"key":31,"text":636,"correct":26},"混凝土、砂浆强度检验",{"key":34,"text":638,"correct":26},"简易土工检验",{"id":640,"libraryId":5,"type":15,"typeLabel":16,"stem":641,"options":642,"answer":36,"analysis":37},1274207,"幕墙安装施工应对下列哪些项目进行验收（ ）。",[643,645,647,649,651],{"key":20,"text":644,"correct":22},"应对横竖连接件进行检查、测量、调整",{"key":24,"text":646,"correct":26},"主体结构与立柱、立柱与横梁连接节点安装及防腐处理",{"key":28,"text":648,"correct":26},"幕墙的防火、保温安装",{"key":31,"text":650,"correct":26},"幕墙的伸缩缝、沉降缝、防震缝及阴阳角的安装",{"key":34,"text":652,"correct":26},"幕墙的防雷节点安装",{"id":654,"libraryId":5,"type":15,"typeLabel":16,"stem":655,"options":656,"answer":545,"analysis":37},1274208,"下列关于施工现场用电的说法，正确的有（ ）。",[657,659,661,663,665],{"key":20,"text":658,"correct":22},"暂停施工时可不切断电源",{"key":24,"text":660,"correct":26},"临时施工供电开关箱中应装设漏电保护器",{"key":28,"text":662,"correct":22},"进人开关箱的电源可以用插销连接",{"key":31,"text":664,"correct":26},"安装临时施工用电系统，应由电工完成",{"key":34,"text":666,"correct":26},"施工现场用电应从户表以后设立临时施工用电系统",{"id":668,"libraryId":5,"type":15,"typeLabel":16,"stem":669,"options":670,"answer":502,"analysis":37},1274209,"《建筑节能工程施工质量验收规范》GB50411--2007的强制性条文中，墙体节能工程的施工应符合下列哪些规定（ ）。",[671,672,673,674,675],{"key":20,"text":493,"correct":22},{"key":24,"text":495,"correct":26},{"key":28,"text":497,"correct":26},{"key":31,"text":499,"correct":26},{"key":34,"text":501,"correct":22},{"id":677,"libraryId":5,"type":15,"typeLabel":16,"stem":678,"options":679,"answer":502,"analysis":37},1274210,"建筑外门窗的三性检测项目是指（。",[680,682,684,686,688],{"key":20,"text":681,"correct":22},"A.抗变形性能",{"key":24,"text":683,"correct":26},"气密性性能",{"key":28,"text":685,"correct":26},"水密性性能",{"key":31,"text":687,"correct":26},"抗风压性能",{"key":34,"text":689,"correct":22},"抗冲击性能",{"id":691,"libraryId":5,"type":15,"typeLabel":16,"stem":692,"options":693,"answer":52,"analysis":37},1274211,"《建筑内部装修防火施工及验收规范》GB50354—2005，工程质量验收应符合下列哪些要求（ ）。",[694,696,698,700,702],{"key":20,"text":695,"correct":22},"装修施工过程中，装修材料应远离火源，并应派专人负责施工现场的防火安全",{"key":24,"text":697,"correct":22},"装修施工过程中，应对各装修部位的施工过程做详细记录",{"key":28,"text":699,"correct":26},"所有装修材料或产品的见证取样检测结果应满足设计要求",{"key":31,"text":701,"correct":26},"现场进行阻燃处理、喷涂、安装作业的抽样检查结果应符合设计要求",{"key":34,"text":703,"correct":26},"施工过程中的主控项目检验结果应全部合格",{"id":705,"libraryId":5,"type":15,"typeLabel":16,"stem":706,"options":707,"answer":290,"analysis":37},1274212,"民用建筑工程室内装修施工时，不应使用（ ）进行除油和清除旧油漆作业。",[708,710,712,714,716],{"key":20,"text":709,"correct":26},"苯",{"key":24,"text":711,"correct":26},"甲苯",{"key":28,"text":713,"correct":26},"二甲苯",{"key":31,"text":715,"correct":22},"重质苯",{"key":34,"text":717,"correct":26},"汽油",[719,723,726,729,732,735],{"id":720,"name":721,"category":7,"favorite":722},1,"领导干部任职前廉政法规知识测试题",92,{"id":724,"name":725,"category":7,"favorite":720},595,"建筑结构与设备",{"id":727,"name":728,"category":7,"favorite":720},715,"招标采购专业知识与法律法规",{"id":730,"name":731,"category":7,"favorite":720},848,"市政方向-通用基础",{"id":733,"name":734,"category":7,"favorite":8},534,"BIM工程师",{"id":736,"name":734,"category":7,"favorite":8},535]