[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-860-13":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":737},{"id":5,"name":6,"category":7,"favorite":8},860,"(装饰质量)专业管理实务 岗位知识","建筑工程",0,13,50,931,[13,38,53,67,82,97,112,127,142,157,172,186,201,215,229,243,258,273,287,301,315,330,344,358,373,387,401,416,426,440,454,468,482,496,510,524,539,553,567,581,595,609,624,638,652,666,681,696,709,723],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},1274113,2,"多选题","背板为镀铝合金板超薄石材蜂窝板的主要性能（ ）。",[19,23,26,29,33],{"key":20,"text":21,"correct":22},"A","平均隔声量",true,{"key":24,"text":25,"correct":22},"B","热阻",{"key":27,"text":28,"correct":22},"C","面密度",{"key":30,"text":31,"correct":32},"D","抗震性",false,{"key":34,"text":35,"correct":22},"E","螺栓抗拉拔力","ABCE","",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":52,"analysis":37},1274114,"天然大理石板材的技术要求包括（ ）。",[42,44,46,48,50],{"key":20,"text":43,"correct":22},"规格尺寸允许偏差",{"key":24,"text":45,"correct":22},"平面度允许公差",{"key":27,"text":47,"correct":32},"石材的弯曲强度",{"key":30,"text":49,"correct":22},"角度允许公差",{"key":34,"text":51,"correct":22},"外观质量","ABDE",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":66,"analysis":37},1274115,"细木工板的检查评价分类包括（ ）。",[57,59,60,62,64],{"key":20,"text":58,"correct":22},"分等",{"key":24,"text":51,"correct":22},{"key":27,"text":61,"correct":22},"规格尺寸和偏差",{"key":30,"text":63,"correct":22},"板芯质量",{"key":34,"text":65,"correct":32},"防火性能","ABCD",{"id":68,"libraryId":5,"type":15,"typeLabel":16,"stem":69,"options":70,"answer":81,"analysis":37},1274116,"制作木格栅时应先用比较干燥的软质木材，下列符合要求的木材种类有（ ）。",[71,73,75,77,79],{"key":20,"text":72,"correct":32},"桦木",{"key":24,"text":74,"correct":22},"松木",{"key":27,"text":76,"correct":22},"杉木",{"key":30,"text":78,"correct":32},"色木",{"key":34,"text":80,"correct":32},"柞木","BC",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":96,"analysis":37},1274117,"铝合金型材检查结果的判定及处理包括（ ）。",[86,88,90,92,94],{"key":20,"text":87,"correct":22},"化学成分不合格时，判该批不合格",{"key":24,"text":89,"correct":22},"尺寸偏差不合格时，判该批不合格，但允许逐根检验，合格者交货",{"key":27,"text":91,"correct":22},"外观质量不合格时，判该件不合格",{"key":30,"text":93,"correct":22},"力学性能试验结果有任一试样不合格时，应从该批（炉）型材",{"key":34,"text":95,"correct":22},"重复试验结果仍有试样不合格时，则判该批型材不合格，或进行重复热处理，重新取样","ABCDE",{"id":98,"libraryId":5,"type":15,"typeLabel":16,"stem":99,"options":100,"answer":111,"analysis":37},1274118,"内墙涂料种类中乳液型内墙涂料包括（ ）。",[101,103,105,107,109],{"key":20,"text":102,"correct":32},"复层内墙涂料",{"key":24,"text":104,"correct":22},"丙烯酸酯乳胶漆",{"key":27,"text":106,"correct":32},"纤维质内墙涂料",{"key":30,"text":108,"correct":22},"苯一丙乳胶漆",{"key":34,"text":110,"correct":32},"绒面内墙涂料","BD",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":126,"analysis":37},1274119,"石膏板的质量应符合（ ）。",[116,118,120,122,124],{"key":20,"text":117,"correct":22},"《装饰石膏板》JC\u002FT799—2007",{"key":24,"text":119,"correct":22},"《纸面石膏板》GB\u002FT9775—2008",{"key":27,"text":121,"correct":22},"《嵌装式装饰石膏板》JC\u002FT800—2007的规定",{"key":30,"text":123,"correct":32},"《嵌装式装饰石膏板》JC\u002FT800—2008的规定",{"key":34,"text":125,"correct":32},"《纸面石膏板》GB\u002FT9775—2007","ABC",{"id":128,"libraryId":5,"type":15,"typeLabel":16,"stem":129,"options":130,"answer":141,"analysis":37},1274120,"幕墙工程主要材料复试项目包括（ ）。",[131,133,135,137,139],{"key":20,"text":132,"correct":32},"室外管网垫层、管基回填",{"key":24,"text":134,"correct":22},"铝塑复合板的剥离强度",{"key":27,"text":136,"correct":22},"石材的弯曲强度；寒冷地区石材的耐融性能",{"key":30,"text":138,"correct":22},"玻璃幕墙用结构胶的邵氏硬度、标准条件拉伸粘结强度、相容性试验",{"key":34,"text":140,"correct":32},"外墙陶瓷面砖的吸水率","BCD",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":156,"analysis":37},1274121,"塑料装饰板，按结构和断面形式可分为（ ）。",[146,148,150,152,154],{"key":20,"text":147,"correct":22},"平板、波形板",{"key":24,"text":149,"correct":32},"三合板",{"key":27,"text":151,"correct":22},"夹芯板等类型",{"key":30,"text":153,"correct":22},"实体异形断面板",{"key":34,"text":155,"correct":22},"中空异形断面板","ACDE",{"id":158,"libraryId":5,"type":15,"typeLabel":16,"stem":159,"options":160,"answer":171,"analysis":37},1274122,"普通钢卷尺的分度值分为（ ）mm几种。",[161,163,165,167,169],{"key":20,"text":162,"correct":32},"0.5",{"key":24,"text":164,"correct":22},"1",{"key":27,"text":166,"correct":22},"2",{"key":30,"text":168,"correct":32},"5",{"key":34,"text":170,"correct":22},"10","BCE",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":81,"analysis":37},1274123,"整体面层地面平整度采用的检验工具有（ ）。",[176,178,180,182,184],{"key":20,"text":177,"correct":32},"钢直尺",{"key":24,"text":179,"correct":22},"2m靠尺",{"key":27,"text":181,"correct":22},"楔形塞尺",{"key":30,"text":183,"correct":32},"5m通线",{"key":34,"text":185,"correct":32},"坡度尺",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":200,"analysis":37},1274124,"施工作业质量的现场检查方法有（ ）。",[190,192,194,196,198],{"key":20,"text":191,"correct":22},"目测法",{"key":24,"text":193,"correct":32},"经验法",{"key":27,"text":195,"correct":22},"试验法",{"key":30,"text":197,"correct":22},"实测法",{"key":34,"text":199,"correct":32},"送检法","ACD",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":66,"analysis":37},1274125,"钢卷尺按结构一般分为（ ）。",[205,207,209,211,213],{"key":20,"text":206,"correct":22},"摇卷盒式卷尺",{"key":24,"text":208,"correct":22},"自卷式卷尺",{"key":27,"text":210,"correct":22},"制动式卷尺",{"key":30,"text":212,"correct":22},"测深钢卷尺",{"key":34,"text":214,"correct":32},"电动式卷尺",{"id":216,"libraryId":5,"type":15,"typeLabel":16,"stem":217,"options":218,"answer":66,"analysis":37},1274126,"下列信息必须反应在直角尺非工作面的有（ ）。",[219,221,223,225,227],{"key":20,"text":220,"correct":22},"制造厂名",{"key":24,"text":222,"correct":22},"商标",{"key":27,"text":224,"correct":22},"CMC标志",{"key":30,"text":226,"correct":22},"出厂编号",{"key":34,"text":228,"correct":32},"CCC标",{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":66,"analysis":37},1274127,"综合点位排布的规律或设计原则有（ ）。",[233,235,237,239,241],{"key":20,"text":234,"correct":22},"点线呼应原则",{"key":24,"text":236,"correct":22},"直线排布",{"key":27,"text":238,"correct":22},"居中原则",{"key":30,"text":240,"correct":22},"对称布置",{"key":34,"text":242,"correct":32},"板块均分原则",{"id":244,"libraryId":5,"type":15,"typeLabel":16,"stem":245,"options":246,"answer":257,"analysis":37},1274128,"装饰单位现场深化设计师应该熟知的标准规范有（ ）。",[247,249,251,253,255],{"key":20,"text":248,"correct":22},"房屋建筑室内装饰装修制图标准",{"key":24,"text":250,"correct":32},"建设工程项目管理规范",{"key":27,"text":252,"correct":22},"建筑装饰装修工程质量验收规范",{"key":30,"text":254,"correct":32},"建筑同层排水系统技术规程",{"key":34,"text":256,"correct":22},"建筑内部装修设计防火规范","ACE",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":272,"analysis":37},1274129,"某商场项目设计文件中，中庭总高度为30m，该区域内采用10mm厚钢化玻璃全玻璃栏板。人口大厅处有若干无框蚀刻玻璃制作的隔断，规格达1800mmx900mm，最薄处厚度仅为10mm。项目部进行图纸会审的过程中认为上述做法不符合规范要求，而要求变更设计文件。根据背景资料，回答下列1~6问题。 下列建筑部位必须使用安全玻璃的有（ ）。",[262,264,266,268,270],{"key":20,"text":263,"correct":32},"幕墙",{"key":24,"text":265,"correct":32},"落地窗",{"key":27,"text":267,"correct":22},"浴室隔断",{"key":30,"text":269,"correct":22},"用于承受行人行走的地面板",{"key":34,"text":271,"correct":22},"吊顶","CDE",{"id":274,"libraryId":5,"type":15,"typeLabel":16,"stem":275,"options":276,"answer":171,"analysis":37},1274130,"室内装饰单位的深化设计工作开展，应该掌握施工现场很多基本数据，包括（ ）。",[277,279,281,283,285],{"key":20,"text":278,"correct":32},"幕墙安装高度",{"key":24,"text":280,"correct":22},"建筑各层层高",{"key":27,"text":282,"correct":22},"墙面、地面、顶面实际造型和尺寸",{"key":30,"text":284,"correct":32},"排水支管坡度",{"key":34,"text":286,"correct":22},"风管等机电安装构件的实际高度",{"id":288,"libraryId":5,"type":15,"typeLabel":16,"stem":289,"options":290,"answer":36,"analysis":37},1274131,"建筑装饰工程的特点有（ ）。",[291,293,295,297,299],{"key":20,"text":292,"correct":22},"装饰材料多",{"key":24,"text":294,"correct":22},"各装饰工艺的质量问题也不尽相同",{"key":27,"text":296,"correct":22},"装饰面层与基层连接方式多样化",{"key":30,"text":298,"correct":32},"施工工艺与土建工程相似",{"key":34,"text":300,"correct":22},"同一种装饰材料的表现方式迥异",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":126,"analysis":37},1274132,"属于装饰工程现场深化设计师个人专业能力的要求有（ ）。",[305,307,309,311,313],{"key":20,"text":306,"correct":22},"必须具备基本的室内设计基础知识",{"key":24,"text":308,"correct":22},"掌握通用的绘图软件AutoCAD及制图规范",{"key":27,"text":310,"correct":22},"熟悉常用的设计标准、技术规范",{"key":30,"text":312,"correct":32},"熟悉装饰材料的生产加工工艺",{"key":34,"text":314,"correct":32},"对于常规的装饰施工工艺不一定非要了解",{"id":316,"libraryId":5,"type":15,"typeLabel":16,"stem":317,"options":318,"answer":329,"analysis":37},1274133,"室内装饰单位深化设计的主要内容有（ ）。",[319,321,323,325,327],{"key":20,"text":320,"correct":22},"补充装饰施工图连接构造节点覆盖面和深度不够的深化设计",{"key":24,"text":322,"correct":22},"综合点位布置图的深化设计",{"key":27,"text":324,"correct":32},"通过深化设计减少材料损耗，有利于项目成本控制",{"key":30,"text":326,"correct":32},"防火门的设计深化",{"key":34,"text":328,"correct":22},"对不符合设计规范及施工技术规范的深化设计","ABE",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":141,"analysis":37},1274134,"下列关于墙面保温薄抹灰施工中，网格布铺设的技术要点，正确的有（ ）。",[334,336,338,340,342],{"key":20,"text":335,"correct":32},"当网格布需要拼接时，搭接宽度应不小于50mm",{"key":24,"text":337,"correct":22},"在阳角处需从每边双向绕角且相互搭接宽度不小于100mm",{"key":27,"text":339,"correct":22},"当遇门窗洞口，应在洞口四角处沿45°方向补贴一块200mm×300mm标准网格布",{"key":30,"text":341,"correct":22},"分格缝处，网布相互搭接",{"key":34,"text":343,"correct":32},"网格布应自下而上沿外墙一圈一圈铺设",{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":171,"analysis":37},1274135,"下列关于室内装修防火施工要点的说法，正确的有（ ）。",[348,350,352,354,356],{"key":20,"text":349,"correct":32},"木质材料在进行阻燃处理时，木质材料含水率不应大于8%",{"key":24,"text":351,"correct":22},"木质材料表面进行防火涂料处理时，涂刷防火涂料用量不应少于500g\u002F㎡",{"key":27,"text":353,"correct":22},"装修施工过程中，应对各装修部位的施工过程作详细记录",{"key":30,"text":355,"correct":32},"防火门的表面加装贴面材料或其他装修时，所用贴面材料的燃烧性能等级不应低于B级",{"key":34,"text":357,"correct":22},"现场阻燃处理后的复合材料应进行抽样检验，每种取4㎡检验燃烧性能",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":372,"analysis":37},1274136,"抹灰工程施工过程中，为解决出现空鼓、开裂的质量问题，采取的措施有（ ）。",[362,364,366,368,370],{"key":20,"text":363,"correct":32},"砂子采用平均粒径0.35mm以下的细砂",{"key":24,"text":365,"correct":22},"施工前进行基体的清理和浇水",{"key":27,"text":367,"correct":32},"使用不同品种的水泥混用",{"key":30,"text":369,"correct":22},"施工操作时分层分遍认真压实",{"key":34,"text":371,"correct":22},"施工后及时浇水养护","BDE",{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":66,"analysis":37},1274137,"下列关于瓷质砖湿贴施工易产生空鼓的原因分析，说法正确的有（ ）。",[377,379,381,383,385],{"key":20,"text":378,"correct":22},"基层墙面变形",{"key":24,"text":380,"correct":22},"粘结砂浆硬化时缺水",{"key":27,"text":382,"correct":22},"基层未清理干净",{"key":30,"text":384,"correct":22},"水泥等粘结材料的质量不合格",{"key":34,"text":386,"correct":32},"粘结砂浆达到一定强度后洒水养护7d",{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":389,"options":390,"answer":329,"analysis":37},1274138,"下列关于木扶手安装技术要点的说法，正确的有（ ）。",[391,393,395,397,399],{"key":20,"text":392,"correct":22},"安装前检查固定木扶手的扁钢是否牢固、平顺",{"key":24,"text":394,"correct":22},"首先安装底层起步弯头和上一层平台弯头，再拉通线，保证斜率",{"key":27,"text":396,"correct":32},"试安装扶手达到要求后，用木螺钉固定木扶手，螺钉间距宜小于1000mm",{"key":30,"text":398,"correct":32},"木扶手断面宽度或高度超过100mm时，宜做暗榫加固",{"key":34,"text":400,"correct":22},"木扶手与墙、柱连接必须牢固",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":415,"analysis":37},1274139,"某项目进行地面环氧自流平面层的施工，项目部进行施工方案的编制。主要内容包括：施工温度控制在5~35℃，相对湿度不宜高于85％；自流平施工前先进行地面基层的整平工作，平整度不应大于4mm\u002F2；采用石膏基自流平砂浆作为找平层等。监理工程师提出问题，要求修改。根据背景资料，回答下列1~6问题。 下列关于自流平面层允许偏差和检验方法的说法，正确的有（ ）。",[405,407,409,411,413],{"key":20,"text":406,"correct":22},"表面平整度允许偏差为2mm，验收时用2m靠尺配合楔形塞尺进行检查",{"key":24,"text":408,"correct":32},"表面平整度允许偏差为3mm，验收时拉5m通线配合钢直尺进行检查",{"key":27,"text":410,"correct":32},"缝格平直度允许偏差为2mm，验收时用2m靠尺配合楔形塞尺进行检查",{"key":30,"text":412,"correct":32},"缝格平直度允许偏差为3mm，验收时用2m靠尺配合楔形塞尺进行检查",{"key":34,"text":414,"correct":22},"缝格平直度允许偏差为3mm，验收时拉5m通线配合钢直尺进行检查","AE",{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":141,"analysis":37},1274140,"下列关于墙面保温薄抹灰施工网格布铺设的技术要点，正确的有（ ）。",[420,421,423,424,425],{"key":20,"text":335,"correct":32},{"key":24,"text":422,"correct":22},"在阳角处需从每边双向绕角且相互搭接宽度不小于200mm",{"key":27,"text":339,"correct":22},{"key":30,"text":341,"correct":22},{"key":34,"text":343,"correct":32},{"id":427,"libraryId":5,"type":15,"typeLabel":16,"stem":428,"options":429,"answer":126,"analysis":37},1274141,"实木地板铺设时，木方、垫木及胶合板等必须进行处理的内容有（ ）。",[430,432,434,436,438],{"key":20,"text":431,"correct":22},"防腐",{"key":24,"text":433,"correct":22},"防虫",{"key":27,"text":435,"correct":22},"防火",{"key":30,"text":437,"correct":32},"防裂",{"key":34,"text":439,"correct":32},"防碱",{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":66,"analysis":37},1274142,"大理石墙、柱面饰面接缝不平、板面纹理不顺、色泽不匀的原因分析正确的是（ ）。",[444,446,448,450,452],{"key":20,"text":445,"correct":22},"基层处理不符合质量要求",{"key":24,"text":447,"correct":22},"对板材质量的检验不严格",{"key":27,"text":449,"correct":22},"镶贴前试拼不认真",{"key":30,"text":451,"correct":22},"施工操作不当，特别是分次灌浆时，灌浆高度过低",{"key":34,"text":453,"correct":32},"未进行浇水养护，且养护时间不足7d",{"id":455,"libraryId":5,"type":15,"typeLabel":16,"stem":456,"options":457,"answer":126,"analysis":37},1274143,"下列关于地毯铺设的技术要点，说法正确的有（ ）。",[458,460,462,464,466],{"key":20,"text":459,"correct":22},"每段地毯裁剪尺寸应比房间长度长20~30mm",{"key":24,"text":461,"correct":22},"簇绒和植绒类地毯裁剪时，相邻两裁口边应呈八字形",{"key":27,"text":463,"correct":22},"采用卡条固定地毯时，应沿房间的四周靠墙壁脚10~20mm处将卡条固定于基层上",{"key":30,"text":465,"correct":32},"卡条可用水泥钉固定在基层上，钉距为500mm左右",{"key":34,"text":467,"correct":32},"铺设弹性衬垫应将胶粒或波形面朝上",{"id":469,"libraryId":5,"type":15,"typeLabel":16,"stem":470,"options":471,"answer":171,"analysis":37},1274144,"下列施工作业在工程划分时，可以划人细部工程的有（ ）施工作业。",[472,474,476,478,480],{"key":20,"text":473,"correct":32},"门窗",{"key":24,"text":475,"correct":22},"窗巾盒",{"key":27,"text":477,"correct":22},"踢脚线",{"key":30,"text":479,"correct":32},"楼梯踏步砖铺贴",{"key":34,"text":481,"correct":22},"窗台板",{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":171,"analysis":37},1274145,"进人施工现场的装修材料应核查其（ ）等技术文件是否符合防火设计要求。",[486,488,490,492,494],{"key":20,"text":487,"correct":32},"A.燃烧性能",{"key":24,"text":489,"correct":22},"防火性能型式检验报告",{"key":27,"text":491,"correct":22},"耐火极限",{"key":30,"text":493,"correct":32},"挥发性有机化合物（VO",{"key":34,"text":495,"correct":22},"合格证书",{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":96,"analysis":37},1274146,"工程质量事故常见的成因包括（ ）。",[500,502,504,506,508],{"key":20,"text":501,"correct":22},"违背建设程序",{"key":24,"text":503,"correct":22},"地质勘查失误",{"key":27,"text":505,"correct":22},"设计差错",{"key":30,"text":507,"correct":22},"使用不合格的原材料、制品及设备",{"key":34,"text":509,"correct":22},"自然环境因素",{"id":511,"libraryId":5,"type":15,"typeLabel":16,"stem":512,"options":513,"answer":156,"analysis":37},1274147,"下列关于楼梯护栏和扶手安装技术要点，说法正确的有（ ）。",[514,516,518,520,522],{"key":20,"text":515,"correct":22},"临空高度在24m以下时，栏杆高度不应低于1.05m",{"key":24,"text":517,"correct":32},"临空高度在24m及以上时，栏杆高度不应低于1.05m",{"key":27,"text":519,"correct":22},"如底部有宽度≥0．22，且高度≤0.45m的可踏部位，栏杆高度应从可踏部位顶面起计算",{"key":30,"text":521,"correct":22},"幼儿园、中小学专用活动场所，护栏竖向杆件净距不应大于0.11m",{"key":34,"text":523,"correct":22},"栏杆离楼面或屋面0.10m高度内不宜留空",{"id":525,"libraryId":5,"type":15,"typeLabel":16,"stem":526,"options":527,"answer":538,"analysis":37},1274148,"下列关于地砖铺贴后擦缝、勾缝的说法，正确的有（ ）。",[528,530,532,534,536],{"key":20,"text":529,"correct":32},"地砖铺贴后应在12h内进行擦缝、勾缝",{"key":24,"text":531,"correct":32},"缝宽小于5mm的擦缝采用相近颜色的专用填缝剂填缝",{"key":27,"text":533,"correct":22},"缝宽在8mm以上的采用勾缝，勾缝采用1:1水泥和细砂浆",{"key":30,"text":535,"correct":22},"勾缝时嵌缝要密实、平整、光滑，缝成圆弧形",{"key":34,"text":537,"correct":32},"勾缝时，嵌缝要凹进面砖外表面5mm","CD",{"id":540,"libraryId":5,"type":15,"typeLabel":16,"stem":541,"options":542,"answer":52,"analysis":37},1274149,"下列关于混凝土整体楼地面施工技术要求的说法，正确的有（ ）。",[543,545,547,549,551],{"key":20,"text":544,"correct":22},"水泥强度等级不得小于32.5级",{"key":24,"text":546,"correct":22},"粗骨料最大粒径不大于垫层厚度的2\u002F3",{"key":27,"text":548,"correct":32},"混凝土面层的强度不低于C15",{"key":30,"text":550,"correct":22},"混凝土垫层的强度不低于C15",{"key":34,"text":552,"correct":22},"砂应采用中粗砂，不得含有黏土、草根等物",{"id":554,"libraryId":5,"type":15,"typeLabel":16,"stem":555,"options":556,"answer":66,"analysis":37},1274150,"木门窗安装检验批的主控项目包括（ ）。",[557,559,561,563,565],{"key":20,"text":558,"correct":22},"木门窗的品种、规格、安装位置",{"key":24,"text":560,"correct":22},"木门窗框的安装必须牢固",{"key":27,"text":562,"correct":22},"木门窗扇安装",{"key":30,"text":564,"correct":22},"木门窗配件安装",{"key":34,"text":566,"correct":32},"缝隙填嵌材料",{"id":568,"libraryId":5,"type":15,"typeLabel":16,"stem":569,"options":570,"answer":96,"analysis":37},1274151,"干粘石饰面空鼓的原因分析（ ）。",[571,573,575,577,579],{"key":20,"text":572,"correct":22},"砖墙面灰尘太多或粘在墙面上的灰浆、泥浆等污物未清理干净",{"key":24,"text":574,"correct":22},"混凝土基层表面太光滑或残留的隔离剂未清理干净，混凝土基层表面有空鼓、硬皮等未处理",{"key":27,"text":576,"correct":22},"加气混凝土基层表面粉尘细灰清理不干净，抹灰砂浆强度过高而加气混凝土本身强度较低，二者收缩不一致",{"key":30,"text":578,"correct":22},"施工前基层不浇水或浇水不适当：浇水过多易流，浇水不足易干，浇水不均产生干缩不均，或脱水快而干缩",{"key":34,"text":580,"correct":22},"冬期施工时抹灰层受冻",{"id":582,"libraryId":5,"type":15,"typeLabel":16,"stem":583,"options":584,"answer":52,"analysis":37},1274152,"玻璃护栏及扶手分项工程中，关于玻璃的选用，说法正确的有（ ）。",[585,587,589,591,593],{"key":20,"text":586,"correct":22},"不承受水平荷载的栏板玻璃，可以使用公称厚度为8mm的钢化玻璃",{"key":24,"text":588,"correct":22},"不承受水平荷载的栏板玻璃，可以使用公称厚度为6.38mm的夹层玻璃",{"key":27,"text":590,"correct":32},"承受水平荷载的栏板玻璃，可以使用公称厚度为10mm的钢化玻璃",{"key":30,"text":592,"correct":22},"承受水平荷载的栏板玻璃，可以使用公称厚度为16．76mm的夹层玻璃",{"key":34,"text":594,"correct":22},"当栏板玻璃最低点离一侧楼地面高度大于5m时，不得使用承受水平荷载的栏板玻璃",{"id":596,"libraryId":5,"type":15,"typeLabel":16,"stem":597,"options":598,"answer":52,"analysis":37},1274153,"轻质隔墙工程又分为（ ）工程。",[599,601,603,605,607],{"key":20,"text":600,"correct":22},"板材隔墙",{"key":24,"text":602,"correct":22},"骨架隔墙",{"key":27,"text":604,"correct":32},"固定隔墙",{"key":30,"text":606,"correct":22},"玻璃隔墙",{"key":34,"text":608,"correct":22},"活动隔墙",{"id":610,"libraryId":5,"type":15,"typeLabel":16,"stem":611,"options":612,"answer":623,"analysis":37},1274154,"板材隔墙分项工程检验批质量检测的主控项目包括（ ）。",[613,615,617,619,621],{"key":20,"text":614,"correct":22},"板材品种、规格、性能",{"key":24,"text":616,"correct":22},"预埋件、连接件",{"key":27,"text":618,"correct":32},"安装位置",{"key":30,"text":620,"correct":32},"表面质量",{"key":34,"text":622,"correct":32},"孔洞、槽、盒","AB",{"id":625,"libraryId":5,"type":15,"typeLabel":16,"stem":626,"options":627,"answer":96,"analysis":37},1274155,"木门窗玻璃装完后松动或不完整的防治措施包括（ ）。",[628,630,632,634,636],{"key":20,"text":629,"correct":22},"必须将裁口上的一切杂物事先清扫干净",{"key":24,"text":631,"correct":22},"裁口内铺垫的底油灰厚薄应均匀一致，不得漏铺",{"key":27,"text":633,"correct":22},"玻璃尺寸按设计裁割，且保证玻璃每边镶人裁口应不少于裁口的3\u002F4",{"key":30,"text":635,"correct":22},"保证钉子数量每边不少于1颗；但边长若超过40cm，至少钉两颗，间距不得大于20cm",{"key":34,"text":637,"correct":22},"当出现安装好的玻璃有不平整、不牢固，程度轻微时，可以挤入底油灰，达到不松动即可",{"id":639,"libraryId":5,"type":15,"typeLabel":16,"stem":640,"options":641,"answer":96,"analysis":37},1274156,"明龙骨吊顶分项工程检验批质量检验方法包括（ ）。",[642,644,646,648,650],{"key":20,"text":643,"correct":22},"尺量检查",{"key":24,"text":645,"correct":22},"检查产品合格证书、性能检测报告和进场验收记录",{"key":27,"text":647,"correct":22},"手扳检查",{"key":30,"text":649,"correct":22},"检查产品合格证书、进场验收记录和隐蔽工程验收记录",{"key":34,"text":651,"correct":22},"检测隐蔽工程验收记录和施工记录",{"id":653,"libraryId":5,"type":15,"typeLabel":16,"stem":654,"options":655,"answer":329,"analysis":37},1274157,"某办公楼装修项目施工，地面为有防静电要求的活动地板面层；顶面采用轻钢龙骨安装矿棉板吊顶面层（龙骨可见）；墙面为轻钢龙骨石膏板隔墙涂刷乳胶漆面层；一侧墙面安装有固定壁柜、吊柜等。项目部施工完成后，经自检合格后，报请监理工程师进行根据背景资料，回答下列1~6问题。 该项目中，需要进行隐蔽工程验收的项目有（ ）。",[656,658,660,662,664],{"key":20,"text":657,"correct":22},"吊顶内管道、设备的安装及水管试压",{"key":24,"text":659,"correct":22},"轻钢龙骨隔墙中边框龙骨与基体连接的牢固度",{"key":27,"text":661,"correct":32},"矿棉板安装的允许偏差",{"key":30,"text":663,"correct":32},"活动地板中的游离甲醛含量",{"key":34,"text":665,"correct":22},"橱柜安装预埋件的数量、规格、位置等",{"id":667,"libraryId":5,"type":15,"typeLabel":16,"stem":668,"options":669,"answer":680,"analysis":37},1274158,"铝合金不顺直的原因分析包括（ ）。",[670,672,674,676,678],{"key":20,"text":671,"correct":32},"吊顶栅格分格过大，板块易产生挠度变形",{"key":24,"text":673,"correct":22},"测吊顶的水平线误差超差，中间平线起拱度不符合规定",{"key":27,"text":675,"correct":22},"未拉通线全面调整主龙骨、次龙骨的高低位置",{"key":30,"text":677,"correct":22},"挂铅线或镀锌铁丝的射钉位置不正确，拉牵力不均匀",{"key":34,"text":679,"correct":22},"主龙骨、次龙骨受扭折，虽经修正，仍不平直","BCDE",{"id":682,"libraryId":5,"type":15,"typeLabel":16,"stem":683,"options":684,"answer":695,"analysis":37},1274159,"下列属于吊顶工程质量通病的是（ ）。",[685,687,689,691,693],{"key":20,"text":686,"correct":22},"吊杆、龙骨和饰面材料安装不牢固",{"key":24,"text":688,"correct":32},"金属吊杆、龙骨的接缝均匀，角缝不吻合，表面不平整、翘曲、有锤印；木质吊杆、龙骨不顺直、劈裂、变形",{"key":27,"text":690,"correct":22},"吊顶内填充的吸声材料无防散落措施",{"key":30,"text":692,"correct":32},"饰面材料表面干净、色泽不一致、有翘曲、裂纹及缺损",{"key":34,"text":694,"correct":32},"护栏安装不牢固、护栏和扶手转角弧度不顺","AC",{"id":697,"libraryId":5,"type":15,"typeLabel":16,"stem":698,"options":699,"answer":36,"analysis":37},1274160,"一般抹灰层粘结及面层质量的检验方法包括（ ）。",[700,702,704,706,708],{"key":20,"text":701,"correct":22},"观察",{"key":24,"text":703,"correct":22},"用小锤轻击检查",{"key":27,"text":705,"correct":22},"检查施工记录",{"key":30,"text":707,"correct":32},"手摸检查",{"key":34,"text":643,"correct":22},{"id":710,"libraryId":5,"type":15,"typeLabel":16,"stem":711,"options":712,"answer":272,"analysis":37},1274161,"现浇水磨石地面分格显露不清的原因分析包括（ ）。",[713,715,717,719,721],{"key":20,"text":714,"correct":32},"基层清理不干净或浇水湿润不够，造成垫层和基层脱离",{"key":24,"text":716,"correct":32},"面层水泥石子浆铺设厚度过低，使分格条难以磨出",{"key":27,"text":718,"correct":22},"铺好面层后，磨石不及时，水泥石子面层强度过高（亦称“过老”），使分格条难以磨出",{"key":30,"text":720,"correct":22},"第一遍磨光时，所用的磨石号数过大，磨损量过小，不易磨出分格条",{"key":34,"text":722,"correct":22},"磨光时用水量过大，使磨石机的磨石在水中呈飘浮状态，这时磨损量也极小",{"id":724,"libraryId":5,"type":15,"typeLabel":16,"stem":725,"options":726,"answer":538,"analysis":37},1274162,"内墙和顶棚涂料涂层色淡易掉粉的原因分析包括（ ）。",[727,729,731,733,735],{"key":20,"text":728,"correct":32},"控制好骨料稠度，专人负责搅拌",{"key":24,"text":730,"correct":32},"基层应干湿一致",{"key":27,"text":732,"correct":22},"使用涂料时未搅拌均匀",{"key":30,"text":734,"correct":22},"涂料质量不合标准，耐水性能不合格",{"key":34,"text":736,"correct":32},"停歇前，应有专人作好未成活部位的遮挡工作，若已溅上骨料应及时清除",[738,742,745,748,751,754],{"id":739,"name":740,"category":7,"favorite":741},1,"领导干部任职前廉政法规知识测试题",92,{"id":743,"name":744,"category":7,"favorite":739},595,"建筑结构与设备",{"id":746,"name":747,"category":7,"favorite":739},715,"招标采购专业知识与法律法规",{"id":749,"name":750,"category":7,"favorite":739},848,"市政方向-通用基础",{"id":752,"name":753,"category":7,"favorite":8},534,"BIM工程师",{"id":755,"name":753,"category":7,"favorite":8},535]