[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1272941":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1272941,859,2,"多选题","某项目走廊进行地面砖面层的铺贴施工，走廊长度为9mx1.8m全部采用600mm×600m瓷质砖，采用15~20mm厚1:2干硬性砂浆结合层，上面涂刮5mm厚的水泥胶粘料，按模数化铺贴。监理方进行检查后发现该走廊有5块瓷砖出现空鼓，要求项目部进行整改。根据背景资料，回答下列1~6问题。 下列关于地砖面层验收时，允许偏差和检查方法的说法，正确的有（ ）。",[11,15,18,22,25],{"key":12,"text":13,"correct":14},"A","表面平整度允许偏差2mm，采用2m靠尺及楔形塞尺进行检查",true,{"key":16,"text":17,"correct":14},"B","缝格平直允许偏差3mm，采用拉5m线及钢直尺进行检查",{"key":19,"text":20,"correct":21},"C","接缝高低差允许偏差1mm，采用钢直尺和楔形塞尺进行检查",false,{"key":23,"text":24,"correct":14},"D","踢脚线上口平直度允许偏差3mm，采用拉5m线及钢直尺进行检查",{"key":26,"text":27,"correct":14},"E","板块间隙宽度允许偏差2mm，采用钢直尺进行检查","ABDE","关于地砖面层验收时，允许偏差和检查方法：①表面平整度允许偏差2mm，采用2m靠尺及楔形塞尺进行检查；②缝格平直允许偏差3mm，采用拉5m线及钢直尺进行检查；③踢脚线上口平直度允许偏差3mm，采用拉5m线及钢直尺进行检查；④板块间隙宽度允许偏差2mm，采用钢直尺进行检查。",{"id":6,"name":31,"category":32,"favorite":33},"(装饰质量)基础知识","建筑工程",0]