[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-858-27":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":708},{"id":5,"name":6,"category":7,"favorite":8},858,"(土建质量)专业管理实务 岗位知识","建筑工程",0,27,50,1473,[13,38,53,68,83,97,112,126,141,155,170,185,199,213,228,238,253,267,281,295,310,324,339,353,367,378,393,404,413,422,436,450,465,477,490,503,517,531,545,559,573,587,599,613,627,639,652,666,680,694],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},1272003,2,"多选题","木结构工程各类构件制作时及构件进场时木材的平均含水率，应符合下列规定：（ ）。",[19,23,27,30,33],{"key":20,"text":21,"correct":22},"A","原木或方木不应大于30％",false,{"key":24,"text":25,"correct":26},"B","原木或方木不应大于25％",true,{"key":28,"text":29,"correct":26},"C","板材及规格材不应大于20%",{"key":31,"text":32,"correct":26},"D","受拉构件的连接板不应大于18％",{"key":34,"text":35,"correct":26},"E","处于通风条件不畅环境下的木构件的木材，不应大于20％","BCDE","",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":52,"analysis":37},1272004,"保温材料的（ ），必须符合设计要求。",[42,44,46,48,50],{"key":20,"text":43,"correct":26},"导热系数",{"key":24,"text":45,"correct":26},"表观密度或干密度",{"key":28,"text":47,"correct":26},"抗压强度或压缩强度",{"key":31,"text":49,"correct":22},"抗拉强度",{"key":34,"text":51,"correct":26},"燃烧性能","ABCE",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":67,"analysis":37},1272005,"密封防水部位的基层应符合下列要求：（ ）。",[57,59,61,63,65],{"key":20,"text":58,"correct":26},"基层应牢固，表面应平整、密实，不得有裂缝、蜂窝、麻面、起皮和起砂现象",{"key":24,"text":60,"correct":22},"基层混凝土强度不得小于C30",{"key":28,"text":62,"correct":26},"基层应清洁、干燥，并应无油污、无灰尘",{"key":31,"text":64,"correct":26},"嵌人的背衬材料与接缝壁间不得留有空隙",{"key":34,"text":66,"correct":26},"密封防水部位的基层宜涂刷基层处理剂，涂刷应均匀，不得漏涂","ACDE",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":82,"analysis":37},1272006,"屋面工程质量验收规范规定冷粘法铺贴卷材应符合下列规定：（ ）。",[72,74,76,78,80],{"key":20,"text":73,"correct":26},"胶粘剂涂刷应均匀，不应露底，不应堆积",{"key":24,"text":75,"correct":26},"应控制胶粘剂涂刷与卷材铺贴的间隔时间",{"key":28,"text":77,"correct":26},"卷材下面的空气应排尽，并应辊压粘贴牢固",{"key":31,"text":79,"correct":26},"卷材铺贴应平整顺直，搭接尺寸应准确，不得扭曲、皱折接缝口应用密封材料封严，宽度不应小于10mm",{"key":34,"text":81,"correct":22},"粘贴卷材时，应随刮随铺，并应展平压实","ABCD",{"id":84,"libraryId":5,"type":15,"typeLabel":16,"stem":85,"options":86,"answer":82,"analysis":37},1272007,"屋面工程的主要功能是（ ）。",[87,89,91,93,95],{"key":20,"text":88,"correct":26},"排水",{"key":24,"text":90,"correct":26},"防水",{"key":28,"text":92,"correct":26},"保温",{"key":31,"text":94,"correct":26},"隔热",{"key":34,"text":96,"correct":22},"承重",{"id":98,"libraryId":5,"type":15,"typeLabel":16,"stem":99,"options":100,"answer":111,"analysis":37},1272008,"（ ）是屋面工程的细部工程。",[101,103,105,107,109],{"key":20,"text":102,"correct":26},"檐沟和天沟",{"key":24,"text":104,"correct":26},"女儿墙和山墙",{"key":28,"text":106,"correct":22},"水落管",{"key":31,"text":108,"correct":26},"变形缝",{"key":34,"text":110,"correct":26},"檐口","ABDE",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":125,"analysis":37},1272009,"屋面工程质量验收规范规定热粘法铺贴卷材应符合下列规定：（ ）。",[116,117,119,121,123],{"key":20,"text":75,"correct":22},{"key":24,"text":118,"correct":26},"熔化热熔型改性沥青胶结料时，宜采用专用导热油炉加热，加热温度不应高于200℃，使用温度不宜低于180℃",{"key":28,"text":120,"correct":26},"粘贴卷材的热熔型改性沥青胶结料厚度宜为1.0～1.5mm",{"key":31,"text":122,"correct":26},"采用热熔型改性沥青胶结料粘贴卷材时，应随刮随铺，并应展平压实",{"key":34,"text":124,"correct":22},"卷材表面热熔后应立即滚铺，卷材下面的空气应排尽，并应辊压粘贴牢固","BCD",{"id":127,"libraryId":5,"type":15,"typeLabel":16,"stem":128,"options":129,"answer":140,"analysis":37},1272010,"屋面工程检验批质量验收合格应符合下列规定：（ ）。",[130,132,134,136,138],{"key":20,"text":131,"correct":26},"主控项目的质量应经抽查检验合格",{"key":24,"text":133,"correct":26},"一般项目的质量应经抽查检验合格有允许偏差值的项目，其抽查点应有80％及其以上在允许偏差范围内，且最大偏差值不得超过允许偏差值的1.5倍",{"key":28,"text":135,"correct":22},"一般项目的质量应经抽查检验合格有允许偏差值的项目，其抽查点应有90％及其以上在允许偏差范围内，且最大偏差值不得超过允许偏差值的1.2倍",{"key":31,"text":137,"correct":26},"应具有完整的施工操作依据和质量检查记录",{"key":34,"text":139,"correct":22},"应具有屋面系统防火性能的检测报告","ABD",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":82,"analysis":37},1272011,"屋面工程中防水、保温材料进场验收应符合下列规定：（ ）。",[145,147,149,151,153],{"key":20,"text":146,"correct":26},"应根据设计要求对材料的质量证明文件进行检查，并应经监理工程师或建设单位代表确",{"key":24,"text":148,"correct":26},"应对材料的品种、规格、包装、外观和尺寸等进行检查验收，并应经监理工程师或建设单位代表确认，形成相应验收记录",{"key":28,"text":150,"correct":26},"防水、保温材料进场检验项目及材料标准应符合屋面工程质量验收规范的规定。材料进场检验应执行见证取样送检制度，并应提出进场检验报告",{"key":31,"text":152,"correct":26},"进场检验报告的全部项目指标均达到技术标准规定应为合格不合格材料不得在工程中使用",{"key":34,"text":154,"correct":22},"进场材料应抽样对防火性能进行检测，并在合格后方可使用",{"id":156,"libraryId":5,"type":15,"typeLabel":16,"stem":157,"options":158,"answer":169,"analysis":37},1272012,"《屋面工程质量验收规范》GB50207涉及（ ）等问题。",[159,161,163,165,167],{"key":20,"text":160,"correct":26},"质量管理",{"key":24,"text":162,"correct":26},"材料",{"key":28,"text":164,"correct":26},"设计",{"key":31,"text":166,"correct":22},"监理",{"key":34,"text":168,"correct":22},"勘察","ABC",{"id":171,"libraryId":5,"type":15,"typeLabel":16,"stem":172,"options":173,"answer":184,"analysis":37},1272013,"屋面工程中瓦材及防水垫层的质量，应符合设计要求。其检验方法为检查（ ）。",[174,176,178,180,182],{"key":20,"text":175,"correct":26},"出厂合格证",{"key":24,"text":177,"correct":22},"型式检验报告",{"key":28,"text":179,"correct":26},"质量检验报告",{"key":31,"text":181,"correct":26},"进场检验报告",{"key":34,"text":183,"correct":22},"现场抽样检测报告","ACD",{"id":186,"libraryId":5,"type":15,"typeLabel":16,"stem":187,"options":188,"answer":82,"analysis":37},1272014,"建筑地面涂料工程中，涂料进入施工现场时，应有（ ）限量合格的检测报告。",[189,191,193,195,197],{"key":20,"text":190,"correct":26},"苯",{"key":24,"text":192,"correct":26},"甲苯+二甲苯",{"key":28,"text":194,"correct":26},"挥发性有机化合物（VO",{"key":31,"text":196,"correct":26},"游离甲苯一异氰醛酯（TDI）",{"key":34,"text":198,"correct":22},"C02",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":169,"analysis":37},1272015,"建筑地面工程子分部工程观感质量综合评价应检查下列项目（ ）。",[203,205,207,209,211],{"key":20,"text":204,"correct":26},"变形缝、面层分格缝的位置和宽度以及填缝质量应符合规定",{"key":24,"text":206,"correct":26},"室内建筑地面工程按各子分部工程经抽查分别作出评价",{"key":28,"text":208,"correct":26},"楼梯、踏步等工程项目经抽查分别作出评价",{"key":31,"text":210,"correct":22},"吊顶中电线的安装质量",{"key":34,"text":212,"correct":22},"防水层的观感质量评价",{"id":214,"libraryId":5,"type":15,"typeLabel":16,"stem":215,"options":216,"answer":227,"analysis":37},1272016,"浸渍纸层压木质地板面层采用的材料进入施工现场时，应有以下有害物质限量合格的检测报告（ ）。",[217,219,221,223,225],{"key":20,"text":218,"correct":22},"地板中的苯 B.胶中的C02 C.地板中的游离甲醛（释放量或含量）",{"key":24,"text":220,"correct":22},"溶剂型胶粘剂中的挥发性有机化合物（VO",{"key":28,"text":222,"correct":26},"苯、甲苯+二甲苯",{"key":31,"text":224,"correct":26},"水性胶粘剂中的挥发性有机化合物（VO",{"key":34,"text":226,"correct":26},"和游离甲醛","CDE",{"id":229,"libraryId":5,"type":15,"typeLabel":16,"stem":230,"options":231,"answer":227,"analysis":37},1272017,"实木地板、实木集成地板、竹地板面层采用的材料进入施工现场时，应有以下有害物质限量合格的检测报告（ ）。",[232,234,235,236,237],{"key":20,"text":233,"correct":22},"地板中的苯 B.胶中的CO2 C.地板中的游离甲醛（释放量或含量）",{"key":24,"text":220,"correct":22},{"key":28,"text":222,"correct":26},{"key":31,"text":224,"correct":26},{"key":34,"text":226,"correct":26},{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":252,"analysis":37},1272018,"水泥宜采用（ ），不同品种、不同强度等级的水泥不应混用砂应为中粗砂，当采用石屑时，其粒径应为1～5mm，且含泥量不应大于3％防水水泥砂浆采用的砂或石屑，其含泥量不应大于1％。",[242,244,246,248,250],{"key":20,"text":243,"correct":26},"硅酸盐水泥",{"key":24,"text":245,"correct":26},"普通硅酸盐水泥",{"key":28,"text":247,"correct":22},"火山灰水泥",{"key":31,"text":249,"correct":22},"矿渣水泥",{"key":34,"text":251,"correct":22},"硫铝酸盐水泥","AB",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":36,"analysis":37},1272019,"建筑地面工程施工时，各层环境温度的控制应符合材料或产品的技术要求，并应符合下列规定（ ）。",[257,259,261,263,265],{"key":20,"text":258,"correct":22},"混凝土工程施工时，5天的平均温度不得低于0℃",{"key":24,"text":260,"correct":26},"采用掺有水泥、石灰的拌和料铺设以及用石油沥青胶结料铺贴时，不应低于5℃",{"key":28,"text":262,"correct":26},"采用有机胶粘剂粘贴时，不应低于10℃",{"key":31,"text":264,"correct":26},"采用砂、石材料铺设时，不应低于0℃",{"key":34,"text":266,"correct":26},"采用自流平、涂料铺设时，不应低于5℃，也不应高于30℃",{"id":268,"libraryId":5,"type":15,"typeLabel":16,"stem":269,"options":270,"answer":169,"analysis":37},1272020,"建筑地面工程施工质量的检验，应符合下列规定（ ）。",[271,273,275,277,279],{"key":20,"text":272,"correct":26},"基层（各构造层）和各类面层的分项工程的施工质量验收应按每一层次或每层施工段（或变形缝）划分检验批，高层建筑的标准层可按每三层（不足三层按三层计）划分检验批",{"key":24,"text":274,"correct":26},"每检验批应以各子分部工程的基层（各构造层）和各类面层所划分的分项工程按自然间（或标准间）检验，抽查数量应随机检验不应少于3间不足3间，应全数检查其中走廊（过道）应以10延长米为1间，工业厂房（按单跨计）、礼堂、门厅应以两个轴线为1间计算",{"key":28,"text":276,"correct":26},"有防水要求的建筑地面子分部工程的分项工程施工质量每检验批抽查数量应按其房间总数随机检验不应少于4间，不足4间，应全数检查",{"key":31,"text":278,"correct":22},"基层（各构造层）和各类面层的分项工程的施工质量验收应按每一层次或每层施工段（或变形缝）划分检验批，高层建筑的标准层也按每层划分检验批",{"key":34,"text":280,"correct":22},"有防水要求的建筑地面子分部工程的分项工程施工质量每检验批抽查数量应按其房间总数随机检验不应少于3间，不足3间，应全数检查",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":36,"analysis":37},1272021,"检验方法应符合下列规定（ ）。",[285,287,289,291,293],{"key":20,"text":286,"correct":22},"检查裂缝用放大镜或刻度放大镜",{"key":24,"text":288,"correct":26},"检查允许偏差应采用钢尺、1m直尺、2直尺、3m直尺、2m靠尺、楔形塞尺、坡度尺、游标卡尺和水准仪",{"key":28,"text":290,"correct":26},"检查空鼓应采用敲击的方法",{"key":31,"text":292,"correct":26},"检查防水隔离层应采用蓄水方法，蓄水深度最浅处不得小于10mm，蓄水时间不得少于24h检查有防水要求的建筑地面的面层应采用泼水方法",{"key":34,"text":294,"correct":26},"检查各类面层（含不需铺设部分或局部面层）表面的裂纹、脱皮、麻面和起砂等缺陷，应采用观感的方法",{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":297,"options":298,"answer":309,"analysis":37},1272022,"建筑地面的变形缝应按设计要求设置，并应符合下列规定（ ）。",[299,301,303,305,307],{"key":20,"text":300,"correct":22},"建筑地面的沉降缝、伸缝、缩缝和防震缝，不能应与结构相应缝的位置一致",{"key":24,"text":302,"correct":26},"建筑地面的沉降缝、伸缝、缩缝和防震缝，应与结构相应缝的位置一致，且应贯通建筑地面的各构造层",{"key":28,"text":304,"correct":22},"沉降缝和防震缝的宽度应符合设计要求，缝内清理干净，用砂浆材料填嵌后用板封盖",{"key":31,"text":306,"correct":26},"沉降缝和防震缝的宽度应符合设计要求，缝内清理干净，以柔性密封材料填嵌后用板封盖，并应与面层齐平",{"key":34,"text":308,"correct":22},"伸缩缝的宽度应符合设计要求，缝内清理干净，以柔性密封材料填嵌后用板封盖，并应与面层齐平","BD",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":82,"analysis":37},1272023,"建筑地面工程子分部工程质量验收应检查下列工程质量文件和记录（ ）。",[314,316,318,320,322],{"key":20,"text":315,"correct":26},"建筑地面工程设计图纸和变更文件等",{"key":24,"text":317,"correct":26},"原材料的质量合格证明文件、重要材料或产品的进场抽样复验报告",{"key":28,"text":319,"correct":26},"各层的强度等级、密实度等的试验报告和测定记录",{"key":31,"text":321,"correct":26},"各类建筑地面工程施工质量控制文件各构造层的隐蔽验收及其他有关验收文件",{"key":34,"text":323,"correct":22},"竣工图",{"id":325,"libraryId":5,"type":15,"typeLabel":16,"stem":326,"options":327,"answer":338,"analysis":37},1272024,"地面工程检验批的合格标准是（ ）。",[328,330,332,334,336],{"key":20,"text":329,"correct":26},"主控项目要达到规范要求",{"key":24,"text":331,"correct":26},"一般项目80%以上要符合要求",{"key":28,"text":333,"correct":22},"不合格点不得超过允许偏差值的20％",{"key":31,"text":335,"correct":22},"一般项目全部符合规定要求",{"key":34,"text":337,"correct":26},"不合格点不得超过允许偏差值的50％","ABE",{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":252,"analysis":37},1272025,"建筑地面工程子分部工程质量验收应检查下列安全和功能项目（ ）。",[343,345,347,349,351],{"key":20,"text":344,"correct":26},"有防水要求的建筑地面子分部工程的分项工程施工质量的蓄水检验记录，并抽查",{"key":24,"text":346,"correct":26},"建筑地面板块面层铺设子分部工程和木、竹面层铺设子分部工程采用的砖、天然石材、预制板块、地毯、人造板材以及胶粘剂、胶结料、涂料等材料证明及环保资料",{"key":28,"text":348,"correct":22},"泼水试验记录",{"key":31,"text":350,"correct":22},"楼板强度检测报告",{"key":34,"text":352,"correct":22},"混凝土抗渗检测报告",{"id":354,"libraryId":5,"type":15,"typeLabel":16,"stem":355,"options":356,"answer":82,"analysis":37},1272026,"在预制钢筋混凝土板上铺设找平层前，板缝填嵌的施工应符合下列要求（ ）。",[357,359,361,363,365],{"key":20,"text":358,"correct":26},"预制钢筋混凝土板相邻缝底宽不应小于20mm",{"key":24,"text":360,"correct":26},"填嵌时，板缝内应清理干净，保持湿润",{"key":28,"text":362,"correct":26},"填缝应采用细石混凝土，其强度等级不应小于C20。填缝高度应低于板面10～20mm，且振捣密实填缝后应养护。当填缝混凝土的强度等级达到C15后方可继续施工",{"key":31,"text":364,"correct":26},"当板缝底宽大于40mm时，应按设计要求配置钢筋",{"key":34,"text":366,"correct":22},"预制钢筋混凝土板相邻缝底应挤紧",{"id":368,"libraryId":5,"type":15,"typeLabel":16,"stem":369,"options":370,"answer":82,"analysis":37},1272027,"建筑地面工程中绝热层材料进入施工现场时，应对材料的（ ）进行复验。",[371,372,374,375,377],{"key":20,"text":43,"correct":26},{"key":24,"text":373,"correct":26},"表观密度",{"key":28,"text":47,"correct":26},{"key":31,"text":376,"correct":26},"阻燃性",{"key":34,"text":49,"correct":22},{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":392,"analysis":37},1272028,"室内抹灰每个检验批应至少抽查（ ），并不得少于（ ）间不足3间时应全数检查。",[382,384,386,388,390],{"key":20,"text":383,"correct":26},"10％",{"key":24,"text":385,"correct":22},"20％",{"key":28,"text":387,"correct":26},"3",{"key":31,"text":389,"correct":22},"6",{"key":34,"text":391,"correct":22},"10","AC",{"id":394,"libraryId":5,"type":15,"typeLabel":16,"stem":395,"options":396,"answer":309,"analysis":37},1272029,"玻璃隔墙工程的每个检验批应至少抽查（ ），并不得少于（ ）间不足6间时应全数检查。",[397,398,400,401,402],{"key":20,"text":383,"correct":22},{"key":24,"text":399,"correct":26},"20%",{"key":28,"text":387,"correct":22},{"key":31,"text":389,"correct":26},{"key":34,"text":403,"correct":22},"8",{"id":405,"libraryId":5,"type":15,"typeLabel":16,"stem":406,"options":407,"answer":392,"analysis":37},1272030,"吊顶工程的每个检验批应至少抽查（ ），并不得少于（ ）间不足3间时应全数检查。",[408,409,410,411,412],{"key":20,"text":383,"correct":26},{"key":24,"text":385,"correct":22},{"key":28,"text":387,"correct":26},{"key":31,"text":389,"correct":22},{"key":34,"text":403,"correct":22},{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":309,"analysis":37},1272031,"活动隔墙工程的每个检验批应至少抽查（ ），并不得少于（ ）间：不足6间时应全数检查。",[417,418,419,420,421],{"key":20,"text":383,"correct":22},{"key":24,"text":385,"correct":26},{"key":28,"text":387,"correct":22},{"key":31,"text":389,"correct":26},{"key":34,"text":403,"correct":22},{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":424,"options":425,"answer":435,"analysis":37},1272032,"饰面砖粘贴工程适用于内墙饰面砖粘贴工程和高度不大于（ ）m、抗震设防烈度不大于（ ）度、采用满粘法施工的外墙饰面砖粘贴工程的质量验收。",[426,428,430,432,433],{"key":20,"text":427,"correct":26},"100",{"key":24,"text":429,"correct":22},"24",{"key":28,"text":431,"correct":22},"9",{"key":31,"text":403,"correct":26},{"key":34,"text":434,"correct":22},"7","AD",{"id":437,"libraryId":5,"type":15,"typeLabel":16,"stem":438,"options":439,"answer":392,"analysis":37},1272033,"室外抹灰每个检验批每（ ）应至少抽查一处，每处不得少于（ ）。",[440,442,444,446,448],{"key":20,"text":441,"correct":26},"100㎡",{"key":24,"text":443,"correct":22},"200㎡",{"key":28,"text":445,"correct":26},"10㎡",{"key":31,"text":447,"correct":22},"20㎡",{"key":34,"text":449,"correct":22},"300㎡",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":464,"analysis":37},1272034,"立柱和横梁等主要受力构件，其截面受力部分的壁厚应经计算确定，且铝型材不应小于（ ）mm，钢型材不应小于（ ）mm。",[454,456,458,460,462],{"key":20,"text":455,"correct":22},"2.5",{"key":24,"text":457,"correct":26},"3.0",{"key":28,"text":459,"correct":26},"3.5",{"key":31,"text":461,"correct":22},"4.0",{"key":34,"text":463,"correct":22},"5.0","BC",{"id":466,"libraryId":5,"type":15,"typeLabel":16,"stem":467,"options":468,"answer":476,"analysis":37},1272035,"民用建筑工程室内环境污染控制验收抽检代表性房间，有样板间检测的工程抽检数（ ），均不少于（ ）间。",[469,471,473,474,475],{"key":20,"text":470,"correct":22},"2.5％",{"key":24,"text":472,"correct":26},"5％",{"key":28,"text":383,"correct":22},{"key":31,"text":389,"correct":22},{"key":34,"text":387,"correct":26},"BE",{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":479,"options":480,"answer":464,"analysis":37},1272036,"同一品种的轻质隔墙工程每（ ）间[大面积房间和走廊按抹灰面积（为一间〕应划分为一个检验批，不足50间也应划分为一个检验批。",[481,483,485,487,489],{"key":20,"text":482,"correct":22},"30",{"key":24,"text":484,"correct":26},"50",{"key":28,"text":486,"correct":26},"30㎡",{"key":31,"text":488,"correct":22},"50㎡",{"key":34,"text":441,"correct":22},{"id":491,"libraryId":5,"type":15,"typeLabel":16,"stem":492,"options":493,"answer":392,"analysis":37},1272037,"相同材料、工艺和施工条件的室外饰面板（砖）工程（ ）㎡应划分为一个检验批，不足（ ）㎡也应划分为一个检验批。",[494,496,498,500,502],{"key":20,"text":495,"correct":26},"500～1000",{"key":24,"text":497,"correct":22},"1000",{"key":28,"text":499,"correct":26},"500",{"key":31,"text":501,"correct":22},"300",{"key":34,"text":427,"correct":22},{"id":504,"libraryId":5,"type":15,"typeLabel":16,"stem":505,"options":506,"answer":67,"analysis":37},1272038,"Ⅱ类民用建筑工程包括（ ）。",[507,509,511,513,515],{"key":20,"text":508,"correct":26},"办公楼",{"key":24,"text":510,"correct":22},"住宅",{"key":28,"text":512,"correct":26},"商店、旅馆",{"key":31,"text":514,"correct":26},"文化娱乐场所",{"key":34,"text":516,"correct":26},"图书馆、书店等",{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":82,"analysis":37},1272039,"建筑装饰装修工程施工过程中应做好（ ）的保护，防止（ ）。",[521,523,525,527,529],{"key":20,"text":522,"correct":26},"半成品",{"key":24,"text":524,"correct":26},"成品",{"key":28,"text":526,"correct":26},"污染",{"key":31,"text":528,"correct":26},"损坏",{"key":34,"text":530,"correct":22},"损伤物理性能",{"id":532,"libraryId":5,"type":15,"typeLabel":16,"stem":533,"options":534,"answer":392,"analysis":37},1272040,"双层石膏板暗龙骨吊顶，面层与基层板的接缝应（ ），并（ ）同一根龙骨上接缝。",[535,537,539,541,543],{"key":20,"text":536,"correct":26},"错开",{"key":24,"text":538,"correct":22},"对齐",{"key":28,"text":540,"correct":26},"不得在",{"key":31,"text":542,"correct":22},"设在",{"key":34,"text":544,"correct":22},"无要求",{"id":546,"libraryId":5,"type":15,"typeLabel":16,"stem":547,"options":548,"answer":36,"analysis":37},1272041,"龙骨安装前，应按设计要求对（ ）进行交接检验。",[549,551,553,555,557],{"key":20,"text":550,"correct":22},"地面标高",{"key":24,"text":552,"correct":26},"房间净高",{"key":28,"text":554,"correct":26},"洞口标高",{"key":31,"text":556,"correct":26},"吊顶内管道",{"key":34,"text":558,"correct":26},"设备及其支架的标高",{"id":560,"libraryId":5,"type":15,"typeLabel":16,"stem":561,"options":562,"answer":82,"analysis":37},1272042,"吊顶工程应进行隐蔽工程验收的项目为（ ）。",[563,565,567,569,571],{"key":20,"text":564,"correct":26},"吊顶内管道、设备的安装及水管试压",{"key":24,"text":566,"correct":26},"木龙骨防火、防腐处理、吊杆、龙骨安装",{"key":28,"text":568,"correct":26},"预埋件或拉结筋",{"key":31,"text":570,"correct":26},"填充材料的设置",{"key":34,"text":572,"correct":22},"面板的安装",{"id":574,"libraryId":5,"type":15,"typeLabel":16,"stem":575,"options":576,"answer":82,"analysis":37},1272043,"民用建筑工程验收时，必须进行室内环境污染浓度检测，项目有（ ）。",[577,579,581,583,585],{"key":20,"text":578,"correct":26},"氡（Rn-222）",{"key":24,"text":580,"correct":26},"B甲醛",{"key":28,"text":582,"correct":26},"氨",{"key":31,"text":584,"correct":26},"苯和总挥发性有机化合物（TVO",{"key":34,"text":586,"correct":22},"CO2",{"id":588,"libraryId":5,"type":15,"typeLabel":16,"stem":589,"options":590,"answer":52,"analysis":37},1272044,"轻质隔墙工程应对下列隐蔽工程项目进行验收（ ）。",[591,593,595,596,598],{"key":20,"text":592,"correct":26},"骨架隔墙中设备管线的安装及水管试压",{"key":24,"text":594,"correct":26},"龙骨安装、木龙骨防火、防腐处理",{"key":28,"text":568,"correct":26},{"key":31,"text":597,"correct":22},"钢构件的防火",{"key":34,"text":570,"correct":26},{"id":600,"libraryId":5,"type":15,"typeLabel":16,"stem":601,"options":602,"answer":169,"analysis":37},1272045,"见证检测已成为工程质量管理中通行的一种方式，在下述情况下应进行见证检测：（ ）。",[603,605,607,609,611],{"key":20,"text":604,"correct":26},"国家规定应进行见证检测的项目",{"key":24,"text":606,"correct":26},"合同约定进行见证检测的项目",{"key":28,"text":608,"correct":26},"对材料质量发生争议时",{"key":31,"text":610,"correct":22},"产品出厂检验",{"key":34,"text":612,"correct":22},"产品型式检验",{"id":614,"libraryId":5,"type":15,"typeLabel":16,"stem":615,"options":616,"answer":169,"analysis":37},1272046,"建筑装饰装修工程所有材料进场包装应完好，应有（ ）。",[617,619,621,623,625],{"key":20,"text":618,"correct":26},"合格证书",{"key":24,"text":620,"correct":26},"中文说明书",{"key":28,"text":622,"correct":26},"相关性能的检测报告",{"key":31,"text":624,"correct":22},"卫生检验报告",{"key":34,"text":626,"correct":22},"化学分析报告",{"id":628,"libraryId":5,"type":15,"typeLabel":16,"stem":629,"options":630,"answer":252,"analysis":37},1272047,"民用建筑工程室内装修中所采用的水性涂料、水性胶粘剂、水性处理剂必须有同批次产品的（ ）含量检测报告。",[631,633,635,637,638],{"key":20,"text":632,"correct":26},"挥发性有机化合物（VO C）",{"key":24,"text":634,"correct":26},"游离甲醛",{"key":28,"text":636,"correct":22},"游离甲苯一异氰酸酯（Tell）",{"key":31,"text":190,"correct":22},{"key":34,"text":192,"correct":22},{"id":640,"libraryId":5,"type":15,"typeLabel":16,"stem":641,"options":642,"answer":125,"analysis":37},1272048,"饰面板（砖）工程应对下列隐蔽工程项目进行验收（ ）。",[643,645,647,649,651],{"key":20,"text":644,"correct":22},"基层的强度",{"key":24,"text":646,"correct":26},"预埋件（或后置预埋件）",{"key":28,"text":648,"correct":26},"连接节点",{"key":31,"text":650,"correct":26},"防水层",{"key":34,"text":108,"correct":22},{"id":653,"libraryId":5,"type":15,"typeLabel":16,"stem":654,"options":655,"answer":125,"analysis":37},1272049,"民用建筑工程所使用的（ ）等无机非金属建筑主体材料，其放射性指标限量应符合《民用建筑工程室内环境污染控制规范》GB5032-2010的有关规定。",[656,658,660,662,664],{"key":20,"text":657,"correct":22},"建筑钢材",{"key":24,"text":659,"correct":26},"砂、石、砖、水泥",{"key":28,"text":661,"correct":26},"商品混凝土",{"key":31,"text":663,"correct":26},"混凝土预制构件",{"key":34,"text":665,"correct":22},"新型墙体材料",{"id":667,"libraryId":5,"type":15,"typeLabel":16,"stem":668,"options":669,"answer":309,"analysis":37},1272050,"幕墙金属框架与主体结构预埋件，立柱与横梁的连接及幕墙面板的安装必须符合（ ），安装必须（ ）。",[670,672,674,676,678],{"key":20,"text":671,"correct":22},"结构可靠",{"key":24,"text":673,"correct":26},"设计要求",{"key":28,"text":675,"correct":22},"焊接牢固",{"key":31,"text":677,"correct":26},"牢固",{"key":34,"text":679,"correct":22},"美观",{"id":681,"libraryId":5,"type":15,"typeLabel":16,"stem":682,"options":683,"answer":184,"analysis":37},1272051,"适用于厨卫间的腻子的主要成分为（ ）。",[684,686,688,690,692],{"key":20,"text":685,"correct":26},"聚醋酸乙烯乳液",{"key":24,"text":687,"correct":22},"熟桐油",{"key":28,"text":689,"correct":26},"水泥",{"key":31,"text":691,"correct":26},"水",{"key":34,"text":693,"correct":22},"汽油",{"id":695,"libraryId":5,"type":15,"typeLabel":16,"stem":696,"options":697,"answer":169,"analysis":37},1272052,"抹灰层之间易出现（ ）等质量问题。",[698,700,702,704,706],{"key":20,"text":699,"correct":26},"开裂",{"key":24,"text":701,"correct":26},"空鼓",{"key":28,"text":703,"correct":26},"脱落",{"key":31,"text":705,"correct":22},"泛霜",{"key":34,"text":707,"correct":22},"起砂",[709,713,716,719,722,725],{"id":710,"name":711,"category":7,"favorite":712},1,"领导干部任职前廉政法规知识测试题",92,{"id":714,"name":715,"category":7,"favorite":710},595,"建筑结构与设备",{"id":717,"name":718,"category":7,"favorite":710},715,"招标采购专业知识与法律法规",{"id":720,"name":721,"category":7,"favorite":710},848,"市政方向-通用基础",{"id":723,"name":724,"category":7,"favorite":8},534,"BIM工程师",{"id":726,"name":724,"category":7,"favorite":8},535]