[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-858-26":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":713},{"id":5,"name":6,"category":7,"favorite":8},858,"(土建质量)专业管理实务 岗位知识","建筑工程",0,26,50,1473,[13,38,53,68,82,97,112,127,139,153,166,181,192,207,221,236,250,263,274,288,303,315,329,343,357,371,385,395,408,422,436,450,464,478,492,503,517,531,545,559,573,585,599,614,629,643,655,669,683,698],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},1271952,2,"多选题","结构实体检验，当出现下列情况时：（ ），应委托具有相应资质等级的检测机构按国家有关标准的规定进行检测。",[19,23,26,29,33],{"key":20,"text":21,"correct":22},"A","未能取得同条件养护试件强度",true,{"key":24,"text":25,"correct":22},"B","同条件养护试件强度被判为不合格",{"key":27,"text":28,"correct":22},"C","现场混凝土结构构件未按规定养护",{"key":30,"text":31,"correct":32},"D","钢筋保护层厚度不满足要求",false,{"key":34,"text":35,"correct":32},"E","监理工程师有要求时","ABC","",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":52,"analysis":37},1271953,"混凝土试块标准养护的条件是（ ）。",[42,44,46,48,50],{"key":20,"text":43,"correct":32},"温度20±3℃",{"key":24,"text":45,"correct":22},"温度20±2℃",{"key":27,"text":47,"correct":32},"温度30±2℃",{"key":30,"text":49,"correct":32},"相对湿度90％以上",{"key":34,"text":51,"correct":22},"相对湿度95％及以上","BE",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":67,"analysis":37},1271954,"凡（ ）中任一项不符合标准规定时，均为不合格水泥。",[57,59,61,63,65],{"key":20,"text":58,"correct":22},"细度",{"key":24,"text":60,"correct":22},"终凝时间",{"key":27,"text":62,"correct":22},"混合材料超过最大限量",{"key":30,"text":64,"correct":22},"强度低于商品强度等级的指标",{"key":34,"text":66,"correct":22},"水泥包装标志不符合要求","ABCDE",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":81,"analysis":37},1271955,"凡（ ）中任一项不符合标准规定时，均为废品水泥。",[72,74,76,78,80],{"key":20,"text":73,"correct":22},"氧化镁",{"key":24,"text":75,"correct":22},"三氧化硫",{"key":27,"text":77,"correct":22},"初凝时间",{"key":30,"text":79,"correct":22},"安定性",{"key":34,"text":60,"correct":32},"ABCD",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":96,"analysis":37},1271956,"钢材有下列（ ）缺陷，不能用于工程。",[86,88,90,92,94],{"key":20,"text":87,"correct":32},"表面浮锈",{"key":24,"text":89,"correct":22},"屈服强度不合格",{"key":27,"text":91,"correct":22},"抗拉强度不合格",{"key":30,"text":93,"correct":22},"伸长率不合格",{"key":34,"text":95,"correct":22},"冷弯不合格","BCDE",{"id":98,"libraryId":5,"type":15,"typeLabel":16,"stem":99,"options":100,"answer":111,"analysis":37},1271957,"混凝土结构构件的抗震等级根据（ ）确定。",[101,103,105,107,109],{"key":20,"text":102,"correct":32},"混凝土强度",{"key":24,"text":104,"correct":22},"设防烈度",{"key":27,"text":106,"correct":22},"结构类型",{"key":30,"text":108,"correct":22},"房屋高度",{"key":34,"text":110,"correct":32},"基础深度","BCD",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":126,"analysis":37},1271958,"冷轧带肋钢筋力学性能和工艺指标指的是（ ）。",[116,118,120,122,124],{"key":20,"text":117,"correct":22},"抗拉强度",{"key":24,"text":119,"correct":32},"松弛率",{"key":27,"text":121,"correct":22},"伸长率",{"key":30,"text":123,"correct":22},"弯曲试验180°（反复弯曲次数）",{"key":34,"text":125,"correct":32},"屈服强度","ACD",{"id":128,"libraryId":5,"type":15,"typeLabel":16,"stem":129,"options":130,"answer":36,"analysis":37},1271959,"钢筋混凝土用热轧带肋钢筋，钢筋的力学性能包括（ ）。",[131,132,133,135,137],{"key":20,"text":125,"correct":22},{"key":24,"text":121,"correct":22},{"key":27,"text":134,"correct":22},"极限强度",{"key":30,"text":136,"correct":32},"弯曲性能",{"key":34,"text":138,"correct":32},"冷弯",{"id":140,"libraryId":5,"type":15,"typeLabel":16,"stem":141,"options":142,"answer":81,"analysis":37},1271961,"用于检查结构构件混凝土强度的试件，其取样与试件留置应符合下列规定（ ）。",[143,145,147,149,151],{"key":20,"text":144,"correct":22},"每拌制100盘且不超过100m3的同配合比的混凝土，不得少于一次",{"key":24,"text":146,"correct":22},"每工作班拌制的同配合比的混凝土不足100盘，取样不得少于一次",{"key":27,"text":148,"correct":22},"一次连续浇筑超过1000m3时，同配合比混凝土每200m3取样不少于一次",{"key":30,"text":150,"correct":22},"每一楼层，同一配合比的混凝土，取样不得少于一次。每次取样应至少留置一组标准养护试件，同条件养护试件的留置组数应根据实际需要确定",{"key":34,"text":152,"correct":32},"每两个轴线间，取样不少于一次",{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":126,"analysis":37},1271962,"粉煤灰复验时，应做（ ）检验。",[157,158,160,162,164],{"key":20,"text":58,"correct":22},{"key":24,"text":159,"correct":32},"需水量",{"key":27,"text":161,"correct":22},"烧失量",{"key":30,"text":163,"correct":22},"含水量",{"key":34,"text":165,"correct":32},"密度",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":180,"analysis":37},1271963,"常用水泥强度等级是由（ ）d抗压强度和抗折强度确定的。",[170,172,174,176,178],{"key":20,"text":171,"correct":22},"3",{"key":24,"text":173,"correct":32},"7",{"key":27,"text":175,"correct":32},"21",{"key":30,"text":177,"correct":22},"28",{"key":34,"text":179,"correct":32},"42","AD",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":191,"analysis":37},1271964,"钢筋混凝土用热轧带肋钢筋的工艺性能包括（ ）。",[185,186,187,188,190],{"key":20,"text":125,"correct":32},{"key":24,"text":134,"correct":32},{"key":27,"text":136,"correct":22},{"key":30,"text":189,"correct":22},"反向弯曲性能",{"key":34,"text":121,"correct":32},"CD",{"id":193,"libraryId":5,"type":15,"typeLabel":16,"stem":194,"options":195,"answer":206,"analysis":37},1271965,"钢筋进场时，应按国家现行相关标准的规定抽取试件作（ ）检验，检验结果必须符合有关标准的规定。",[196,198,200,202,204],{"key":20,"text":197,"correct":22},"力学性能",{"key":24,"text":199,"correct":22},"重量偏差",{"key":27,"text":201,"correct":32},"直径",{"key":30,"text":203,"correct":32},"机械性能",{"key":34,"text":205,"correct":32},"化学分析","AB",{"id":208,"libraryId":5,"type":15,"typeLabel":16,"stem":209,"options":210,"answer":111,"analysis":37},1271966,"混凝土结构子分部工程可划分为（ ）、预应力、现浇结构和装配式结构分项工程。",[211,213,215,217,219],{"key":20,"text":212,"correct":32},"砌体",{"key":24,"text":214,"correct":22},"模板",{"key":27,"text":216,"correct":22},"钢筋",{"key":30,"text":218,"correct":22},"混凝土",{"key":34,"text":220,"correct":32},"支撑系统",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":235,"analysis":37},1271967,"砌砖工程当采用铺浆法砌筑时，铺浆长度不得超过（ ）施工期间气温超过30℃时，铺浆长度不得超过（ ）。",[225,227,229,231,233],{"key":20,"text":226,"correct":32},"1000",{"key":24,"text":228,"correct":22},"750",{"key":27,"text":230,"correct":22},"500",{"key":30,"text":232,"correct":32},"400",{"key":34,"text":234,"correct":32},"300","BC",{"id":237,"libraryId":5,"type":15,"typeLabel":16,"stem":238,"options":239,"answer":126,"analysis":37},1271968,"普通砌筑砂浆出厂检验项目应为（ ）薄层砌筑砂浆出厂检验项目应为保水率、抗压强度。",[240,242,244,246,248],{"key":20,"text":241,"correct":22},"2b稠度损失率",{"key":24,"text":243,"correct":32},"分层度",{"key":27,"text":245,"correct":22},"抗压强度",{"key":30,"text":247,"correct":22},"保水率",{"key":34,"text":249,"correct":32},"凝结时间",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":191,"analysis":37},1271969,"砂浆应随拌随用，水泥混合砂浆应在（ ）h内使用完毕。当施工期间最高温度超过30℃时，应在拌成后（ ）h内使用完毕。",[254,256,258,260,261],{"key":20,"text":255,"correct":32},"5",{"key":24,"text":257,"correct":32},"4",{"key":27,"text":259,"correct":22},"2",{"key":30,"text":171,"correct":22},{"key":34,"text":262,"correct":32},"1",{"id":264,"libraryId":5,"type":15,"typeLabel":16,"stem":265,"options":266,"answer":191,"analysis":37},1271970,"挡土墙的泄水孔当设计无规定时，施工应符合下列规定：1）泄水孔应均匀设置，在每米高度上间隔2左右设置一个泄水孔2）泄水孔与土体间铺设长宽各为（ ）mm、厚（ ）mm的卵石或碎石作疏水层。",[267,268,269,270,272],{"key":20,"text":230,"correct":32},{"key":24,"text":232,"correct":32},{"key":27,"text":234,"correct":22},{"key":30,"text":271,"correct":22},"200",{"key":34,"text":273,"correct":32},"100",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":111,"analysis":37},1271971,"砖砌体的灰缝应横平竖直，厚薄均匀。水平灰缝厚度宜为（ ）mm，但不应小于（ ）mm，也不应大于（ ）mm。",[278,280,282,284,286],{"key":20,"text":279,"correct":32},"6",{"key":24,"text":281,"correct":22},"10",{"key":27,"text":283,"correct":22},"8",{"key":30,"text":285,"correct":22},"12",{"key":34,"text":287,"correct":32},"15",{"id":289,"libraryId":5,"type":15,"typeLabel":16,"stem":290,"options":291,"answer":302,"analysis":37},1271972,"专用小砌块灌孔混凝土坍落度，不小于180mm，拌合物（ ），故宜采用。",[292,294,296,298,300],{"key":20,"text":293,"correct":22},"不离析",{"key":24,"text":295,"correct":22},"不泌水",{"key":27,"text":297,"correct":32},"强度高",{"key":30,"text":299,"correct":22},"施工性能好",{"key":34,"text":301,"correct":32},"密度低","ABD",{"id":304,"libraryId":5,"type":15,"typeLabel":16,"stem":305,"options":306,"answer":36,"analysis":37},1271973,"砌筑砂浆（ ）必须同时符合要求。",[307,309,310,312,314],{"key":20,"text":308,"correct":22},"稠度",{"key":24,"text":243,"correct":22},{"key":27,"text":311,"correct":22},"试配抗压强度",{"key":30,"text":313,"correct":32},"泌水",{"key":34,"text":245,"correct":32},{"id":316,"libraryId":5,"type":15,"typeLabel":16,"stem":317,"options":318,"answer":36,"analysis":37},1271974,"确保小砌块砌体的砌筑质量，可简单归纳为6个字（ ）。",[319,321,323,325,327],{"key":20,"text":320,"correct":22},"对孔",{"key":24,"text":322,"correct":22},"错缝",{"key":27,"text":324,"correct":22},"反砌",{"key":30,"text":326,"correct":32},"正砌",{"key":34,"text":328,"correct":32},"对缝",{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":331,"options":332,"answer":96,"analysis":37},1271975,"干混砂浆有下列几种（ ）。",[333,335,337,339,341],{"key":20,"text":334,"correct":32},"干混节能砂浆",{"key":24,"text":336,"correct":22},"干混砌筑砂浆",{"key":27,"text":338,"correct":22},"干混抹灰砂浆",{"key":30,"text":340,"correct":22},"干混地面砂浆",{"key":34,"text":342,"correct":22},"干混普通防水砂浆",{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":96,"analysis":37},1271976,"砖砌体施工临时间断处补砌时，必须将接槎处（ ）。",[347,349,351,353,355],{"key":20,"text":348,"correct":32},"高强度砂浆",{"key":24,"text":350,"correct":22},"表面清理干净",{"key":27,"text":352,"correct":22},"洒水湿润",{"key":30,"text":354,"correct":22},"并填实砂浆",{"key":34,"text":356,"correct":22},"保持灰缝平直",{"id":358,"libraryId":5,"type":15,"typeLabel":16,"stem":359,"options":360,"answer":36,"analysis":37},1271977,"当施工中或验收时出现（ ），可采用现场检验方法对砂浆和砌体强度进行原位检测或取样检测，并判定其强度。",[361,363,365,367,369],{"key":20,"text":362,"correct":22},"砂浆试块缺乏代表性",{"key":24,"text":364,"correct":22},"对砂浆试块的试验结果有怀疑或有争议",{"key":27,"text":366,"correct":22},"砂浆试块的试验结果不能满足设计要求",{"key":30,"text":368,"correct":32},"监理工程师认为为了保证质量",{"key":34,"text":370,"correct":32},"有一组砂浆的强度代表值达到设计强度标准的90％",{"id":372,"libraryId":5,"type":15,"typeLabel":16,"stem":373,"options":374,"answer":36,"analysis":37},1271978,"竖向灰缝不得出现（ ）。",[375,377,379,381,383],{"key":20,"text":376,"correct":22},"透明缝",{"key":24,"text":378,"correct":22},"瞎缝",{"key":27,"text":380,"correct":22},"假缝",{"key":30,"text":382,"correct":32},"通缝",{"key":34,"text":384,"correct":32},"无缝",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":394,"analysis":37},1271979,"湿拌砌筑砂浆出厂检验项目为（ ）。",[389,390,391,392,393],{"key":20,"text":308,"correct":22},{"key":24,"text":243,"correct":32},{"key":27,"text":245,"correct":22},{"key":30,"text":247,"correct":22},{"key":34,"text":249,"correct":22},"ACDE",{"id":396,"libraryId":5,"type":15,"typeLabel":16,"stem":397,"options":398,"answer":96,"analysis":37},1271980,"当施工中或验收时出现下列情况，可采用现场检验方法对砂浆或砌体强度进行实体检测，并判定其强度：（ ）。",[399,401,403,404,406],{"key":20,"text":400,"correct":32},"监理工程师有要求",{"key":24,"text":402,"correct":22},"砂浆试块缺乏代表性或试块数量不足",{"key":27,"text":364,"correct":22},{"key":30,"text":405,"correct":22},"砂浆试块的试验结果，不能满足设计要求",{"key":34,"text":407,"correct":22},"发生工程事故，需要进一步分析事故原因",{"id":409,"libraryId":5,"type":15,"typeLabel":16,"stem":410,"options":411,"answer":81,"analysis":37},1271981,"钢结构工程分部合格质量标准是（ ）。",[412,414,416,418,420],{"key":20,"text":413,"correct":22},"分项合格",{"key":24,"text":415,"correct":22},"质量控制资料完整",{"key":27,"text":417,"correct":22},"检验和检测结果合格",{"key":30,"text":419,"correct":22},"观感质量合格",{"key":34,"text":421,"correct":32},"检验批中的主控项目合格",{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":424,"options":425,"answer":36,"analysis":37},1271982,"某多层钢结构厂房，总建筑面积约21000㎡，主体结构为三层钢结构，结构安全等级为二级。檐口总高度为19m，框架钢柱为焊接箱型柱，钢梁为焊接H型钢梁，楼面为压型钢板与混凝土叠台楼板，外墙面为压型彩板。主钢构件材质为Q345，檩条采用Q235型薄壁型钢。主要构件焊接质量等级为一级，本工程施工范围包括钢结构系统的制作与现场安装施工。 下列选项中，属于该钢结构安装工程施工质量控制点的有（ ）。",[426,428,430,432,434],{"key":20,"text":427,"correct":22},"钢结构吊装",{"key":24,"text":429,"correct":22},"钢构件连接与固定",{"key":27,"text":431,"correct":22},"钢结构的整体垂直度",{"key":30,"text":433,"correct":32},"焊接材料外观质量",{"key":34,"text":435,"correct":32},"焊缝外观质量",{"id":437,"libraryId":5,"type":15,"typeLabel":16,"stem":438,"options":439,"answer":206,"analysis":37},1271983,"连接用紧固标准件（ ）出厂时应分别随箱带有扭矩系数和紧固轴力（预拉力）的检验报告。",[440,442,444,446,448],{"key":20,"text":441,"correct":22},"高强度大六角头螺栓连接副",{"key":24,"text":443,"correct":22},"扭剪型高强度螺栓连接副",{"key":27,"text":445,"correct":32},"钢网架用高强度螺栓",{"key":30,"text":447,"correct":32},"锚栓（机械型和化学试剂型）",{"key":34,"text":449,"correct":32},"铆钉",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":36,"analysis":37},1271984,"高强度螺栓连接副是指（ ）的总称。",[454,456,458,460,462],{"key":20,"text":455,"correct":22},"高强度螺栓",{"key":24,"text":457,"correct":22},"螺母",{"key":27,"text":459,"correct":22},"垫圈",{"key":30,"text":461,"correct":32},"锚件",{"key":34,"text":463,"correct":32},"连接件",{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":302,"analysis":37},1271985,"钢材、钢铸件的（ ）等应符合现行国家产品标准和设计要求。",[468,470,472,474,476],{"key":20,"text":469,"correct":22},"品种",{"key":24,"text":471,"correct":22},"规格",{"key":27,"text":473,"correct":32},"数量",{"key":30,"text":475,"correct":22},"性能",{"key":34,"text":477,"correct":32},"级别",{"id":479,"libraryId":5,"type":15,"typeLabel":16,"stem":480,"options":481,"answer":36,"analysis":37},1271986,"焊接材料的质量应符合现行国家产品标准和设计要求，应检查（ ）。",[482,484,486,488,490],{"key":20,"text":483,"correct":22},"质量合格证明文件",{"key":24,"text":485,"correct":22},"中文标志",{"key":27,"text":487,"correct":22},"检验报告",{"key":30,"text":489,"correct":32},"进货清单",{"key":34,"text":491,"correct":32},"进场抽样检测报告",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":36,"analysis":37},1271987,"正常情况下钢结构原材料进场时，当（ ）符合要求时，方可验收。",[496,497,498,499,501],{"key":20,"text":483,"correct":22},{"key":24,"text":485,"correct":22},{"key":27,"text":487,"correct":22},{"key":30,"text":500,"correct":32},"复验报告",{"key":34,"text":502,"correct":32},"生产许可证",{"id":504,"libraryId":5,"type":15,"typeLabel":16,"stem":505,"options":506,"answer":96,"analysis":37},1271988,"压型金属板安装质量主控项目要求是（ ）。",[507,509,511,513,515],{"key":20,"text":508,"correct":32},"平整、顺直",{"key":24,"text":510,"correct":22},"固定可靠、牢固",{"key":27,"text":512,"correct":22},"防腐涂料涂刷完好",{"key":30,"text":514,"correct":22},"密封材料数设完好",{"key":34,"text":516,"correct":22},"连接件数量、间距符合设计要求",{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":111,"analysis":37},1271989,"钢结构工程应按下列规定进行施工质量控制：（ ）。",[521,523,525,527,529],{"key":20,"text":522,"correct":32},"所有原材料都应进行现场抽样检测",{"key":24,"text":524,"correct":22},"采用的原材料及成品应进行进场验收。凡涉及安全、功能的原材料及成品应按本规范规定进行复验，并应经监理工程师（建设单位技术负责人）见证取样、送样",{"key":27,"text":526,"correct":22},"各工序应按施工技术标准进行质量控制，每道工序完成后，应进行检查",{"key":30,"text":528,"correct":22},"相关各专业工种之间，应进行交接检验，并经监理工程师（建设单位技术负责人）",{"key":34,"text":530,"correct":32},"施工完成后应进行实体检测",{"id":532,"libraryId":5,"type":15,"typeLabel":16,"stem":533,"options":534,"answer":81,"analysis":37},1271990,"在焊条、焊丝、焊剂、电渣焊熔嘴等焊接材料与母材的匹配应符合设计要求及国家现行行业标准《建筑钢结构焊接技术规程》JGJ81的规定。（ ）等在使用前，应按其产品说明书及焊接工艺文件的规定进行烘焙和存放。",[535,537,539,541,543],{"key":20,"text":536,"correct":22},"焊条",{"key":24,"text":538,"correct":22},"焊剂",{"key":27,"text":540,"correct":22},"药芯焊丝",{"key":30,"text":542,"correct":22},"熔嘴",{"key":34,"text":544,"correct":32},"焊药",{"id":546,"libraryId":5,"type":15,"typeLabel":16,"stem":547,"options":548,"answer":81,"analysis":37},1271991,"钢结构防腐涂料涂装前表面除锈应符合设计要求和国家现行有关标准的规定。处理后的钢材表面不应有（ ）。",[549,551,553,555,557],{"key":20,"text":550,"correct":22},"焊渣",{"key":24,"text":552,"correct":22},"焊疤",{"key":27,"text":554,"correct":22},"灰尘",{"key":30,"text":556,"correct":22},"油污",{"key":34,"text":558,"correct":32},"磨痕",{"id":560,"libraryId":5,"type":15,"typeLabel":16,"stem":561,"options":562,"answer":67,"analysis":37},1271992,"对属于下列情况之一的钢材，应进行抽样复验：（ ）。",[563,565,567,569,571],{"key":20,"text":564,"correct":22},"进口钢材",{"key":24,"text":566,"correct":22},"钢材混批",{"key":27,"text":568,"correct":22},"设计有复验要求的钢材",{"key":30,"text":570,"correct":22},"对质量有疑义的钢材",{"key":34,"text":572,"correct":22},"板厚大于或等于40mm，且设计有Z向性能要求的厚板",{"id":574,"libraryId":5,"type":15,"typeLabel":16,"stem":575,"options":576,"answer":302,"analysis":37},1271993,"钢结构分项工程检验批合格质量标准是（ ）。",[577,579,581,582,583],{"key":20,"text":578,"correct":22},"主控项目质量合格",{"key":24,"text":580,"correct":22},"一般项目的检验结果应有80%及以上检查点（值）合格，偏差值不超过允许偏差值的1.2倍",{"key":27,"text":419,"correct":32},{"key":30,"text":415,"correct":22},{"key":34,"text":584,"correct":32},"一般项目的检查点全部合格",{"id":586,"libraryId":5,"type":15,"typeLabel":16,"stem":587,"options":588,"answer":126,"analysis":37},1271994,"木结构分项工程的检验批应按（ ）分别划分。",[589,591,593,595,597],{"key":20,"text":590,"correct":22},"材料",{"key":24,"text":592,"correct":32},"不同施工阶段",{"key":27,"text":594,"correct":22},"木产品结构、配件的物理力学性能质量控制",{"key":30,"text":596,"correct":22},"结构件制作安装质量控制",{"key":34,"text":598,"correct":32},"不同的楼层",{"id":600,"libraryId":5,"type":15,"typeLabel":16,"stem":601,"options":602,"answer":613,"analysis":37},1271995,"木结构用的防腐剂能毒杀（ ）对其他侵害木材生物的化学药剂。",[603,605,607,609,611],{"key":20,"text":604,"correct":32},"潮气",{"key":24,"text":606,"correct":32},"湿气",{"key":27,"text":608,"correct":22},"木腐菌",{"key":30,"text":610,"correct":22},"昆虫",{"key":34,"text":612,"correct":22},"凿船虫","CDE",{"id":615,"libraryId":5,"type":15,"typeLabel":16,"stem":616,"options":617,"answer":628,"analysis":37},1271996,"木结构子分部工程由（ ）两分项工程组成，并应在分项工程皆验收合格后，再进行子分部工程的验收。",[618,620,622,624,626],{"key":20,"text":619,"correct":22},"方木和原木结构",{"key":24,"text":621,"correct":32},"方木结构制作安装",{"key":27,"text":623,"correct":32},"胶合木结构",{"key":30,"text":625,"correct":32},"轻型木结构",{"key":34,"text":627,"correct":22},"木结构防护","AE",{"id":630,"libraryId":5,"type":15,"typeLabel":16,"stem":631,"options":632,"answer":81,"analysis":37},1271997,"木结构防护是为保证木结构在规定的设计使用年限内安全、可靠地满足使用功能要求，采取（ ）等措施予以保护。",[633,635,637,639,641],{"key":20,"text":634,"correct":22},"防腐",{"key":24,"text":636,"correct":22},"防虫蛀",{"key":27,"text":638,"correct":22},"防火",{"key":30,"text":640,"correct":22},"防潮通风",{"key":34,"text":642,"correct":32},"防受力",{"id":644,"libraryId":5,"type":15,"typeLabel":16,"stem":645,"options":646,"answer":111,"analysis":37},1271998,"钢木屋架下弦所用圆钢，除应作（ ）检验外，尚应作冷弯检验，并应满足设计文件规定的圆钢材质标准。",[647,648,650,651,653],{"key":20,"text":205,"correct":32},{"key":24,"text":649,"correct":22},"抗拉屈服强度",{"key":27,"text":134,"correct":22},{"key":30,"text":652,"correct":22},"延伸率",{"key":34,"text":654,"correct":32},"铁含量",{"id":656,"libraryId":5,"type":15,"typeLabel":16,"stem":657,"options":658,"answer":206,"analysis":37},1271999,"木结构工程各专业工种之间应进行交接检验，未经（ ）检查认可，不得进行下道工序施工。",[659,661,663,665,667],{"key":20,"text":660,"correct":22},"监理工程师",{"key":24,"text":662,"correct":22},"建设单位技术负责人",{"key":27,"text":664,"correct":32},"施工单位质检员",{"key":30,"text":666,"correct":32},"监督工程师",{"key":34,"text":668,"correct":32},"检测工程师",{"id":670,"libraryId":5,"type":15,"typeLabel":16,"stem":671,"options":672,"answer":111,"analysis":37},1272000,"除设计文件另有规定外，木结构工程应按下列规定验收其外观质量：（ ）。",[673,675,677,679,681],{"key":20,"text":674,"correct":32},"特级，结构构件外露，外观要求特高而需油漆，构件表面不允许有修补，木材表面应用砂纸打磨",{"key":24,"text":676,"correct":22},"A级，结构构件外露，外观要求很高而需油漆，构件表面洞孔需用木材修补，木材表面应用砂纸打磨",{"key":27,"text":678,"correct":22},"B级，结构构件外露，外表要求用机具刨光油漆，表面允许有偶尔的漏刨、细小的缺陷和空隙，但不允许有松软节的孔洞",{"key":30,"text":680,"correct":22},"C级，结构构件不外露，构件表面无需加工刨光",{"key":34,"text":682,"correct":32},"D级，结构构件不外露，构件表面无需加工",{"id":684,"libraryId":5,"type":15,"typeLabel":16,"stem":685,"options":686,"answer":697,"analysis":37},1272001,"当木结构施工需要采用国家现行有关标准尚未列人的新技术（新材料、新结构、新工艺）时，建设单位应征得当地建筑工程质量行政主管部门同意，并应组织专家组，会同（ ）单位进行论证，同时应确定施工质量验收方法和检验标准，并应依此作为相关木结构工程施工的主控项目。",[687,689,691,693,695],{"key":20,"text":688,"correct":22},"设计",{"key":24,"text":690,"correct":22},"监理",{"key":27,"text":692,"correct":32},"检测",{"key":30,"text":694,"correct":32},"审图",{"key":34,"text":696,"correct":22},"施工","ABE",{"id":699,"libraryId":5,"type":15,"typeLabel":16,"stem":700,"options":701,"answer":712,"analysis":37},1272002,"木结构工程中，检验批及木结构分项工程质量合格，应符合下列规定：（ ）。",[702,704,706,708,710],{"key":20,"text":703,"correct":22},"检验批主控项目检验结果应全部合格",{"key":24,"text":705,"correct":32},"检验批主控项目检验结果应90％以上合格",{"key":27,"text":707,"correct":22},"检验批一般项目检验结果应有80％以上的检查点合格，且最大偏差不应超过允许偏差的1.2倍",{"key":30,"text":709,"correct":32},"检验批一般项目检验结果应有80％以上的检查点合格，且最大偏差不应超过允许",{"key":34,"text":711,"correct":22},"木结构分项工程所含检验批检验结果均应合格，且应有各检验批质量验收的完整记录","ACE",[714,718,721,724,727,730],{"id":715,"name":716,"category":7,"favorite":717},1,"领导干部任职前廉政法规知识测试题",92,{"id":719,"name":720,"category":7,"favorite":715},595,"建筑结构与设备",{"id":722,"name":723,"category":7,"favorite":715},715,"招标采购专业知识与法律法规",{"id":725,"name":726,"category":7,"favorite":715},848,"市政方向-通用基础",{"id":728,"name":729,"category":7,"favorite":8},534,"BIM工程师",{"id":731,"name":729,"category":7,"favorite":8},535]