[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-858-10":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":515},{"id":5,"name":6,"category":7,"favorite":8},858,"(土建质量)专业管理实务 岗位知识","建筑工程",0,10,50,1473,[13,34,46,58,67,79,90,102,114,126,138,150,162,174,186,198,210,222,234,246,258,267,279,291,303,312,324,334,340,346,352,358,364,370,376,382,388,394,400,406,417,427,439,451,459,465,477,483,491,503],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},1271147,1,"单选题","原木或方木结构含水率应不大于（ ）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","15%",false,{"key":24,"text":25,"correct":22},"B","18%",{"key":27,"text":28,"correct":22},"C","20％",{"key":30,"text":31,"correct":32},"D","25％",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":27,"analysis":33},1271148,"木结构工程每批次进场目测分等规格材应由有资质的专业分等人员做目测等级见证检验或做抗弯强度见证检验；每批次进场机械分等规格材应作（ ）见证检验，并应符合《木结构工程施工质量验收规范》附录G的规定。",[38,40,42,44],{"key":20,"text":39,"correct":22},"抗压强度",{"key":24,"text":41,"correct":22},"目测",{"key":27,"text":43,"correct":32},"抗弯强度",{"key":30,"text":45,"correct":22},"抗拉强度",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":30,"analysis":33},1271149,"板材髓心在承重木结构中不允许使用在（ ）构件。",[50,52,54,56],{"key":20,"text":51,"correct":22},"受弯",{"key":24,"text":53,"correct":22},"受压",{"key":27,"text":55,"correct":22},"压弯",{"key":30,"text":57,"correct":32},"受拉或拉弯",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},1271150,"处于通风条件不畅环境下的木构件的木材，不应大于（ ）。",[62,63,64,65],{"key":20,"text":31,"correct":22},{"key":24,"text":28,"correct":32},{"key":27,"text":21,"correct":22},{"key":30,"text":66,"correct":22},"12%",{"id":68,"libraryId":5,"type":15,"typeLabel":16,"stem":69,"options":70,"answer":24,"analysis":33},1271151,"凡木构件外部需用防火石膏板等包覆时，包覆材料的防火性能应有（ ），厚度应符合设计文件的规定。",[71,73,75,77],{"key":20,"text":72,"correct":22},"型式检验报告",{"key":24,"text":74,"correct":32},"合格证书",{"key":27,"text":76,"correct":22},"现场抽样检测报告",{"key":30,"text":78,"correct":22},"出厂燃烧性能检测报告",{"id":80,"libraryId":5,"type":15,"typeLabel":16,"stem":81,"options":82,"answer":30,"analysis":33},1271152,"木结构中椽条是屋盖体系中支承屋面板的（ ）。",[83,84,86,88],{"key":20,"text":53,"correct":22},{"key":24,"text":85,"correct":22},"受拉",{"key":27,"text":87,"correct":22},"受剪",{"key":30,"text":89,"correct":32},"受弯构件",{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":30,"analysis":33},1271153,"轻型木结构的保温措施和隔气层的设置等，应符合（ ）的规定。",[94,96,98,100],{"key":20,"text":95,"correct":22},"建设单位",{"key":24,"text":97,"correct":22},"监理单位",{"key":27,"text":99,"correct":22},"工程质量监督机构",{"key":30,"text":101,"correct":32},"设计文件",{"id":103,"libraryId":5,"type":15,"typeLabel":16,"stem":104,"options":105,"answer":24,"analysis":33},1271154,"进场工字形木搁栅和结构复合木材受弯构件，应作（ ）的结构性能检验，在检验荷载作用下，构件不应发生开裂等损伤现象，最大挠度不应大于木结构验收规范的规定，跨中挠度的平均值不应大于理论计算值的1.13倍。",[106,108,110,112],{"key":20,"text":107,"correct":22},"自重作用下",{"key":24,"text":109,"correct":32},"荷载效应标准组合作用下",{"key":27,"text":111,"correct":22},"活荷载",{"key":30,"text":113,"correct":22},"标准荷载",{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":116,"options":117,"answer":30,"analysis":33},1271155,"木结构中外露钢构件及未作镀锌处理的金属连接件，应按设计文件的规定采取（ ）措施。",[118,120,122,124],{"key":20,"text":119,"correct":22},"防火",{"key":24,"text":121,"correct":22},"防虫",{"key":27,"text":123,"correct":22},"防腐",{"key":30,"text":125,"correct":32},"防锈蚀",{"id":127,"libraryId":5,"type":15,"typeLabel":16,"stem":128,"options":129,"answer":27,"analysis":33},1271156,"木桁架、梁、柱安装中的结构中心线允许偏差为（ ）mm。",[130,132,134,136],{"key":20,"text":131,"correct":22},"±10",{"key":24,"text":133,"correct":22},"±15",{"key":27,"text":135,"correct":32},"±20",{"key":30,"text":137,"correct":22},"±5",{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":24,"analysis":33},1271157,"架空隔热制品距山墙或女儿墙不得小于（ ）mm。",[142,144,146,148],{"key":20,"text":143,"correct":22},"200",{"key":24,"text":145,"correct":32},"250",{"key":27,"text":147,"correct":22},"300",{"key":30,"text":149,"correct":22},"400",{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":27,"analysis":33},1271158,"某公司办公楼工程，总建筑面积28811㎡，框架结构，地下1层，地上5层，局部6层，抗震等级为1级。地上标准层高度4.2m,非标准层高度6.3m。建筑总高22.2m。工程开工时间2001年12月15日，竣工时间2003年11月15日。工程屋面采用卷材防水，防水保护层采用水泥预制砖，屋面砖和防水卷材之间通过水泥砂浆粘接。情形1：在混凝土施工时，为保证其保护层厚度，项目部采用碎大理石作为垫块。情形2：该楼开间跨度为6m,混凝土浇筑完后待强度达到100％方才拆除模板，但仍然发现现浇梁中部出现挠度过大的情况。情形3：在连续潮湿高温的天气下，防水卷材和屋面砖发生了起鼓和变形。 模板和支撑的选用必须经过计算，下列哪项不需要进行计算（ ）。",[154,156,158,160],{"key":20,"text":155,"correct":22},"刚度",{"key":24,"text":157,"correct":22},"强度",{"key":27,"text":159,"correct":32},"硬度",{"key":30,"text":161,"correct":22},"稳定性",{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":164,"options":165,"answer":20,"analysis":33},1271159,"隔汽层应设置在（ ）与保温层之间隔汽层应选用气密性、水密性好的材料。",[166,168,170,172],{"key":20,"text":167,"correct":32},"结构层",{"key":24,"text":169,"correct":22},"构造层",{"key":27,"text":171,"correct":22},"防水层",{"key":30,"text":173,"correct":22},"主体基层",{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":176,"options":177,"answer":20,"analysis":33},1271161,"架空隔热相邻两块制品的高低差不得大于（ ）mm。",[178,180,182,184],{"key":20,"text":179,"correct":32},"3",{"key":24,"text":181,"correct":22},"5",{"key":27,"text":183,"correct":22},"6",{"key":30,"text":185,"correct":22},"8",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":30,"analysis":33},1271162,"防水层及附加层伸人水落口杯内不应小于（ ）mm，并应粘结牢固。",[190,192,194,196],{"key":20,"text":191,"correct":22},"15",{"key":24,"text":193,"correct":22},"20",{"key":27,"text":195,"correct":22},"25",{"key":30,"text":197,"correct":32},"50",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":30,"analysis":33},1271163,"屋面工程所用的防水、保温材料应有（ ），材料的品种、规格、性能等必须符合国家现行产品标准和设计要求。产品质量应由经过省级以上建设行政主管部门对其资质认可和质量技术监督部门对其计量认证的质量检测单位进行检测。",[202,204,206,208],{"key":20,"text":203,"correct":22},"产品合格证书",{"key":24,"text":205,"correct":22},"性能检测报告",{"key":27,"text":207,"correct":22},"生产许可证",{"key":30,"text":209,"correct":32},"产品合格证书和性能检测报告",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":24,"analysis":33},1271164,"屋面找坡应满足设计排水坡要求，结构找坡不应小于（ ），材料找坡宜为2％檐沟、天沟纵向找坡不应小于1％，沟底水落差不得超过200mm。",[214,216,218,220],{"key":20,"text":215,"correct":22},"2％",{"key":24,"text":217,"correct":32},"3％",{"key":27,"text":219,"correct":22},"4％",{"key":30,"text":221,"correct":22},"5％",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":24,"analysis":33},1271165,"屋面工程质量验收规范规定防水混凝土表面的裂缝宽度不应大于（ ）mm，并不得贯通。",[226,228,230,232],{"key":20,"text":227,"correct":22},"0.1",{"key":24,"text":229,"correct":32},"0.2",{"key":27,"text":231,"correct":22},"0.5",{"key":30,"text":233,"correct":22},"1",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":30,"analysis":33},1271166,"瓦片必须铺置牢固，在大风及地震设防地区或屋面坡度大于（ ）时，应按设计要求采取固定加强措施。",[238,240,242,244],{"key":20,"text":239,"correct":22},"30%",{"key":24,"text":241,"correct":22},"40%",{"key":27,"text":243,"correct":22},"50%",{"key":30,"text":245,"correct":32},"100%",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":24,"analysis":33},1271167,"泡沫混凝土的干密度、抗压强度、吸水率试件应采用符合《混凝土试模》JG237规定的规格为（ ）的立方体混土试模，应在现场浇注试模，24h后脱模，并标准养护28d。",[250,252,254,256],{"key":20,"text":251,"correct":22},"50m×50mm×50mm",{"key":24,"text":253,"correct":32},"100mm×100mm×100mm",{"key":27,"text":255,"correct":22},"150mm×150mm×150m",{"key":30,"text":257,"correct":22},"200mm×200mm×200mm",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":27,"analysis":33},1271168,"找平层分格缝纵横间距不宜大于（ ）m，分格缝的宽度宜为5~20mm。",[262,264,265,266],{"key":20,"text":263,"correct":22},"4",{"key":24,"text":181,"correct":22},{"key":27,"text":183,"correct":32},{"key":30,"text":185,"correct":22},{"id":268,"libraryId":5,"type":15,"typeLabel":16,"stem":269,"options":270,"answer":27,"analysis":33},1271169,"沥青瓦铺装时，脊瓦在两坡面瓦上的搭盖宽度，每边不应小于（ ）mm。",[271,273,275,277],{"key":20,"text":272,"correct":22},"100",{"key":24,"text":274,"correct":22},"120",{"key":27,"text":276,"correct":32},"150",{"key":30,"text":278,"correct":22},"180",{"id":280,"libraryId":5,"type":15,"typeLabel":16,"stem":281,"options":282,"answer":30,"analysis":33},1271170,"下列不属于强制性标准监督检查的方式的是（ ）。",[283,285,287,289],{"key":20,"text":284,"correct":22},"施工图设计文件审查单位应当对工程建设勘察、设计阶段执行强制性标准的情况实施监督",{"key":24,"text":286,"correct":22},"建设项目规划审查机构应当对工程建设规划阶段执行强制性标准的情况实施监督",{"key":27,"text":288,"correct":22},"工程质量监督机构应当对工程建设施工、监理、验收等阶段执行强制性标准的情况实施监督",{"key":30,"text":290,"correct":32},"质量检查员应当对整个施工过程进行质量监督",{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":24,"analysis":33},1271171,"能作蓄水检验的屋面，其蓄水检验时间不应小于（ ）。",[295,297,299,301],{"key":20,"text":296,"correct":22},"12",{"key":24,"text":298,"correct":32},"24",{"key":27,"text":300,"correct":22},"36",{"key":30,"text":302,"correct":22},"48",{"id":304,"libraryId":5,"type":15,"typeLabel":16,"stem":305,"options":306,"answer":24,"analysis":33},1271172,"检查屋面有无渗漏、积水和排水系统是否畅通，应在雨后或持续淋水（ ）h后进行，并应填写淋水试验记录。具备蓄水条件的檐沟、天沟应进行蓄水试验，蓄水时间不得少于24h，并应填写蓄水试验记录。",[307,308,310,311],{"key":20,"text":233,"correct":22},{"key":24,"text":309,"correct":32},"2",{"key":27,"text":183,"correct":22},{"key":30,"text":296,"correct":22},{"id":313,"libraryId":5,"type":15,"typeLabel":16,"stem":314,"options":315,"answer":30,"analysis":33},1271173,"某公司办公楼工程，总建筑面积28811㎡，框架结构，地下1层，地上5层，局部6层，抗震等级为1级。地上标准层高度4.2m,非标准层高度6.3m。建筑总高22.2m。工程开工时间2001年12月15日，竣工时间2003年11月15日。工程屋面采用卷材防水，防水保护层采用水泥预制砖，屋面砖和防水卷材之间通过水泥砂浆粘接。情形1：在混凝土施工时，为保证其保护层厚度，项目部采用碎大理石作为垫块。情形2：该楼开间跨度为6m,混凝土浇筑完后待强度达到100％方才拆除模板，但仍然发现现浇梁中部出现挠度过大的情况。情形3：在连续潮湿高温的天气下，防水卷材和屋面砖发生了起鼓和变形。 根据情形2，为避免出现混凝土浇筑过程中发生模板下垂过大的情况，应对模板进行起拱处理，请问一般当梁、板跨度超过（ ）时需要起拱。",[316,318,320,322],{"key":20,"text":317,"correct":22},"1m",{"key":24,"text":319,"correct":22},"2m",{"key":27,"text":321,"correct":22},"3m",{"key":30,"text":323,"correct":32},"4m",{"id":325,"libraryId":5,"type":326,"typeLabel":327,"stem":328,"options":329,"answer":331,"analysis":33},1271174,3,"判断题","细石混凝土不得使用火山灰质水泥，当采用矿渣硅酸盐水泥时，应采用减少泌水性的措施。（ ）",[330,332],{"key":20,"text":331,"correct":32},"正确",{"key":24,"text":333,"correct":22},"错误",{"id":335,"libraryId":5,"type":326,"typeLabel":327,"stem":336,"options":337,"answer":331,"analysis":33},1271175,"刚性防水屋面不适用设有松散材料保温层的屋面以及受较大振动或冲击的和坡度大于15％的建筑屋面。（ ）",[338,339],{"key":20,"text":331,"correct":32},{"key":24,"text":333,"correct":22},{"id":341,"libraryId":5,"type":326,"typeLabel":327,"stem":342,"options":343,"answer":331,"analysis":33},1271176,"涂膜应根据防水涂料的品种分遍涂布，不得一次涂成。应待先涂的涂层干燥成膜后，方可涂后一遍涂料。（ ）",[344,345],{"key":20,"text":331,"correct":32},{"key":24,"text":333,"correct":22},{"id":347,"libraryId":5,"type":326,"typeLabel":327,"stem":348,"options":349,"answer":333,"analysis":33},1271177,"刚性防水屋面分仓缝处混凝土应断开，但钢筋可以不断开。（ ）",[350,351],{"key":20,"text":331,"correct":22},{"key":24,"text":333,"correct":32},{"id":353,"libraryId":5,"type":326,"typeLabel":327,"stem":354,"options":355,"answer":333,"analysis":33},1271178,"架空隔热制品支座底面的卷材、涂膜防水层上，一般可以不另采取加强措施。（ ）",[356,357],{"key":20,"text":331,"correct":22},{"key":24,"text":333,"correct":32},{"id":359,"libraryId":5,"type":326,"typeLabel":327,"stem":360,"options":361,"answer":331,"analysis":33},1271179,"基层与突出屋面结构的交接处和基层的转角处，找平层均应做成圆弧形。但不同材质的卷材，其圆弧直径要求是不同的。（ ）",[362,363],{"key":20,"text":331,"correct":32},{"key":24,"text":333,"correct":22},{"id":365,"libraryId":5,"type":326,"typeLabel":327,"stem":366,"options":367,"answer":331,"analysis":33},1271180,"涂膜防水层应直接涂刷至女儿墙的压顶下，收头处理应用防水涂料多遍涂刷封存严密，压顶应做防水处理。（ ）",[368,369],{"key":20,"text":331,"correct":32},{"key":24,"text":333,"correct":22},{"id":371,"libraryId":5,"type":326,"typeLabel":327,"stem":372,"options":373,"answer":333,"analysis":33},1271181,"卷材防水当坡度大于30%时，应采取固定措施，固定点应密封严密。（ ）",[374,375],{"key":20,"text":331,"correct":22},{"key":24,"text":333,"correct":32},{"id":377,"libraryId":5,"type":326,"typeLabel":327,"stem":378,"options":379,"answer":331,"analysis":33},1271182,"不得在松散材料保温层上做细石混凝土防水层。（ ）",[380,381],{"key":20,"text":331,"correct":32},{"key":24,"text":333,"correct":22},{"id":383,"libraryId":5,"type":326,"typeLabel":327,"stem":384,"options":385,"answer":333,"analysis":33},1271183,"细石混凝土防水屋面有抗渗性能，因此混凝土不仅要做抗压强度试验，而且还要做抗渗试验。（ ）",[386,387],{"key":20,"text":331,"correct":22},{"key":24,"text":333,"correct":32},{"id":389,"libraryId":5,"type":326,"typeLabel":327,"stem":390,"options":391,"answer":331,"analysis":33},1271184,"对一般的建筑物，其防水层合理年限为10年，设防要求为一道设防对重要的建筑和高层建筑，其防水层合理使用年限为15年，设防要求为二道设防。（ ）",[392,393],{"key":20,"text":331,"correct":32},{"key":24,"text":333,"correct":22},{"id":395,"libraryId":5,"type":326,"typeLabel":327,"stem":396,"options":397,"answer":331,"analysis":33},1271185,"密封材料是不定型膏状体。（ ）",[398,399],{"key":20,"text":331,"correct":32},{"key":24,"text":333,"correct":22},{"id":401,"libraryId":5,"type":326,"typeLabel":327,"stem":402,"options":403,"answer":331,"analysis":33},1271186,"屋面混凝土墙上应事先预埋留好凹槽，以利于卷材收头。（ ）",[404,405],{"key":20,"text":331,"correct":32},{"key":24,"text":333,"correct":22},{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":27,"analysis":33},1271187,"突出屋面结构的侧面瓦伸入泛水宽度不应小于（ ）mm。",[410,412,414,415],{"key":20,"text":411,"correct":22},"80",{"key":24,"text":413,"correct":22},"70",{"key":27,"text":197,"correct":32},{"key":30,"text":416,"correct":22},"30",{"id":418,"libraryId":5,"type":15,"typeLabel":16,"stem":419,"options":420,"answer":27,"analysis":33},1271188,"隔汽层采用卷材时宜空铺，卷材搭接缝应满粘，其搭接宽度不应小于（ ）mm隔汽层采用涂料时，应涂刷均匀。",[421,423,425,426],{"key":20,"text":422,"correct":22},"40",{"key":24,"text":424,"correct":22},"60",{"key":27,"text":411,"correct":32},{"key":30,"text":272,"correct":22},{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":20,"analysis":33},1271189,"保温材料使用时的含水率，应（ ）。",[431,433,435,437],{"key":20,"text":432,"correct":32},"相当于该材料在当地自然风干状态下的平衡含水率",{"key":24,"text":434,"correct":22},"小于当地自然风干状态下的平衡含水率",{"key":27,"text":436,"correct":22},"大于当地自然风干状态下的平衡含水率",{"key":30,"text":438,"correct":22},"小于15％",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":20,"analysis":33},1271190,"屋面工程应根据建筑物的性质、重要程度、使用功能要求以及防水层合理使用年限，按不同等级进行设防，屋面防水等级共分（ ）个等级。",[443,445,447,449],{"key":20,"text":444,"correct":32},"二",{"key":24,"text":446,"correct":22},"三",{"key":27,"text":448,"correct":22},"四",{"key":30,"text":450,"correct":22},"五",{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":453,"options":454,"answer":27,"analysis":33},1271191,"胎体增强材料长边搭接宽度不应小于50mm，短边搭接宽度不应小于（ ）mm。",[455,456,457,458],{"key":20,"text":272,"correct":22},{"key":24,"text":274,"correct":22},{"key":27,"text":413,"correct":32},{"key":30,"text":197,"correct":22},{"id":460,"libraryId":5,"type":326,"typeLabel":327,"stem":461,"options":462,"answer":333,"analysis":33},1271192,"卷材防水屋面、涂膜防水屋面、刚性防水屋面及瓦屋面均属于屋面工程的各子分部工程，隔热屋面可在各子分部之中，不单独属于一个子分部。（ ）",[463,464],{"key":20,"text":331,"correct":22},{"key":24,"text":333,"correct":32},{"id":466,"libraryId":5,"type":15,"typeLabel":16,"stem":467,"options":468,"answer":20,"analysis":33},1271193,"屋面工程使用的材料应符合国家现行有关标准对（ ）限量的规定，不得对周围环境造成污染。",[469,471,473,475],{"key":20,"text":470,"correct":32},"材料有害物质",{"key":24,"text":472,"correct":22},"材料重量",{"key":27,"text":474,"correct":22},"单个材料体积",{"key":30,"text":476,"correct":22},"导热性能",{"id":478,"libraryId":5,"type":326,"typeLabel":327,"stem":479,"options":480,"answer":333,"analysis":33},1271194,"屋面的保温层和防水层严禁在雨大、雪天和五级及其以上时施工。施工时环境气温一般不做要求。（ ）",[481,482],{"key":20,"text":331,"correct":22},{"key":24,"text":333,"correct":32},{"id":484,"libraryId":5,"type":15,"typeLabel":16,"stem":485,"options":486,"answer":20,"analysis":33},1271195,"热熔法铺贴卷材时，厚度小于（ ）mm的高聚物改性沥青防水卷材，严禁采用热熔法施工。",[487,488,489,490],{"key":20,"text":179,"correct":32},{"key":24,"text":263,"correct":22},{"key":27,"text":181,"correct":22},{"key":30,"text":183,"correct":22},{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":30,"analysis":33},1271196,"现浇泡沫混凝土保温层的厚度应符合设计要求，其正负偏差应为5%，且不得大于5mm。检验方法为（ ）。",[495,497,499,501],{"key":20,"text":496,"correct":22},"钢针插人",{"key":24,"text":498,"correct":22},"尺量检查",{"key":27,"text":500,"correct":22},"钻芯测量",{"key":30,"text":502,"correct":32},"钢针插人和尺量检查",{"id":504,"libraryId":5,"type":15,"typeLabel":16,"stem":505,"options":506,"answer":20,"analysis":33},1271197,"屋面工程中找平层宜采用水泥砂浆或细石混凝土找平层的抹平工序应在（ ）完成，压光工序应在终凝前完成，终凝后应进行养护。",[507,509,511,513],{"key":20,"text":508,"correct":32},"初凝前",{"key":24,"text":510,"correct":22},"终凝前",{"key":27,"text":512,"correct":22},"初凝后",{"key":30,"text":514,"correct":22},"终凝后",[516,519,522,525,528,531],{"id":15,"name":517,"category":7,"favorite":518},"领导干部任职前廉政法规知识测试题",92,{"id":520,"name":521,"category":7,"favorite":15},595,"建筑结构与设备",{"id":523,"name":524,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":526,"name":527,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":529,"name":530,"category":7,"favorite":8},534,"BIM工程师",{"id":532,"name":530,"category":7,"favorite":8},535]