[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-858-1":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":585},{"id":5,"name":6,"category":7,"favorite":8},858,"(土建质量)专业管理实务 岗位知识","建筑工程",0,1,50,1473,[13,33,45,57,69,81,93,105,117,129,141,149,160,171,183,191,203,215,227,239,251,263,275,287,299,311,321,333,345,356,367,379,391,403,415,423,435,447,456,468,477,489,501,513,521,533,541,553,564,573],{"id":14,"libraryId":5,"type":9,"typeLabel":15,"stem":16,"options":17,"answer":26,"analysis":32},1270688,"单选题","下列不属于强制性标准监督检查的内容的是（ ）。",[18,22,25,29],{"key":19,"text":20,"correct":21},"A","有关工程技术人员是否熟悉、掌握强制性标准",false,{"key":23,"text":24,"correct":21},"B","工程项目采用的材料、设备是否符合强制性标准的规定",{"key":26,"text":27,"correct":28},"C","工程竣工验收是否符合强制性标准的规定",true,{"key":30,"text":31,"correct":21},"D","工程项目的规划、勘察、设计、施工、验收等是符合强制性标准的规定","",{"id":34,"libraryId":5,"type":9,"typeLabel":15,"stem":35,"options":36,"answer":26,"analysis":32},1270689,"当房间使用面积大于等于100，且小于500时，室内环境污染物浓度监测点数设置不少于（ ）个。",[37,39,41,43],{"key":19,"text":38,"correct":21},"1",{"key":23,"text":40,"correct":21},"2",{"key":26,"text":42,"correct":28},"3",{"key":30,"text":44,"correct":21},"4",{"id":46,"libraryId":5,"type":9,"typeLabel":15,"stem":47,"options":48,"answer":26,"analysis":32},1270690,"蒸压加气混凝土砌块、轻骨料混凝土小型空心砌块砌筑时，其产品龄期应超过（ ）。",[49,51,53,55],{"key":19,"text":50,"correct":21},"7天",{"key":23,"text":52,"correct":21},"14天",{"key":26,"text":54,"correct":28},"28天",{"key":30,"text":56,"correct":21},"42天",{"id":58,"libraryId":5,"type":9,"typeLabel":15,"stem":59,"options":60,"answer":30,"analysis":32},1270691,"将主要成分为（ ）的天然岩石，在适当温度下煅烧，排除分解出的二氧化碳后，所得的以氧化钙（CaO）为主要成分的产品即为石灰，又称生石灰。",[61,63,65,67],{"key":19,"text":62,"correct":21},"硫酸钙",{"key":23,"text":64,"correct":21},"氢氧化钙",{"key":26,"text":66,"correct":21},"碳酸钠",{"key":30,"text":68,"correct":28},"碳酸钙",{"id":70,"libraryId":5,"type":9,"typeLabel":15,"stem":71,"options":72,"answer":23,"analysis":32},1270692,"分项工程可由出一个或若干检验批组成，检验批可根据施工及质量控制和专业验收需要按（ ）等进行划分。",[73,75,77,79],{"key":19,"text":74,"correct":21},"材料种类",{"key":23,"text":76,"correct":28},"楼层、施工段、变形缝",{"key":26,"text":78,"correct":21},"施工特点",{"key":30,"text":80,"correct":21},"施工程序",{"id":82,"libraryId":5,"type":9,"typeLabel":15,"stem":83,"options":84,"answer":26,"analysis":32},1270693,"建筑地面工程施工质量的检验规定：基层（各构造层）和各类面层的分项工程的施工质量验收应按每一层次或每层施工段（或变形缝）作为检验批，高层建筑的标准层可按每（ ）层作为检验批。",[85,87,89,91],{"key":19,"text":86,"correct":21},"一",{"key":23,"text":88,"correct":21},"二",{"key":26,"text":90,"correct":28},"三",{"key":30,"text":92,"correct":21},"四",{"id":94,"libraryId":5,"type":9,"typeLabel":15,"stem":95,"options":96,"answer":23,"analysis":32},1270694,"《民用建筑设计通则》GB50352—2005中，住宅、托儿所、幼儿园、中小学及少年儿童专用活动场所的栏杆必须采用防止少年儿童攀登的构造，当采用垂直杆件做栏杆时，其杆件净距不应大于（ ）m。",[97,99,101,103],{"key":19,"text":98,"correct":21},"0.10",{"key":23,"text":100,"correct":28},"0.11",{"key":26,"text":102,"correct":21},"0.12",{"key":30,"text":104,"correct":21},"0.13",{"id":106,"libraryId":5,"type":9,"typeLabel":15,"stem":107,"options":108,"answer":26,"analysis":32},1270695,"《建筑桩基技术规范》JGJ94一2008中，压桩过程中当桩身垂直度偏差大于（ ）时，应找出原因并设法纠正。",[109,111,113,115],{"key":19,"text":110,"correct":21},"2％",{"key":23,"text":112,"correct":21},"3％",{"key":26,"text":114,"correct":28},"1％",{"key":30,"text":116,"correct":21},"4％",{"id":118,"libraryId":5,"type":9,"typeLabel":15,"stem":119,"options":120,"answer":19,"analysis":32},1270696,"《建筑防水工程技术规程》DBJ15—19—2006中，外墙找平层施工前，应对墙面进行检查，并按设计要求铺挂加强网。当设计无规定时，应在外墙面混凝土梁、板、柱与砌体之间铺挂加强网，每侧网宽不应小于（ ）mm。",[121,123,125,127],{"key":19,"text":122,"correct":28},"100－150",{"key":23,"text":124,"correct":21},"50－100",{"key":26,"text":126,"correct":21},"150－200",{"key":30,"text":128,"correct":21},"200－250",{"id":130,"libraryId":5,"type":9,"typeLabel":15,"stem":131,"options":132,"answer":23,"analysis":32},1270697,"《民用建筑设计通则》GB50352—2005中，阳台、外廊、室内回廊、内天井、上人屋面及室外楼梯等临空处应设置防护栏杆，临空高度在24m以下时，栏杆高度不应低于（ ）m，临空高度在24m及24m以上（包括中高层住宅）时，栏杆高度不应低于（ ）m。",[133,135,137,139],{"key":19,"text":134,"correct":21},"1.05、1.05",{"key":23,"text":136,"correct":28},"1.05、1.10",{"key":26,"text":138,"correct":21},"1.10、1.10",{"key":30,"text":140,"correct":21},"1.05、1.15",{"id":142,"libraryId":5,"type":9,"typeLabel":15,"stem":143,"options":144,"answer":23,"analysis":32},1270698,"填充墙砌至接近梁、板底时，应留一定空隙，待填充墙砌完并应至少间隔（ ）后，再将其补砌挤紧。",[145,146,147,148],{"key":19,"text":50,"correct":21},{"key":23,"text":52,"correct":28},{"key":26,"text":54,"correct":21},{"key":30,"text":56,"correct":21},{"id":150,"libraryId":5,"type":9,"typeLabel":15,"stem":151,"options":152,"answer":26,"analysis":32},1270699,"一般项目在验收时，绝大多数抽查的处（件），其质量指标都必须达到要求，其余20%虽可以超过一定的指标，也是有限的，通常不得超过规定值的50%，即最大偏差不得大于（ ）倍。",[153,155,157,159],{"key":19,"text":154,"correct":21},"1.2",{"key":23,"text":156,"correct":21},"1.1",{"key":26,"text":158,"correct":28},"1.5",{"key":30,"text":40,"correct":21},{"id":161,"libraryId":5,"type":9,"typeLabel":15,"stem":162,"options":163,"answer":23,"analysis":32},1270701,"《建筑抗震设计规范》（GB50011—2010）规定，有较高要求的抗震结构适用的钢筋牌号中已有带肋钢筋牌号后加（ ）的钢筋。",[164,165,167,169],{"key":19,"text":30,"correct":21},{"key":23,"text":166,"correct":28},"E",{"key":26,"text":168,"correct":21},"F",{"key":30,"text":170,"correct":21},"G",{"id":172,"libraryId":5,"type":9,"typeLabel":15,"stem":173,"options":174,"answer":23,"analysis":32},1270702,"分项工程检验批合格质量标准应符合下列规定:主控项目必须符合本规范合格质量标准的要求。一般项目其检验结果应有（ ）的检查点（值）符合规范合格质量标准的要求，且最大值不应超过其允许偏差值的1.2倍。",[175,177,179,181],{"key":19,"text":176,"correct":21},"70%及以上",{"key":23,"text":178,"correct":28},"80%及以上",{"key":26,"text":180,"correct":21},"85%及以上",{"key":30,"text":182,"correct":21},"90%及以上",{"id":184,"libraryId":5,"type":9,"typeLabel":15,"stem":185,"options":186,"answer":26,"analysis":32},1270703,"混凝土每次取样应至少制作一组标准养护试件。每组（ ）个试件应由同一盘或同一车的混凝土中取样制作。",[187,188,189,190],{"key":19,"text":38,"correct":21},{"key":23,"text":40,"correct":21},{"key":26,"text":42,"correct":28},{"key":30,"text":44,"correct":21},{"id":192,"libraryId":5,"type":9,"typeLabel":15,"stem":193,"options":194,"answer":19,"analysis":32},1270704,"《建筑地面工程施工质量验收规范》GB50209一2010中，室内楼（地）面面层与下一层应结合牢固，且应无空鼓和开裂。当出现空鼓时，空鼓面积不应大于（ ）㎝2，且每自然间或标准间不应多于（ ）处。",[195,197,199,201],{"key":19,"text":196,"correct":28},"400、2",{"key":23,"text":198,"correct":21},"400、1",{"key":26,"text":200,"correct":21},"300、2",{"key":30,"text":202,"correct":21},"300、1",{"id":204,"libraryId":5,"type":9,"typeLabel":15,"stem":205,"options":206,"answer":23,"analysis":32},1270705,"保温浆料应分层施工，每层厚度不宜大于（ ）。",[207,209,211,213],{"key":19,"text":208,"correct":21},"8mm",{"key":23,"text":210,"correct":28},"10mm",{"key":26,"text":212,"correct":21},"12mm",{"key":30,"text":214,"correct":21},"14mm",{"id":216,"libraryId":5,"type":9,"typeLabel":15,"stem":217,"options":218,"answer":23,"analysis":32},1270706,"民用建筑工程经验时，环境污染物浓度现场监测点应距内墙面不小于（ ）、距楼地面高度0.8~1.5m。",[219,221,223,225],{"key":19,"text":220,"correct":21},"0.3m",{"key":23,"text":222,"correct":28},"0.5m",{"key":26,"text":224,"correct":21},"1.0m",{"key":30,"text":226,"correct":21},"1.2m",{"id":228,"libraryId":5,"type":9,"typeLabel":15,"stem":229,"options":230,"answer":19,"analysis":32},1270707,"抹灰施工过程主要有①做灰饼、②基层处理洒水湿润、③阴阳角找方、④冲筋、⑤底、中层找平抹灰、⑥面层抹灰压光，正确顺序为（ ）。",[231,233,235,237],{"key":19,"text":232,"correct":28},"②→①→④→③→⑤→⑥",{"key":23,"text":234,"correct":21},"①→②→③→④→⑤→⑥",{"key":26,"text":236,"correct":21},"①→②→④→③→⑤→⑥",{"key":30,"text":238,"correct":21},"②→①→③→④→⑤→⑥",{"id":240,"libraryId":5,"type":9,"typeLabel":15,"stem":241,"options":242,"answer":19,"analysis":32},1270708,"砌体水平灰缝的砂浆饱满度不得小于（ ）。",[243,245,247,249],{"key":19,"text":244,"correct":28},"80%",{"key":23,"text":246,"correct":21},"90%",{"key":26,"text":248,"correct":21},"70%",{"key":30,"text":250,"correct":21},"100%",{"id":252,"libraryId":5,"type":9,"typeLabel":15,"stem":253,"options":254,"answer":23,"analysis":32},1270709,"为防止填充墙与梁、板接合处水平裂缝，墙砌至梁板底前就算留了一定空隙，且在停歇（ ）d后将留空处补砌挤紧。",[255,257,259,261],{"key":19,"text":256,"correct":21},"7",{"key":23,"text":258,"correct":28},"14",{"key":26,"text":260,"correct":21},"21",{"key":30,"text":262,"correct":21},"28",{"id":264,"libraryId":5,"type":9,"typeLabel":15,"stem":265,"options":266,"answer":19,"analysis":32},1270710,"经工程质量检测单位检测鉴定达不到设计要求，经设计单位验算可满足结构安全和使用功能的要求，应视为（ ）。",[267,269,271,273],{"key":19,"text":268,"correct":28},"符合规范规定质量合格的工程",{"key":23,"text":270,"correct":21},"不符合规范规定质量不合格，但可使用工程",{"key":26,"text":272,"correct":21},"质量不符合要求，但可协商验收的工程",{"key":30,"text":274,"correct":21},"质量不符合要求，不得验收",{"id":276,"libraryId":5,"type":9,"typeLabel":15,"stem":277,"options":278,"answer":30,"analysis":32},1270711,"下列施工质量控制措施中，不属于事前控制的是（ ）。",[279,281,283,285],{"key":19,"text":280,"correct":21},"落实质量责任",{"key":23,"text":282,"correct":21},"设置质量管理点",{"key":26,"text":284,"correct":21},"明确质量目标",{"key":30,"text":286,"correct":28},"施工质量检查验收",{"id":288,"libraryId":5,"type":9,"typeLabel":15,"stem":289,"options":290,"answer":23,"analysis":32},1270712,"屋面工程验收的文件和记录体现了施工全过程控制，必须做到真实、准确，不得有涂改和伪造，（ ）签字后方可有效。",[291,293,295,297],{"key":19,"text":292,"correct":21},"项目经理",{"key":23,"text":294,"correct":28},"各级技术负责人",{"key":26,"text":296,"correct":21},"总监理工程师",{"key":30,"text":298,"correct":21},"质量员",{"id":300,"libraryId":5,"type":9,"typeLabel":15,"stem":301,"options":302,"answer":30,"analysis":32},1270713,"单位工程的观感质量应由验收人员通过现场检查，并应（ ）确认。",[303,305,307,309],{"key":19,"text":304,"correct":21},"监理单位",{"key":23,"text":306,"correct":21},"施工单位",{"key":26,"text":308,"correct":21},"建设单位",{"key":30,"text":310,"correct":28},"共同",{"id":312,"libraryId":5,"type":9,"typeLabel":15,"stem":313,"options":314,"answer":19,"analysis":32},1270714,"屋面工程验收后，应填写分部工程质量验收记录，交建设单位和（ ）存档。",[315,316,317,319],{"key":19,"text":306,"correct":28},{"key":23,"text":304,"correct":21},{"key":26,"text":318,"correct":21},"设计单位",{"key":30,"text":320,"correct":21},"城建单位",{"id":322,"libraryId":5,"type":9,"typeLabel":15,"stem":323,"options":324,"answer":30,"analysis":32},1270715,"建筑地面工程属于（ ）分部工程。",[325,327,329,331],{"key":19,"text":326,"correct":21},"建筑装饰",{"key":23,"text":328,"correct":21},"建筑装修",{"key":26,"text":330,"correct":21},"地面与楼面",{"key":30,"text":332,"correct":28},"建筑装饰装修",{"id":334,"libraryId":5,"type":9,"typeLabel":15,"stem":335,"options":336,"answer":19,"analysis":32},1270716,"找平层施工完成后，应及时覆盖浇水养护，养护时间宜为（ ）。",[337,339,341,343],{"key":19,"text":338,"correct":28},"7~10d",{"key":23,"text":340,"correct":21},"10~14d",{"key":26,"text":342,"correct":21},"14~18d",{"key":30,"text":344,"correct":21},"24~28d",{"id":346,"libraryId":5,"type":9,"typeLabel":15,"stem":347,"options":348,"answer":19,"analysis":32},1270717,"〖背景资料〗某工程建筑面积5万余平方米，由塔楼及裙房组成，建筑高度为90m，箱形基础，地下3层，基础埋深为12m。该建设单位在裙房施工竣工后，具备使用功能，计划先投入使用，主体结构由A建筑公司施工，混凝土基础工程则分包给B专业基础公司组织施工，装饰装修工程分包给C装饰公司施工。混凝土强度等级为C30，经混凝土强度评定，混凝土强度等级达不到设计要求，后对实体强度进行检测，能够达到设计要求。 基础分部工程质量应由（ ）组织施工项目经理和有关勘察、设计单位项目负责人进行验收。",[349,350,352,354],{"key":19,"text":296,"correct":28},{"key":23,"text":351,"correct":21},"建筑工程质量监督部门",{"key":26,"text":353,"correct":21},"专业监理工程师",{"key":30,"text":355,"correct":21},"建设方",{"id":357,"libraryId":5,"type":9,"typeLabel":15,"stem":358,"options":359,"answer":23,"analysis":32},1270718,"回填土应由低处开始分层回填、夯实，采用蛙式打夯机夯实，每层厚度不宜大于（ ）mm。",[360,362,363,365],{"key":19,"text":361,"correct":21},"100－200",{"key":23,"text":128,"correct":28},{"key":26,"text":364,"correct":21},"250－350",{"key":30,"text":366,"correct":21},"350－450",{"id":368,"libraryId":5,"type":9,"typeLabel":15,"stem":369,"options":370,"answer":19,"analysis":32},1270719,"建筑施工企业在施工中偷工减料的，使用不合格的建筑材料、建筑构配件和设备的，或者有其他不按照工程设计图纸或者施工技术标准施工的行为的，（ ）。",[371,373,375,377],{"key":19,"text":372,"correct":28},"责令改正，处以罚款",{"key":23,"text":374,"correct":21},"责令停业整顿，降低资质等级",{"key":26,"text":376,"correct":21},"责令停业整顿，吊销资质证书",{"key":30,"text":378,"correct":21},"依法追究刑事责任",{"id":380,"libraryId":5,"type":9,"typeLabel":15,"stem":381,"options":382,"answer":23,"analysis":32},1270720,"砂浆强度等级是以边长为（ ）mm的立方体试件，在标准养护条件下，用标准试验方法测得28d龄期的抗压强度值（单位为MPa）确定。",[383,385,387,389],{"key":19,"text":384,"correct":21},"50",{"key":23,"text":386,"correct":28},"70.7",{"key":26,"text":388,"correct":21},"100",{"key":30,"text":390,"correct":21},"150",{"id":392,"libraryId":5,"type":9,"typeLabel":15,"stem":393,"options":394,"answer":30,"analysis":32},1270721,"下列不属于建筑地面工程子分部工程观感质量综合评价应检查的项目的是（ ）。",[395,397,399,401],{"key":19,"text":396,"correct":21},"变形缝的位置和宽度以及填缝质量应符合规定",{"key":23,"text":398,"correct":21},"室内建筑地面工程按各子分部工程经抽查分别做出评价",{"key":26,"text":400,"correct":21},"楼梯、踏步等工程项目经抽查分别做出评价",{"key":30,"text":402,"correct":28},"地面平整度的观感质量做出评价",{"id":404,"libraryId":5,"type":9,"typeLabel":15,"stem":405,"options":406,"answer":23,"analysis":32},1270722,"下列不属于注浆工程的质量要求的是（ ）。",[407,409,411,413],{"key":19,"text":408,"correct":21},"注浆孔的间距、深度及数量应符合设计要求",{"key":23,"text":410,"correct":28},"反滤层的砂、石粒径、含泥量和层次排列应符合设计要求",{"key":26,"text":412,"correct":21},"注浆效果应符合设计要求",{"key":30,"text":414,"correct":21},"地表沉降控制应符合设计要求",{"id":416,"libraryId":5,"type":9,"typeLabel":15,"stem":417,"options":418,"answer":23,"analysis":32},1270723,"保温砌块砌筑的墙体，应采用具有保温功能的砂浆砌筑。砌筑砂浆的强度等级应符合设计要求。砌体的水平灰缝饱满度不应低于（ ），竖直灰缝饱满度不应低于80%。",[419,420,421,422],{"key":19,"text":244,"correct":21},{"key":23,"text":246,"correct":28},{"key":26,"text":248,"correct":21},{"key":30,"text":250,"correct":21},{"id":424,"libraryId":5,"type":9,"typeLabel":15,"stem":425,"options":426,"answer":19,"analysis":32},1270724,"砌块按其空心率大小可分为空心砌块和实心砌块两种。空心率小于（ ）或无孔洞的砌块为实心砌块。",[427,429,431,433],{"key":19,"text":428,"correct":28},"25％",{"key":23,"text":430,"correct":21},"20％",{"key":26,"text":432,"correct":21},"15％",{"key":30,"text":434,"correct":21},"10％",{"id":436,"libraryId":5,"type":9,"typeLabel":15,"stem":437,"options":438,"answer":30,"analysis":32},1270725,"施工单位未对建筑材料、建筑构配件、设备和商品混凝土进行检验，或者未对涉及结构安全的试块、试件以及有关材料取样检测的，责令改正，处（ ）的罚款。",[439,441,443,445],{"key":19,"text":440,"correct":21},"5万元以上10以下",{"key":23,"text":442,"correct":21},"10万元以上12万元以下",{"key":26,"text":444,"correct":21},"10万元以上15万元以下",{"key":30,"text":446,"correct":28},"10万元以上20万元以下",{"id":448,"libraryId":5,"type":9,"typeLabel":15,"stem":449,"options":450,"answer":30,"analysis":32},1270726,"水泥按同一生产厂家、同一等级、同一品种、同一批号且连续进场的水泥，袋装不超过（ ）t为一批，散装不超过500t为一批，每批抽样不少于一次。",[451,452,453,454],{"key":19,"text":384,"correct":21},{"key":23,"text":388,"correct":21},{"key":26,"text":390,"correct":21},{"key":30,"text":455,"correct":28},"200",{"id":457,"libraryId":5,"type":9,"typeLabel":15,"stem":458,"options":459,"answer":26,"analysis":32},1270727,"建筑工程质量验收应划分为单位（子单位）工程、分部（子分部）工程、分项工程和（ ）。",[460,462,464,466],{"key":19,"text":461,"correct":21},"验收部位",{"key":23,"text":463,"correct":21},"工序",{"key":26,"text":465,"correct":28},"检验批",{"key":30,"text":467,"correct":21},"专业验收",{"id":469,"libraryId":5,"type":9,"typeLabel":15,"stem":470,"options":471,"answer":30,"analysis":32},1270728,"门窗工程属于（ ）分部工程。",[472,473,474,476],{"key":19,"text":326,"correct":21},{"key":23,"text":328,"correct":21},{"key":26,"text":475,"correct":21},"门窗",{"key":30,"text":332,"correct":28},{"id":478,"libraryId":5,"type":9,"typeLabel":15,"stem":479,"options":480,"answer":30,"analysis":32},1270729,"下列关于钢结构工程进行施工质量控制规定表述错误的是（ ）。",[481,483,485,487],{"key":19,"text":482,"correct":21},"采用的原材料及成品应进行进场验收",{"key":23,"text":484,"correct":21},"各工序应按施工技术标准进行质量控制，每道工序完成后，应进行检查",{"key":26,"text":486,"correct":21},"相关各专业工种之间，应进行交接检验，并经监理工程师（建设单位技术负责人）检查认可",{"key":30,"text":488,"correct":28},"凡涉及安全、功能的原材料及成品应按规范规定进行复检，并应经质检人员见证取样、送样",{"id":490,"libraryId":5,"type":9,"typeLabel":15,"stem":491,"options":492,"answer":23,"analysis":32},1270730,"〖背景资料〗某工程建筑面积5万余平方米，由塔楼及裙房组成，建筑高度为90m，箱形基础，地下3层，基础埋深为12m。该建设单位在裙房施工竣工后，具备使用功能，计划先投入使用，主体结构由A建筑公司施工，混凝土基础工程则分包给B专业基础公司组织施工，装饰装修工程分包给C装饰公司施工。混凝土强度等级为C30，经混凝土强度评定，混凝土强度等级达不到设计要求，后对实体强度进行检测，能够达到设计要求。 对于该工程施工过程中发现部分试块混凝土强度达不到设计要求，但对实际强度经检测论证，能够达到设计要求，该问题的处理方法为（ ）。",[493,495,497,499],{"key":19,"text":494,"correct":21},"不予以验收",{"key":23,"text":496,"correct":28},"应予以验收",{"key":26,"text":498,"correct":21},"协商验收",{"key":30,"text":500,"correct":21},"重新验收",{"id":502,"libraryId":5,"type":9,"typeLabel":15,"stem":503,"options":504,"answer":26,"analysis":32},1270731,"Ⅰ类卵石、碎石的含泥量应（ ）。",[505,507,509,511],{"key":19,"text":506,"correct":21},"&lt; 1.0%",{"key":23,"text":508,"correct":21},"&lt; 0.7%",{"key":26,"text":510,"correct":28},"&lt; 0.5%",{"key":30,"text":512,"correct":21},"&lt; 0.25%",{"id":514,"libraryId":5,"type":9,"typeLabel":15,"stem":515,"options":516,"answer":19,"analysis":32},1270732,"对于框架柱纵向受力钢筋接头采用电渣压力焊做法，要求每（ ）楼层（每一检验批）都要做一次抽样送检，作抗拉、抗弯的力学性能化验，并且按使用的型号、规格分别来做。",[517,518,519,520],{"key":19,"text":86,"correct":28},{"key":23,"text":88,"correct":21},{"key":26,"text":90,"correct":21},{"key":30,"text":92,"correct":21},{"id":522,"libraryId":5,"type":9,"typeLabel":15,"stem":523,"options":524,"answer":26,"analysis":32},1270733,"《混凝土结构工程施工质量验收规范》GB50204—2002（2011版），底模及其支架拆除时的混凝土强度应符合设计要求；当设计无具体要求时，梁、拱、壳构件跨度≤8M时，混凝土达到设计的混凝土立方体抗压强度标准值的（ ），方可拆除。",[525,527,529,531],{"key":19,"text":526,"correct":21},"≥25%",{"key":23,"text":528,"correct":21},"≥50%",{"key":26,"text":530,"correct":28},"≥75%",{"key":30,"text":532,"correct":21},"≥100%",{"id":534,"libraryId":5,"type":9,"typeLabel":15,"stem":535,"options":536,"answer":19,"analysis":32},1270734,"当专业验收规范对工程中的验收项目未做出相应规定时，应由（ ）组织监理、设计、施工等相关单位制定专项验收要求。涉及安全、节能、环境保护等项目的专项验收要求，应由建设单位组织专家论证。",[537,538,539,540],{"key":19,"text":308,"correct":28},{"key":23,"text":304,"correct":21},{"key":26,"text":306,"correct":21},{"key":30,"text":318,"correct":21},{"id":542,"libraryId":5,"type":9,"typeLabel":15,"stem":543,"options":544,"answer":30,"analysis":32},1270735,"大面积水泥、混凝土楼（地）面完成后应留设缩缝，横向缩缝间距按轴线尺寸，纵向缩缝间距（ ）。",[545,547,549,551],{"key":19,"text":546,"correct":21},"≤3m",{"key":23,"text":548,"correct":21},"≤4m",{"key":26,"text":550,"correct":21},"≤5m",{"key":30,"text":552,"correct":28},"≤6m",{"id":554,"libraryId":5,"type":9,"typeLabel":15,"stem":555,"options":556,"answer":30,"analysis":32},1270738,"国务院《建设工程质量管理条例》规定隐蔽工程在隐蔽前，施工单位应当通知（ ）。",[557,558,560,562],{"key":19,"text":308,"correct":21},{"key":23,"text":559,"correct":21},"建设行政主管部门",{"key":26,"text":561,"correct":21},"工程质量监督机构",{"key":30,"text":563,"correct":28},"建设单位和工程质量监督机构",{"id":565,"libraryId":5,"type":9,"typeLabel":15,"stem":566,"options":567,"answer":30,"analysis":32},1270740,"建筑幕墙工程属于（ ）工程分部。",[568,569,570,572],{"key":19,"text":326,"correct":21},{"key":23,"text":328,"correct":21},{"key":26,"text":571,"correct":21},"主体工程",{"key":30,"text":332,"correct":28},{"id":574,"libraryId":5,"type":9,"typeLabel":15,"stem":575,"options":576,"answer":26,"analysis":32},1270741,"以下不是工程竣工验收的要求的是（ ）。",[577,579,581,583],{"key":19,"text":578,"correct":21},"完成工程设计和合同约定的各项内容",{"key":23,"text":580,"correct":21},"建设单位已按合同约定支付工程款",{"key":26,"text":582,"correct":28},"有部分技术档案和施工管理资料",{"key":30,"text":584,"correct":21},"有施工单位签署的工程质量保修书",[586,589,592,595,598,601],{"id":9,"name":587,"category":7,"favorite":588},"领导干部任职前廉政法规知识测试题",92,{"id":590,"name":591,"category":7,"favorite":9},595,"建筑结构与设备",{"id":593,"name":594,"category":7,"favorite":9},715,"招标采购专业知识与法律法规",{"id":596,"name":597,"category":7,"favorite":9},848,"市政方向-通用基础",{"id":599,"name":600,"category":7,"favorite":8},534,"BIM工程师",{"id":602,"name":600,"category":7,"favorite":8},535]