[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1271906":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1271906,858,2,"多选题","某高层商业建筑位于闹市区，周边建筑物较多，地质条件复杂，地下水位较高设计采用泥浆护壁成孔灌注桩，共110根，桩径1.2m,水下C30混凝土，均为端承桩。情形1：某根灌注桩长27m，钢筋笼分段加工吊放，受力钢筋（Ф25）搭接连接采用双面电弧焊，钢筋笼内侧对称安装超声波检测管。情形2：有5根桩的混凝土标准养护试块强度不合格，经对桩体钻芯取样检测，桩体混凝土实际强度均满足要求。 关于泥浆护壁钻孔灌注桩，下列说法妥当的有（ ）。",[11,15,18,21,25],{"key":12,"text":13,"correct":14},"A","泥浆具有排渣作用",true,{"key":16,"text":17,"correct":14},"B","泥浆具有护壁作用",{"key":19,"text":20,"correct":14},"C","灌注桩浇筑顶面应高于设计标高0.5～1m",{"key":22,"text":23,"correct":24},"D","混凝土充盈系数应小于1.0",false,{"key":26,"text":27,"correct":14},"E","钢筋笼应焊接牢固，应每隔2～3m设置一层混凝土保护块","ABCE","泥浆护壁钻孔灌注桩，泥浆具有排渣作用，钢筋笼应焊接牢固，应每隔2、3m设置一层混凝土保护块，泥浆具有护壁作用，灌注桩浇筑顶面应高于设计标高0.5-1m",{"id":6,"name":31,"category":32,"favorite":33},"(土建质量)专业管理实务 岗位知识","建筑工程",0]