[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1271479":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},1271479,858,1,"单选题","关于屋面防水要求的说法，错误的是（ ）",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","屋面防水应以排为主.以防为辅",true,{"key":16,"text":17,"correct":18},"B","找坡层最薄处厚度不宜小于20mm",false,{"key":20,"text":21,"correct":18},"C","混凝土结构层宜采用结栖找坡.坡度不应小于3%",{"key":23,"text":24,"correct":18},"D","保温层上的找平层应在水泥初凝前压实抹平.并应留设分格缝","屋面防水应以防为主，以排为辅。在完善设防的基础上，应选择正确的排水坡度，将水迅速排走，以减少渗水的机会。混凝土结构层宜采用结构找坡，坡度不应小于3%;当采用材料找坡时，宜采用质量轻，吸水率低和有一定强度的材料，坡度宜为2%。找坡应按屋面排水方向和设计坡度要求进行，找坡层最薄处厚度不宜小于20mm。保温层上的找平层应在水泥初凝前压实抹平，并应留设分格缝，缝宽宜为5-20mm，纵横的间距不宜大于6m。水泥终凝前完成收水后应二次压光，并应及时取出分格条。养护时间不得少于7d。卷材防水层的基层与突出屋面结构的交接",{"id":6,"name":27,"category":28,"favorite":29},"(土建质量)专业管理实务 岗位知识","建筑工程",0]