[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1269016":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1269016,856,2,"多选题","低应变法测试参数设定应符合下列规定（ ）。",[11,15,18,21,24],{"key":12,"text":13,"correct":14},"A","时域信号记录的时间段长度应在2L\u002Fc时刻后延续不少于5ms；幅频信号分析的频率范围上限不应小于2000Hz",true,{"key":16,"text":17,"correct":14},"B","设定桩长应为桩顶测点至桩底的施工桩长，设定桩身截面积应为施工截面积",{"key":19,"text":20,"correct":14},"C","桩身波速可根据本地区同类型桩的测试值初步设定",{"key":22,"text":23,"correct":14},"D","采样时间间隔或采样频率应根据桩长、桩身波速和频域分辨率合理选择；时域信号采样点数不宜少于1024点",{"key":25,"text":26,"correct":27},"E","采样时间间隔宜为50~200μs，信号采样点数不宜少于1024点",false,"ABCD","2）测试参数设定应符合下列规定：①时域信号记录的时间段长度应在2L\u002Fc时刻后延续不少于5ms;幅频信号分析的频率范围上限不应小于2000Hz;②设定粧长应为桩顶测点至桩底的施工桩长，设定粧身截面积应为施工截面积；③桩身波速可根据本地区同类型桩的测试值初步设定；④采样时间间隔或采样频率应根据桩长、桩身波速和频域分辨率合理选择；时域信号采样点数不宜少于1024点；⑤传感器的设定值应按计量检定结果设定。",{"id":6,"name":31,"category":32,"favorite":33},"(市政质量)专业管理实务 岗位知识","建筑工程",0]