[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-854-5":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":559},{"id":5,"name":6,"category":7,"favorite":8},854,"(设备安装质量)专业管理实务 岗位知识","建筑工程",0,5,50,1024,[13,34,46,58,70,82,94,106,118,128,139,150,160,172,184,196,207,218,227,237,247,259,267,279,291,299,311,319,327,339,351,359,369,378,390,399,411,423,431,443,451,461,473,485,494,506,514,526,538,550],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},1266463,1,"单选题","绕组头尾鉴别方法中的万用表法的原理是利用转子铁芯中的剩磁在定子三相绕组内感应出（ ）来进行的。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","电压",false,{"key":24,"text":25,"correct":26},"B","电动势",true,{"key":28,"text":29,"correct":22},"C","电流",{"key":31,"text":32,"correct":22},"D","电阻","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},1266464,"低压成套配电柜、箱及控制柜（台、箱）间线路的线间和线对地间绝缘电阻值，二次回路不应小于（ ）M?。",[38,40,42,44],{"key":20,"text":39,"correct":22},"0.5",{"key":24,"text":41,"correct":26},"1.0",{"key":28,"text":43,"correct":22},"2.0",{"key":31,"text":45,"correct":22},"5.0",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},1266465,"等电位联结导体在地下暗敷时，其导体间的连接（ ）采用螺栓压接。",[50,52,54,56],{"key":20,"text":51,"correct":26},"不得",{"key":24,"text":53,"correct":22},"宜",{"key":28,"text":55,"correct":22},"可以",{"key":31,"text":57,"correct":22},"应",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},1266466,"下面不属于防雷接地装置外观检查的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"检查装置安装的完整性和连续性，连接应牢固、可靠",{"key":24,"text":65,"correct":22},"螺栓连接应有弹簧垫圈，焊接连接其搭接长度应符合要求",{"key":28,"text":67,"correct":26},"接地线可以直接穿过建筑物楼墙板，无需其他附属措施",{"key":31,"text":69,"correct":22},"接地线的规格应符合要求，接地线的色标应符合要求",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},1266467,"公用建筑照明系统通电连续试运行时间应为24h，住宅照明系统通电连续试运行时间应为（ ）h。",[74,76,78,80],{"key":20,"text":75,"correct":22},"12",{"key":24,"text":77,"correct":26},"8",{"key":28,"text":79,"correct":22},"10",{"key":31,"text":81,"correct":22},"14",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},1266468,"直埋电缆的上下应铺设黄砂层，黄砂可以用无杂物的细土替代，其铺设厚度不小于（ ）mm。",[86,88,90,92],{"key":20,"text":87,"correct":22},"50",{"key":24,"text":89,"correct":26},"100",{"key":28,"text":91,"correct":22},"150",{"key":31,"text":93,"correct":22},"200",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":28,"analysis":33},1266469,"金属钢导管间以专用接地卡固定的保护连接导体应为铜芯软导线，截面积不应小于（ ）m㎡。",[98,100,102,104],{"key":20,"text":99,"correct":22},"1.5",{"key":24,"text":101,"correct":22},"2.5",{"key":28,"text":103,"correct":26},"4.0",{"key":31,"text":105,"correct":22},"6.0",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":31,"analysis":33},1266470,"电缆的导体，在建筑电气工程中均为（ ）导体。",[110,112,114,116],{"key":20,"text":111,"correct":22},"铁芯",{"key":24,"text":113,"correct":22},"钢芯",{"key":28,"text":115,"correct":22},"铝芯",{"key":31,"text":117,"correct":26},"铜芯",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},1266471,"刚性导管经柔性导管与电气设备、器具连接，柔性导管的长度在动力工程中不宜大于0.8m，在照明工程中不宜大于（ ）m。",[122,123,125,127],{"key":20,"text":41,"correct":22},{"key":24,"text":124,"correct":26},"1.2",{"key":28,"text":126,"correct":22},"2",{"key":31,"text":99,"correct":22},{"id":129,"libraryId":5,"type":15,"typeLabel":16,"stem":130,"options":131,"answer":31,"analysis":33},1266472,"母线采用螺栓搭接时，连接处距绝缘子的支持夹板边缘不小于（ ）mm。",[132,134,136,138],{"key":20,"text":133,"correct":22},"20",{"key":24,"text":135,"correct":22},"30",{"key":28,"text":137,"correct":22},"40",{"key":31,"text":87,"correct":26},{"id":140,"libraryId":5,"type":15,"typeLabel":16,"stem":141,"options":142,"answer":31,"analysis":33},1266473,"埋人土壤中的热浸镀锌钢材应检测其镀锌层厚度不应小于（ ）μm。",[143,144,146,148],{"key":20,"text":75,"correct":22},{"key":24,"text":145,"correct":22},"38",{"key":28,"text":147,"correct":22},"47",{"key":31,"text":149,"correct":26},"63",{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":28,"analysis":33},1266474,"低压电动机、电加热器及电动执行机构的绝缘电阻值不应小于（ ）M?。",[154,156,158,159],{"key":20,"text":155,"correct":22},"0.1",{"key":24,"text":157,"correct":22},"0.2",{"key":28,"text":39,"correct":26},{"key":31,"text":41,"correct":22},{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":20,"analysis":33},1266475,"电气设备的外露可导电部分应单独与保护导体相连接，不得（ ）连接，连接导体的材质、截面积应符合设计要求。",[164,166,168,170],{"key":20,"text":165,"correct":26},"串联",{"key":24,"text":167,"correct":22},"并联",{"key":28,"text":169,"correct":22},"焊接",{"key":31,"text":171,"correct":22},"螺栓",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":28,"analysis":33},1266476,"采用钢管作灯具吊杆时，其内径不应小于（ ）mm，壁厚不应小于（ ）mm。",[176,178,180,182],{"key":20,"text":177,"correct":22},"61.5",{"key":24,"text":179,"correct":22},"101.0",{"key":28,"text":181,"correct":26},"101.5",{"key":31,"text":183,"correct":22},"62.0",{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":31,"analysis":33},1266477,"配电箱（盘）内的剩余电流动作保护器（RC D）应在施加（ ）的情况下测试动作时间，测试值应符合设计要求。",[188,190,192,194],{"key":20,"text":189,"correct":22},"剩余电流",{"key":24,"text":191,"correct":22},"工作电流",{"key":28,"text":193,"correct":22},"漏电电流",{"key":31,"text":195,"correct":26},"额定剩余动作电流",{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":24,"analysis":33},1266478,"镀锌梯架、托盘和槽盒本体之间不跨接保护联结导体时，连接板每端不应少于（ ）个有防松螺帽或防松垫圈的连接固定螺栓。",[200,202,203,205],{"key":20,"text":201,"correct":22},"1",{"key":24,"text":126,"correct":26},{"key":28,"text":204,"correct":22},"3",{"key":31,"text":206,"correct":22},"4",{"id":208,"libraryId":5,"type":15,"typeLabel":16,"stem":209,"options":210,"answer":24,"analysis":33},1266479,"当塑料导管在砖墙体上剔槽埋设时，应采用强度等级不少于M10的水泥砂浆抹面保护，保护层厚度不应小于（ ）mm。",[211,212,214,216],{"key":20,"text":79,"correct":22},{"key":24,"text":213,"correct":26},"15",{"key":28,"text":215,"correct":22},"25",{"key":31,"text":217,"correct":22},"24",{"id":219,"libraryId":5,"type":15,"typeLabel":16,"stem":220,"options":221,"answer":24,"analysis":33},1266480,"电动机空载状态下可启动次数及间隔时间应符合产品技术条件的要求；无要求时，连续启动2次的时间间隔不应小于（ ）min，再次启动应在电动机冷却至常温下再进行。",[222,223,225,226],{"key":20,"text":126,"correct":22},{"key":24,"text":224,"correct":26},"5",{"key":28,"text":77,"correct":22},{"key":31,"text":79,"correct":22},{"id":228,"libraryId":5,"type":15,"typeLabel":16,"stem":229,"options":230,"answer":28,"analysis":33},1266481,"当不采用安全型插座时，托儿所、幼儿园及小学等儿童活动场所安装高度不小于（ ）m",[231,232,234,236],{"key":20,"text":124,"correct":22},{"key":24,"text":233,"correct":22},"1.6",{"key":28,"text":235,"correct":26},"1.8",{"key":31,"text":43,"correct":22},{"id":238,"libraryId":5,"type":15,"typeLabel":16,"stem":239,"options":240,"answer":28,"analysis":33},1266482,"送电验收工作中，需送电空载运行（ ）h，无异常现象，办理验收手续，交建设单位使用。",[241,243,244,245],{"key":20,"text":242,"correct":22},"6",{"key":24,"text":75,"correct":22},{"key":28,"text":217,"correct":26},{"key":31,"text":246,"correct":22},"48",{"id":248,"libraryId":5,"type":15,"typeLabel":16,"stem":249,"options":250,"answer":31,"analysis":33},1266483,"安装工程中，应用（ ）水准仪已能满足要求。",[251,253,255,257],{"key":20,"text":252,"correct":22},"DS0.5",{"key":24,"text":254,"correct":22},"DS1",{"key":28,"text":256,"correct":22},"DS3",{"key":31,"text":258,"correct":26},"DS10",{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":31,"analysis":33},1266484,"塑料护套线在室内垂直敷设时，距地面高度（ ）m以下的部分应有保护。",[263,264,265,266],{"key":20,"text":41,"correct":22},{"key":24,"text":124,"correct":22},{"key":28,"text":99,"correct":22},{"key":31,"text":235,"correct":26},{"id":268,"libraryId":5,"type":15,"typeLabel":16,"stem":269,"options":270,"answer":28,"analysis":33},1266485,"当采用角钢作为人工接地装置时，（ ）不符合规范要求。",[271,273,275,277],{"key":20,"text":272,"correct":22},"顶面埋设深度为0.7m",{"key":24,"text":274,"correct":22},"垂直埋于地下，间距为5m",{"key":28,"text":276,"correct":26},"扁钢引下线与角钢焊接时紧贴角钢内侧两面上下两侧施焊",{"key":31,"text":278,"correct":22},"施焊部位除埋设在混凝土外，有防腐措施。",{"id":280,"libraryId":5,"type":15,"typeLabel":16,"stem":281,"options":282,"answer":20,"analysis":33},1266486,"明配的电气导管应符合下列要求：（ ）。",[283,285,287,289],{"key":20,"text":284,"correct":26},"在距导管终端、弯头中点或柜、台、箱、盘等边缘0~150mm范围内应设有固定",{"key":24,"text":286,"correct":22},"在距导管终端、弯头中点或柜、台、箱、盘等边缘150~500mm范围内应设有固定管卡",{"key":28,"text":288,"correct":22},"导管应排列整齐、固定点间距均匀、安装牢固",{"key":31,"text":290,"correct":22},"导管采用的接线或过渡盒（箱）应选用明装盒（箱）",{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":24,"analysis":33},1266487,"用1000V兆欧表测量封闭插接式母线槽冷态绝缘电阻，每段不得小于（ ）兆欧",[295,296,297,298],{"key":20,"text":79,"correct":22},{"key":24,"text":133,"correct":26},{"key":28,"text":135,"correct":22},{"key":31,"text":137,"correct":22},{"id":300,"libraryId":5,"type":15,"typeLabel":16,"stem":301,"options":302,"answer":28,"analysis":33},1266488,"对灯具的绝缘性能进行现场抽样检测，灯具的绝缘电阻值不应小于（ ）M?，灯具内绝缘导线的绝缘层厚度不应小于0.6mm。",[303,305,307,309],{"key":20,"text":304,"correct":22},"0.5M?",{"key":24,"text":306,"correct":22},"1M?",{"key":28,"text":308,"correct":26},"2M?",{"key":31,"text":310,"correct":22},"5M?",{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":24,"analysis":33},1266489,"建筑物室内部配电线路的配电形式有暗配线路和明配线路两种。导线沿墙壁、顶棚、桁架及梁柱等布线为明配敷设；导线埋设在墙内、空心板内、地坪内和布设在顶棚内等布线方式为暗配敷设。室内配线不仅要求安全可靠，满足使用功能，而且要求布局合理、整齐、牢固。请回答下列问题： 暗配厚壁金属电线管进入盒（箱）的管子其套丝长度不宜小于管外径的（ ）倍。",[315,316,317,318],{"key":20,"text":201,"correct":22},{"key":24,"text":99,"correct":26},{"key":28,"text":126,"correct":22},{"key":31,"text":101,"correct":22},{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":31,"analysis":33},1266490,"质量大于10kg的灯具，固定装置及悬吊装置应按灯具重量的（ ）倍恒定均布载荷做强度试验，持续时间不得少于15min。",[323,324,325,326],{"key":20,"text":126,"correct":22},{"key":24,"text":204,"correct":22},{"key":28,"text":206,"correct":22},{"key":31,"text":224,"correct":26},{"id":328,"libraryId":5,"type":15,"typeLabel":16,"stem":329,"options":330,"answer":31,"analysis":33},1266491,"不属于可挠金属导管敷设敷设的的优点的是（ ）。",[331,333,335,337],{"key":20,"text":332,"correct":22},"敷设方便",{"key":24,"text":334,"correct":22},"施工操作简单",{"key":28,"text":336,"correct":22},"安装时不受建筑部位影响",{"key":31,"text":338,"correct":26},"价格低廉",{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":28,"analysis":33},1266492,"人工垂直接地体的长度宜为（ ）m，人工垂直接地体之间的间距不宜小于（ ）m。人工接地体与建筑物外墙或基础之间的水平距离不宜小于（ ）m。",[343,345,347,349],{"key":20,"text":344,"correct":22},"2.041",{"key":24,"text":346,"correct":22},"2.550.5",{"key":28,"text":348,"correct":26},"2.551",{"key":31,"text":350,"correct":22},"341",{"id":352,"libraryId":5,"type":15,"typeLabel":16,"stem":353,"options":354,"answer":31,"analysis":33},1266493,"在建筑物外人员可经过或停留的引下线与接地体连接处（ ）m范围内，应采用防止跨步电压对人员造成伤害的措施。",[355,356,357,358],{"key":20,"text":39,"correct":22},{"key":24,"text":201,"correct":22},{"key":28,"text":126,"correct":22},{"key":31,"text":204,"correct":26},{"id":360,"libraryId":5,"type":15,"typeLabel":16,"stem":361,"options":362,"answer":31,"analysis":33},1266494,"专用接闪杆应能承受0.7kN\u002F㎡的基本风压，在经常发生台风和大于（ ）级大风的地区，宜增大接闪杆的尺寸。",[363,364,366,367],{"key":20,"text":77,"correct":22},{"key":24,"text":365,"correct":22},"9",{"key":28,"text":79,"correct":22},{"key":31,"text":368,"correct":26},"11",{"id":370,"libraryId":5,"type":15,"typeLabel":16,"stem":371,"options":372,"answer":24,"analysis":33},1266495,"根据《建筑物防雷设计规范》GB50057-2010的有关规定，第二类防雷建筑物专设引下线不应少于两根，并应沿建筑物周围均匀布设，其平均间距不应大于（ ）。",[373,374,376,377],{"key":20,"text":75,"correct":22},{"key":24,"text":375,"correct":26},"18",{"key":28,"text":215,"correct":22},{"key":31,"text":135,"correct":22},{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":24,"analysis":33},1266496,"制冷管道系统应进行强度、气密性试验及（ ），且必须合格。",[382,384,386,388],{"key":20,"text":383,"correct":22},"严密性试验",{"key":24,"text":385,"correct":26},"真空试验",{"key":28,"text":387,"correct":22},"水压试验",{"key":31,"text":389,"correct":22},"泄漏试验",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":20,"analysis":33},1266497,"在风管穿过需要防火的楼板时，需要用钢管，并且钢板厚度不应小于（ ）mm",[394,395,396,397],{"key":20,"text":233,"correct":26},{"key":24,"text":43,"correct":22},{"key":28,"text":101,"correct":22},{"key":31,"text":398,"correct":22},"3.0",{"id":400,"libraryId":5,"type":15,"typeLabel":16,"stem":401,"options":402,"answer":20,"analysis":33},1266498,"消声器、消声弯管均应设（ ），其重量不得由两端风管承担。",[403,405,407,409],{"key":20,"text":404,"correct":26},"独立支、吊架",{"key":24,"text":406,"correct":22},"防晃支、吊架",{"key":28,"text":408,"correct":22},"支、吊架",{"key":31,"text":410,"correct":22},"承重支、吊架",{"id":412,"libraryId":5,"type":15,"typeLabel":16,"stem":413,"options":414,"answer":20,"analysis":33},1266499,"燃油管道系统必须设置可靠的（ ）装置，其管道法兰应采用镀锌螺栓连接或在法兰处用铜导管线进行跨接，且结合良好。",[415,417,419,421],{"key":20,"text":416,"correct":26},"防静电接地",{"key":24,"text":418,"correct":22},"接地",{"key":28,"text":420,"correct":22},"防雷击",{"key":31,"text":422,"correct":22},"防腐蚀接地",{"id":424,"libraryId":5,"type":15,"typeLabel":16,"stem":425,"options":426,"answer":28,"analysis":33},1266500,"中压圆形金属风管的允许漏风量，应为矩形风管规定值的（ ）%",[427,428,429,430],{"key":20,"text":135,"correct":22},{"key":24,"text":137,"correct":22},{"key":28,"text":87,"correct":26},{"key":31,"text":89,"correct":22},{"id":432,"libraryId":5,"type":15,"typeLabel":16,"stem":433,"options":434,"answer":28,"analysis":33},1266501,"立式水泵宜采用（ ）隔振器，并要求水泵机组隔振元件支承点应为偶数，且不少于（ ）个",[435,437,439,441],{"key":20,"text":436,"correct":22},"阻尼弹簧4",{"key":24,"text":438,"correct":22},"阻尼弹簧6",{"key":28,"text":440,"correct":26},"橡胶4",{"key":31,"text":442,"correct":22},"橡胶6",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":24,"analysis":33},1266502,"风管接口的连接应严密、牢固。风管法兰的垫片材质应符合系统功能的要求，厚度不应小于（ ）mm。垫片不应凸人管内，亦不宜突出法兰外。",[447,448,449,450],{"key":20,"text":224,"correct":22},{"key":24,"text":204,"correct":26},{"key":28,"text":126,"correct":22},{"key":31,"text":206,"correct":22},{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":453,"options":454,"answer":24,"analysis":33},1266503,"防火阀、排烟阀（口）的安装方向、位置应正确。防火分区隔墙两侧的防火阀，距墙表面不应大于（ ）mm。",[455,456,457,459],{"key":20,"text":89,"correct":22},{"key":24,"text":93,"correct":26},{"key":28,"text":458,"correct":22},"1000",{"key":31,"text":460,"correct":22},"800",{"id":462,"libraryId":5,"type":15,"typeLabel":16,"stem":463,"options":464,"answer":28,"analysis":33},1266504,"通风机传动装置的外露部位以及直通大气的进、出口，必须装设（ ）或采取其他安全设施。",[465,467,469,471],{"key":20,"text":466,"correct":22},"防雨罩",{"key":24,"text":468,"correct":22},"防尘罩",{"key":28,"text":470,"correct":26},"防护罩（网）",{"key":31,"text":472,"correct":22},"安全网",{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":24,"analysis":33},1266505,"通风与空调工程施工质量的保修期限，自竣工验收合格日起计算为（ ）供暖期、供冷期。",[477,479,481,483],{"key":20,"text":478,"correct":22},"一个",{"key":24,"text":480,"correct":26},"二个",{"key":28,"text":482,"correct":22},"三个",{"key":31,"text":484,"correct":22},"四个",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":28,"analysis":33},1266506,"有防潮隔汽层绝热材料的拼缝处，应用粘胶带封严，粘胶带的宽度不应小于（ ）mm。粘胶带应牢固地粘贴在防潮面层上，不得有胀裂和脱落。",[489,490,491,492],{"key":20,"text":135,"correct":22},{"key":24,"text":137,"correct":22},{"key":28,"text":87,"correct":26},{"key":31,"text":493,"correct":22},"60",{"id":495,"libraryId":5,"type":15,"typeLabel":16,"stem":496,"options":497,"answer":20,"analysis":33},1266507,"（ ）属于空调系统的附属系统，负责提供空气处理过程中所需的冷量和热量，制冷装置是制冷系统的核心。",[498,500,502,504],{"key":20,"text":499,"correct":26},"冷热源系统",{"key":24,"text":501,"correct":22},"空气处理系统",{"key":28,"text":503,"correct":22},"能量输送分配系统",{"key":31,"text":505,"correct":22},"自动控制系统",{"id":507,"libraryId":5,"type":15,"typeLabel":16,"stem":508,"options":509,"answer":20,"analysis":33},1266508,"风管垂直安装，支、吊架的间距应不大于（ ）m且每根立管的固定件不应小于2个。",[510,511,512,513],{"key":20,"text":206,"correct":26},{"key":24,"text":204,"correct":22},{"key":28,"text":224,"correct":22},{"key":31,"text":242,"correct":22},{"id":515,"libraryId":5,"type":15,"typeLabel":16,"stem":516,"options":517,"answer":31,"analysis":33},1266509,"冷凝水排水管坡度，应符合设计文件的规定。当设计无规定时，其坡度宜大于或等于（ ）；软管连接的长度，不宜大于150mm。",[518,520,522,524],{"key":20,"text":519,"correct":22},"10‰",{"key":24,"text":521,"correct":22},"6‰",{"key":28,"text":523,"correct":22},"5‰",{"key":31,"text":525,"correct":26},"8‰",{"id":527,"libraryId":5,"type":15,"typeLabel":16,"stem":528,"options":529,"answer":20,"analysis":33},1266510,"各类耐压塑料管的强度试验压力为1.5倍（ ），严密性试验压力为1.15倍的（ ）。",[530,532,534,536],{"key":20,"text":531,"correct":26},"工作压力设计工作压力",{"key":24,"text":533,"correct":22},"工作压力工作压力",{"key":28,"text":535,"correct":22},"设计工作压力设计工作压力",{"key":31,"text":537,"correct":22},"设计工作压力工作压力",{"id":539,"libraryId":5,"type":15,"typeLabel":16,"stem":540,"options":541,"answer":24,"analysis":33},1266511,"相邻不同级别洁净室之间和洁净室与非洁净室之间的静压差不应小于（ ）Pa，洁净室与室外的静压差不应小于（ ）Pa",[542,544,546,548],{"key":20,"text":543,"correct":22},"55",{"key":24,"text":545,"correct":26},"510",{"key":28,"text":547,"correct":22},"1010",{"key":31,"text":549,"correct":22},"1015",{"id":551,"libraryId":5,"type":15,"typeLabel":16,"stem":552,"options":553,"answer":20,"analysis":33},1266512,"管道的固定焊口应远离设备，且不宜与设备接口中心线相重合。管道对接焊缝与支、吊架的距离应大于（ ）mm。",[554,555,556,557],{"key":20,"text":87,"correct":26},{"key":24,"text":493,"correct":22},{"key":28,"text":135,"correct":22},{"key":31,"text":558,"correct":22},"80",[560,563,566,569,572,575],{"id":15,"name":561,"category":7,"favorite":562},"领导干部任职前廉政法规知识测试题",92,{"id":564,"name":565,"category":7,"favorite":15},595,"建筑结构与设备",{"id":567,"name":568,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":570,"name":571,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":573,"name":574,"category":7,"favorite":8},534,"BIM工程师",{"id":576,"name":574,"category":7,"favorite":8},535]