[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-854-4":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":549},{"id":5,"name":6,"category":7,"favorite":8},854,"(设备安装质量)专业管理实务 岗位知识","建筑工程",0,4,50,1024,[13,34,46,58,70,82,94,104,116,128,140,152,162,174,182,194,204,212,220,229,241,253,265,273,282,294,306,318,326,334,342,353,365,377,389,398,410,419,431,439,450,458,470,478,489,497,509,517,529,537],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},1266413,1,"单选题","关于室外消火栓系统的选择，（ ）消火栓适用于气温较高的地方，（ ）消火栓适用于较寒冷的地区。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","地上地下",true,{"key":24,"text":25,"correct":26},"B","地上地上",false,{"key":28,"text":29,"correct":26},"C","地下地上",{"key":31,"text":32,"correct":26},"D","地下地下","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},1266414,"（ ）可以表达供电方式和电能分配的关系，也可表达一个大型用电设备各用电点的配电关系。",[38,40,42,44],{"key":20,"text":39,"correct":22},"系统图",{"key":24,"text":41,"correct":26},"电路图",{"key":28,"text":43,"correct":26},"设备布置图",{"key":31,"text":45,"correct":26},"平面图",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},1266415,"刚性导管经柔性导管与电气设备、器具连接，柔性导管的长度在动力工程中不宜大于（ ）m，在照明工程中不宜大于（ ）m。",[50,52,54,56],{"key":20,"text":51,"correct":26},"0.5 0.8",{"key":24,"text":53,"correct":22},"0.8 1.2",{"key":28,"text":55,"correct":26},"1.2 1.5",{"key":31,"text":57,"correct":26},"1.5 1.8",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},1266416,"根据《建筑电气工程施工质量验收规范》GB50303-2015规定，柜、台、箱的金属框架及基础型钢应与保护导体可靠连接；装有电器的可开启门，门和金属框架的接地端子间应选用截面积不小于（ ）m㎡黄绿色绝缘铜芯软导线连接，且有标识。",[62,64,66,68],{"key":20,"text":63,"correct":26},"1.5",{"key":24,"text":65,"correct":26},"2.5",{"key":28,"text":67,"correct":22},"4",{"key":31,"text":69,"correct":26},"6",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},1266417,"住宅照明系统通电连续试运行时间应为（ ）h。所有照明灯具均应同时开启，且每2h按回路记录运行参数，连续试运行时间内应无故障。",[74,76,78,80],{"key":20,"text":75,"correct":22},"8",{"key":24,"text":77,"correct":26},"10",{"key":28,"text":79,"correct":26},"12",{"key":31,"text":81,"correct":26},"24",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},1266418,"导管敷设中的补偿装置应该用（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":26},"刚性导管",{"key":24,"text":89,"correct":22},"柔性导管",{"key":28,"text":91,"correct":26},"塑料导管",{"key":31,"text":93,"correct":26},"可挠性导管",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":28,"analysis":33},1266419,"送电运行当中，第一次与第二次的合闸时间一般间隔（ ）min。",[98,100,101,103],{"key":20,"text":99,"correct":26},"3",{"key":24,"text":67,"correct":26},{"key":28,"text":102,"correct":22},"5",{"key":31,"text":69,"correct":26},{"id":105,"libraryId":5,"type":15,"typeLabel":16,"stem":106,"options":107,"answer":24,"analysis":33},1266420,"下面不属于灯具调试过程的是（ ）。",[108,110,112,114],{"key":20,"text":109,"correct":26},"线路绝缘电阻测试",{"key":24,"text":111,"correct":22},"线路防腐测试",{"key":28,"text":113,"correct":26},"照度检测",{"key":31,"text":115,"correct":26},"照明全负荷通电试运行",{"id":117,"libraryId":5,"type":15,"typeLabel":16,"stem":118,"options":119,"answer":31,"analysis":33},1266421,"下面的选项叙述错误的是（ ）。",[120,122,124,126],{"key":20,"text":121,"correct":26},"在木结构或轻钢龙骨护板墙上暗装配电箱时，应采用加固措施",{"key":24,"text":123,"correct":26},"配管在护板墙内暗敷设时，要求箱口应与墙面平齐",{"key":28,"text":125,"correct":26},"在木制护墙处应做防火处理",{"key":31,"text":127,"correct":22},"在木制护墙处应做绝缘处理",{"id":129,"libraryId":5,"type":15,"typeLabel":16,"stem":130,"options":131,"answer":28,"analysis":33},1266422,"下列（ ）符合接地装置采用扁钢与扁钢搭接焊的规定。",[132,134,136,138],{"key":20,"text":133,"correct":26},"扁钢与扁钢搭接不应小于扁钢宽度的1倍，且应不少于三面施焊",{"key":24,"text":135,"correct":26},"扁钢与扁钢搭接不应小于扁钢宽度的2倍，且应不少于双面施焊",{"key":28,"text":137,"correct":22},"扁钢与扁钢搭接不应小于扁钢宽度的2倍，且应不少于三面施焊",{"key":31,"text":139,"correct":26},"扁钢与扁钢搭接不应小于扁钢宽度的1倍，且应四面施焊",{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":24,"analysis":33},1266423,"建筑电气动力工程的空载试运行和建筑电气照明工程的负荷试运行，应按本规范规定执行；建筑电气动力工程的负荷试运行，依据电气设备及相关建筑设备的种类、特性，编制试运行方案或作业指导书，并应经施工单位审查批准，试运行方案应经（ ）确认后执行。",[144,146,148,150],{"key":20,"text":145,"correct":26},"建设单位",{"key":24,"text":147,"correct":22},"监理单位",{"key":28,"text":149,"correct":26},"设计单位",{"key":31,"text":151,"correct":26},"施工单位",{"id":153,"libraryId":5,"type":15,"typeLabel":16,"stem":154,"options":155,"answer":24,"analysis":33},1266424,"梯架、托盘和槽盒全长不大于30m时，应不少于（ ）处与保护导体可靠连接，全长大于30m时，每个2~3m应增加连接点，起始端和终点端均应可靠接地。",[156,158,160,161],{"key":20,"text":157,"correct":26},"1",{"key":24,"text":159,"correct":22},"2",{"key":28,"text":99,"correct":26},{"key":31,"text":67,"correct":26},{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":164,"options":165,"answer":31,"analysis":33},1266425,"接闪带每个固定支架应能承受（ ）的垂直拉力。",[166,168,170,172],{"key":20,"text":167,"correct":26},"2kg",{"key":24,"text":169,"correct":26},"3kg",{"key":28,"text":171,"correct":26},"4kg",{"key":31,"text":173,"correct":22},"5kg",{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":176,"options":177,"answer":24,"analysis":33},1266426,"可挠金属导管明配时，当导管出现弯曲时，其弯曲半径不应小于管外径的（ ）倍。",[178,179,180,181],{"key":20,"text":159,"correct":26},{"key":24,"text":99,"correct":22},{"key":28,"text":67,"correct":26},{"key":31,"text":102,"correct":26},{"id":183,"libraryId":5,"type":15,"typeLabel":16,"stem":184,"options":185,"answer":20,"analysis":33},1266427,"明敷的引下线应选用（ ）材料，敷设前应先将所需扁钢或圆钢调直，将引下线竖立提起，然后由上而下逐点固定于支持件上，直至安装于断接卡子处。",[186,188,190,192],{"key":20,"text":187,"correct":22},"镀锌",{"key":24,"text":189,"correct":26},"不锈钢",{"key":28,"text":191,"correct":26},"镀银",{"key":31,"text":193,"correct":26},"铸铁",{"id":195,"libraryId":5,"type":15,"typeLabel":16,"stem":196,"options":197,"answer":28,"analysis":33},1266428,"当塑料导管在砌体上剔槽埋设时，应采用强度等级不小于M10的水泥砂浆抹面保护，保护层厚度不应小于（ ）mm。",[198,199,200,202],{"key":20,"text":102,"correct":26},{"key":24,"text":77,"correct":26},{"key":28,"text":201,"correct":22},"15",{"key":31,"text":203,"correct":26},"20",{"id":205,"libraryId":5,"type":15,"typeLabel":16,"stem":206,"options":207,"answer":24,"analysis":33},1266429,"吊扇挂钩安装时，挂钩直径不小于吊扇挂销直径，且不小于（ ）mm。",[208,209,210,211],{"key":20,"text":69,"correct":26},{"key":24,"text":75,"correct":22},{"key":28,"text":77,"correct":26},{"key":31,"text":79,"correct":26},{"id":213,"libraryId":5,"type":15,"typeLabel":16,"stem":214,"options":215,"answer":24,"analysis":33},1266430,"镀锌钢导管或壁厚小于等于（ ）mm的钢导管，不得采用套管熔焊连接。",[216,217,218,219],{"key":20,"text":157,"correct":26},{"key":24,"text":159,"correct":22},{"key":28,"text":99,"correct":26},{"key":31,"text":67,"correct":26},{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":31,"analysis":33},1266431,"消防应急照明线路在非燃烧体内穿钢导管暗敷时，暗敷钢导管保护层厚度不小于（ ）mm。",[224,225,226,227],{"key":20,"text":77,"correct":26},{"key":24,"text":201,"correct":26},{"key":28,"text":203,"correct":26},{"key":31,"text":228,"correct":22},"30",{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":28,"analysis":33},1266432,"母线槽跨越建筑物变形缝处，应设置补偿装置；母线槽直线敷设长度超过（ ）m，每50~60m宜设置伸缩节。",[233,235,237,239],{"key":20,"text":234,"correct":26},"60",{"key":24,"text":236,"correct":26},"70",{"key":28,"text":238,"correct":22},"80",{"key":31,"text":240,"correct":26},"90",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":28,"analysis":33},1266433,"对于钢导管而言，无论是明敷还是暗敷，一般都采用（ ）连接，特别是潮湿场所，以及埋地和防爆的配管。",[245,247,249,251],{"key":20,"text":246,"correct":26},"套管扣压式",{"key":24,"text":248,"correct":26},"套接紧订式",{"key":28,"text":250,"correct":22},"丝扣",{"key":31,"text":252,"correct":26},"套管",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":20,"analysis":33},1266434,"交流单芯电缆或分相后的每相电缆（ ）单根独穿于钢导管内，固定用的夹具和支架，不应形成闭合磁路。",[257,259,261,263],{"key":20,"text":258,"correct":22},"不得",{"key":24,"text":260,"correct":26},"宜",{"key":28,"text":262,"correct":26},"应",{"key":31,"text":264,"correct":26},"可以",{"id":266,"libraryId":5,"type":15,"typeLabel":16,"stem":267,"options":268,"answer":24,"analysis":33},1266435,"钢导管不得采用对口熔焊连接；镀锌钢导管或壁厚小于等于（ ）mm的钢导管，不得采用套管熔焊连接。",[269,270,271,272],{"key":20,"text":157,"correct":26},{"key":24,"text":159,"correct":22},{"key":28,"text":99,"correct":26},{"key":31,"text":67,"correct":26},{"id":274,"libraryId":5,"type":15,"typeLabel":16,"stem":275,"options":276,"answer":20,"analysis":33},1266436,"吊扇的安装，扇叶距地高度不应小于（ ）。",[277,278,279,280],{"key":20,"text":65,"correct":22},{"key":24,"text":159,"correct":26},{"key":28,"text":63,"correct":26},{"key":31,"text":281,"correct":26},"1.3",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":24,"analysis":33},1266437,"主要用于动力和照明的电压范围是（ ）V到1000V",[286,288,290,292],{"key":20,"text":287,"correct":26},"36",{"key":24,"text":289,"correct":22},"220",{"key":28,"text":291,"correct":26},"380",{"key":31,"text":293,"correct":26},"420",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":20,"analysis":33},1266438,"槽盒内的绝缘导线总截面积（包括外护套）不应超过槽盒内截面积的（ ）且载流导体不宜超过30根。",[298,300,302,304],{"key":20,"text":299,"correct":22},"40％",{"key":24,"text":301,"correct":26},"50％",{"key":28,"text":303,"correct":26},"60％",{"key":31,"text":305,"correct":26},"70％",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":28,"analysis":33},1266439,"进人配电（控制）柜、台、箱内的导管管口，箱底无封板的，管口应高出柜、台、箱、盘的基础面（ ）mm。",[310,312,314,316],{"key":20,"text":311,"correct":26},"10~20",{"key":24,"text":313,"correct":26},"20~30",{"key":28,"text":315,"correct":22},"50~80",{"key":31,"text":317,"correct":26},"30~40",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":20,"analysis":33},1266440,"当设计无要求时，梯架、托架和槽盒垂直安装的支架间距不应大于（ ）m。",[322,323,324,325],{"key":20,"text":159,"correct":22},{"key":24,"text":65,"correct":26},{"key":28,"text":99,"correct":26},{"key":31,"text":67,"correct":26},{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":20,"analysis":33},1266441,"电线穿墙时应装过墙管保护，并且过墙管两端伸出墙面的距离不小于（ ）mm。",[330,331,332,333],{"key":20,"text":77,"correct":22},{"key":24,"text":201,"correct":26},{"key":28,"text":203,"correct":26},{"key":31,"text":228,"correct":26},{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":20,"analysis":33},1266442,"直线段钢制或塑料梯架、托盘和槽盒长度超过（ ）m、铝合金或玻璃钢制梯架、托盘和槽盒长度超过15m时，应设有伸缩节；梯架、托盘和槽盒跨越建筑物变形缝处，应设置补偿装置。",[338,339,340,341],{"key":20,"text":228,"correct":22},{"key":24,"text":203,"correct":26},{"key":28,"text":201,"correct":26},{"key":31,"text":77,"correct":26},{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":24,"analysis":33},1266443,"当设计无要求时，全塑型电力电缆垂直敷设敷设，其支持点间距不应大于（ ）m。",[346,348,350,351],{"key":20,"text":347,"correct":26},"0.5",{"key":24,"text":349,"correct":22},"1.0",{"key":28,"text":63,"correct":26},{"key":31,"text":352,"correct":26},"2.0",{"id":354,"libraryId":5,"type":15,"typeLabel":16,"stem":355,"options":356,"answer":20,"analysis":33},1266444,"在对梯架、托盘和槽盒进行外观检查时，对（ ）有异议时，应按批抽样送有资质的试验室检测。",[357,359,361,363],{"key":20,"text":358,"correct":22},"阻燃性能",{"key":24,"text":360,"correct":26},"尺寸",{"key":28,"text":362,"correct":26},"壁厚",{"key":31,"text":364,"correct":26},"涂层",{"id":366,"libraryId":5,"type":15,"typeLabel":16,"stem":367,"options":368,"answer":20,"analysis":33},1266445,"下面不属于室内灯具主要安装方式的是（ ）。",[369,371,373,375],{"key":20,"text":370,"correct":22},"组装式",{"key":24,"text":372,"correct":26},"吸顶式",{"key":28,"text":374,"correct":26},"嵌入式",{"key":31,"text":376,"correct":26},"吸壁式",{"id":378,"libraryId":5,"type":15,"typeLabel":16,"stem":379,"options":380,"answer":20,"analysis":33},1266446,"下列（ ）不是验收建筑电气工程时，应核查的质量控制资料。",[381,383,385,387],{"key":20,"text":382,"correct":22},"竣工图",{"key":24,"text":384,"correct":26},"隐蔽工程检查记录",{"key":28,"text":386,"correct":26},"电气设备交接试验检验记录",{"key":31,"text":388,"correct":26},"接闪线和接闪带固定支架的垂直拉力测试记录",{"id":390,"libraryId":5,"type":15,"typeLabel":16,"stem":391,"options":392,"answer":28,"analysis":33},1266447,"下列不属于导管以刚度分类的选项是（ ）。",[393,394,395,396],{"key":20,"text":87,"correct":26},{"key":24,"text":89,"correct":26},{"key":28,"text":91,"correct":22},{"key":31,"text":397,"correct":26},"可挠性导管三类",{"id":399,"libraryId":5,"type":15,"typeLabel":16,"stem":400,"options":401,"answer":31,"analysis":33},1266448,"建筑物室内部配电线路的配电形式有暗配线路和明配线路两种。导线沿墙壁、顶棚、桁架及梁柱等布线为明配敷设；导线埋设在墙内、空心板内、地坪内和布设在顶棚内等布线方式为暗配敷设。室内配线不仅要求安全可靠，满足使用功能，而且要求布局合理、整齐、牢固。请回答下列问题： 暗配厚壁金属电线管管路的弯曲度应不大于管外径的10%，弯曲角度不宜小于（ ）。",[402,404,406,408],{"key":20,"text":403,"correct":26},"30°",{"key":24,"text":405,"correct":26},"45°",{"key":28,"text":407,"correct":26},"60°",{"key":31,"text":409,"correct":22},"90°",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":24,"analysis":33},1266449,"梯架、托盘和槽盒全长不大于30m时，应不少于2处与保护导体可靠连接，全长大于30m时，每隔（ ）m应增加连接点，起始端和终点端均应可靠接地。",[414,415,416,417],{"key":20,"text":311,"correct":26},{"key":24,"text":313,"correct":22},{"key":28,"text":317,"correct":26},{"key":31,"text":418,"correct":26},"40~50",{"id":420,"libraryId":5,"type":15,"typeLabel":16,"stem":421,"options":422,"answer":31,"analysis":33},1266450,"在室外敷设过程中，要将接地干线末端露出地面，以便续接接地线，其高度不宜超过（ ）mm。",[423,425,427,429],{"key":20,"text":424,"correct":26},"200",{"key":24,"text":426,"correct":26},"300",{"key":28,"text":428,"correct":26},"400",{"key":31,"text":430,"correct":22},"500",{"id":432,"libraryId":5,"type":15,"typeLabel":16,"stem":433,"options":434,"answer":31,"analysis":33},1266451,"母线槽每段母线绝缘电阻经测试合格后才能安装组对，绝缘电阻值不小于（ ）M?。",[435,436,437,438],{"key":20,"text":347,"correct":26},{"key":24,"text":159,"correct":26},{"key":28,"text":77,"correct":26},{"key":31,"text":203,"correct":22},{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":28,"analysis":33},1266452,"建筑物室内部配电线路的配电形式有暗配线路和明配线路两种。导线沿墙壁、顶棚、桁架及梁柱等布线为明配敷设；导线埋设在墙内、空心板内、地坪内和布设在顶棚内等布线方式为暗配敷设。室内配线不仅要求安全可靠，满足使用功能，而且要求布局合理、整齐、牢固。请回答下列问题： 明配薄壁金属电线管管线之间的连接以及管与盒、箱等的连接均采用（ ）连接。",[443,445,447,448],{"key":20,"text":444,"correct":26},"焊接",{"key":24,"text":446,"correct":26},"法兰",{"key":28,"text":250,"correct":22},{"key":31,"text":449,"correct":26},"承插",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":28,"analysis":33},1266453,"配电间隔和静止补偿装置栅栏门应采用裸编织铜线与保护导体可靠连接，其截面积不应小于（ ）m㎡。",[454,455,456,457],{"key":20,"text":63,"correct":26},{"key":24,"text":65,"correct":26},{"key":28,"text":67,"correct":22},{"key":31,"text":69,"correct":26},{"id":459,"libraryId":5,"type":15,"typeLabel":16,"stem":460,"options":461,"answer":31,"analysis":33},1266454,"当采用多相供电时，同一建（构）筑物的绝缘导线绝缘层颜色选择应一致，即保护接地导体（P E）应是黄一绿双色组合色，中性导体（N）用（ ）。",[462,464,466,468],{"key":20,"text":463,"correct":26},"黄色",{"key":24,"text":465,"correct":26},"浅绿色",{"key":28,"text":467,"correct":26},"红色",{"key":31,"text":469,"correct":22},"淡蓝色",{"id":471,"libraryId":5,"type":15,"typeLabel":16,"stem":472,"options":473,"answer":20,"analysis":33},1266455,"插接式母线安装完成后，测量母线相间或相对地、相对零绝缘电阻大于等于（ ）兆欧时，方可送电。",[474,475,476,477],{"key":20,"text":347,"correct":22},{"key":24,"text":157,"correct":26},{"key":28,"text":159,"correct":26},{"key":31,"text":67,"correct":26},{"id":479,"libraryId":5,"type":15,"typeLabel":16,"stem":480,"options":481,"answer":24,"analysis":33},1266456,"低压成套配电柜、箱及控制柜（台、箱）间线路的线间和线对地间绝缘电阻值，馈电线路不应小于（ ） （C），二次回路不应小于（ ）M?。",[482,484,486,488],{"key":20,"text":483,"correct":26},"0.50.5",{"key":24,"text":485,"correct":22},"0.51",{"key":28,"text":487,"correct":26},"11",{"key":31,"text":79,"correct":26},{"id":490,"libraryId":5,"type":15,"typeLabel":16,"stem":491,"options":492,"answer":24,"analysis":33},1266457,"防雷装置的接地装置所用的材料的最小尺寸有要求，比如采用圆钢时，其最小直径为（ ）mm。",[493,494,495,496],{"key":20,"text":102,"correct":26},{"key":24,"text":77,"correct":22},{"key":28,"text":201,"correct":26},{"key":31,"text":203,"correct":26},{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":28,"analysis":33},1266458,"下列（ ）不符合照明配电箱（盘）安装的相关规定。",[501,503,505,507],{"key":20,"text":502,"correct":26},"箱（盘）内配线应整齐、无绞接现象",{"key":24,"text":504,"correct":26},"箱（盘）内导线连接应紧密、不伤线芯、不断股",{"key":28,"text":506,"correct":22},"箱（盘）内同一电器器件端子上的导线连接不应多于3根",{"key":31,"text":508,"correct":26},"箱（盘）内栓接端子，防松垫圈等零件应齐全，垫圈下螺丝两侧压的导线截面积应相同",{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":31,"analysis":33},1266459,"除采用安全电压以外，当设计无要求时，一般敞开式灯具，灯头对地面距离应大于（ ）m。",[513,514,515,516],{"key":20,"text":157,"correct":26},{"key":24,"text":63,"correct":26},{"key":28,"text":159,"correct":26},{"key":31,"text":65,"correct":22},{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":20,"analysis":33},1266460,"变压器安装就位且高低压开关柜安装完成后，应进行（ ）的连接，将变压器的高压侧与高压开关柜的出线侧连接，低压侧与低压开关柜的进线侧连接。",[521,523,525,527],{"key":20,"text":522,"correct":22},"一次线",{"key":24,"text":524,"correct":26},"二次线",{"key":28,"text":526,"correct":26},"接地线",{"key":31,"text":528,"correct":26},"零线",{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":531,"options":532,"answer":20,"analysis":33},1266461,"电气布线系统中钢管按厚度（ ）mm，分为厚壁钢管和薄壁钢管。",[533,534,535,536],{"key":20,"text":159,"correct":22},{"key":24,"text":99,"correct":26},{"key":28,"text":67,"correct":26},{"key":31,"text":102,"correct":26},{"id":538,"libraryId":5,"type":15,"typeLabel":16,"stem":539,"options":540,"answer":20,"analysis":33},1266462,"交流电动机带负荷启动时，一般在冷态时，可连续启动（ ）次；在热态时，可连续启动（ ）次。",[541,543,545,547],{"key":20,"text":542,"correct":22},"两一",{"key":24,"text":544,"correct":26},"一两",{"key":28,"text":546,"correct":26},"两三",{"key":31,"text":548,"correct":26},"三四",[550,553,556,559,562,565],{"id":15,"name":551,"category":7,"favorite":552},"领导干部任职前廉政法规知识测试题",92,{"id":554,"name":555,"category":7,"favorite":15},595,"建筑结构与设备",{"id":557,"name":558,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":560,"name":561,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":563,"name":564,"category":7,"favorite":8},534,"BIM工程师",{"id":566,"name":564,"category":7,"favorite":8},535]