[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-854-3":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":584},{"id":5,"name":6,"category":7,"favorite":8},854,"(设备安装质量)专业管理实务 岗位知识","建筑工程",0,3,50,1024,[13,34,46,58,70,81,93,105,117,127,139,151,163,175,187,199,211,223,235,247,259,271,282,292,304,314,326,338,349,361,373,384,396,408,420,432,443,452,464,472,481,492,503,514,522,534,542,550,560,572],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},1266363,1,"单选题","下列不属于室外给水管道安装施工机具的有（ ）。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","砂轮锯",false,{"key":24,"text":25,"correct":22},"B","电焊机",{"key":27,"text":28,"correct":29},"C","钢锯",true,{"key":31,"text":32,"correct":22},"D","试压泵","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},1266364,"下面不属于常用的金属管材的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"无缝钢管",{"key":24,"text":41,"correct":29},"PVC管",{"key":27,"text":43,"correct":22},"焊接钢管",{"key":31,"text":45,"correct":22},"铜管",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":27,"analysis":33},1266365,"在室内排水管道安装过程中，当安装高度超过（ ）米时，应搭好架子。",[50,52,54,56],{"key":20,"text":51,"correct":22},"2.5",{"key":24,"text":53,"correct":22},"3",{"key":27,"text":55,"correct":29},"3.5",{"key":31,"text":57,"correct":22},"4",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},1266366,"热水供应系统安装完毕，在管道保温前应进行水压试验。当设计未注明试验压力时，试验压力应为系统顶点的工作压力加0.IMPa，同时在系统顶点的试验压力不小于（ ）MPa。",[62,64,66,68],{"key":20,"text":63,"correct":29},"1.0",{"key":24,"text":65,"correct":22},"0.3",{"key":27,"text":67,"correct":22},"0.6",{"key":31,"text":69,"correct":22},"0.2",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":31,"analysis":33},1266367,"架空敷设的供热管道安装高度，如设计无规定时，在人行地区，不小于（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"2.0",{"key":24,"text":77,"correct":22},"4.5",{"key":27,"text":79,"correct":22},"3.0",{"key":31,"text":51,"correct":29},{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":20,"analysis":33},1266368,"雨水斗管的连接应固定在屋面承重结构上。雨水斗边缘与屋面相连处应严密不漏。与雨水斗连接的连接管管径，在设计无要求的情况下不得小于（ ）mm。",[85,87,89,91],{"key":20,"text":86,"correct":29},"100",{"key":24,"text":88,"correct":22},"110",{"key":27,"text":90,"correct":22},"150",{"key":31,"text":92,"correct":22},"160",{"id":94,"libraryId":5,"type":15,"typeLabel":16,"stem":95,"options":96,"answer":24,"analysis":33},1266369,"同种材料的PP～R管及管配件之间，应采用（ ）连接，安装应使用专用的工具。",[97,99,101,103],{"key":20,"text":98,"correct":22},"焊接",{"key":24,"text":100,"correct":29},"热熔",{"key":27,"text":102,"correct":22},"法兰",{"key":31,"text":104,"correct":22},"粘接",{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":107,"options":108,"answer":20,"analysis":33},1266370,"安装压力表必须符合下列规定：（1）压力表必须安装在便于观察和吹洗的位置，并防止受高温、冰冻和振动的影响，同时要有足够的照明。（2）压力表必须设有存水弯管。存水弯管采用钢管煨制时，内径不应小于10mm，采用铜管煨制时，内径不应小于6mm。（3）压力表与存水弯管之间应安装（ ）。",[109,111,113,115],{"key":20,"text":110,"correct":29},"三通旋塞",{"key":24,"text":112,"correct":22},"三通阀门",{"key":27,"text":114,"correct":22},"闸阀",{"key":31,"text":116,"correct":22},"截止阀",{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":119,"options":120,"answer":24,"analysis":33},1266371,"管道小于或等于100mm的镀锌钢管应采用（ ）连接，破坏的镀锌层表面应作防腐处理。",[121,122,124,125],{"key":20,"text":98,"correct":22},{"key":24,"text":123,"correct":29},"螺纹",{"key":27,"text":102,"correct":22},{"key":31,"text":126,"correct":22},"抱箍",{"id":128,"libraryId":5,"type":15,"typeLabel":16,"stem":129,"options":130,"answer":27,"analysis":33},1266372,"室外供热管道冲洗完毕应通水、加热，进行（ ）和调试。当不具备加热条件时，应延期进行。",[131,133,135,137],{"key":20,"text":132,"correct":22},"消毒",{"key":24,"text":134,"correct":22},"试压",{"key":27,"text":136,"correct":29},"试运行",{"key":31,"text":138,"correct":22},"冲洗",{"id":140,"libraryId":5,"type":15,"typeLabel":16,"stem":141,"options":142,"answer":20,"analysis":33},1266373,"给水系统可分为直接饮水形式、（ ）、水泵给水形式和水池、水泵和水箱联合给水形式。",[143,145,147,149],{"key":20,"text":144,"correct":29},"附水箱供水形式",{"key":24,"text":146,"correct":22},"间接引水系统",{"key":27,"text":148,"correct":22},"分流制",{"key":31,"text":150,"correct":22},"合流制",{"id":152,"libraryId":5,"type":15,"typeLabel":16,"stem":153,"options":154,"answer":27,"analysis":33},1266374,"增压设备和水箱安装的工艺流程，正确的是（ ）。",[155,157,159,161],{"key":20,"text":156,"correct":22},"安装准备→基础验收→吊装就位→设备开箱检查→找平找正→配管安装→试运转",{"key":24,"text":158,"correct":22},"安装准备→基础验收→设备开箱检查→找平找正→吊装就位→配管安装→试运转",{"key":27,"text":160,"correct":29},"安装准备→基础验收→设备开箱检查→吊装就位→找平找正→配管安装→试运转",{"key":31,"text":162,"correct":22},"安装准备→基础验收→设备开箱检查→吊装就位→配管安装→找平找正→试运转",{"id":164,"libraryId":5,"type":15,"typeLabel":16,"stem":165,"options":166,"answer":24,"analysis":33},1266375,"在混凝土排水管安装施工过程中，管顶（ ）cm范围以内，应采用人工夯填。",[167,169,171,173],{"key":20,"text":168,"correct":22},"40",{"key":24,"text":170,"correct":29},"50",{"key":27,"text":172,"correct":22},"60",{"key":31,"text":174,"correct":22},"70",{"id":176,"libraryId":5,"type":15,"typeLabel":16,"stem":177,"options":178,"answer":27,"analysis":33},1266376,"直埋管道的保温应符合设计要求，接口在现场发泡时，接头处厚度应与管道保温层厚度一致，接头处保护层必须与管道保护层成一体，符合（ ）要求。",[179,181,183,185],{"key":20,"text":180,"correct":22},"节能",{"key":24,"text":182,"correct":22},"防腐",{"key":27,"text":184,"correct":29},"防潮防水",{"key":31,"text":186,"correct":22},"保温",{"id":188,"libraryId":5,"type":15,"typeLabel":16,"stem":189,"options":190,"answer":20,"analysis":33},1266377,"室外排水管道埋设前必须做灌水试验和（ ），排水应畅通，无堵塞，管接口无渗漏。",[191,193,195,197],{"key":20,"text":192,"correct":29},"通水试验",{"key":24,"text":194,"correct":22},"渗水试验",{"key":27,"text":196,"correct":22},"严密性试验",{"key":31,"text":198,"correct":22},"强度试验",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":20,"analysis":33},1266378,"卫生器具安装正确的工艺流程是（ ）。",[203,205,207,209],{"key":20,"text":204,"correct":29},"安装准备→卫生器具及配件检验→卫生器具安装→卫生器具配件预装→卫生器具稳装→卫生器具与墙、地缝隙处理→卫生器具外观检查→通水试验",{"key":24,"text":206,"correct":22},"安装准备→卫生器具及配件检验→卫生器具安装→卫生器具配件稳装→卫生器具预装→卫生器具与墙、地缝隙处理→卫生器具外观检查→通水试验",{"key":27,"text":208,"correct":22},"安装准备→卫生器具及配件检验→卫生器具稳装→卫生器具配件预装→卫生器具安装→卫生器具与墙、地缝隙处理→卫生器具外观检查→通水试验",{"key":31,"text":210,"correct":22},"安装准备→卫生器具及配件检验→卫生器具稳装→卫生器具配件安装→卫生器具预装→卫生器具与墙、地缝隙处理→卫生器具外观检查→通水试验",{"id":212,"libraryId":5,"type":15,"typeLabel":16,"stem":213,"options":214,"answer":31,"analysis":33},1266379,"减压板安装的部位应是在较长的直管段上，且其前面的长度不小于（ ）倍管径。",[215,217,219,221],{"key":20,"text":216,"correct":22},"2",{"key":24,"text":218,"correct":22},"5",{"key":27,"text":220,"correct":22},"8",{"key":31,"text":222,"correct":29},"10",{"id":224,"libraryId":5,"type":15,"typeLabel":16,"stem":225,"options":226,"answer":24,"analysis":33},1266380,"室内给水管道的水压试验必须符合设计要求。当设计未注明时，应按（ ）的标准进行水压试验。",[227,229,231,233],{"key":20,"text":228,"correct":22},"系统工作压力的1.15倍，但不得小于0.6MPa",{"key":24,"text":230,"correct":29},"系统工作压力的1.5倍，但不得小于0.6MPa",{"key":27,"text":232,"correct":22},"系统工作压力的1.5倍，但不得小于1.4MPa",{"key":31,"text":234,"correct":22},"系统工作压力的1.1倍，但不得小于1.4MPa",{"id":236,"libraryId":5,"type":15,"typeLabel":16,"stem":237,"options":238,"answer":31,"analysis":33},1266381,"排水通气管不得与（ ）连接。",[239,241,243,245],{"key":20,"text":240,"correct":22},"污水管",{"key":24,"text":242,"correct":22},"风道",{"key":27,"text":244,"correct":22},"烟道",{"key":31,"text":246,"correct":29},"风道或烟道",{"id":248,"libraryId":5,"type":15,"typeLabel":16,"stem":249,"options":250,"answer":24,"analysis":33},1266382,"室内给水系统安装的工艺流程正确顺序是（ ）",[251,253,255,257],{"key":20,"text":252,"correct":22},"孔洞预留、埋件→支管安装→立管安装→干管安装→水压试验→管道防腐和保温→管道冲洗→通水试验",{"key":24,"text":254,"correct":29},"孔洞预留、埋件→干管安装→立管安装→支管安装→水压试验→管道防腐和保温→管道冲洗→通水试验",{"key":27,"text":256,"correct":22},"孔洞预留、埋件→支管安装→立管安装→干管安装→管道防腐和保温→水压试验→管道冲洗→通水试验",{"key":31,"text":258,"correct":22},"孔洞预留、埋件→干管安装→立管安装→支管安装→管道防腐和保温→水压试验→管道冲洗→通水试验",{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":20,"analysis":33},1266383,"中水管道不宜暗装于（ ），如必须暗装于墙槽内时，必须在管道上有明显且不会脱落的标志。",[263,265,267,269],{"key":20,"text":264,"correct":29},"墙体和楼板内",{"key":24,"text":266,"correct":22},"墙体内",{"key":27,"text":268,"correct":22},"楼板内",{"key":31,"text":270,"correct":22},"墙槽内",{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":20,"analysis":33},1266384,"室内采暖系统冲洗完毕应充水、加热，进行试运行和（ ）。",[275,277,278,280],{"key":20,"text":276,"correct":29},"调试",{"key":24,"text":134,"correct":22},{"key":27,"text":279,"correct":22},"清洗",{"key":31,"text":281,"correct":22},"验收",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":27,"analysis":33},1266385,"对于一般建筑，消火栓应做试射试验，其充实水柱高度高度为（ ）m。",[286,287,289,291],{"key":20,"text":218,"correct":22},{"key":24,"text":288,"correct":22},"6",{"key":27,"text":290,"correct":29},"7",{"key":31,"text":222,"correct":22},{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":31,"analysis":33},1266386,"排水主立管及水平干管管道均应做通球试验，通球球径不小于排水管道管径的2\u002F3，而且通球率必须达到（ ）",[296,298,300,302],{"key":20,"text":297,"correct":22},"50%",{"key":24,"text":299,"correct":22},"60%",{"key":27,"text":301,"correct":22},"80%",{"key":31,"text":303,"correct":29},"100%",{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":24,"analysis":33},1266387,"管径为110mm塑料排水管垂直安装时，其支架最大间距应为（ ）m。",[308,309,310,312],{"key":20,"text":57,"correct":22},{"key":24,"text":216,"correct":29},{"key":27,"text":311,"correct":22},"1.1",{"key":31,"text":313,"correct":22},"1.5",{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":31,"analysis":33},1266388,"室内直埋给水管道（塑料管道和复合管道除外）应做防腐处理。埋地管道防腐层（ ）应符合设计要求。",[318,320,322,324],{"key":20,"text":319,"correct":22},"材质和厚度",{"key":24,"text":321,"correct":22},"质量和结构",{"key":27,"text":323,"correct":22},"质量和施工",{"key":31,"text":325,"correct":29},"材质和结构",{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":24,"analysis":33},1266389,"下列叙述中错误的是（ ）。",[330,332,334,336],{"key":20,"text":331,"correct":22},"设备安装位置可以用三视图表达",{"key":24,"text":333,"correct":29},"给排水管道的简化方法不能用在三视图中",{"key":27,"text":335,"correct":22},"给水排水工程图绘画中有单线法和双线法",{"key":31,"text":337,"correct":22},"给水排水工程、通风与空调工程好、消防工程三类工程的施工图的表达形式上有共同点",{"id":339,"libraryId":5,"type":15,"typeLabel":16,"stem":340,"options":341,"answer":27,"analysis":33},1266390,"某行政办公楼2012年3月主体工程施工完毕，开始进行给水排水管道安装施工，承包单位合理安排施工，严格把好质量关，2012年7月底工程顺利通过竣工验收并投入使用，请问管道施工时应注意哪些问题。 对于生活、生产、消防合用的给水系统，如果只有一条引入管时，应绕开（ ）安装旁通管。",[342,343,345,347],{"key":20,"text":114,"correct":22},{"key":24,"text":344,"correct":22},"止回阀",{"key":27,"text":346,"correct":29},"水表",{"key":31,"text":348,"correct":22},"调节阀",{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":31,"analysis":33},1266391,"下面不属于室外排水管道安装的作业条件的是（ ）。",[353,355,357,359],{"key":20,"text":354,"correct":22},"管沟平直、管沟深度、宽度符合要求",{"key":24,"text":356,"correct":22},"管沟沟底夯实，沟内无障碍物",{"key":27,"text":358,"correct":22},"管沟两侧不得堆放施工材料和其他物品",{"key":31,"text":360,"correct":29},"因为是室外排水管，所以即使是雨季施工，也无需考虑防雨",{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":20,"analysis":33},1266392,"由室内通向室外排水检查井的排水管，井内引人管应（ ）排出管或两管顶相平，并有不小于90。的水流转角，如跌落差大于300mm可不受角度限制。",[365,367,369,371],{"key":20,"text":366,"correct":29},"高于",{"key":24,"text":368,"correct":22},"低于",{"key":27,"text":370,"correct":22},"略低于",{"key":31,"text":372,"correct":22},"相平",{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":20,"analysis":33},1266393,"湿式报警阀调试时，在试水装置处放水，当湿式报警阀进口水压大于0.14MPa放水流量大于IL\u002Fs时，报警阀应及时启动；带延迟器的水力警铃应在5~90S内发出报警铃声，不带延迟器的水力警铃应在（ ）s内发出报警铃声；压力开关应及时动作，并反馈信号。",[377,379,381,382],{"key":20,"text":378,"correct":29},"15",{"key":24,"text":380,"correct":22},"30",{"key":27,"text":222,"correct":22},{"key":31,"text":383,"correct":22},"20",{"id":385,"libraryId":5,"type":15,"typeLabel":16,"stem":386,"options":387,"answer":31,"analysis":33},1266394,"自动喷水灭火系统水压强度试验的测试点应设在系统管网的最低点。对管网注水时，应将管网内的空气排净，并应缓慢升压；达到试验压力后，稳压30min后，管网应无泄漏、无变形，且压力降不应大于（ ）MPa。",[388,390,392,394],{"key":20,"text":389,"correct":22},"0.02",{"key":24,"text":391,"correct":22},"0.03",{"key":27,"text":393,"correct":22},"0.04",{"key":31,"text":395,"correct":29},"0.05",{"id":397,"libraryId":5,"type":15,"typeLabel":16,"stem":398,"options":399,"answer":20,"analysis":33},1266395,"下列不属于按洒水形式及使用方法来分类闭式洒水喷头的是（ ）。",[400,402,404,406],{"key":20,"text":401,"correct":29},"倒立型",{"key":24,"text":403,"correct":22},"直立型",{"key":27,"text":405,"correct":22},"下垂型",{"key":31,"text":407,"correct":22},"边墙型",{"id":409,"libraryId":5,"type":15,"typeLabel":16,"stem":410,"options":411,"answer":27,"analysis":33},1266396,"机械三通连接时，应检查机械三通与孔洞的间隙，各部位应均匀，然后再紧固到位；机械二通开孔间距不应小于500mm，机械四通开孔间距不应小于（ ）mm。",[412,414,416,418],{"key":20,"text":413,"correct":22},"600",{"key":24,"text":415,"correct":22},"800",{"key":27,"text":417,"correct":29},"1000",{"key":31,"text":419,"correct":22},"1200",{"id":421,"libraryId":5,"type":15,"typeLabel":16,"stem":422,"options":423,"answer":27,"analysis":33},1266397,"正压送风系统的正确启动顺序是（ ）。",[424,426,428,430],{"key":20,"text":425,"correct":22},"火灾探测器或手动报警信号报警→正压送风机启动→正压送风口打开",{"key":24,"text":427,"correct":22},"正压送风机启动→火灾探测器或手动报警信号报警→正压送风口打开",{"key":27,"text":429,"correct":29},"火灾探测器或手动报警信号报警→正压送风口打开→正压送风机启动",{"key":31,"text":431,"correct":22},"正压送风口打开→正压送风机启动→火灾探测器或手动报警信号报警",{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":434,"options":435,"answer":20,"analysis":33},1266398,"当喷头的公称直径小于（ ）mm时，应在配水干管或配水管上安装过滤器。",[436,437,439,441],{"key":20,"text":222,"correct":29},{"key":24,"text":438,"correct":22},"12",{"key":27,"text":440,"correct":22},"14",{"key":31,"text":442,"correct":22},"16",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":24,"analysis":33},1266399,"当梁、通风管道、排管、桥架宽度大于（ ）m时，自动喷水灭火系统增设的喷头应安装在其腹面以下部位。",[447,448,450,451],{"key":20,"text":63,"correct":22},{"key":24,"text":449,"correct":29},"1.2",{"key":27,"text":313,"correct":22},{"key":31,"text":75,"correct":22},{"id":453,"libraryId":5,"type":15,"typeLabel":16,"stem":454,"options":455,"answer":20,"analysis":33},1266400,"镀锌钢管应为内外壁热镀锌钢管，钢管内外表面的镀锌层不得有脱落、锈蚀等现象；钢管的内、外径应符合现行国家标准《低压流体输送用焊接钢管》（ ）或现行国家标准《输送流体用无缝钢管》GB\u002FT8163的规定。",[456,458,460,462],{"key":20,"text":457,"correct":29},"GB\u002FT3091",{"key":24,"text":459,"correct":22},"GB\u002FT13793",{"key":27,"text":461,"correct":22},"GB\u002FT13663",{"key":31,"text":463,"correct":22},"GB\u002FT1527",{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":31,"analysis":33},1266401,"自动喷水灭火系统报警阀应进行渗漏试验。试验压力应为额定工作压力的1.5倍，保压时间不应少于（ ）min。阀瓣处应无渗漏。",[468,469,470,471],{"key":20,"text":222,"correct":22},{"key":24,"text":216,"correct":22},{"key":27,"text":53,"correct":22},{"key":31,"text":218,"correct":29},{"id":473,"libraryId":5,"type":15,"typeLabel":16,"stem":474,"options":475,"answer":24,"analysis":33},1266402,"消防水泵调试应符合下列要求：（1）以自动或手动方式启动消防水泵时，消防水泵应在30S内投人正常运行；（2）以备用电源切换方式或备用泵切换启动消防水泵时，消防水泵应在（ ）s内投人正常运行。",[476,478,479,480],{"key":20,"text":477,"correct":22},"35",{"key":24,"text":380,"correct":29},{"key":27,"text":170,"correct":22},{"key":31,"text":383,"correct":22},{"id":482,"libraryId":5,"type":15,"typeLabel":16,"stem":483,"options":484,"answer":31,"analysis":33},1266403,"排烟支管上应设有当烟气温度超过（ ）℃时，能自动关闭的防火阀。",[485,486,488,490],{"key":20,"text":90,"correct":22},{"key":24,"text":487,"correct":22},"200",{"key":27,"text":489,"correct":22},"250",{"key":31,"text":491,"correct":29},"280",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":27,"analysis":33},1266404,"配水支管上每一直管段、相邻两喷头之间的管段设置的吊架均不宜少于1个，吊架的间距不宜大于（ ）。",[496,498,499,501],{"key":20,"text":497,"correct":22},"1",{"key":24,"text":216,"correct":22},{"key":27,"text":500,"correct":29},"3.6",{"key":31,"text":502,"correct":22},"2.6",{"id":504,"libraryId":5,"type":15,"typeLabel":16,"stem":505,"options":506,"answer":27,"analysis":33},1266405,"自动喷水灭火系统墙壁消防水泵结合器安装位置应符合设计及规范要求，设计无要求时，其安装高度距地面宜为（ ）。",[507,509,511,513],{"key":20,"text":508,"correct":22},"0.4",{"key":24,"text":510,"correct":22},"0.5",{"key":27,"text":512,"correct":29},"0.7",{"key":31,"text":63,"correct":22},{"id":515,"libraryId":5,"type":15,"typeLabel":16,"stem":516,"options":517,"answer":24,"analysis":33},1266406,"水力警铃和报警阀的连接应采用热镀锌钢管，当镀锌钢管的公称直径为20mm时，一长度不宜大于（ ）m安装后的水力警铃启动时，警铃声强度应不小于70dB。",[518,519,520,521],{"key":20,"text":222,"correct":22},{"key":24,"text":383,"correct":29},{"key":27,"text":378,"correct":22},{"key":31,"text":380,"correct":22},{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":24,"analysis":33},1266407,"水压严密性试验应在水压强度试验和管网冲洗合格后进行。试验压力为（ ），稳压（ ）h，应无泄露才可以。",[526,528,530,532],{"key":20,"text":527,"correct":22},"设计工作压力12",{"key":24,"text":529,"correct":29},"设计工作压力24",{"key":27,"text":531,"correct":22},"实际工作压力12",{"key":31,"text":533,"correct":22},"实际工作压力24",{"id":535,"libraryId":5,"type":15,"typeLabel":16,"stem":536,"options":537,"answer":27,"analysis":33},1266408,"湿式自动喷水灭火系统的喷头安装中，当喷头DN＜（ ）mm时，应在干管或配水管上安装过滤器。",[538,539,540,541],{"key":20,"text":218,"correct":22},{"key":24,"text":220,"correct":22},{"key":27,"text":222,"correct":29},{"key":31,"text":438,"correct":22},{"id":543,"libraryId":5,"type":15,"typeLabel":16,"stem":544,"options":545,"answer":20,"analysis":33},1266409,"配水干管、配水管应做红色或红色环圈标志。红色环圈标志，宽度不应小于20mm，间隔不宜大于（ ）m，在一个独立的单元内环圈不宜少于2处。",[546,547,548,549],{"key":20,"text":57,"correct":29},{"key":24,"text":216,"correct":22},{"key":27,"text":53,"correct":22},{"key":31,"text":288,"correct":22},{"id":551,"libraryId":5,"type":15,"typeLabel":16,"stem":552,"options":553,"answer":27,"analysis":33},1266410,"气压严密性试验压力应为（ ）MPa，且稳压24唇，压力降不应大于0.01MPa。",[554,555,557,559],{"key":20,"text":65,"correct":22},{"key":24,"text":556,"correct":22},"0.38",{"key":27,"text":558,"correct":29},"0.28",{"key":31,"text":67,"correct":22},{"id":561,"libraryId":5,"type":15,"typeLabel":16,"stem":562,"options":563,"answer":27,"analysis":33},1266411,"发生火灾事故时，在死亡的绝大多数人是因为（ ）。",[564,566,568,570],{"key":20,"text":565,"correct":22},"大火烧死",{"key":24,"text":567,"correct":22},"跳楼而死",{"key":27,"text":569,"correct":29},"吸入毒性气体而死",{"key":31,"text":571,"correct":22},"因人群踩踏而死",{"id":573,"libraryId":5,"type":15,"typeLabel":16,"stem":574,"options":575,"answer":20,"analysis":33},1266412,"水泵吸水管水平管段上不应有气囊和漏气现象。变径连接时，应采用偏心异径管件并应采用（ ）。",[576,578,580,582],{"key":20,"text":577,"correct":29},"管顶平接",{"key":24,"text":579,"correct":22},"管底平接",{"key":27,"text":581,"correct":22},"顶平偏心",{"key":31,"text":583,"correct":22},"底平偏心",[585,588,591,594,597,600],{"id":15,"name":586,"category":7,"favorite":587},"领导干部任职前廉政法规知识测试题",92,{"id":589,"name":590,"category":7,"favorite":15},595,"建筑结构与设备",{"id":592,"name":593,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":595,"name":596,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":598,"name":599,"category":7,"favorite":8},534,"BIM工程师",{"id":601,"name":599,"category":7,"favorite":8},535]