[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-854-12":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":728},{"id":5,"name":6,"category":7,"favorite":8},854,"(设备安装质量)专业管理实务 岗位知识","建筑工程",0,12,50,1024,[13,38,53,68,83,98,112,126,140,155,169,182,196,210,225,239,253,267,281,296,311,325,340,354,365,379,393,407,422,436,450,465,479,494,508,517,532,546,560,574,588,601,615,629,643,657,671,685,699,713],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},1266814,2,"多选题","接闪器与防雷引下线之间的连接方式为（ ）。",[19,23,27,30,33],{"key":20,"text":21,"correct":22},"A","螺栓连接",false,{"key":24,"text":25,"correct":26},"B","焊接",true,{"key":28,"text":29,"correct":22},"C","搭接",{"key":31,"text":32,"correct":26},"D","卡接器连接",{"key":34,"text":35,"correct":22},"E","机械连接","BD","",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":52,"analysis":37},1266815,"下面关于自然接地体的叙述，正确的有（ ）",[42,44,46,48,50],{"key":20,"text":43,"correct":26},"目前在施工中，经常选用的是自然接地体",{"key":24,"text":45,"correct":26},"选用自然接地体时，必须保证导体全长有可靠的电气连接",{"key":28,"text":47,"correct":22},"同时应保证有3根以上导体在不同地点与接地干线连接",{"key":31,"text":49,"correct":26},"选用自然接地体，可以降低工程成本",{"key":34,"text":51,"correct":22},"同时应保证有1根以上导体在不同地点与接地干线连接","ABD",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":67,"analysis":37},1266816,"对开关、插座、接线盒及面板等绝缘材料的（ ）有异议时，应按批抽样送有资质的试验室检测。",[57,59,61,63,65],{"key":20,"text":58,"correct":22},"耐撞击性能",{"key":24,"text":60,"correct":26},"耐非正常热",{"key":28,"text":62,"correct":26},"耐燃",{"key":31,"text":64,"correct":26},"耐漏电起痕性能",{"key":34,"text":66,"correct":22},"节能性能","BCD",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":82,"analysis":37},1266817,"接闪线和接闪带安装应符合（ ）要求。",[72,74,76,78,80],{"key":20,"text":73,"correct":26},"平正顺直",{"key":24,"text":75,"correct":26},"无急弯",{"key":28,"text":77,"correct":26},"支架间距均匀",{"key":31,"text":79,"correct":26},"固定牢固",{"key":34,"text":81,"correct":22},"标高相同","ABCD",{"id":84,"libraryId":5,"type":15,"typeLabel":16,"stem":85,"options":86,"answer":97,"analysis":37},1266818,"实行生产许可证或CCC认证的产品，应有许可证编号或CCC认证标志，进场验收时应抽查生产许可证或CCC认证证书的（ ）。",[87,89,91,93,95],{"key":20,"text":88,"correct":26},"认证范围",{"key":24,"text":90,"correct":26},"有效性",{"key":28,"text":92,"correct":26},"真实性",{"key":31,"text":94,"correct":22},"可靠性",{"key":34,"text":96,"correct":22},"权威性","ABC",{"id":99,"libraryId":5,"type":15,"typeLabel":16,"stem":100,"options":101,"answer":82,"analysis":37},1266819,"在电气工程中，主要（ ）进场验收应有记录，确认符合设计要求和本规范规定，才能在施工中应用。当设计有技术参数要求时，应核对其技术参数符合设计要求。",[102,104,106,108,110],{"key":20,"text":103,"correct":26},"设备",{"key":24,"text":105,"correct":26},"材料",{"key":28,"text":107,"correct":26},"成品",{"key":31,"text":109,"correct":26},"半成品",{"key":34,"text":111,"correct":22},"文件",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":52,"analysis":37},1266820,"下面关于支吊架安装的叙述，正确的是（ ）。",[116,118,120,122,124],{"key":20,"text":117,"correct":26},"支吊架安装前根据设计图确定走向、进户线、盒、箱等电气器具的安装位置",{"key":24,"text":119,"correct":26},"支吊架焊接连接后，应及时清楚焊渣",{"key":28,"text":121,"correct":22},"支吊架可以不进行防腐处理",{"key":31,"text":123,"correct":26},"支吊架采用膨胀螺栓固定时，应根据支吊架承重的负荷选择相应的金属膨胀螺栓",{"key":34,"text":125,"correct":22},"支吊架焊接连接后，不需做防腐处理。",{"id":127,"libraryId":5,"type":15,"typeLabel":16,"stem":128,"options":129,"answer":52,"analysis":37},1266821,"当验收建筑电气工程时，应核查各项质量控制资料，资料内容应（ ）。",[130,132,134,136,138],{"key":20,"text":131,"correct":26},"真实",{"key":24,"text":133,"correct":26},"齐全",{"key":28,"text":135,"correct":22},"及时",{"key":31,"text":137,"correct":26},"完整",{"key":34,"text":139,"correct":22},"装订成册",{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":154,"analysis":37},1266822,"电气设备、器具和材料的电压应按（ ）划分区段。",[144,146,148,150,152],{"key":20,"text":145,"correct":26},"额定电压区段：交流50V、直流120V及以下为特低压",{"key":24,"text":147,"correct":22},"额定电压区段：交流50V、1.0kV、直流120V、1.5kV为低压",{"key":28,"text":149,"correct":26},"额定电压区段：交流50V、1.0kV（含1.0kV）、直流120V、1.5kV（含1.5kV）为低压",{"key":31,"text":151,"correct":26},"额定电压区段：交流1.0kV、直流1.5kV以上为高压",{"key":34,"text":153,"correct":22},"额定电压区段：交流1.0MV、直流1.0MV以上为高压","ACD",{"id":156,"libraryId":5,"type":15,"typeLabel":16,"stem":157,"options":158,"answer":82,"analysis":37},1266823,"下列关于导管的描述正确的是（ ）。",[159,161,163,165,167],{"key":20,"text":160,"correct":26},"管子顺直无严重变形，壁厚均匀",{"key":24,"text":162,"correct":26},"镀锌管锌层完整，无剥落和锈斑",{"key":28,"text":164,"correct":26},"非镀锌管管子内外壁需先除锈刷防腐漆",{"key":31,"text":166,"correct":26},"防腐漆均匀完整无剥落现象",{"key":34,"text":168,"correct":22},"焊缝可以有少许裂缝、砂眼",{"id":170,"libraryId":5,"type":15,"typeLabel":16,"stem":171,"options":172,"answer":82,"analysis":37},1266824,"电缆敷设（ ）。",[173,175,177,179,181],{"key":20,"text":174,"correct":26},"应排列顺直",{"key":24,"text":176,"correct":26},"应排列整齐",{"key":28,"text":178,"correct":26},"宜少交叉",{"key":31,"text":180,"correct":26},"应按设计要求（设计无要求时，按规范要求）固定",{"key":34,"text":79,"correct":22},{"id":183,"libraryId":5,"type":15,"typeLabel":16,"stem":184,"options":185,"answer":52,"analysis":37},1266825,"防雷接地系统中的避雷针、网、带的连接一般采用搭接焊，其焊接长度应符合的要求，正确的是（ ）。",[186,188,190,192,194],{"key":20,"text":187,"correct":26},"扁钢为其宽度的2倍，三面施焊",{"key":24,"text":189,"correct":26},"圆钢为其长度的6倍，双面施焊",{"key":28,"text":191,"correct":22},"圆钢与扁钢连接时，其长度为圆钢直径的4倍",{"key":31,"text":193,"correct":26},"扁钢与钢管或扁钢与角钢焊接时，为了连接可靠，除应在其接触部位两侧进行焊接外，还应将钢带弯成弧形或直角形与钢管或角钢焊接",{"key":34,"text":195,"correct":22},"扁钢为其宽度的2倍，双面施焊",{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":154,"analysis":37},1266826,"建筑电气工程的构成可分为（ ）。",[200,202,204,206,208],{"key":20,"text":201,"correct":26},"电气装置",{"key":24,"text":203,"correct":22},"电动机系统",{"key":28,"text":205,"correct":26},"布线系统",{"key":31,"text":207,"correct":26},"用电设备（器具）电气部分",{"key":34,"text":209,"correct":22},"变压器设备",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":224,"analysis":37},1266827,"母线槽的金属外壳与外部保护导体连接完成，母线（ ）合格后，才能通电",[214,216,218,220,222],{"key":20,"text":215,"correct":26},"绝缘电阻测试",{"key":24,"text":217,"correct":22},"检查",{"key":28,"text":219,"correct":22},"验收",{"key":31,"text":221,"correct":26},"交流工频耐压试验",{"key":34,"text":223,"correct":22},"通电","AD",{"id":226,"libraryId":5,"type":15,"typeLabel":16,"stem":227,"options":228,"answer":97,"analysis":37},1266828,"除设计要求外，并联使用的电力电缆其（ ）应相同。",[229,231,233,235,237],{"key":20,"text":230,"correct":26},"型号",{"key":24,"text":232,"correct":26},"规格",{"key":28,"text":234,"correct":26},"厂家",{"key":31,"text":236,"correct":22},"电阻",{"key":34,"text":238,"correct":22},"长度",{"id":240,"libraryId":5,"type":15,"typeLabel":16,"stem":241,"options":242,"answer":154,"analysis":37},1266829,"按制造标准及设计要求现场应按批抽样检测导管的（ ）。",[243,245,247,249,251],{"key":20,"text":244,"correct":26},"管径",{"key":24,"text":246,"correct":22},"管长度",{"key":28,"text":248,"correct":26},"壁厚",{"key":31,"text":250,"correct":26},"均匀度",{"key":34,"text":252,"correct":22},"直线度",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":36,"analysis":37},1266830,"根据《建筑物防雷设计规范》GB50057-2010的有关规定，电子系统设备机房的等电位连接应根据电子系统的工作频率分别采用（ ）。",[257,259,261,263,265],{"key":20,"text":258,"correct":22},"N",{"key":24,"text":260,"correct":26},"M",{"key":28,"text":262,"correct":22},"H",{"key":31,"text":264,"correct":26},"S",{"key":34,"text":266,"correct":22},"K",{"id":268,"libraryId":5,"type":15,"typeLabel":16,"stem":269,"options":270,"answer":67,"analysis":37},1266831,"当SPD内部未设计热脱扣装置时，对失效状态为短路型的SP D，应在其前端安装（ ）进行后备过电流保护。",[271,273,275,277,279],{"key":20,"text":272,"correct":22},"开关",{"key":24,"text":274,"correct":26},"熔丝",{"key":28,"text":276,"correct":26},"热熔线圈",{"key":31,"text":278,"correct":26},"断路器",{"key":34,"text":280,"correct":22},"变压器",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":295,"analysis":37},1266832,"第三类防雷建筑物明敷接闪器的网络尺寸应不大于（ ）。",[285,287,289,291,293],{"key":20,"text":286,"correct":22},"10m×10m",{"key":24,"text":288,"correct":22},"8m×12m",{"key":28,"text":290,"correct":26},"20m×20m",{"key":31,"text":292,"correct":26},"16m×24m",{"key":34,"text":294,"correct":22},"25m×25m","CD",{"id":297,"libraryId":5,"type":15,"typeLabel":16,"stem":298,"options":299,"answer":310,"analysis":37},1266833,"冷热水、冷却水系统的试验压力，当工作压力小于等于1.0MPa时，为1.5倍工作压力，但最低不小于（ ）；当工作压力大于1.0MPa时，为工作压力加（ ）。",[300,302,304,306,308],{"key":20,"text":301,"correct":26},"0.5MPa",{"key":24,"text":303,"correct":22},"1.5MPa",{"key":28,"text":305,"correct":26},"0.6MPa",{"key":31,"text":307,"correct":22},"1.0MPa",{"key":34,"text":309,"correct":22},"0.2MPa","AC",{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":295,"analysis":37},1266834,"风机盘管机组安装前宜进行单机三速试运转及水压检漏试验。试验压力为系统工作压力的（ ）倍，试验观察时间为（ ）min，不渗漏为合格。",[315,317,319,321,323],{"key":20,"text":316,"correct":22},"1.1",{"key":24,"text":318,"correct":22},"5",{"key":28,"text":320,"correct":26},"2",{"key":31,"text":322,"correct":26},"1.5",{"key":34,"text":324,"correct":22},"3",{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":339,"analysis":37},1266835,"采用铝箔离心玻璃棉纤维板为保温材料的矩形风管及设备保温钉分布应均匀，其数量底面每平方米不应少于（ ）个，侧面不应少于（ ）个。顶面不应少于（ ）个，首行保温钉距风管或保温材料边沿的距离应小于120mm。",[329,331,333,335,337],{"key":20,"text":330,"correct":26},"16",{"key":24,"text":332,"correct":22},"6",{"key":28,"text":334,"correct":22},"12",{"key":31,"text":336,"correct":26},"10",{"key":34,"text":338,"correct":26},"8","ADE",{"id":341,"libraryId":5,"type":15,"typeLabel":16,"stem":342,"options":343,"answer":36,"analysis":37},1266836,"风管外径或外边长的允许偏差：当小于或等于300mm时，为（ ）；当大于300mm时，为3mm。管口平面度的允许偏差为2mm，矩形风管两条对角线长度之差不应大于（ ）；圆形法兰任意正交两直径之差不应大于2mm。",[344,346,348,350,352],{"key":20,"text":345,"correct":22},"1mm",{"key":24,"text":347,"correct":26},"3mm",{"key":28,"text":349,"correct":22},"4mm",{"key":31,"text":351,"correct":26},"2mm",{"key":34,"text":353,"correct":22},"0.5mm",{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":364,"analysis":37},1266837,"风管水平安装，直径或边长尺寸小于400mm，支架间距应不大于（ ）m；大于或等于400mm，应不大于（ ）m。",[358,360,361,362,363],{"key":20,"text":359,"correct":26},"4",{"key":24,"text":324,"correct":26},{"key":28,"text":318,"correct":22},{"key":31,"text":332,"correct":22},{"key":34,"text":320,"correct":22},"AB",{"id":366,"libraryId":5,"type":15,"typeLabel":16,"stem":367,"options":368,"answer":52,"analysis":37},1266838,"矩形风管边长大于或等于（ ）mm和保温风管边长大于或等于（ ）mm，且其管段长度大于（ ）mm时均应采取加固措施。",[369,371,373,375,377],{"key":20,"text":370,"correct":26},"630",{"key":24,"text":372,"correct":26},"800",{"key":28,"text":374,"correct":22},"1200",{"key":31,"text":376,"correct":26},"1250",{"key":34,"text":378,"correct":22},"500",{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":381,"options":382,"answer":82,"analysis":37},1266839,"柔性短管应选用（ ）的柔性材料。用于空调系统的应采取防止结露的措施；用于净化空调系统的还应是内壁光滑、不易产生尘埃的材料。",[383,385,387,389,391],{"key":20,"text":384,"correct":26},"防腐",{"key":24,"text":386,"correct":26},"防潮",{"key":28,"text":388,"correct":26},"不透气",{"key":31,"text":390,"correct":26},"不易霉变",{"key":34,"text":392,"correct":22},"不变形",{"id":394,"libraryId":5,"type":15,"typeLabel":16,"stem":395,"options":396,"answer":52,"analysis":37},1266840,"下面对空调水系统及设备安装的过程中，正确的说法是（ ）。",[397,399,401,403,405],{"key":20,"text":398,"correct":26},"管道与设备的连接应在设备安装完毕后进行",{"key":24,"text":400,"correct":26},"管道与风管、制冷机组的连接必须柔性连接",{"key":28,"text":402,"correct":22},"管道与风管、制冷机组的连接可以对口连接",{"key":31,"text":404,"correct":26},"与风管、制冷机组连接的管道应设置独立支架",{"key":34,"text":406,"correct":22},"管道与设备的连接与设备安装同时进行",{"id":408,"libraryId":5,"type":15,"typeLabel":16,"stem":409,"options":410,"answer":421,"analysis":37},1266841,"下列选项属于常用的金属风管的是（ ）。",[411,413,415,417,419],{"key":20,"text":412,"correct":26},"黑铁皮",{"key":24,"text":414,"correct":26},"白铁皮",{"key":28,"text":416,"correct":26},"铝板",{"key":31,"text":418,"correct":22},"玻璃钢板",{"key":34,"text":420,"correct":26},"不锈钢板","ABCE",{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":424,"options":425,"answer":82,"analysis":37},1266842,"下面对支、吊架制作用型钢的矫正，叙述正确的是（ ）。",[426,428,430,432,434],{"key":20,"text":427,"correct":26},"矫正的方法分为冷矫正和热矫正",{"key":24,"text":429,"correct":26},"小型钢材一般采用冷矫正",{"key":28,"text":431,"correct":26},"较大的型钢必须加热到900℃左右后进行热矫正",{"key":31,"text":433,"correct":26},"矫正的顺序应该先矫正扭曲、后矫正弯曲",{"key":34,"text":435,"correct":22},"矫正的顺序应该先矫正弯曲、后矫正扭曲",{"id":437,"libraryId":5,"type":15,"typeLabel":16,"stem":438,"options":439,"answer":67,"analysis":37},1266843,"下面关于洁净层流罩的安装要求，叙述正确的是（ ）。",[440,442,444,446,448],{"key":20,"text":441,"correct":22},"可以不设独立的吊杆，但要有防晃的固定措施",{"key":24,"text":443,"correct":26},"需设独立的吊杆，并有防晃的固定措施",{"key":28,"text":445,"correct":26},"层流罩安装的水平度允许偏差为1\u002F1000，高度的允许偏差为±1mm",{"key":31,"text":447,"correct":26},"层流罩安装在吊顶上，其四周与顶板之间应设有密封及隔振措施",{"key":34,"text":449,"correct":22},"层流罩安装的水平度允许偏差为1\u002F2000，高度的允许偏差为±5mm",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":464,"analysis":37},1266844,"闭式系统管路应在最高处及所有可能积聚空气的高点设置（ ），在管路最低点应设置（ ）及（ ）。",[454,456,458,460,462],{"key":20,"text":455,"correct":26},"排水管",{"key":24,"text":457,"correct":26},"排水阀",{"key":28,"text":459,"correct":22},"自动排气阀",{"key":31,"text":461,"correct":22},"泄水阀",{"key":34,"text":463,"correct":26},"排气阀","ABE",{"id":466,"libraryId":5,"type":15,"typeLabel":16,"stem":467,"options":468,"answer":364,"analysis":37},1266845,"通风与空调工程安装完毕，必须进行系统的测定和调整（简称调试）。系统调试应包括下列项目：（ ）。",[469,471,473,475,477],{"key":20,"text":470,"correct":26},"设备单机试运转及调试",{"key":24,"text":472,"correct":26},"系统无生产负荷下的联合试运转及调试",{"key":28,"text":474,"correct":22},"综合效能的测定与调整",{"key":31,"text":476,"correct":22},"有负荷下的联合试运转",{"key":34,"text":478,"correct":22},"无生产负荷的测定与调整",{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":493,"analysis":37},1266846,"下列选项叙述正确的是（ ）。",[483,485,487,489,491],{"key":20,"text":484,"correct":22},"无机玻璃钢风管系统安装后，不合格后也可交到下道工序",{"key":24,"text":486,"correct":22},"无机玻璃钢风管系统严密性检验以支管为主",{"key":28,"text":488,"correct":26},"无机玻璃钢风管系统严密性检验以主、干管为主",{"key":31,"text":490,"correct":26},"低压无机玻璃钢风管系统可采用漏光法检测",{"key":34,"text":492,"correct":26},"无机玻璃钢风管系统安装后，必须进行严密性检验","CDE",{"id":495,"libraryId":5,"type":15,"typeLabel":16,"stem":496,"options":497,"answer":97,"analysis":37},1266847,"下列选项属于水泵按工作原理可分为（ ）。",[498,500,502,504,506],{"key":20,"text":499,"correct":26},"叶片式泵",{"key":24,"text":501,"correct":26},"容积式泵",{"key":28,"text":503,"correct":26},"真空泵",{"key":31,"text":505,"correct":22},"中压泵",{"key":34,"text":507,"correct":22},"高压泵",{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":310,"analysis":37},1266848,"硬质或半硬质绝热管壳的拼接缝隙，保温时不应大于（ ）mm、保冷时不应大（ ）mm，并用粘结材料勾缝填满。",[512,513,514,515,516],{"key":20,"text":320,"correct":26},{"key":24,"text":324,"correct":22},{"key":28,"text":318,"correct":26},{"key":31,"text":332,"correct":22},{"key":34,"text":338,"correct":22},{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":531,"analysis":37},1266849,"通风与空调工程系统无生产负荷的联合试运转及调试，应在制冷设备和通风与空调设备单机试运转合格后进行。空调系统带冷（热）源的正常联合试运转不应少于（ ）通风、除尘系统的连续试运转不应少于（ ）。",[521,523,525,527,529],{"key":20,"text":522,"correct":26},"2h",{"key":24,"text":524,"correct":22},"1h",{"key":28,"text":526,"correct":22},"24h",{"key":31,"text":528,"correct":22},"10h",{"key":34,"text":530,"correct":26},"8h","AE",{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":36,"analysis":37},1266850,"中、低压系统金属风管法兰的螺栓及铆钉孔的孔距不得大于（ ）；高压系统金属风管不得大于（ ）。矩形金属风管法兰的四角部位应设有螺孔。",[536,538,540,542,544],{"key":20,"text":537,"correct":22},"80mm",{"key":24,"text":539,"correct":26},"100mm",{"key":28,"text":541,"correct":22},"120mm",{"key":31,"text":543,"correct":26},"150mm",{"key":34,"text":545,"correct":22},"180mm",{"id":547,"libraryId":5,"type":15,"typeLabel":16,"stem":548,"options":549,"answer":36,"analysis":37},1266851,"通风机试运转应无异常振动，滑动轴承最高温度不得超过（ ）℃，滚动轴承最高温度不得超过（ ）℃。",[550,552,554,556,558],{"key":20,"text":551,"correct":22},"60",{"key":24,"text":553,"correct":26},"70",{"key":28,"text":555,"correct":22},"75",{"key":31,"text":557,"correct":26},"80",{"key":34,"text":559,"correct":22},"85",{"id":561,"libraryId":5,"type":15,"typeLabel":16,"stem":562,"options":563,"answer":421,"analysis":37},1266852,"下面关于热交换新风系统叙述，正确的是（ ）。",[564,566,568,570,572],{"key":20,"text":565,"correct":26},"热交换新风系统可以全天24小时持续不断地将室内污浊空气及时排出",{"key":24,"text":567,"correct":26},"它可以有效控制风量大小",{"key":28,"text":569,"correct":26},"同时可以回收能量",{"key":31,"text":571,"correct":22},"热交换新风系统无需动力提供",{"key":34,"text":573,"correct":26},"为居民提供舒适、健康、节能的居住环境",{"id":575,"libraryId":5,"type":15,"typeLabel":16,"stem":576,"options":577,"answer":154,"analysis":37},1266853,"下列选项中属于防排烟系统构成的是（ ）。",[578,580,582,584,586],{"key":20,"text":579,"correct":26},"自然排烟",{"key":24,"text":581,"correct":22},"自然防烟",{"key":28,"text":583,"correct":26},"机械防烟",{"key":31,"text":585,"correct":26},"机械排烟",{"key":34,"text":587,"correct":22},"消防排烟",{"id":589,"libraryId":5,"type":15,"typeLabel":16,"stem":590,"options":591,"answer":295,"analysis":37},1266854,"下列选项属于常用的非金属风管的是（ ）",[592,594,595,597,599],{"key":20,"text":593,"correct":22},"塑料复合钢板",{"key":24,"text":420,"correct":22},{"key":28,"text":596,"correct":26},"复合风管",{"key":31,"text":598,"correct":26},"玻璃钢风管",{"key":34,"text":600,"correct":22},"镀锌薄钢板",{"id":602,"libraryId":5,"type":15,"typeLabel":16,"stem":603,"options":604,"answer":310,"analysis":37},1266855,"下面对风管连接接口的加固叙述中，正确的是（ ）。",[605,607,609,611,613],{"key":20,"text":606,"correct":26},"接口加固措施一般采用角码和勾码",{"key":24,"text":608,"correct":22},"矩形风管四角采用对角加固措施",{"key":28,"text":610,"correct":26},"在转弯受拉的部位宜采用勾码",{"key":31,"text":612,"correct":22},"在转弯受拉的部位宜采用角码",{"key":34,"text":614,"correct":22},"矩形风管四角采用两个角码加固",{"id":616,"libraryId":5,"type":15,"typeLabel":16,"stem":617,"options":618,"answer":82,"analysis":37},1266856,"下面关于保护壳的质量控制的叙述，正确的是（ ）。",[619,621,623,625,627],{"key":20,"text":620,"correct":26},"保护壳宜用镀锌铁皮、铝皮、不锈钢薄板、彩钢薄板等金属材料制成",{"key":24,"text":622,"correct":26},"设备直径大于1m时，宜采用波形板",{"key":28,"text":624,"correct":26},"设备直径1m以下的采用平板",{"key":31,"text":626,"correct":26},"卧式设备或水平管道的顶部，严禁有接缝",{"key":34,"text":628,"correct":22},"接缝应设在水平中心线上方与水平中心线成60度的范围内",{"id":630,"libraryId":5,"type":15,"typeLabel":16,"stem":631,"options":632,"answer":97,"analysis":37},1266857,"空气调节系统按系统工作压力可分为（ ）。",[633,635,637,639,641],{"key":20,"text":634,"correct":26},"低压系统（P≤500Pa）",{"key":24,"text":636,"correct":26},"中压系统（500Pa＜Pa≤1500Pa）",{"key":28,"text":638,"correct":26},"高压系统（P＞1500Pa）",{"key":31,"text":640,"correct":22},"常压系统（1500＞Pa）",{"key":34,"text":642,"correct":22},"超高压系统（≥2000Pa）",{"id":644,"libraryId":5,"type":15,"typeLabel":16,"stem":645,"options":646,"answer":82,"analysis":37},1266858,"根据《电梯工程施工质量验收规范》GB50310-2002规定，电力驱动的曳引式或强制式电梯进场时，电梯产品供应商应提供（ ）的型式试验证书复印件。",[647,649,651,653,655],{"key":20,"text":648,"correct":26},"门锁装置",{"key":24,"text":650,"correct":26},"限速器",{"key":28,"text":652,"correct":26},"安全钳",{"key":31,"text":654,"correct":26},"缓冲器",{"key":34,"text":656,"correct":22},"限位器",{"id":658,"libraryId":5,"type":15,"typeLabel":16,"stem":659,"options":660,"answer":97,"analysis":37},1266859,"电梯安装工程质量验收应符合下列（ ）规定。",[661,663,665,667,669],{"key":20,"text":662,"correct":26},"参加安装工程施工和质量验收人员应具备相应的资格",{"key":24,"text":664,"correct":26},"承担有关安全性能检测的单位，必须具有相应资质。仪器设备应满足精度要求，并应在检定有效期内",{"key":28,"text":666,"correct":26},"隐蔽工程应在电梯安装单位检查合格后，于隐蔽前通知有关单位检查验收，并形成验收文件",{"key":31,"text":668,"correct":22},"分项工程质量验收均应在电梯安装单位自检合格的基础上进行，按主控项目检查验收",{"key":34,"text":670,"correct":22},"每道工序应符合质量技术监督部门的认可",{"id":672,"libraryId":5,"type":15,"typeLabel":16,"stem":673,"options":674,"answer":464,"analysis":37},1266860,"某电梯安装工程项目，由于电梯工程在高且深的井道内作业，每层在层门安装前留下较大的门洞，因此对于作业人员或其他闲杂人员存在高空坠落危险，针对这一情况，施工项目部对从事影响工程产品质量的所有人员进行了控制。 施工项目部对该电梯工程的施工程序和施工安全技术措施的制定如下：机房通向井道的预留孔随时开通以方便施工；安装好导轨后放基准线进行配管、配线；所有层门洞靠井道壁外侧设置坚固的围封，围封的高度为1.2m；保护围封下部设有高度为150mm的踢脚板，并采用左右开启方式；井道内应设置永久性电气照明，采用36V安全电压。 施工项目部对该电梯工程制定的施工程序和施工安全技术措施中，错误的是（ ）。",[675,677,679,681,683],{"key":20,"text":676,"correct":26},"机房通向井道的预留孔随时开通以方便施工",{"key":24,"text":678,"correct":26},"安装好导轨后放基准线进行配管配线",{"key":28,"text":680,"correct":22},"所有层门洞靠井道壁外侧设置坚固的围封，围封的高度为1.2m",{"key":31,"text":682,"correct":22},"保护围封下部设有高度为150mm的踢脚板，并采用左右开启的方式",{"key":34,"text":684,"correct":26},"井道内应设置永久性电气照明，采用36V安全电压，井道内照度为30lx",{"id":686,"libraryId":5,"type":15,"typeLabel":16,"stem":687,"options":688,"answer":52,"analysis":37},1266861,"根据《电梯工程施工质量验收规范》GB50310-2002规定，电梯安装工程施工质量控制应符合（ ）。",[689,691,693,695,697],{"key":20,"text":690,"correct":26},"电梯安装前应进行土建交接检验",{"key":24,"text":692,"correct":26},"电梯安装前应进行电梯设备进场验收",{"key":28,"text":694,"correct":22},"电梯安装的各分项工程应按国家标准进行质量控制",{"key":31,"text":696,"correct":26},"电梯安装的每个分项工程应有自检记录",{"key":34,"text":698,"correct":22},"施工计划的要求",{"id":700,"libraryId":5,"type":15,"typeLabel":16,"stem":701,"options":702,"answer":67,"analysis":37},1266862,"电梯限速器安全钳联动试验必须符合（ ）规定。",[703,705,707,709,711],{"key":20,"text":704,"correct":22},"限速器与安全钳电气开关在联动试验中必须动作可靠，且应使驱动主机延时制动",{"key":24,"text":706,"correct":26},"对瞬时式安全钳，轿厢应载有均匀分布的额定载重量",{"key":28,"text":708,"correct":26},"对渐进式安全钳，轿厢应载有均匀分布的125％额定载重量",{"key":31,"text":710,"correct":26},"当短接限速器及安全钳电气开关，轿厢以检修速度下行，人为使限速器机械动作时，安全钳应可靠动作，轿厢必须可靠制动，且轿底倾斜度不应大于5%",{"key":34,"text":712,"correct":22},"电梯速度设定值",{"id":714,"libraryId":5,"type":15,"typeLabel":16,"stem":715,"options":716,"answer":727,"analysis":37},1266863,"某电梯安装工程项目，由于电梯工程在高且深的井道内作业，每层在层门安装前留下较大的门洞，因此对于作业人员或其他闲杂人员存在高空坠落危险，针对这一情况，施工项目部对从事影响工程产品质量的所有人员进行了控制。 施工项目部对该电梯工程的施工程序和施工安全技术措施的制定如下：机房通向井道的预留孔随时开通以方便施工；安装好导轨后放基准线进行配管、配线；所有层门洞靠井道壁外侧设置坚固的围封，围封的高度为1.2m；保护围封下部设有高度为150mm的踢脚板，并采用左右开启方式；井道内应设置永久性电气照明，采用36V安全电压。 从空间占位看，电梯一般由（ ）部位组成。",[717,719,721,723,725],{"key":20,"text":718,"correct":26},"机房",{"key":24,"text":720,"correct":26},"井道",{"key":28,"text":722,"correct":22},"层门",{"key":31,"text":724,"correct":26},"轿厢",{"key":34,"text":726,"correct":26},"层站","ABDE",[729,733,736,739,742,745],{"id":730,"name":731,"category":7,"favorite":732},1,"领导干部任职前廉政法规知识测试题",92,{"id":734,"name":735,"category":7,"favorite":730},595,"建筑结构与设备",{"id":737,"name":738,"category":7,"favorite":730},715,"招标采购专业知识与法律法规",{"id":740,"name":741,"category":7,"favorite":730},848,"市政方向-通用基础",{"id":743,"name":744,"category":7,"favorite":8},534,"BIM工程师",{"id":746,"name":744,"category":7,"favorite":8},535]