[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-854-11":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":726},{"id":5,"name":6,"category":7,"favorite":8},854,"(设备安装质量)专业管理实务 岗位知识","建筑工程",0,11,50,1024,[13,38,53,68,83,98,113,128,143,157,171,185,199,214,228,243,258,272,286,300,314,329,343,354,368,381,396,410,425,439,453,467,482,496,510,521,531,545,559,573,587,601,615,629,643,657,671,685,699,713],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},1266764,2,"多选题","依据检定的必要性程度，计量检定可以分为（ ）。",[19,23,26,30,33],{"key":20,"text":21,"correct":22},"A","必要检定",false,{"key":24,"text":25,"correct":22},"B","非必要检定",{"key":27,"text":28,"correct":29},"C","强制性检定",true,{"key":31,"text":32,"correct":29},"D","非强制性检定",{"key":34,"text":35,"correct":22},"E","个别监测","CD","",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":52,"analysis":37},1266765,"室内给水管道的水压试验必须符合设计要求。当设计未注明时，各种材质的给水管道系统试验压力均为工作压力的1.5倍，但不得小于0.6MPa。检验方法：金属及复合管给水管道系统在试验压力下观测（ ），压力降不应大于0.02MPa，然后降到工作压力进行检查，应不渗不漏；塑料管给水系统应在试验压力下稳压（ ），压力降不得超过0.05MPa，然后在工作压力的1.15倍状态下稳压（ ），压力降不得超过0.03MPa，同时检查各连接处不得渗漏。",[42,44,46,48,50],{"key":20,"text":43,"correct":29},"1h",{"key":24,"text":45,"correct":22},"30min",{"key":27,"text":47,"correct":29},"10min",{"key":31,"text":49,"correct":29},"2h",{"key":34,"text":51,"correct":22},"20min","ACD",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":67,"analysis":37},1266766,"敞口水箱的满水试验和密闭水箱（罐）的水压试验必须符合设计与本规范的规定。检验方法：满水试验静置（ ）观察，不渗不漏；水压试验在试验压力下（ ）压力不降，不渗不漏。",[57,59,61,63,65],{"key":20,"text":58,"correct":29},"1Omin",{"key":24,"text":60,"correct":29},"24h",{"key":27,"text":62,"correct":22},"12h",{"key":31,"text":64,"correct":22},"15min",{"key":34,"text":66,"correct":22},"60min","AB",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":82,"analysis":37},1266767,"管道安装坡度，当设计未注明时，应符合下列规定：气、水同向流动的热水供暖管道和汽、水同向流动的蒸汽管道及凝结水管道，坡度应为（ ），不得小于2‰；气、水逆向流动的热水供暖管道和汽、水逆向流动的蒸汽管道，坡度不应小于（ ）；散热器支管的坡度应为（ ），坡向应利于排水和泄水。",[72,74,76,78,80],{"key":20,"text":73,"correct":22},"2‰",{"key":24,"text":75,"correct":29},"3‰",{"key":27,"text":77,"correct":29},"5‰",{"key":31,"text":79,"correct":29},"1%",{"key":34,"text":81,"correct":22},"1‰","BCD",{"id":84,"libraryId":5,"type":15,"typeLabel":16,"stem":85,"options":86,"answer":97,"analysis":37},1266768,"用于室内排水的水平管道与水平管道、水平管道与立管的连接，应采用（ ）或（ ）和（ ）。立管与排出管端部的连接，应采用两个45°弯头或曲率半径不小于4倍管径的90°弯头。",[87,89,91,93,95],{"key":20,"text":88,"correct":29},"45°三通",{"key":24,"text":90,"correct":22},"90°顺水三通",{"key":27,"text":92,"correct":29},"45°四通",{"key":31,"text":94,"correct":29},"90°斜三通",{"key":34,"text":96,"correct":29},"90°斜四通","ACDE",{"id":99,"libraryId":5,"type":15,"typeLabel":16,"stem":100,"options":101,"answer":112,"analysis":37},1266769,"管道穿过墙壁和楼板，应设置金属或塑料套管。安装在楼板内的套管，其顶部咼出装饰地面（ ）；安装在卫生间及厨房内的套管，其顶部应高出装饰地面（ ），底部应与楼板底面相平；安装在墙壁内的套管其两端与饰面相平。穿过楼板的套管与管道之间缝隙应用阻燃密实材料和防水油膏填实，端面光滑。穿墙套管与管道之间缝隙宜用阻燃密实材料填实，且端面应滑。管道的接口不得设在套管内。",[102,104,106,108,110],{"key":20,"text":103,"correct":29},"50mm",{"key":24,"text":105,"correct":22},"30mm",{"key":27,"text":107,"correct":22},"10mm",{"key":31,"text":109,"correct":22},"60mm",{"key":34,"text":111,"correct":29},"20mm","AE",{"id":114,"libraryId":5,"type":15,"typeLabel":16,"stem":115,"options":116,"answer":127,"analysis":37},1266770,"下列关于卫生器具安装的叙述，正确的是（ ）。",[117,119,121,123,125],{"key":20,"text":118,"correct":29},"安装卫生器具时，宜采用预埋乱栓",{"key":24,"text":120,"correct":29},"坐便器固定螺栓不小于M6",{"key":27,"text":122,"correct":29},"便器冲水箱固定螺栓不小于M10",{"key":31,"text":124,"correct":29},"凡是固定卫生器具的螺栓、螺母、垫圈均应使用镀锌件",{"key":34,"text":126,"correct":22},"安装卫生器具时，不可以采用膨胀螺栓安装固定","ABCD",{"id":129,"libraryId":5,"type":15,"typeLabel":16,"stem":130,"options":131,"answer":142,"analysis":37},1266771,"上供下回式系统的热水干管变径应（ ）连接，蒸汽干管变径应（ ）连接。",[132,134,136,138,140],{"key":20,"text":133,"correct":29},"底平偏心",{"key":24,"text":135,"correct":22},"同心",{"key":27,"text":137,"correct":22},"底平异径",{"key":31,"text":139,"correct":29},"顶平偏心",{"key":34,"text":141,"correct":22},"顶平异径","AD",{"id":144,"libraryId":5,"type":15,"typeLabel":16,"stem":145,"options":146,"answer":112,"analysis":37},1266772,"供热锅炉及辅助设备安装，管道、设备和容器的保温，应在（ ）和（ ）合格后进行。",[147,149,151,153,155],{"key":20,"text":148,"correct":29},"防腐",{"key":24,"text":150,"correct":22},"清洗",{"key":27,"text":152,"correct":22},"调试",{"key":31,"text":154,"correct":22},"强度试验",{"key":34,"text":156,"correct":29},"水压试验",{"id":158,"libraryId":5,"type":15,"typeLabel":16,"stem":159,"options":160,"answer":67,"analysis":37},1266773,"下列关于钢管给水安装，正确的选项是（ ）。",[161,163,165,167,169],{"key":20,"text":162,"correct":29},"室外给水钢管一般采用镀锌钢管",{"key":24,"text":164,"correct":29},"镀锌钢管安装全部采用镀锌配件变径和变向",{"key":27,"text":166,"correct":22},"可以用加热的方法制作管件",{"key":31,"text":168,"correct":22},"条件不允许时，可以用黑铁管配件代替镀锌配件",{"key":34,"text":170,"correct":22},"镀锌钢管安装可以不采用镀锌配件变径和变向",{"id":172,"libraryId":5,"type":15,"typeLabel":16,"stem":173,"options":174,"answer":127,"analysis":37},1266774,"下面关于混凝土排水管施工，叙述正确的是（ ）。",[175,177,179,181,183],{"key":20,"text":176,"correct":29},"室外埋地排水管道一般沿道路平行于建筑物铺设",{"key":24,"text":178,"correct":29},"室外排水管道与建筑物的距离不小于3～5m",{"key":27,"text":180,"correct":29},"排水管道的埋设深度，要考虑防止重物压坏和冰冻，一般在管顶以上至少有0.5～0.7m的覆土厚度",{"key":31,"text":182,"correct":29},"排水管道在方向、管径、坡度及高程变化处，以及直线管段上，每隔30～50米地方均应设置污水检查井，以便定期检修和疏通",{"key":34,"text":184,"correct":22},"室外排水管道与建筑物的距离不小于5～7m",{"id":186,"libraryId":5,"type":15,"typeLabel":16,"stem":187,"options":188,"answer":127,"analysis":37},1266775,"下面关于管子规格的叙述中，正确的有（ ）。",[189,191,193,195,197],{"key":20,"text":190,"correct":29},"无缝钢管采用“外径×壁厚”的标注方法",{"key":24,"text":192,"correct":29},"铜管、薄壁不锈钢管等采用公称外径Dw标注",{"key":27,"text":194,"correct":29},"塑料管以公称外径dn标注",{"key":31,"text":196,"correct":29},"铸铁管采用公称直径DN标注",{"key":34,"text":198,"correct":22},"钢筋混凝土管、混凝土管以内径D标注",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":213,"analysis":37},1266776,"建筑给水排水及采暖工程的分项工程，应按（ ）或（ ）等划分。分项工程应划分成若干个检验批进行验收。",[203,205,207,209,211],{"key":20,"text":204,"correct":29},"系统",{"key":24,"text":206,"correct":29},"区域",{"key":27,"text":208,"correct":29},"施工段",{"key":31,"text":210,"correct":22},"专业",{"key":34,"text":212,"correct":29},"楼层","ABCE",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":213,"analysis":37},1266777,"给水塑料管和复合管的连接可以采用下列连接形式：（ ）。",[218,220,222,224,226],{"key":20,"text":219,"correct":29},"橡胶圈接口",{"key":24,"text":221,"correct":29},"粘接接口",{"key":27,"text":223,"correct":29},"热熔连接",{"key":31,"text":225,"correct":22},"套丝连接",{"key":34,"text":227,"correct":29},"法兰连接",{"id":229,"libraryId":5,"type":15,"typeLabel":16,"stem":230,"options":231,"answer":242,"analysis":37},1266778,"下列关于支管安装，叙述正确的是（ ）。",[232,234,236,238,240],{"key":20,"text":233,"correct":29},"支管安装应先将托架按坡度栽好",{"key":24,"text":235,"correct":29},"清扫口与垂直于管道的墙面距离不小于200mm，便于清掏",{"key":27,"text":237,"correct":29},"支管安装完后，可将卫生洁具或设备的预留管安装到位",{"key":31,"text":239,"correct":22},"支管安装时无须用托架，可直接安装",{"key":34,"text":241,"correct":22},"支管安装完后无须堵严楼板孔洞","ABC",{"id":244,"libraryId":5,"type":15,"typeLabel":16,"stem":245,"options":246,"answer":257,"analysis":37},1266779,"阀门的强度和严密性试验，应符合以下规定：阀门的强度试验压力为公称压力的（ ）倍；严密性试验压力为公称压力的（ ）倍；试验压力在试验持续时间内保持不变，且壳体填料及阀瓣密封面无渗漏。",[247,249,251,253,255],{"key":20,"text":248,"correct":22},"1.15",{"key":24,"text":250,"correct":22},"2.0",{"key":27,"text":252,"correct":22},"1.2",{"key":31,"text":254,"correct":29},"1.5",{"key":34,"text":256,"correct":29},"1.1","DE",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":242,"analysis":37},1266780,"管道在穿过结构伸缩缝、防震缝及沉降缝时，管道系统应采取（ ）措施。",[262,264,266,268,270],{"key":20,"text":263,"correct":29},"在墙体两侧采取柔性连接",{"key":24,"text":265,"correct":29},"在管道或保温层外皮上、下部留有不小于150mm的净空",{"key":27,"text":267,"correct":29},"在穿墙处做成方形补偿器，水平安装",{"key":31,"text":269,"correct":22},"在穿墙处安装伸缩器",{"key":34,"text":271,"correct":22},"在管道或保温层外皮上、下部留有不小于200mm的净空",{"id":273,"libraryId":5,"type":15,"typeLabel":16,"stem":274,"options":275,"answer":142,"analysis":37},1266781,"室内消火栓系统安装完成后应取（ ）（或水箱间内）试验消火栓和（ ）消火栓做试射试验，达到设计要求为合格。",[276,278,280,282,284],{"key":20,"text":277,"correct":29},"首层取二处",{"key":24,"text":279,"correct":22},"屋顶层取二处",{"key":27,"text":281,"correct":22},"首层",{"key":31,"text":283,"correct":29},"屋顶层",{"key":34,"text":285,"correct":22},"底层",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":112,"analysis":37},1266782,"建筑给水排水及采暖工程所使用的主要材料、成品、半成品、配件、器具和设备必须具有（ ），规格、型号及（ ）应符合国家技术标准或设计要求。进场时应做检查验收，并经监理工程师核查确认。",[290,292,294,296,298],{"key":20,"text":291,"correct":29},"性能检测报告",{"key":24,"text":293,"correct":22},"试验报告",{"key":27,"text":295,"correct":22},"合格证",{"key":31,"text":297,"correct":22},"质保书",{"key":34,"text":299,"correct":29},"中文质量合格证明文件",{"id":301,"libraryId":5,"type":15,"typeLabel":16,"stem":302,"options":303,"answer":213,"analysis":37},1266783,"关于PSSCP管施工工艺特点的叙述正确的是（ ）。",[304,306,308,310,312],{"key":20,"text":305,"correct":29},"熔接速度快",{"key":24,"text":307,"correct":29},"单口熔接时间一般在15min左右",{"key":27,"text":309,"correct":29},"它的熔接温度低，一般均在200℃",{"key":31,"text":311,"correct":22},"通电的电流大，一般在7A以上",{"key":34,"text":313,"correct":29},"通电的电流小，能耗较低，一般在7A以下",{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":328,"analysis":37},1266784,"下面属于常用管件的是（ ）。",[318,320,322,324,326],{"key":20,"text":319,"correct":22},"焊接钢管管件",{"key":24,"text":321,"correct":29},"无缝钢管管件",{"key":27,"text":323,"correct":29},"可锻铸铁管件",{"key":31,"text":325,"correct":29},"U～PVC管件",{"key":34,"text":327,"correct":29},"球墨铸铁管件","BCDE",{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":331,"options":332,"answer":242,"analysis":37},1266785,"下列关于防水套管的叙述正确的是（ ）。",[333,335,337,339,341],{"key":20,"text":334,"correct":29},"防水套管可以预制加工",{"key":24,"text":336,"correct":29},"管道穿过之处应有严格防水要求",{"key":27,"text":338,"correct":29},"管道穿过之处有振动时，必须采用柔性防水套管",{"key":31,"text":340,"correct":22},"防水套管不能提前预制加工",{"key":34,"text":342,"correct":22},"管道穿过之处防水要求不必很严格",{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":67,"analysis":37},1266786,"隐蔽或埋地的排水管道在隐蔽前必须做灌水试验，其灌水高度应不低于底层卫生器具的上边缘或底层地面高度。检验方法：满水（ ）水面下降后，再灌满观察（ ），液面不降，管道及接口无渗漏为合格。",[347,349,350,352,353],{"key":20,"text":348,"correct":29},"5min",{"key":24,"text":64,"correct":29},{"key":27,"text":351,"correct":22},"2min",{"key":31,"text":47,"correct":22},{"key":34,"text":45,"correct":22},{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":242,"analysis":37},1266787,"给水引人管与排水排出管的水平净距不得小于（ ）。室内给水与排水管道平行敷设时，两管间的最小水平净距不得小于（ ）；交叉铺设时，垂直净距不得小于（ ）。",[358,360,362,364,366],{"key":20,"text":359,"correct":29},"0.5m",{"key":24,"text":361,"correct":29},"0.15m",{"key":27,"text":363,"correct":29},"1m",{"key":31,"text":365,"correct":22},"1.5m",{"key":34,"text":367,"correct":22},"2.0m",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":242,"analysis":37},1266788,"消防水箱、消防水池的容积、安装位置应符合设计要求。安装时，池（箱）外壁与建筑本体结构墙面或其他池壁之间的净距，应满足施工或装配的需要。无管道的侧面，净距不宜小于（ ）m;安装有管道的侧面，净距不宜小于（ ）m，且管道外壁与建筑本体墙面之间的通道宽度不宜小于（ ）m。",[372,374,376,378,380],{"key":20,"text":373,"correct":29},"0.7",{"key":24,"text":375,"correct":29},"1.0",{"key":27,"text":377,"correct":29},"0.6",{"key":31,"text":379,"correct":22},"0.5",{"key":34,"text":252,"correct":22},{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":395,"analysis":37},1266789,"自动喷水灭火系统管道支架、吊架的安装位置不应妨碍喷头的喷水效果，管道支架、吊架与喷头之间的距离不宜小于（ ）mm，与末端喷头之间的距离不宜大于（ ）mm。",[385,387,389,391,393],{"key":20,"text":386,"correct":29},"300",{"key":24,"text":388,"correct":22},"350",{"key":27,"text":390,"correct":29},"750",{"key":31,"text":392,"correct":22},"700",{"key":34,"text":394,"correct":22},"250","AC",{"id":397,"libraryId":5,"type":15,"typeLabel":16,"stem":398,"options":399,"answer":142,"analysis":37},1266790,"当管道变径时，宜采用（ ）；在管道弯头处不宜采用补芯，当需要采用补芯时，三通上可用1个，四通上不应超过2个；公称直径大于50mm的管道不宜采用（ ）。",[400,402,404,406,408],{"key":20,"text":401,"correct":29},"活接头",{"key":24,"text":403,"correct":22},"管箍",{"key":27,"text":405,"correct":22},"弯头",{"key":31,"text":407,"correct":29},"异径接头",{"key":34,"text":409,"correct":22},"补芯",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":424,"analysis":37},1266791,"自动喷水灭火系统热镀锌钢管安装应采用（ ）连接。",[414,416,418,420,422],{"key":20,"text":415,"correct":29},"螺纹",{"key":24,"text":417,"correct":29},"沟槽式管件",{"key":27,"text":419,"correct":22},"焊接",{"key":31,"text":421,"correct":29},"法兰",{"key":34,"text":423,"correct":22},"承插","ABD",{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":424,"analysis":37},1266792,"下面关于水力警铃的叙述，正确的是（ ）。",[429,431,433,435,437],{"key":20,"text":430,"correct":29},"水力警铃应安装在公共通道或值班室附近的外墙上",{"key":24,"text":432,"correct":29},"水力警铃连接管道应采用镀锌钢管",{"key":27,"text":434,"correct":22},"水力警铃的启动压力不应小于0.1MPa",{"key":31,"text":436,"correct":29},"水力警铃的铃锤应转动灵活，无阻滞现象",{"key":34,"text":438,"correct":22},"水力警铃不需安装检修、测试的阀门",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":36,"analysis":37},1266793,"闭式喷头应进行密封性能试验，以无渗漏、无损伤为合格。试验数量宜从每批中抽查1％，但不得少于（ ）只，试验压力应为3.0MPa；保压时间不得少于（ ）min。当两只及两只以上不合格时，不得使用该批喷头。",[443,445,447,449,451],{"key":20,"text":444,"correct":22},"1",{"key":24,"text":446,"correct":22},"2",{"key":27,"text":448,"correct":29},"3",{"key":31,"text":450,"correct":29},"5",{"key":34,"text":452,"correct":22},"10",{"id":454,"libraryId":5,"type":15,"typeLabel":16,"stem":455,"options":456,"answer":466,"analysis":37},1266794,"当管道的公称直径等于或大于（ ）时，每段配水干管或配水管设置防晃支架不应少于1个，且防晃支架的间距不宜大于（ ）m;当管道改变方向时，应增设防晃支架。",[457,459,461,462,464],{"key":20,"text":458,"correct":22},"100",{"key":24,"text":460,"correct":29},"50",{"key":27,"text":452,"correct":22},{"key":31,"text":463,"correct":29},"15",{"key":34,"text":465,"correct":22},"20","BD",{"id":468,"libraryId":5,"type":15,"typeLabel":16,"stem":469,"options":470,"answer":481,"analysis":37},1266795,"自动喷水灭火系统调试应包括下列内容（ ）。",[471,473,475,477,479],{"key":20,"text":472,"correct":29},"水源测试",{"key":24,"text":474,"correct":29},"消防水泵调试",{"key":27,"text":476,"correct":29},"稳压泵调试",{"key":31,"text":478,"correct":29},"报警阀组调试",{"key":34,"text":480,"correct":29},"排水装置调试、联动试验","ABCDE",{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":328,"analysis":37},1266796,"下面关于排烟口的叙述，正确的是（ ）。",[486,488,490,492,494],{"key":20,"text":487,"correct":22},"排烟口平时呈打开状态，以便火灾发生时，能及时排烟",{"key":24,"text":489,"correct":29},"火灾发生时，排烟口可以通过控制中心或手动进行控制",{"key":27,"text":491,"correct":29},"排烟口平时呈常闭状态，火灾发生时才打开",{"key":31,"text":493,"correct":29},"当气流温度达到280℃时，阀门自动关闭达到阻隔烟火的作用",{"key":34,"text":495,"correct":29},"阀门打开后输出开启动作信号，可连锁相关设备运行",{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":97,"analysis":37},1266797,"下列属于自动喷水灭火系统特点的是（ ）。",[500,502,504,506,508],{"key":20,"text":501,"correct":29},"随时警惕火灾，安全可靠，是体现“预防为主、防消结合”方针的最好措施",{"key":24,"text":503,"correct":22},"有利于人员和物资的疏散，但成本高，经济效益较低",{"key":27,"text":505,"correct":29},"协调建筑工业化、现代化与建筑防火某些要求之间的矛盾",{"key":31,"text":507,"correct":29},"使建筑设计具有更大的自由度和灵活性",{"key":34,"text":509,"correct":29},"水利用率高，水渍损失少",{"id":511,"libraryId":5,"type":15,"typeLabel":16,"stem":512,"options":513,"answer":520,"analysis":37},1266798,"自动喷水灭火系统工程质量验收判定条件：（1）系统工程质量缺陷划分为：严重缺陷项 （A），重缺陷项 （B），轻缺陷项 （C）。（2）系统验收合格判定应为：A=0，B≤（ ），且B+C≤（ ）为合格，否则为不合格。",[514,515,517,518,519],{"key":20,"text":444,"correct":22},{"key":24,"text":516,"correct":29},"6",{"key":27,"text":446,"correct":29},{"key":31,"text":450,"correct":22},{"key":34,"text":448,"correct":22},"BC",{"id":522,"libraryId":5,"type":15,"typeLabel":16,"stem":523,"options":524,"answer":466,"analysis":37},1266799,"报警阀组安装的位置应符合设计要求；当设计无要求时，报警阀组应安装在便于操作的明显位置，距室内地面高度宜为（ ）m;两侧与墙的距离不应小于（ ）m;正面与墙的距离不应小于1.2m；报警阀组凸出部位之间的距离不应小于0.5m。安装报警阀组的室内地面应有排水设施。",[525,526,527,528,529],{"key":20,"text":256,"correct":22},{"key":24,"text":252,"correct":29},{"key":27,"text":373,"correct":22},{"key":31,"text":379,"correct":29},{"key":34,"text":530,"correct":22},"0.3",{"id":532,"libraryId":5,"type":15,"typeLabel":16,"stem":533,"options":534,"answer":213,"analysis":37},1266800,"下面对布线系统中数字表达式a～d×（e×f）×g～h中字母代表意思，描述正确的是（ ）。",[535,537,539,541,543],{"key":20,"text":536,"correct":29},"a:线路符号或线路功能的符号",{"key":24,"text":538,"correct":29},"f:导线截面积，不同截面积应分别表示",{"key":27,"text":540,"correct":29},"g:线路敷设方式的符号",{"key":31,"text":542,"correct":22},"h:导线根数",{"key":34,"text":544,"correct":29},"e:导线根数",{"id":546,"libraryId":5,"type":15,"typeLabel":16,"stem":547,"options":548,"answer":424,"analysis":37},1266801,"依法定程序批准进人市场的新型电气设备、器具和材料进场验收，除符合本规范规定外，尚应提供（ ）等技术文件。",[549,551,553,555,557],{"key":20,"text":550,"correct":29},"安装",{"key":24,"text":552,"correct":29},"使用",{"key":27,"text":554,"correct":22},"维护",{"key":31,"text":556,"correct":29},"试验要求",{"key":34,"text":558,"correct":22},"监管",{"id":560,"libraryId":5,"type":15,"typeLabel":16,"stem":561,"options":562,"answer":242,"analysis":37},1266802,"对开关、插座的电气和机械性能进行现场抽样检测应符合（ ）。",[563,565,567,569,571],{"key":20,"text":564,"correct":29},"不同极性带电部件间的电气间隙不应小于3mm，爬电距离不应小于3mm",{"key":24,"text":566,"correct":29},"绝缘电阻值不应小于5M?",{"key":27,"text":568,"correct":29},"金属间相旋合的螺钉螺母，拧紧后完全退出，反复5次应仍然能正常使用",{"key":31,"text":570,"correct":22},"用自攻锁紧螺钉或自切螺钉安装的，螺钉与软塑固定件旋合长度不应小于8mm，绝缘材料固定件在经受5次拧紧退出试验后，应无松动或掉渣，螺钉及螺纹应无损坏现象",{"key":34,"text":572,"correct":22},"监理工程师的要求",{"id":574,"libraryId":5,"type":15,"typeLabel":16,"stem":575,"options":576,"answer":127,"analysis":37},1266803,"当对绝缘导线和电缆的（ ）有异议时，应按批抽样送有资质的试验室检测。检测项目和内容应符合产品技术标准的规定。",[577,579,581,583,585],{"key":20,"text":578,"correct":29},"导电性能",{"key":24,"text":580,"correct":29},"绝缘性能",{"key":27,"text":582,"correct":29},"绝缘厚度",{"key":31,"text":584,"correct":29},"机械性能和阻燃耐火性能",{"key":34,"text":586,"correct":22},"芯线直径",{"id":588,"libraryId":5,"type":15,"typeLabel":16,"stem":589,"options":590,"answer":328,"analysis":37},1266804,"下面关于照明灯具安装的材料检查正确的是（ ）。",[591,593,595,597,599],{"key":20,"text":592,"correct":22},"灯具开箱检查时可能没有技术资料",{"key":24,"text":594,"correct":29},"灯具开箱检查时，要附有产品合格证",{"key":27,"text":596,"correct":29},"灯具开箱检查时要附有说明书，并且安装配件齐全",{"key":31,"text":598,"correct":29},"灯具开箱检查时要有铭牌和强制性产品安全认证标志",{"key":34,"text":600,"correct":29},"灯具经开箱检查后，其规格、型号、电压等级应符合设计要求",{"id":602,"libraryId":5,"type":15,"typeLabel":16,"stem":603,"options":604,"answer":52,"analysis":37},1266805,"下面关于电缆的叙述正确的是（ ）。",[605,607,609,611,613],{"key":20,"text":606,"correct":29},"电缆出厂一般都带有电缆盘，短距离搬运电缆盘可采用滚动",{"key":24,"text":608,"correct":22},"没有保护板的电缆盘，其挡板必须高出电缆外圈200mm",{"key":27,"text":610,"correct":29},"在滚动电缆盘过程中不应损伤电缆",{"key":31,"text":612,"correct":29},"对于短节电缆可按不小于电缆最小弯曲半径将电缆卷成圈，严禁在地面上拖拉",{"key":34,"text":614,"correct":22},"在滚动电缆盘过程中可以不按照电缆盘上箭头指示的方向",{"id":616,"libraryId":5,"type":15,"typeLabel":16,"stem":617,"options":618,"answer":82,"analysis":37},1266806,"导线连接器和接线端子的（ ）应满足设计要求。",[619,621,623,625,627],{"key":20,"text":620,"correct":22},"额定电流",{"key":24,"text":622,"correct":29},"额定电压",{"key":27,"text":624,"correct":29},"连接容量",{"key":31,"text":626,"correct":29},"防护等级",{"key":34,"text":628,"correct":22},"额定电阻",{"id":630,"libraryId":5,"type":15,"typeLabel":16,"stem":631,"options":632,"answer":127,"analysis":37},1266807,"下面关于笼形异步电动机的叙述，正确的是（ ）。",[633,635,637,639,641],{"key":20,"text":634,"correct":29},"凡中心高度为80～315mm，定子铁芯外径为120～500mm的称为小型电动机",{"key":24,"text":636,"correct":29},"凡中心高度为355～630mm，定子铁芯外径为500～1000mm的称为中型电动机",{"key":27,"text":638,"correct":29},"凡中心高度大于630mm的，定子铁芯外径大于1000mm的称为大型电动机",{"key":31,"text":640,"correct":29},"笼形异步电动机是一种使用非常广泛的电动机类型",{"key":34,"text":642,"correct":22},"凡中心高度为315～630mm，定子铁芯外径为500～1000mm的称为中型电动机",{"id":644,"libraryId":5,"type":15,"typeLabel":16,"stem":645,"options":646,"answer":127,"analysis":37},1266808,"下列关于高低压开关柜的叙述，正确的是（ ）。",[647,649,651,653,655],{"key":20,"text":648,"correct":29},"高压开关柜用于开断或关合额定电压为1KV及以上线路的电器设备",{"key":24,"text":650,"correct":29},"高压开关柜有固定式和手车式两类",{"key":27,"text":652,"correct":29},"常用的高压开关按其功能分为断路器、负荷开关、隔离开关和接地开关",{"key":31,"text":654,"correct":29},"低压开关柜也即低压配电屏，用于频率为50Hz，额定电压380V及以下的低压配电系统",{"key":34,"text":656,"correct":22},"低压开关柜有固定式和手车式两类",{"id":658,"libraryId":5,"type":15,"typeLabel":16,"stem":659,"options":660,"answer":213,"analysis":37},1266809,"下面关于管内布线的叙述，正确的是（ ）。",[661,663,665,667,669],{"key":20,"text":662,"correct":29},"管内布线指的是把绝缘电线穿在管内敷设",{"key":24,"text":664,"correct":29},"这种布线方式比较安全可靠",{"key":27,"text":666,"correct":29},"可以避免腐蚀性气体的侵蚀",{"key":31,"text":668,"correct":22},"但是更换电线不方便",{"key":34,"text":670,"correct":29},"可避免机械损伤",{"id":672,"libraryId":5,"type":15,"typeLabel":16,"stem":673,"options":674,"answer":36,"analysis":37},1266810,"控制电缆（ ）合格，才能接线。",[675,677,679,681,683],{"key":20,"text":676,"correct":22},"交接试验",{"key":24,"text":678,"correct":22},"相位核对",{"key":27,"text":680,"correct":29},"绝缘电阻测试",{"key":31,"text":682,"correct":29},"校线",{"key":34,"text":684,"correct":22},"现场抽样检测",{"id":686,"libraryId":5,"type":15,"typeLabel":16,"stem":687,"options":688,"answer":242,"analysis":37},1266811,"在同一场所安装的（ ）的插座，应有明显的区别，且不能互换。",[689,691,693,695,697],{"key":20,"text":690,"correct":29},"交流",{"key":24,"text":692,"correct":29},"直流",{"key":27,"text":694,"correct":29},"不同电压等级",{"key":31,"text":696,"correct":22},"不同电阻",{"key":34,"text":698,"correct":22},"不同厂家",{"id":700,"libraryId":5,"type":15,"typeLabel":16,"stem":701,"options":702,"answer":97,"analysis":37},1266812,"下面关于绝缘导管的叙述，正确的是（ ）。",[703,705,707,709,711],{"key":20,"text":704,"correct":29},"绝缘导管按其硬度可分为刚性绝缘导管和可弯曲绝缘导管",{"key":24,"text":706,"correct":22},"刚性绝缘导管在弯曲过程中不能进行特殊加工",{"key":27,"text":708,"correct":29},"由于绝缘导管的硬度不同，其安装过程的制作加工方法也不尽相同",{"key":31,"text":710,"correct":29},"施工现场使用较多的是刚性绝缘导管",{"key":34,"text":712,"correct":29},"可弯曲绝缘导管不用借助于其他装置，只用适当的力就能用手弯曲",{"id":714,"libraryId":5,"type":15,"typeLabel":16,"stem":715,"options":716,"answer":67,"analysis":37},1266813,"防雷引下线与接地装置之间的连接方式为（ ）。",[717,719,720,722,724],{"key":20,"text":718,"correct":29},"螺栓连接",{"key":24,"text":419,"correct":29},{"key":27,"text":721,"correct":22},"搭接",{"key":31,"text":723,"correct":22},"卡接器连接",{"key":34,"text":725,"correct":22},"机械连接",[727,731,734,737,740,743],{"id":728,"name":729,"category":7,"favorite":730},1,"领导干部任职前廉政法规知识测试题",92,{"id":732,"name":733,"category":7,"favorite":728},595,"建筑结构与设备",{"id":735,"name":736,"category":7,"favorite":728},715,"招标采购专业知识与法律法规",{"id":738,"name":739,"category":7,"favorite":728},848,"市政方向-通用基础",{"id":741,"name":742,"category":7,"favorite":8},534,"BIM工程师",{"id":744,"name":742,"category":7,"favorite":8},535]