[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-853-5":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":619},{"id":5,"name":6,"category":7,"favorite":8},853,"(设备安装质量)基础知识","建筑工程",0,5,50,1092,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,213,225,237,249,261,271,283,295,307,319,331,343,355,367,379,391,403,415,427,439,451,463,475,487,499,511,523,535,547,559,571,583,595,607],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},1265313,1,"单选题","安装胀锚地脚螺栓的基础混凝土强度不得小于。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","5MPa",false,{"key":24,"text":25,"correct":26},"B","10MPa",true,{"key":28,"text":29,"correct":22},"C","15MPa",{"key":31,"text":32,"correct":22},"D","20MPa","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},1265314,"防雷接地模块的安装要满足有关规范的规定，通常接地模块顶面埋深不应小于（。",[38,40,42,44],{"key":20,"text":39,"correct":22},"03m",{"key":24,"text":41,"correct":22},"0.4m",{"key":28,"text":43,"correct":22},"0.5m",{"key":31,"text":45,"correct":26},"0.6m",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},1265315,"绝热层施工技术要求描述错误的一项是。",[50,52,54,56],{"key":20,"text":51,"correct":26},"当采用一种绝热制品.保温层厚度大于或等于50mm.应分为两层或多层逐层施工.各层的厚度宜接近",{"key":24,"text":53,"correct":22},"当采用软质或半硬质可压缩性的绝热制品时.安装厚度应符合设计规定",{"key":28,"text":55,"correct":22},"同层应错缝.上下层应压缝.其搭接长度不宜小于100mm",{"key":31,"text":57,"correct":22},"硬质或半硬质材料作保温层.拼接宽度不应大于5mm",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},1265318,"计量器具依法管理中，为保证使用中的计量器具的量值准确可靠，应按规定实施（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"首次检定",{"key":24,"text":65,"correct":22},"后续检定",{"key":28,"text":67,"correct":26},"周期检定",{"key":31,"text":69,"correct":22},"仲裁检定",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":28,"analysis":33},1265319,"金属切削机床的静态特性包括（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"运动精度",{"key":24,"text":77,"correct":22},"热变形",{"key":28,"text":79,"correct":26},"刚度",{"key":31,"text":81,"correct":22},"噪声",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":31,"analysis":33},1265321,"电缆敷设时，油浸纸质绝缘电力电缆切断后，必须（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"保证切断处高于邻近两侧电缆",{"key":24,"text":89,"correct":22},"做防潮封端",{"key":28,"text":91,"correct":22},"压板固定",{"key":31,"text":93,"correct":26},"铅封",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":31,"analysis":33},1265322,"组合式空调机组安装中，空气设备与管道连接时，应设置（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":22},"法兰连接",{"key":24,"text":101,"correct":22},"焊接连接",{"key":28,"text":103,"correct":22},"咬口连接",{"key":31,"text":105,"correct":26},"软连接",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},1265324,"根据（ ）的机理，可以分为风压作用下的自然通风、热压作用下的自然通风以及热压和风压共同作用下的自然通风。",[110,112,114,116],{"key":20,"text":111,"correct":22},"空气流动",{"key":24,"text":113,"correct":26},"压差形成",{"key":28,"text":115,"correct":22},"温度变化",{"key":31,"text":117,"correct":22},"空气湿度",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":20,"analysis":33},1265325,"三极管工作于放大状态的条件是（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":26},"发射结正偏，集电结反偏",{"key":24,"text":125,"correct":22},"发射结正偏，集电结正偏",{"key":28,"text":127,"correct":22},"发射结反偏，集电结正偏",{"key":31,"text":129,"correct":22},"发射结反偏，集电结反偏",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":24,"analysis":33},1265326,"工程项目质量检验的“三检制”不包括。",[134,136,138,140],{"key":20,"text":135,"correct":22},"操作人员的自检",{"key":24,"text":137,"correct":26},"专职检验人员的终检",{"key":28,"text":139,"correct":22},"操作人员的互检",{"key":31,"text":141,"correct":22},"专职质量管理人员的专检",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":28,"analysis":33},1265327,"在卷扬机工作时，由卷筒到最后一个导向滑车的水平直线距离不应小于卷筒长度的（ ）。",[146,148,150,152],{"key":20,"text":147,"correct":22},"15倍",{"key":24,"text":149,"correct":22},"20倍",{"key":28,"text":151,"correct":26},"25倍",{"key":31,"text":153,"correct":22},"30倍",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":31,"analysis":33},1265328,"工业炉窑砌筑工程的工序交接证明书中，炉体冷却装置、管道和炉壳应有试压记录及（ ）。",[158,160,162,164],{"key":20,"text":159,"correct":22},"超声波探伤记录",{"key":24,"text":161,"correct":22},"试运转合格的记录",{"key":28,"text":163,"correct":22},"压力容器施工许可证明",{"key":31,"text":165,"correct":26},"焊接严密性试验验收合格的证明",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":20,"analysis":33},1265329,"根据（ ）和实际使用情况，合理安排好每种计量器具的检定周期。",[170,172,174,176],{"key":20,"text":171,"correct":26},"计量检定规程",{"key":24,"text":173,"correct":22},"设计要求",{"key":28,"text":175,"correct":22},"计量器具种类",{"key":31,"text":177,"correct":22},"精度等级",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":20,"analysis":33},1265330,"过路箱一般作暗配线时电缆管线的（ ）或接续用，箱内不应有其他管线穿过。",[182,184,186,188],{"key":20,"text":183,"correct":26},"转接",{"key":24,"text":185,"correct":22},"跳线",{"key":28,"text":187,"correct":22},"间断",{"key":31,"text":189,"correct":22},"间隔",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":28,"analysis":33},1265331,"现代化网形屋架的水平控制，最先进的测量仪器是（ ）。",[194,196,198,200],{"key":20,"text":195,"correct":22},"激光准直仪",{"key":24,"text":197,"correct":22},"激光水准仪",{"key":28,"text":199,"correct":26},"激光平面仪",{"key":31,"text":201,"correct":22},"激光指向仪",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":28,"analysis":33},1265332,"进行高电压试验时，操作人员与高电压回路间应该具有足够的安全距离。如电压等级为6-10kV，不设防护栅时，最小安全距离为（。",[206,208,209,211],{"key":20,"text":207,"correct":22},"1m",{"key":24,"text":43,"correct":22},{"key":28,"text":210,"correct":26},"0.7m",{"key":31,"text":212,"correct":22},"1.2m",{"id":214,"libraryId":5,"type":15,"typeLabel":16,"stem":215,"options":216,"answer":24,"analysis":33},1265333,"设备安装前，要求对设备基础位置和几何尺寸进行（ ），其允许偏差应符合设计文件或国家现行有关规范的规定。",[217,219,221,223],{"key":20,"text":218,"correct":22},"查看",{"key":24,"text":220,"correct":26},"复检",{"key":28,"text":222,"correct":22},"交接验收",{"key":31,"text":224,"correct":22},"施工记录检查",{"id":226,"libraryId":5,"type":15,"typeLabel":16,"stem":227,"options":228,"answer":20,"analysis":33},1265334,"有热位移的管道，吊点应设在位移的相反方向，按位移值的（ ）偏位安装。",[229,231,233,235],{"key":20,"text":230,"correct":26},"1\u002F2",{"key":24,"text":232,"correct":22},"1\u002F3",{"key":28,"text":234,"correct":22},"1\u002F4",{"key":31,"text":236,"correct":22},"1\u002F5",{"id":238,"libraryId":5,"type":15,"typeLabel":16,"stem":239,"options":240,"answer":20,"analysis":33},1265335,"（ ）是依靠通风机提供的动力来迫使空气流通来进行室内外空气交换的方式。",[241,243,245,247],{"key":20,"text":242,"correct":26},"机械通风",{"key":24,"text":244,"correct":22},"自然通风",{"key":28,"text":246,"correct":22},"换气通风",{"key":31,"text":248,"correct":22},"局部通风",{"id":250,"libraryId":5,"type":15,"typeLabel":16,"stem":251,"options":252,"answer":28,"analysis":33},1265336,"机电工程技术经济的特点不包括（ ）。",[253,255,257,259],{"key":20,"text":254,"correct":22},"综合性",{"key":24,"text":256,"correct":22},"预测性",{"key":28,"text":258,"correct":26},"时效性",{"key":31,"text":260,"correct":22},"比较性",{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":20,"analysis":33},1265337,"将激光束置于铅直方向以进行竖向准直的仪器是。",[265,267,269,270],{"key":20,"text":266,"correct":26},"激光垂线仪",{"key":24,"text":268,"correct":22},"激光经纬仪",{"key":28,"text":199,"correct":22},{"key":31,"text":197,"correct":22},{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":31,"analysis":33},1265338,"电路的功率因数是由负载中包含的（ ）所决定的。",[275,277,279,281],{"key":20,"text":276,"correct":22},"电阻",{"key":24,"text":278,"correct":22},"电容",{"key":28,"text":280,"correct":22},"电感",{"key":31,"text":282,"correct":26},"电阻和电抗的相对大小",{"id":284,"libraryId":5,"type":15,"typeLabel":16,"stem":285,"options":286,"answer":31,"analysis":33},1265339,"两个20?电阻串联后的总电阻是（ ）。",[287,289,291,293],{"key":20,"text":288,"correct":22},"5?",{"key":24,"text":290,"correct":22},"10?",{"key":28,"text":292,"correct":22},"20?",{"key":31,"text":294,"correct":26},"40?",{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":297,"options":298,"answer":28,"analysis":33},1265341,"交流电在某一时刻的值称为在这一时刻交流电的（ ）。",[299,301,303,305],{"key":20,"text":300,"correct":22},"有效值",{"key":24,"text":302,"correct":22},"最大值",{"key":28,"text":304,"correct":26},"瞬时值",{"key":31,"text":306,"correct":22},"平均值",{"id":308,"libraryId":5,"type":15,"typeLabel":16,"stem":309,"options":310,"answer":24,"analysis":33},1265342,"当XL＞XC时，总电压（ ）电流，称为（ ）电路。",[311,313,315,317],{"key":20,"text":312,"correct":22},"超前容性",{"key":24,"text":314,"correct":26},"超前感性",{"key":28,"text":316,"correct":22},"延迟容性",{"key":31,"text":318,"correct":22},"延迟感性",{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":20,"analysis":33},1265343,"一类防雷建筑的屋顶避雷网格间距为（ ）。",[323,325,327,329],{"key":20,"text":324,"correct":26},"5m×5m",{"key":24,"text":326,"correct":22},"lOm×lOm",{"key":28,"text":328,"correct":22},"15m×15m",{"key":31,"text":330,"correct":22},"20m×20m",{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":28,"analysis":33},1265344,"空气分配部分主要包括设置在不同位置的（ ）和回风口，作用是合理地组织空调房间的空气流动。",[335,337,339,341],{"key":20,"text":336,"correct":22},"送风管",{"key":24,"text":338,"correct":22},"回风管",{"key":28,"text":340,"correct":26},"送风口",{"key":31,"text":342,"correct":22},"风机盘管",{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":20,"analysis":33},1265345,"安全阀的出口管道应接向安全地点，安全阀安装应满足（ ）安装。",[347,349,351,353],{"key":20,"text":348,"correct":26},"垂直",{"key":24,"text":350,"correct":22},"倾角60°",{"key":28,"text":352,"correct":22},"倾角30°",{"key":31,"text":354,"correct":22},"水平",{"id":356,"libraryId":5,"type":15,"typeLabel":16,"stem":357,"options":358,"answer":20,"analysis":33},1265346,"（ ）的作用是自动而且迅速地排出用热设备及管道中的凝水，并能阻止蒸汽逸漏。",[359,361,363,365],{"key":20,"text":360,"correct":26},"蒸汽疏水器",{"key":24,"text":362,"correct":22},"减压阀",{"key":28,"text":364,"correct":22},"过滤器",{"key":31,"text":366,"correct":22},"安全阀",{"id":368,"libraryId":5,"type":15,"typeLabel":16,"stem":369,"options":370,"answer":20,"analysis":33},1265347,"根据集中式系统处理空气来源分类，系统可分为（ ）、直流式系统和混合式系统。",[371,373,375,377],{"key":20,"text":372,"correct":26},"封闭式系统",{"key":24,"text":374,"correct":22},"开放式系统",{"key":28,"text":376,"correct":22},"全空气系统",{"key":31,"text":378,"correct":22},"全水系统",{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":381,"options":382,"answer":28,"analysis":33},1265350,"二极管当中，硅管的开启电压约为（ ）V，锗管约为（ ）V。",[383,385,387,389],{"key":20,"text":384,"correct":22},"0.10.2",{"key":24,"text":386,"correct":22},"0.20.3",{"key":28,"text":388,"correct":26},"0.50.1",{"key":31,"text":390,"correct":22},"0.50.4",{"id":392,"libraryId":5,"type":15,"typeLabel":16,"stem":393,"options":394,"answer":24,"analysis":33},1265351,"建筑电气工程中，室内配电线路的导线敷设时，零线绝缘层的颜色为（ ）。",[395,397,399,401],{"key":20,"text":396,"correct":22},"黄色",{"key":24,"text":398,"correct":26},"淡蓝色",{"key":28,"text":400,"correct":22},"绿色",{"key":31,"text":402,"correct":22},"黄绿双色",{"id":404,"libraryId":5,"type":15,"typeLabel":16,"stem":405,"options":406,"answer":20,"analysis":33},1265352,"危险等级分值在160-320是属于（ ）危险程度。",[407,409,411,413],{"key":20,"text":408,"correct":26},"高度危险.不可能继续作业",{"key":24,"text":410,"correct":22},"一般危险.需要注意",{"key":28,"text":412,"correct":22},"极其危险.不可能继续作业",{"key":31,"text":414,"correct":22},"显著危险.需要整改",{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":417,"options":418,"answer":20,"analysis":33},1265354,"关于无损检测人员的要求，下列说法中错误的是（ ）。",[419,421,423,425],{"key":20,"text":420,"correct":26},"工级人员可进行签发检测报告的工作",{"key":24,"text":422,"correct":22},"Ⅱ级人员可进行评定检测结果的工作",{"key":28,"text":424,"correct":22},"Ⅲ级人员可进行审核检测报告的工作",{"key":31,"text":426,"correct":22},"Ⅲ级人员可进行无损检测工艺的编制工作",{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":24,"analysis":33},1265355,"两个同频率正弦交流电流i1、i2的有效值各为40A和30A。当i1+i2的有效值为50A时，i1与i2的相位差是（ ）。",[431,433,435,437],{"key":20,"text":432,"correct":22},"0°",{"key":24,"text":434,"correct":26},"90°",{"key":28,"text":436,"correct":22},"180°",{"key":31,"text":438,"correct":22},"270°",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":24,"analysis":33},1265356,"下列关于桅杆起重机安装中地锚的说法，正确的是（ ）。",[443,445,447,449],{"key":20,"text":444,"correct":22},"应根据设备位置和使用工况选用地锚",{"key":24,"text":446,"correct":26},"全埋式地锚适用于有开挖条件的场地",{"key":28,"text":448,"correct":22},"压重式地锚多在大型吊装中使用",{"key":31,"text":450,"correct":22},"利用已有建筑物作为地锚，必须获得建筑物使用单位的同意",{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":453,"options":454,"answer":20,"analysis":33},1265357,"施工机械设备操作人员的要求中，“四懂三会”中的“三会”不包括（ ）。",[455,457,459,461],{"key":20,"text":456,"correct":26},"会安装",{"key":24,"text":458,"correct":22},"会排除故障",{"key":28,"text":460,"correct":22},"会操作",{"key":31,"text":462,"correct":22},"会保养",{"id":464,"libraryId":5,"type":15,"typeLabel":16,"stem":465,"options":466,"answer":20,"analysis":33},1265358,"下列工程塑料中，可燃热变形温度较低、耐候性较差的是（ ）。",[467,469,471,473],{"key":20,"text":468,"correct":26},"ABS塑料",{"key":24,"text":470,"correct":22},"聚碳酸酯",{"key":28,"text":472,"correct":22},"聚甲醛",{"key":31,"text":474,"correct":22},"聚酰胺",{"id":476,"libraryId":5,"type":15,"typeLabel":16,"stem":477,"options":478,"answer":20,"analysis":33},1265359,"在管道安装前的阀门检验中，阀门应进行壳体试验压力和密封试验，阀门壳体试验压力和密封试样应以（ ）为介质。",[479,481,483,485],{"key":20,"text":480,"correct":26},"洁净水",{"key":24,"text":482,"correct":22},"压缩空气",{"key":28,"text":484,"correct":22},"净化纯气",{"key":31,"text":486,"correct":22},"燃油",{"id":488,"libraryId":5,"type":15,"typeLabel":16,"stem":489,"options":490,"answer":20,"analysis":33},1265360,"下列物质中，属于无机绝缘材料的是。",[491,493,495,497],{"key":20,"text":492,"correct":26},"大理石",{"key":24,"text":494,"correct":22},"矿物油",{"key":28,"text":496,"correct":22},"虫胶",{"key":31,"text":498,"correct":22},"树脂",{"id":500,"libraryId":5,"type":15,"typeLabel":16,"stem":501,"options":502,"answer":31,"analysis":33},1265361,"交流电的周期的单位是（ ）。",[503,505,507,509],{"key":20,"text":504,"correct":22},"m",{"key":24,"text":506,"correct":22},"v\u002Fs",{"key":28,"text":508,"correct":22},"kg",{"key":31,"text":510,"correct":26},"s",{"id":512,"libraryId":5,"type":15,"typeLabel":16,"stem":513,"options":514,"answer":31,"analysis":33},1265362,"供电企业的用电营业机构统一归口办理用户的（ ）和报装接电工作。",[515,517,519,521],{"key":20,"text":516,"correct":22},"用电安全检查",{"key":24,"text":518,"correct":22},"用电维修人员审定",{"key":28,"text":520,"correct":22},"用电计划制定",{"key":31,"text":522,"correct":26},"用电申请",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":31,"analysis":33},1265363,"高层建筑为防侧击雷而设计的环绕建筑物周边的水平避雷带是。",[527,529,531,533],{"key":20,"text":528,"correct":22},"避雷针",{"key":24,"text":530,"correct":22},"避雷带（网）",{"key":28,"text":532,"correct":22},"防雷引下线",{"key":31,"text":534,"correct":26},"均压环",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":24,"analysis":33},1265364,"交流电在一秒内完成周期性变化的次数称交流电的（ ）。",[539,541,543,545],{"key":20,"text":540,"correct":22},"周期",{"key":24,"text":542,"correct":26},"频率",{"key":28,"text":544,"correct":22},"赫兹",{"key":31,"text":546,"correct":22},"相位",{"id":548,"libraryId":5,"type":15,"typeLabel":16,"stem":549,"options":550,"answer":24,"analysis":33},1265365,"建筑给水系统按供水对象，可分为生活、生产、（ ）三类基本的给水系统。",[551,553,555,557],{"key":20,"text":552,"correct":22},"自喷系统",{"key":24,"text":554,"correct":26},"消防",{"key":28,"text":556,"correct":22},"自来水",{"key":31,"text":558,"correct":22},"市政供水",{"id":560,"libraryId":5,"type":15,"typeLabel":16,"stem":561,"options":562,"answer":24,"analysis":33},1265366,"消防水泵及稳压泵的施工程序中，泵体安装的紧后工序是（ ）。",[563,565,567,569],{"key":20,"text":564,"correct":22},"泵体稳固",{"key":24,"text":566,"correct":26},"吸水管路安装",{"key":28,"text":568,"correct":22},"压水管路安装",{"key":31,"text":570,"correct":22},"单机调试",{"id":572,"libraryId":5,"type":15,"typeLabel":16,"stem":573,"options":574,"answer":28,"analysis":33},1265367,"（ ）是半集中式空调系统的末端装置，它由风机、盘管（换热器）以及电动机、空气过滤器、室温调节器和箱体组成。",[575,577,579,581],{"key":20,"text":576,"correct":22},"涡旋式机组",{"key":24,"text":578,"correct":22},"螺杆式机组",{"key":28,"text":580,"correct":26},"风机盘管机组",{"key":31,"text":582,"correct":22},"活塞式机组",{"id":584,"libraryId":5,"type":15,"typeLabel":16,"stem":585,"options":586,"answer":20,"analysis":33},1265369,"工程测量程序中，安装过程测量控制的紧前程序是。",[587,589,591,593],{"key":20,"text":588,"correct":26},"设置沉降观测点",{"key":24,"text":590,"correct":22},"设置标高基准点",{"key":28,"text":592,"correct":22},"设置纵横中心线",{"key":31,"text":594,"correct":22},"建立测量控制网",{"id":596,"libraryId":5,"type":15,"typeLabel":16,"stem":597,"options":598,"answer":28,"analysis":33},1265370,"在高层建筑管道施工中，安装坡度为1%的供暖管道是（ ）。",[599,601,603,605],{"key":20,"text":600,"correct":22},"热水供暖管道",{"key":24,"text":602,"correct":22},"蒸汽管道",{"key":28,"text":604,"correct":26},"散热器支管道",{"key":31,"text":606,"correct":22},"凝结水管道",{"id":608,"libraryId":5,"type":15,"typeLabel":16,"stem":609,"options":610,"answer":31,"analysis":33},1265371,"下列器具中，用于工艺控制、质量检测及物资管理的计量器具是（ ）。",[611,613,615,617],{"key":20,"text":612,"correct":22},"兆欧表",{"key":24,"text":614,"correct":22},"接地电阻测量仪",{"key":28,"text":616,"correct":22},"5m钢卷尺",{"key":31,"text":618,"correct":26},"万用表",[620,623,626,629,632,635],{"id":15,"name":621,"category":7,"favorite":622},"领导干部任职前廉政法规知识测试题",92,{"id":624,"name":625,"category":7,"favorite":15},595,"建筑结构与设备",{"id":627,"name":628,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":630,"name":631,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":633,"name":634,"category":7,"favorite":8},534,"BIM工程师",{"id":636,"name":634,"category":7,"favorite":8},535]