[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-853-4":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":624},{"id":5,"name":6,"category":7,"favorite":8},853,"(设备安装质量)基础知识","建筑工程",0,4,50,1092,[13,38,52,64,76,86,101,116,126,138,150,161,173,185,197,206,221,233,245,257,269,281,293,305,317,329,341,353,365,377,389,401,413,425,437,446,458,470,481,493,505,517,529,541,553,565,576,588,600,612],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},1265259,2,"多选题","设备、材料的采购供应中要明确监控系统设备供应商和被监控设备供应商之间的界面划分，主要是明确建筑设备监控系统与其他机电工程的（ ）的供应范围。",[19,23,26,29,33],{"key":20,"text":21,"correct":22},"A","设备",true,{"key":24,"text":25,"correct":22},"B","材料",{"key":27,"text":28,"correct":22},"C","接口",{"key":30,"text":31,"correct":32},"D","动力",false,{"key":34,"text":35,"correct":22},"E","软件","ABCE","",{"id":39,"libraryId":5,"type":40,"typeLabel":41,"stem":42,"options":43,"answer":30,"analysis":37},1265260,1,"单选题","某安装公司中标了C市一大型写字楼机电安装工程，内容包含室内给水排水、电气照明、配电房、通风与空调系统、消防及智能化监控系统等。项目部在施工过程中严格遵守施工规范及验收标准，利用PDCA循环加强质量控制。项目最终验收合格，顺利投人使用。根据背景材料，回答以下问题。 5月时施工班组完成了室内给水管道的安装，后续工艺流程正确的是（ ）。",[44,46,48,50],{"key":20,"text":45,"correct":32},"压力试验→冲洗消毒→防腐绝热→通水验收",{"key":24,"text":47,"correct":32},"防腐绝热→压力试验→冲洗消毒→通水验收",{"key":27,"text":49,"correct":32},"防腐绝热→冲洗消毒→压力试验→通水验收",{"key":30,"text":51,"correct":22},"压力试验→防腐绝热→冲洗消毒→通水验收",{"id":53,"libraryId":5,"type":40,"typeLabel":41,"stem":54,"options":55,"answer":24,"analysis":37},1265261,"敷设导管，当线路明配时，电线保护管的弯曲半径不宜小于管外径的（ ）倍。",[56,58,60,62],{"key":20,"text":57,"correct":32},"8",{"key":24,"text":59,"correct":22},"6",{"key":27,"text":61,"correct":32},"4",{"key":30,"text":63,"correct":32},"3",{"id":65,"libraryId":5,"type":40,"typeLabel":41,"stem":66,"options":67,"answer":24,"analysis":37},1265262,"照明配电箱应安装牢固，照明配电箱底边距地面高度不宜小于（ ）。",[68,70,72,74],{"key":20,"text":69,"correct":32},"2.0",{"key":24,"text":71,"correct":22},"1.8",{"key":27,"text":73,"correct":32},"1.5",{"key":30,"text":75,"correct":32},"1.2",{"id":77,"libraryId":5,"type":40,"typeLabel":41,"stem":78,"options":79,"answer":24,"analysis":37},1265263,"当梁、通风管道、排管、桥架等障碍物的宽度大于（ ）m时，其下方应增设喷头。",[80,81,82,84],{"key":20,"text":73,"correct":32},{"key":24,"text":75,"correct":22},{"key":27,"text":83,"correct":32},"1.1",{"key":30,"text":85,"correct":32},"1.0",{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":100,"analysis":37},1265264,"关于净化空调系统的施工，以下正确的有（ ）。",[90,92,94,96,98],{"key":20,"text":91,"correct":32},"空气洁净度NI、N5级的洁净室，风管、附件的制作与安装应符合中压风管系统的相关要求",{"key":24,"text":93,"correct":22},"洁净度等级NI、N5级的风管系统，不得采用按扣式咬口",{"key":27,"text":95,"correct":32},"风管及部件的缝隙处不得利用密封胶密封",{"key":30,"text":97,"correct":22},"现场组装的组合式空气处理机组安装完毕后应进行漏风量检测",{"key":34,"text":99,"correct":22},"净化空调系统风管的安装，应在其安装部位的地面已施工完成，室内具有防尘措施的条件下进行","BDE",{"id":102,"libraryId":5,"type":15,"typeLabel":16,"stem":103,"options":104,"answer":115,"analysis":37},1265265,"关于消防控制设备的布置，以下错误的有（ ）。",[105,107,109,111,113],{"key":20,"text":106,"correct":22},"设备单列布置时，面盘前的操作距离不应小于2m",{"key":24,"text":108,"correct":32},"在值班人员经常工作的一面，设备面盘与墙的距离不应小于3m",{"key":27,"text":110,"correct":22},"设备面盘后的维修距离不应小于1.5m",{"key":30,"text":112,"correct":32},"控制盘的排列长度大于4m时，控制盘两端应设宽度不小于1m的通道",{"key":34,"text":114,"correct":32},"集中火灾报警控制器安装在墙上时，其底边距地高度宜为1.3~1.5m","AC",{"id":117,"libraryId":5,"type":118,"typeLabel":119,"stem":120,"options":121,"answer":125,"analysis":37},1265266,3,"判断题","风管安装连接后，在刷油、绝热后应按规范进行严密性、漏风量检测。",[122,124],{"key":20,"text":123,"correct":32},"正确",{"key":24,"text":125,"correct":22},"错误",{"id":127,"libraryId":5,"type":40,"typeLabel":41,"stem":128,"options":129,"answer":24,"analysis":37},1265267,"管道安装一般应本着先主管后支管、先上部后下部、（ ）的原则进行安装。",[130,132,134,136],{"key":20,"text":131,"correct":32},"先外后里",{"key":24,"text":133,"correct":22},"先里后外",{"key":27,"text":135,"correct":32},"先中间后两侧",{"key":30,"text":137,"correct":32},"先两侧后中间",{"id":139,"libraryId":5,"type":40,"typeLabel":41,"stem":140,"options":141,"answer":27,"analysis":37},1265268,"关于消声器的安装，以下错误的是（ ）。",[142,144,146,148],{"key":20,"text":143,"correct":32},"应单独设支架，使风管不承受其重量",{"key":24,"text":145,"correct":32},"消声器支架的横担板穿吊杆的螺孔距离，应比消声器宽40、50mm",{"key":27,"text":147,"correct":22},"为便于调节标高，可在吊杆端部套50、80mm的丝扣，以便找平、找正用，并用一个螺母固定",{"key":30,"text":149,"correct":32},"当通风（空调）系统有恒温、恒湿要求时，消声器设备外壳与风管同样应做处理",{"id":151,"libraryId":5,"type":40,"typeLabel":41,"stem":152,"options":153,"answer":30,"analysis":37},1265269,"火灾探测器至墙壁、梁边的水平距离不应小于（ ）。",[154,156,157,159],{"key":20,"text":155,"correct":32},"2",{"key":24,"text":73,"correct":32},{"key":27,"text":158,"correct":32},"1",{"key":30,"text":160,"correct":22},"0.5",{"id":162,"libraryId":5,"type":40,"typeLabel":41,"stem":163,"options":164,"answer":20,"analysis":37},1265270,"某安装公司中标了C市一大型写字楼机电安装工程，内容包含室内给水排水、电气照明、配电房、通风与空调系统、消防及智能化监控系统等。项目部在施工过程中严格遵守施工规范及验收标准，利用PDCA循环加强质量控制。项目最终验收合格，顺利投人使用。根据背景材料，回答以下问题。 通风与空调工程交工前，项目上进行了综合效能的测定与调整，应由（ ）负责实施。",[165,167,169,171],{"key":20,"text":166,"correct":22},"建设单位",{"key":24,"text":168,"correct":32},"设计单位",{"key":27,"text":170,"correct":32},"监理单位",{"key":30,"text":172,"correct":32},"施工单位",{"id":174,"libraryId":5,"type":40,"typeLabel":41,"stem":175,"options":176,"answer":27,"analysis":37},1265271,"矩形风管制作时，当边长大于或等于（ ）mm、管段大于1.2m时，均应采取加固措施。",[177,179,181,183],{"key":20,"text":178,"correct":32},"900",{"key":24,"text":180,"correct":32},"800",{"key":27,"text":182,"correct":22},"630",{"key":30,"text":184,"correct":32},"500",{"id":186,"libraryId":5,"type":40,"typeLabel":41,"stem":187,"options":188,"answer":20,"analysis":37},1265272,"冷热水管道上下平行安装时热水管道应在冷水管道（ ）。",[189,191,193,195],{"key":20,"text":190,"correct":22},"上方",{"key":24,"text":192,"correct":32},"下方",{"key":27,"text":194,"correct":32},"左侧",{"key":30,"text":196,"correct":32},"右侧",{"id":198,"libraryId":5,"type":40,"typeLabel":41,"stem":199,"options":200,"answer":30,"analysis":37},1265273,"室内给水与排水管道交叉铺设时，垂直净距不得小于（ ）。",[201,202,203,204],{"key":20,"text":155,"correct":32},{"key":24,"text":158,"correct":32},{"key":27,"text":160,"correct":32},{"key":30,"text":205,"correct":22},"0.15",{"id":207,"libraryId":5,"type":15,"typeLabel":16,"stem":208,"options":209,"answer":220,"analysis":37},1265274,"卫生器具安装完毕后应做的试验有（ ）。",[210,212,214,216,218],{"key":20,"text":211,"correct":32},"水压试验",{"key":24,"text":213,"correct":32},"真空试验",{"key":27,"text":215,"correct":22},"满水试验",{"key":30,"text":217,"correct":22},"通水试验",{"key":34,"text":219,"correct":32},"通球试验","CD",{"id":222,"libraryId":5,"type":40,"typeLabel":41,"stem":223,"options":224,"answer":24,"analysis":37},1265275,"耐火砖砌筑时，关于膨胀缝的留设，下列说法中正确的是（ ）。",[225,227,229,231],{"key":20,"text":226,"correct":32},"膨胀缝应该设在受力不均匀的地方",{"key":24,"text":228,"correct":22},"膨胀缝应避开砌体中的孔洞",{"key":27,"text":230,"correct":32},"砌体内外层的膨胀缝应相互贯通",{"key":30,"text":232,"correct":32},"膨胀缝上下层应相互重叠",{"id":234,"libraryId":5,"type":40,"typeLabel":41,"stem":235,"options":236,"answer":27,"analysis":37},1265276,"在二极管加反向电压时，会形成（ ）的反向电流，且反相电压不超过某一范围时，反向电流大小（ ）。",[237,239,241,243],{"key":20,"text":238,"correct":32},"很大基本不变",{"key":24,"text":240,"correct":32},"很大线性变化",{"key":27,"text":242,"correct":22},"很小基本不变",{"key":30,"text":244,"correct":32},"很小线性变化",{"id":246,"libraryId":5,"type":40,"typeLabel":41,"stem":247,"options":248,"answer":30,"analysis":37},1265277,"《注册建造师执业管理办法（试行）》规定，机电工程中，冶炼专业工程范围包括烧结球团工程、焦化工程、冶金工程、煤气工程、建材工程和（ ）工程。",[249,251,253,255],{"key":20,"text":250,"correct":32},"动力站安装",{"key":24,"text":252,"correct":32},"起重设备安装",{"key":27,"text":254,"correct":32},"工业炉窖安装",{"key":30,"text":256,"correct":22},"制氧",{"id":258,"libraryId":5,"type":40,"typeLabel":41,"stem":259,"options":260,"answer":24,"analysis":37},1265278,"下列选项中，不属于建筑管道工程系统试验的是（ ）。",[261,263,265,267],{"key":20,"text":262,"correct":32},"非承压管道灌水试验",{"key":24,"text":264,"correct":22},"承压管道气密性试验",{"key":27,"text":266,"correct":32},"排水于管通球试验",{"key":30,"text":268,"correct":32},"排水干管通水试验",{"id":270,"libraryId":5,"type":40,"typeLabel":41,"stem":271,"options":272,"answer":20,"analysis":37},1265279,"下列设备中，其纵、横向基准线及标高基准点应设置永久标点的是（。",[273,275,277,279],{"key":20,"text":274,"correct":22},"轧钢机",{"key":24,"text":276,"correct":32},"鼓风机",{"key":27,"text":278,"correct":32},"皮带输送机",{"key":30,"text":280,"correct":32},"桥式起重机",{"id":282,"libraryId":5,"type":40,"typeLabel":41,"stem":283,"options":284,"answer":20,"analysis":37},1265281,"承担压力容器产品焊接试板焊接的焊工，应由（ ）焊工来承担是最符合标准要求的。",[285,287,289,291],{"key":20,"text":286,"correct":22},"焊接产品的",{"key":24,"text":288,"correct":32},"本单位熟练的",{"key":27,"text":290,"correct":32},"持有压力容器相应位置焊接资格证的",{"key":30,"text":292,"correct":32},"持有压力容器焊接资格证的",{"id":294,"libraryId":5,"type":40,"typeLabel":41,"stem":295,"options":296,"answer":27,"analysis":37},1265282,"对电梯质量以及安全运行涉及的质量问题负责的单位是（ ）。",[297,299,301,303],{"key":20,"text":298,"correct":32},"电梯维修单位",{"key":24,"text":300,"correct":32},"电梯安装单位",{"key":27,"text":302,"correct":22},"电梯的制造单位",{"key":30,"text":304,"correct":32},"电梯设计单位",{"id":306,"libraryId":5,"type":40,"typeLabel":41,"stem":307,"options":308,"answer":30,"analysis":37},1265283,"结构简单、坚固耐用、运行可靠、维护方便、启动容易、成本低，但调速困难、功率因数偏低的电动机应是（ ）。",[309,311,313,315],{"key":20,"text":310,"correct":32},"同步电动机",{"key":24,"text":312,"correct":32},"直流电动机",{"key":27,"text":314,"correct":32},"单相电动机",{"key":30,"text":316,"correct":22},"异步电动机",{"id":318,"libraryId":5,"type":40,"typeLabel":41,"stem":319,"options":320,"answer":27,"analysis":37},1265284,"发电机转子穿装常用的方法不包括（ ）。",[321,323,325,327],{"key":20,"text":322,"correct":32},"滑道式方法",{"key":24,"text":324,"correct":32},"接轴的方法",{"key":27,"text":326,"correct":22},"螺旋式方法",{"key":30,"text":328,"correct":32},"用后轴承座作平衡重量的方法",{"id":330,"libraryId":5,"type":40,"typeLabel":41,"stem":331,"options":332,"answer":20,"analysis":37},1265285,"单相整流电路，功率一般为（ ），三相桥式整流电路的功率可达到（ ）。",[333,335,337,339],{"key":20,"text":334,"correct":22},"几瓦到几百瓦几千瓦以上",{"key":24,"text":336,"correct":32},"几千瓦以上几瓦到几百瓦",{"key":27,"text":338,"correct":32},"几瓦到几十瓦几百瓦以上",{"key":30,"text":340,"correct":32},"几百瓦以上几瓦到几十瓦",{"id":342,"libraryId":5,"type":40,"typeLabel":41,"stem":343,"options":344,"answer":27,"analysis":37},1265287,"三相交流发电机中三个绕组，当发电机极对数为1时，绕组在空间上间隔（ ），当发电机极对数为2时，绕组在空间上间隔（ ）。",[345,347,349,351],{"key":20,"text":346,"correct":32},"240°120°",{"key":24,"text":348,"correct":32},"120°240°",{"key":27,"text":350,"correct":22},"120°60°",{"key":30,"text":352,"correct":32},"60°120°",{"id":354,"libraryId":5,"type":40,"typeLabel":41,"stem":355,"options":356,"answer":24,"analysis":37},1265288,"交流电压1200V、直流电压1500V及以上的电器是。",[357,359,361,363],{"key":20,"text":358,"correct":32},"低压电器",{"key":24,"text":360,"correct":22},"高压电器",{"key":27,"text":362,"correct":32},"指示仪表",{"key":30,"text":364,"correct":32},"比较仪表",{"id":366,"libraryId":5,"type":40,"typeLabel":41,"stem":367,"options":368,"answer":30,"analysis":37},1265289,"利用建筑物外立面混凝土柱内的主钢筋作防雷引下线时，应在离地（ ）处做接地测试点。",[369,371,373,375],{"key":20,"text":370,"correct":32},"O.5m",{"key":24,"text":372,"correct":32},"1.0m",{"key":27,"text":374,"correct":32},"1.5m",{"key":30,"text":376,"correct":22},"1.8m",{"id":378,"libraryId":5,"type":40,"typeLabel":41,"stem":379,"options":380,"answer":20,"analysis":37},1265290,"碳素结构钢中的低碳钢，其含碳量小于。",[381,383,385,387],{"key":20,"text":382,"correct":22},"0.25%",{"key":24,"text":384,"correct":32},"0.35%",{"key":27,"text":386,"correct":32},"0.45%",{"key":30,"text":388,"correct":32},"0.60%",{"id":390,"libraryId":5,"type":40,"typeLabel":41,"stem":391,"options":392,"answer":27,"analysis":37},1265292,"下列方法中，不属于过盈配合件装配方法的是（ ）。",[393,395,397,399],{"key":20,"text":394,"correct":32},"压入装配法",{"key":24,"text":396,"correct":32},"低温冷装配法",{"key":27,"text":398,"correct":22},"焊接固定法",{"key":30,"text":400,"correct":32},"加热装pL4A",{"id":402,"libraryId":5,"type":40,"typeLabel":41,"stem":403,"options":404,"answer":20,"analysis":37},1265293,"下列因素中，属于变压器油的作用是（ ）。",[405,407,409,411],{"key":20,"text":406,"correct":22},"变压器冷却",{"key":24,"text":408,"correct":32},"变压器消弧",{"key":27,"text":410,"correct":32},"变压器润滑",{"key":30,"text":412,"correct":32},"变压器填补",{"id":414,"libraryId":5,"type":40,"typeLabel":41,"stem":415,"options":416,"answer":27,"analysis":37},1265295,"电缆接头的两侧绝缘垫间的耐压值，不得低于电缆保护层绝缘水平的。",[417,419,421,423],{"key":20,"text":418,"correct":32},"1.2倍",{"key":24,"text":420,"correct":32},"1.5倍",{"key":27,"text":422,"correct":22},"2.0倍",{"key":30,"text":424,"correct":32},"2.5倍",{"id":426,"libraryId":5,"type":40,"typeLabel":41,"stem":427,"options":428,"answer":30,"analysis":37},1265296,"特种设备安全监督管理部门的安全监察人员应当熟悉相关法律、法规、规章和安全技术规范，具有相应的专业知识和工作经验，并经（ ）考核，取得特种设备安全监察人员证书。",[429,431,433,435],{"key":20,"text":430,"correct":32},"国家注册资格",{"key":24,"text":432,"correct":32},"当地特种设备安全监督管理部门",{"key":27,"text":434,"correct":32},"省市级特种设备安全监督管理部门",{"key":30,"text":436,"correct":22},"国务院特种设备安全监督管理部门",{"id":438,"libraryId":5,"type":40,"typeLabel":41,"stem":439,"options":440,"answer":30,"analysis":37},1265297,"消防工程验收操作的指挥者是（ ）。",[441,442,443,444],{"key":20,"text":170,"correct":32},{"key":24,"text":166,"correct":32},{"key":27,"text":168,"correct":32},{"key":30,"text":445,"correct":22},"公安消防部门",{"id":447,"libraryId":5,"type":40,"typeLabel":41,"stem":448,"options":449,"answer":24,"analysis":37},1265298,"能够阻止外部环境的热流进入，减少冷量损失，维持保冷功能的保冷核心层是（ ）。",[450,452,454,456],{"key":20,"text":451,"correct":32},"防锈层",{"key":24,"text":453,"correct":22},"绝热层",{"key":27,"text":455,"correct":32},"防潮层",{"key":30,"text":457,"correct":32},"保护层",{"id":459,"libraryId":5,"type":40,"typeLabel":41,"stem":460,"options":461,"answer":27,"analysis":37},1265299,"在通风空调风管系统中，风管穿越建筑物变形缝空间时，应设置。",[462,464,466,468],{"key":20,"text":463,"correct":32},"支吊架",{"key":24,"text":465,"correct":32},"钢制套管",{"key":27,"text":467,"correct":22},"柔性短管",{"key":30,"text":469,"correct":32},"柔性防水材料",{"id":471,"libraryId":5,"type":40,"typeLabel":41,"stem":472,"options":473,"answer":27,"analysis":37},1265300,"下列中不属于特种设备“四方责任”的部门是。",[474,476,478,479],{"key":20,"text":475,"correct":32},"生产和使用单位",{"key":24,"text":477,"correct":32},"检验检测机构",{"key":27,"text":168,"correct":22},{"key":30,"text":480,"correct":32},"监督部门",{"id":482,"libraryId":5,"type":40,"typeLabel":41,"stem":483,"options":484,"answer":20,"analysis":37},1265301,"下列焊接工艺参数中，不属于埋弧自动焊工艺参数的是（ ）。",[485,487,489,491],{"key":20,"text":486,"correct":22},"焊条牌号",{"key":24,"text":488,"correct":32},"焊接电流",{"key":27,"text":490,"correct":32},"焊接速度",{"key":30,"text":492,"correct":32},"焊件的坡口形式",{"id":494,"libraryId":5,"type":40,"typeLabel":41,"stem":495,"options":496,"answer":27,"analysis":37},1265302,"下列材料中属于酸性耐火材料的是。",[497,499,501,503],{"key":20,"text":498,"correct":32},"镁铝砖",{"key":24,"text":500,"correct":32},"白云石砖",{"key":27,"text":502,"correct":22},"锆英砂砖",{"key":30,"text":504,"correct":32},"高铝砖",{"id":506,"libraryId":5,"type":40,"typeLabel":41,"stem":507,"options":508,"answer":24,"analysis":37},1265303,"压力管道按安装许可类别及其级别划分时，公用管道分为燃气管道和（ ）。",[509,511,513,515],{"key":20,"text":510,"correct":32},"供水管道",{"key":24,"text":512,"correct":22},"热力管道",{"key":27,"text":514,"correct":32},"污水管道",{"key":30,"text":516,"correct":32},"动力管道",{"id":518,"libraryId":5,"type":40,"typeLabel":41,"stem":519,"options":520,"answer":27,"analysis":37},1265304,"大型龙门起重机设备吊装，宜选用的吊装方法是（ ）。",[521,523,525,527],{"key":20,"text":522,"correct":32},"旋转吊装法",{"key":24,"text":524,"correct":32},"超高空斜承索吊运设备吊装法",{"key":27,"text":526,"correct":22},"集群液压千斤顶整体提升吊装法",{"key":30,"text":528,"correct":32},"气压顶升法",{"id":530,"libraryId":5,"type":40,"typeLabel":41,"stem":531,"options":532,"answer":20,"analysis":37},1265305,"水灭火系统包括消火栓灭火系统和（ ）。",[533,535,537,539],{"key":20,"text":534,"correct":22},"自动喷淋灭火系统",{"key":24,"text":536,"correct":32},"应急疏散系统",{"key":27,"text":538,"correct":32},"消防广播系统",{"key":30,"text":540,"correct":32},"通风系统",{"id":542,"libraryId":5,"type":40,"typeLabel":41,"stem":543,"options":544,"answer":20,"analysis":37},1265306,"不影响机械设备安装精度的因素是（ ）。",[545,547,549,551],{"key":20,"text":546,"correct":22},"设备制造",{"key":24,"text":548,"correct":32},"垫铁",{"key":27,"text":550,"correct":32},"二次灌浆",{"key":30,"text":552,"correct":32},"设备基础",{"id":554,"libraryId":5,"type":40,"typeLabel":41,"stem":555,"options":556,"answer":24,"analysis":37},1265307,"按照变更的内容，设计变更可分为（ ）。",[557,559,561,563],{"key":20,"text":558,"correct":32},"重大设计变更、较大设计变更、一般设计变更",{"key":24,"text":560,"correct":22},"重大设计变更、一般设计变更",{"key":27,"text":562,"correct":32},"特大设计变更、较大设计变更、一般设计变更",{"key":30,"text":564,"correct":32},"较大设计变更、一般设计变更",{"id":566,"libraryId":5,"type":40,"typeLabel":41,"stem":567,"options":568,"answer":24,"analysis":37},1265308,"洁净室及洁净区空气中悬浮粒子洁净度等级共划分为（ ）个等级。",[569,570,572,574],{"key":20,"text":59,"correct":32},{"key":24,"text":571,"correct":22},"9",{"key":27,"text":573,"correct":32},"10",{"key":30,"text":575,"correct":32},"12",{"id":577,"libraryId":5,"type":40,"typeLabel":41,"stem":578,"options":579,"answer":27,"analysis":37},1265309,"面接触型二极管，可通过（ ）电流，但其工作频率是（ ）的。",[580,582,584,586],{"key":20,"text":581,"correct":32},"较小低频",{"key":24,"text":583,"correct":32},"较小高频",{"key":27,"text":585,"correct":22},"较大低频",{"key":30,"text":587,"correct":32},"较大高频",{"id":589,"libraryId":5,"type":40,"typeLabel":41,"stem":590,"options":591,"answer":27,"analysis":37},1265310,"交接箱主要由（ ）、箱架结构和机箱组成。",[592,594,596,598],{"key":20,"text":593,"correct":32},"电源",{"key":24,"text":595,"correct":32},"处理器",{"key":27,"text":597,"correct":22},"接线模块",{"key":30,"text":599,"correct":32},"中继器",{"id":601,"libraryId":5,"type":40,"typeLabel":41,"stem":602,"options":603,"answer":20,"analysis":37},1265311,"如原边绕组N1的线圈数多于副边绕组N2的线圈数，则为（ ）变压器，反之则为（ ）变压器。",[604,606,608,610],{"key":20,"text":605,"correct":22},"降压升压",{"key":24,"text":607,"correct":32},"降压降压",{"key":27,"text":609,"correct":32},"升压升压",{"key":30,"text":611,"correct":32},"升压降压",{"id":613,"libraryId":5,"type":40,"typeLabel":41,"stem":614,"options":615,"answer":24,"analysis":37},1265312,"自动化仪表试验的30V直流电源电压波动不应超过。",[616,618,620,622],{"key":20,"text":617,"correct":32},"±2.5%",{"key":24,"text":619,"correct":22},"±5.0%",{"key":27,"text":621,"correct":32},"±7.5%",{"key":30,"text":623,"correct":32},"±10%",[625,628,631,634,637,640],{"id":40,"name":626,"category":7,"favorite":627},"领导干部任职前廉政法规知识测试题",92,{"id":629,"name":630,"category":7,"favorite":40},595,"建筑结构与设备",{"id":632,"name":633,"category":7,"favorite":40},715,"招标采购专业知识与法律法规",{"id":635,"name":636,"category":7,"favorite":40},848,"市政方向-通用基础",{"id":638,"name":639,"category":7,"favorite":8},534,"BIM工程师",{"id":641,"name":639,"category":7,"favorite":8},535]