[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-853-3":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":562},{"id":5,"name":6,"category":7,"favorite":8},853,"(设备安装质量)基础知识","建筑工程",0,3,50,1092,[13,38,52,61,76,90,102,117,129,135,147,162,174,186,200,212,226,240,252,266,278,290,302,314,326,338,348,356,366,375,387,398,410,419,431,443,455,467,473,479,485,491,497,503,509,515,521,527,533,547],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},1265209,2,"多选题","注意各类图上描述同一对象或同一内容的一致性，尤其是（ ）的一致性。",[19,23,26,29,33],{"key":20,"text":21,"correct":22},"A","型号",true,{"key":24,"text":25,"correct":22},"B","规格",{"key":27,"text":28,"correct":22},"C","数量",{"key":30,"text":31,"correct":32},"D","尺寸",false,{"key":34,"text":35,"correct":32},"E","大小","ABC","",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":36,"analysis":37},1265210,"建筑电气工程图包含（ ）。",[42,44,46,48,50],{"key":20,"text":43,"correct":22},"系统图",{"key":24,"text":45,"correct":22},"电路图",{"key":27,"text":47,"correct":22},"平面图",{"key":30,"text":49,"correct":32},"风管系统图",{"key":34,"text":51,"correct":32},"电气图",{"id":53,"libraryId":5,"type":9,"typeLabel":54,"stem":55,"options":56,"answer":58,"analysis":37},1265211,"判断题","图线的使用都有明确的规定，总的原则是剖切面的截交线和房屋立面图中的外轮廓线用粗实线，次要的轮廓线用中粗线，其他线一律用细线。再者，可见部分用实线，不可见部分用虚线。",[57,59],{"key":20,"text":58,"correct":22},"正确",{"key":24,"text":60,"correct":32},"错误",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":75,"analysis":37},1265212,"绘制系统测点用冲突要注意的事项（ ）。",[65,67,69,71,73],{"key":20,"text":66,"correct":22},"风机压出端的测定面要选在通风机出口而气流比较稳定的直管段上",{"key":24,"text":68,"correct":22},"测量矩形断面的测点划分面积不大于0.05㎡，控制边长在200mm～250mm间，最佳为小于220mm",{"key":27,"text":70,"correct":22},"量圆形断面的测点据管径大小将断面划分成若干个面积相同的同心环，每个圆环设四个测点，这四个点处于相互垂直的直径上",{"key":30,"text":72,"correct":22},"气流稳定的断面选择在产生局部阻力的弯头三通等部件引起的涡流的部位后顺气流方向圆形风管4～5倍直径或矩形风管大边长度尺寸处",{"key":34,"text":74,"correct":32},"测量矩形断面的测点划分面积不大于0.06㎡，控制边长在200mm～250mm间，最佳为小于220mm","ABCD",{"id":77,"libraryId":5,"type":78,"typeLabel":79,"stem":80,"options":81,"answer":20,"analysis":37},1265213,1,"单选题","临时用电设备在（ ）或设备总容量在（ ）者，应编制临时用电施工组织设计",[82,84,86,88],{"key":20,"text":83,"correct":22},"5台及5台以上50KW及50KW以上",{"key":24,"text":85,"correct":32},"4台及4台以上50KW及50KW以上",{"key":27,"text":87,"correct":32},"5台及5台以上40KW及40KW以上",{"key":30,"text":89,"correct":32},"6台及6台以上50KW及50KW以上",{"id":91,"libraryId":5,"type":78,"typeLabel":79,"stem":92,"options":93,"answer":20,"analysis":37},1265214,"阅读前要熟悉图例符号表达的内涵，要注意对照施工图的（ ），判断图例的图形是否符合预想的设想。",[94,96,98,100],{"key":20,"text":95,"correct":22},"设备材料表",{"key":24,"text":97,"correct":32},"标注的图例",{"key":27,"text":99,"correct":32},"标题栏",{"key":30,"text":101,"correct":32},"图例符号",{"id":103,"libraryId":5,"type":15,"typeLabel":16,"stem":104,"options":105,"answer":116,"analysis":37},1265215,"建筑剖面图表达的内容有（ ）。",[106,108,110,112,114],{"key":20,"text":107,"correct":22},"高度方面的情况",{"key":24,"text":109,"correct":22},"空间布置",{"key":27,"text":111,"correct":32},"设备安装方面",{"key":30,"text":113,"correct":22},"屋面的排水方向",{"key":34,"text":115,"correct":32},"各平面的绝对标高","ABD",{"id":118,"libraryId":5,"type":78,"typeLabel":79,"stem":119,"options":120,"answer":30,"analysis":37},1265216,"施工作业人员的义务（ ）。",[121,123,125,127],{"key":20,"text":122,"correct":32},"有权获得安全防护用具和安全防护服装",{"key":24,"text":124,"correct":32},"有权知晓危险岗位的操作规程和违章操作的危害",{"key":27,"text":126,"correct":32},"在施工中发生危及人身安全的紧急情况时，作业人员有权即停止作业或采取必要的应急措施后撤离危险区域",{"key":30,"text":128,"correct":22},"应当遵守安全施工的强制性标准",{"id":130,"libraryId":5,"type":9,"typeLabel":54,"stem":131,"options":132,"answer":60,"analysis":37},1265217,"用三视图阅读施工图的方法基本一样的，所以仅对管道和通风与空调工程特有的图例符号和轴测图等不需作出提示",[133,134],{"key":20,"text":58,"correct":32},{"key":24,"text":60,"correct":22},{"id":136,"libraryId":5,"type":78,"typeLabel":79,"stem":137,"options":138,"answer":24,"analysis":37},1265218,"给水排水工程中，图例 表达的含义是（ ）。",[139,141,143,145],{"key":20,"text":140,"correct":32},"异径管",{"key":24,"text":142,"correct":22},"偏心异径管",{"key":27,"text":144,"correct":32},"乙字管",{"key":30,"text":146,"correct":32},"转动接头",{"id":148,"libraryId":5,"type":15,"typeLabel":16,"stem":149,"options":150,"answer":161,"analysis":37},1265219,"施工现场双电源自动切换使用的注意的安全事项（ ）。",[151,153,155,157,159],{"key":20,"text":152,"correct":32},"正常电源和备用电源并联运行",{"key":24,"text":154,"correct":22},"正常电源和备用电源电压值保持在相同的水平",{"key":27,"text":156,"correct":22},"两者接入馈电线路时应严格保持相序一致",{"key":30,"text":158,"correct":32},"正常电源和备用电源能并联运行",{"key":34,"text":160,"correct":22},"正常电源和备用电源不能并联运行","BCE",{"id":163,"libraryId":5,"type":78,"typeLabel":79,"stem":164,"options":165,"answer":27,"analysis":37},1265220,"用倾斜的投影面以正投影法获得的投影图称为（ ）。",[166,168,170,172],{"key":20,"text":167,"correct":32},"正视图",{"key":24,"text":169,"correct":32},"剖视图",{"key":27,"text":171,"correct":22},"斜视图",{"key":30,"text":173,"correct":32},"仰视图",{"id":175,"libraryId":5,"type":78,"typeLabel":79,"stem":176,"options":177,"answer":30,"analysis":37},1265221,"建筑通风空调工程中，图例 表达的含义是（ ）。",[178,180,182,184],{"key":20,"text":179,"correct":32},"矩形三通",{"key":24,"text":181,"correct":32},"百叶窗",{"key":27,"text":183,"correct":32},"空气过滤器",{"key":30,"text":185,"correct":22},"方形散流器",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":75,"analysis":37},1265222,"给水排水工程图的识读步骤（ ）。",[190,192,194,196,198],{"key":20,"text":191,"correct":22},"图例符号阅读",{"key":24,"text":193,"correct":22},"轴测图阅读",{"key":27,"text":195,"correct":22},"识读施工图纸的基本方法",{"key":30,"text":197,"correct":22},"用三视图阅读施工图",{"key":34,"text":199,"correct":32},"图纸标志",{"id":201,"libraryId":5,"type":78,"typeLabel":79,"stem":202,"options":203,"answer":20,"analysis":37},1265223,"测量矩形断面的测点划分面积不大于（ ）㎡，控制边长在（ ）mm间，最佳为小于（ ）mm。",[204,206,208,210],{"key":20,"text":205,"correct":22},"0.05200～250220",{"key":24,"text":207,"correct":32},"0.03200～250200",{"key":27,"text":209,"correct":32},"0.03200～300220",{"key":30,"text":211,"correct":32},"0.05200～300200",{"id":213,"libraryId":5,"type":15,"typeLabel":16,"stem":214,"options":215,"answer":36,"analysis":37},1265224,"电子巡查系统的线路的形式有（ ）。",[216,218,220,222,224],{"key":20,"text":217,"correct":22},"在线巡查系统",{"key":24,"text":219,"correct":22},"离线巡查系统",{"key":27,"text":221,"correct":22},"复合巡查系统",{"key":30,"text":223,"correct":32},"自动报警系统",{"key":34,"text":225,"correct":32},"手动报警系统",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":75,"analysis":37},1265225,"建筑设备施工图绘制的步骤有（ ）。",[230,232,234,236,238],{"key":20,"text":231,"correct":22},"绘制建筑平面图",{"key":24,"text":233,"correct":22},"绘制卫生器具、散热设备、通风空调设备、电力设备、配电箱、开关、照明灯具、插座等设备部件的平面布置",{"key":27,"text":235,"correct":22},"绘制给水排水管道、供暖管道、空调管道系统，以及电气进户线、器具间的连接线",{"key":30,"text":237,"correct":22},"绘制有关图例，标注管径、标高、尺寸、编号，必要的附加文字标注及说明",{"key":34,"text":239,"correct":32},"确定轴测轴",{"id":241,"libraryId":5,"type":78,"typeLabel":79,"stem":242,"options":243,"answer":24,"analysis":37},1265226,"暖通空调专业施工图中，通风空调系统管道输送的介质一般为（ ）、水和蒸汽。",[244,246,248,250],{"key":20,"text":245,"correct":32},"中水",{"key":24,"text":247,"correct":22},"空气",{"key":27,"text":249,"correct":32},"燃油",{"key":30,"text":251,"correct":32},"天然气",{"id":253,"libraryId":5,"type":15,"typeLabel":16,"stem":254,"options":255,"answer":116,"analysis":37},1265227,"通风机的性能的主要指标包括（ ）。",[256,258,260,262,264],{"key":20,"text":257,"correct":22},"风压",{"key":24,"text":259,"correct":22},"风量",{"key":27,"text":261,"correct":32},"风速",{"key":30,"text":263,"correct":22},"转速",{"key":34,"text":265,"correct":32},"频率",{"id":267,"libraryId":5,"type":78,"typeLabel":79,"stem":268,"options":269,"answer":24,"analysis":37},1265228,"给水平面图识读时，应按（ ）分系统并分层识读。",[270,272,274,276],{"key":20,"text":271,"correct":32},"系统方向",{"key":24,"text":273,"correct":22},"供水方向",{"key":27,"text":275,"correct":32},"污水方向",{"key":30,"text":277,"correct":32},"冷却水方向",{"id":279,"libraryId":5,"type":78,"typeLabel":79,"stem":280,"options":281,"answer":30,"analysis":37},1265229,"自动监控系统的深化设计应具有开放结构，协议和接口都应（ ）。",[282,284,286,288],{"key":20,"text":283,"correct":32},"个性化",{"key":24,"text":285,"correct":32},"独立化",{"key":27,"text":287,"correct":32},"订制化",{"key":30,"text":289,"correct":22},"标准化",{"id":291,"libraryId":5,"type":78,"typeLabel":79,"stem":292,"options":293,"answer":20,"analysis":37},1265230,"大型建筑组合灯具每一单相回路电流不宜超过25 A，光源数量不宜超过（ ）个。",[294,296,298,300],{"key":20,"text":295,"correct":22},"60",{"key":24,"text":297,"correct":32},"50",{"key":27,"text":299,"correct":32},"35",{"key":30,"text":301,"correct":32},"25",{"id":303,"libraryId":5,"type":78,"typeLabel":79,"stem":304,"options":305,"answer":20,"analysis":37},1265231,"关于建筑设备监控系统中主要输入设备的安装，以下错误的是（ ）。",[306,308,310,312],{"key":20,"text":307,"correct":22},"风管型传感器安装应在风管保温层完成前进行",{"key":24,"text":309,"correct":32},"水管型传感器开孔与焊接工作，必须在管道的压力试验、清洗、防腐和保温前进行",{"key":27,"text":311,"correct":32},"电磁流量计应安装在流量调节阀的上游，流量计的上游应有10倍管径长度的直管段",{"key":30,"text":313,"correct":32},"涡轮式流量传感器应水平安装",{"id":315,"libraryId":5,"type":78,"typeLabel":79,"stem":316,"options":317,"answer":24,"analysis":37},1265232,"建筑设备监控系统与变配电设备、发电机组、冷水机组、热泵机组、锅炉和电梯等大型建筑设备实现接口方式的通信，必须预先约定所遵循的（ ）。",[318,320,322,324],{"key":20,"text":319,"correct":32},"采购方式",{"key":24,"text":321,"correct":22},"通信协议",{"key":27,"text":323,"correct":32},"调试程序",{"key":30,"text":325,"correct":32},"规格型号",{"id":327,"libraryId":5,"type":78,"typeLabel":79,"stem":328,"options":329,"answer":20,"analysis":37},1265233,"火灾自动报警系统中，从接线盒等处引到探测器底座、控制设备、扬声器的线路，当采用金属软管保护时，其长度不应大于（ ）。",[330,332,334,336],{"key":20,"text":331,"correct":22},"2",{"key":24,"text":333,"correct":32},"1.8",{"key":27,"text":335,"correct":32},"1.5",{"key":30,"text":337,"correct":32},"1.2",{"id":339,"libraryId":5,"type":78,"typeLabel":79,"stem":340,"options":341,"answer":27,"analysis":37},1265234,"消火栓安装，首先要以栓阀位置和标高定出消火栓支管出口位置，经核定消火栓栓口距地面高度为（ ）m，然后稳固消火栓箱。",[342,343,344,346],{"key":20,"text":335,"correct":32},{"key":24,"text":337,"correct":32},{"key":27,"text":345,"correct":22},"1.1",{"key":30,"text":347,"correct":32},"1.0",{"id":349,"libraryId":5,"type":78,"typeLabel":79,"stem":350,"options":351,"answer":30,"analysis":37},1265235,"照明配电箱内每一单相分支回路的电流不宜超过16 A，灯具数量不宜超过（ ）个。",[352,353,354,355],{"key":20,"text":295,"correct":32},{"key":24,"text":297,"correct":32},{"key":27,"text":299,"correct":32},{"key":30,"text":301,"correct":22},{"id":357,"libraryId":5,"type":78,"typeLabel":79,"stem":358,"options":359,"answer":27,"analysis":37},1265236,"排水栓及地漏的安装应平正、牢固，地漏的水封高度不得小于（ ）mm。",[360,362,364,365],{"key":20,"text":361,"correct":32},"100",{"key":24,"text":363,"correct":32},"80",{"key":27,"text":297,"correct":22},{"key":30,"text":301,"correct":32},{"id":367,"libraryId":5,"type":78,"typeLabel":79,"stem":368,"options":369,"answer":27,"analysis":37},1265237,"开关安装的位置应便于操作，开关距地面高度宜为（ ）m。",[370,371,372,374],{"key":20,"text":333,"correct":32},{"key":24,"text":335,"correct":32},{"key":27,"text":373,"correct":22},"1.3",{"key":30,"text":337,"correct":32},{"id":376,"libraryId":5,"type":78,"typeLabel":79,"stem":377,"options":378,"answer":24,"analysis":37},1265238,"安装风口时，应注意风口与房间的顶线和腰线协调一致。风管暗装时，风口应服从房间的线条。吸顶安装的散流器应（ ）。",[379,381,383,385],{"key":20,"text":380,"correct":32},"高于顶面1cm",{"key":24,"text":382,"correct":22},"与顶面平齐",{"key":27,"text":384,"correct":32},"低于顶面1cm",{"key":30,"text":386,"correct":32},"低于顶面2cm",{"id":388,"libraryId":5,"type":78,"typeLabel":79,"stem":389,"options":390,"answer":27,"analysis":37},1265239,"安防系统中主要设备的检测.应采用随机抽样法进行抽样；.抽样率不应低于20%且不应少于（ ）台。",[391,393,395,397],{"key":20,"text":392,"correct":32},"5",{"key":24,"text":394,"correct":32},"4",{"key":27,"text":396,"correct":22},"3",{"key":30,"text":331,"correct":32},{"id":399,"libraryId":5,"type":78,"typeLabel":79,"stem":400,"options":401,"answer":24,"analysis":37},1265240,"电力电缆在桥架内敷设时，电力电缆的总截面积不应大于桥架横断面的（ ）。",[402,404,406,408],{"key":20,"text":403,"correct":32},"80％",{"key":24,"text":405,"correct":22},"60％",{"key":27,"text":407,"correct":32},"50％",{"key":30,"text":409,"correct":32},"40％",{"id":411,"libraryId":5,"type":78,"typeLabel":79,"stem":412,"options":413,"answer":30,"analysis":37},1265241,"直埋电缆应使用铠装电缆，铠装电缆的金属外皮两端要可靠接地，接地电阻不得大于100，埋深应不小于（ ）。",[414,415,416,417],{"key":20,"text":373,"correct":32},{"key":24,"text":345,"correct":32},{"key":27,"text":347,"correct":32},{"key":30,"text":418,"correct":22},"0.7",{"id":420,"libraryId":5,"type":78,"typeLabel":79,"stem":421,"options":422,"answer":20,"analysis":37},1265242,"保冷结构的组成，以下由内至外顺序正确的是（ ）。",[423,425,427,429],{"key":20,"text":424,"correct":22},"防锈层、保冷层、防潮层、保护层、防腐蚀及识别层",{"key":24,"text":426,"correct":32},"防锈层、防潮层、保冷层、保护层、防腐蚀及识别层",{"key":27,"text":428,"correct":32},"保冷层、防潮层、防锈层、保护层、防腐蚀及识别层",{"key":30,"text":430,"correct":32},"防锈层、保冷层、保护层、防潮层、防腐蚀及识别层",{"id":432,"libraryId":5,"type":78,"typeLabel":79,"stem":433,"options":434,"answer":20,"analysis":37},1265243,"净化空调系统中，矩形风管边长小于或等于（ ）mm时，底面板不得采用拼接。",[435,437,439,441],{"key":20,"text":436,"correct":22},"900",{"key":24,"text":438,"correct":32},"800",{"key":27,"text":440,"correct":32},"630",{"key":30,"text":442,"correct":32},"500",{"id":444,"libraryId":5,"type":78,"typeLabel":79,"stem":445,"options":446,"answer":24,"analysis":37},1265244,"探测器宜水平安装，当必须倾斜安装时，倾斜角不应大于（ ）。",[447,449,451,453],{"key":20,"text":448,"correct":32},"60°",{"key":24,"text":450,"correct":22},"45°",{"key":27,"text":452,"correct":32},"30°",{"key":30,"text":454,"correct":32},"15°",{"id":456,"libraryId":5,"type":78,"typeLabel":79,"stem":457,"options":458,"answer":27,"analysis":37},1265245,"在宽度小于3m的内走道顶棚上设置探测器时，宜（ ）布置。",[459,461,463,465],{"key":20,"text":460,"correct":32},"靠左",{"key":24,"text":462,"correct":32},"靠右",{"key":27,"text":464,"correct":22},"居中",{"key":30,"text":466,"correct":32},"分散",{"id":468,"libraryId":5,"type":9,"typeLabel":54,"stem":469,"options":470,"answer":58,"analysis":37},1265246,"建筑设备自动监控工程实施界面的确定贯彻于设备选型、系统设计、工程施工、检测验收的全过程中。",[471,472],{"key":20,"text":58,"correct":22},{"key":24,"text":60,"correct":32},{"id":474,"libraryId":5,"type":9,"typeLabel":54,"stem":475,"options":476,"answer":58,"analysis":37},1265247,"当灯具距地面高度小于2。4m时，灯具的金属外壳需要接地或接零，应采用单独的接地线（黄绿双色）接到保护接地（接零）线上。",[477,478],{"key":20,"text":58,"correct":22},{"key":24,"text":60,"correct":32},{"id":480,"libraryId":5,"type":9,"typeLabel":54,"stem":481,"options":482,"answer":58,"analysis":37},1265248,"卫生器具除浴盆和蹲式大便器外，均应待土建抹灰、粉刷、贴瓷砖等工作基本完成后再进行安装。",[483,484],{"key":20,"text":58,"correct":22},{"key":24,"text":60,"correct":32},{"id":486,"libraryId":5,"type":9,"typeLabel":54,"stem":487,"options":488,"answer":58,"analysis":37},1265249,"火灾自动报警线应穿人金属管内或金属线槽中，严禁与动力、照明、交流线、视频线或广播线等穿人同一线管内。",[489,490],{"key":20,"text":58,"correct":22},{"key":24,"text":60,"correct":32},{"id":492,"libraryId":5,"type":9,"typeLabel":54,"stem":493,"options":494,"answer":58,"analysis":37},1265250,"消防控制室内的进出电源线、控制线或控制电缆宜在地沟内敷设，垂直引上引下的线路应采用竖井或封闭式线槽内敷设。",[495,496],{"key":20,"text":58,"correct":22},{"key":24,"text":60,"correct":32},{"id":498,"libraryId":5,"type":9,"typeLabel":54,"stem":499,"options":500,"answer":60,"analysis":37},1265251,"给水管应铺在排水管上面，若给水管必须铺在排水管的下面时，给水管应加套管，其长度不得小于排水管管径的5倍。",[501,502],{"key":20,"text":58,"correct":32},{"key":24,"text":60,"correct":22},{"id":504,"libraryId":5,"type":9,"typeLabel":54,"stem":505,"options":506,"answer":58,"analysis":37},1265252,"照明配电箱内的交流、直流或不同等级的电源，应有明显的标志，且应有编号。照明配电箱内应标明用电回路名称。",[507,508],{"key":20,"text":58,"correct":22},{"key":24,"text":60,"correct":32},{"id":510,"libraryId":5,"type":9,"typeLabel":54,"stem":511,"options":512,"answer":58,"analysis":37},1265253,"刷涂是传统、简单的手工涂装方法，操作方便、灵活，可涂装任何形状的物件，可使涂料渗透金属表面的细孔，加强涂膜对金属的附着力；但刷涂劳动强度大，工作效率低，涂布外观欠佳。",[513,514],{"key":20,"text":58,"correct":22},{"key":24,"text":60,"correct":32},{"id":516,"libraryId":5,"type":9,"typeLabel":54,"stem":517,"options":518,"answer":60,"analysis":37},1265254,"安全防范工程的检测，应在系统试运行前进行。",[519,520],{"key":20,"text":58,"correct":32},{"key":24,"text":60,"correct":22},{"id":522,"libraryId":5,"type":9,"typeLabel":54,"stem":523,"options":524,"answer":60,"analysis":37},1265255,"在潮湿场所，应采用密封良好的防水、防溅插座，安装高度不应低于1.8m。",[525,526],{"key":20,"text":58,"correct":32},{"key":24,"text":60,"correct":22},{"id":528,"libraryId":5,"type":9,"typeLabel":54,"stem":529,"options":530,"answer":60,"analysis":37},1265256,"高效空气过滤器应在洁净室（区）建筑装饰装修和配管工程施工已完成并验收合格，洁净室（区）已进行全面清洁、擦净，净化空调系统已进行擦净和连续试运转8h以上才能安装。",[531,532],{"key":20,"text":58,"correct":32},{"key":24,"text":60,"correct":22},{"id":534,"libraryId":5,"type":15,"typeLabel":16,"stem":535,"options":536,"answer":75,"analysis":37},1265257,"喷射或抛射除锈过的钢材表面，除锈等级一般有（ ）。",[537,539,541,543,545],{"key":20,"text":538,"correct":22},"Sa1",{"key":24,"text":540,"correct":22},"Sa2",{"key":27,"text":542,"correct":22},"Sa2.5",{"key":30,"text":544,"correct":22},"Sa3",{"key":34,"text":546,"correct":32},"Sa4",{"id":548,"libraryId":5,"type":15,"typeLabel":16,"stem":549,"options":550,"answer":561,"analysis":37},1265258,"关于插座的安装，以下正确的有（ ）。",[551,553,555,557,559],{"key":20,"text":552,"correct":22},"插座宜单独的回路配电，而一个房间内的插座宜由同一回路配电",{"key":24,"text":554,"correct":22},"插座距地面高度一般为0.3m，托儿所、幼儿园及小学校的插座距地面高度不宜小于1.8m",{"key":27,"text":556,"correct":32},"单相三孔插座，面对插座板，右孔与零线连接，左孔与相线连接，上孔与接地线或零线连接",{"key":30,"text":558,"correct":22},"当交流、直流或不同电压等级的插座安装在同一场所时，应有明显的区别，必须选择不同结构、不同规格和不能互换的插座",{"key":34,"text":560,"correct":22},"在潮湿场所，应采用密封良好的防水、防溅插座，安装高度不应低于1.5m","ABDE",[563,566,569,572,575,578],{"id":78,"name":564,"category":7,"favorite":565},"领导干部任职前廉政法规知识测试题",92,{"id":567,"name":568,"category":7,"favorite":78},595,"建筑结构与设备",{"id":570,"name":571,"category":7,"favorite":78},715,"招标采购专业知识与法律法规",{"id":573,"name":574,"category":7,"favorite":78},848,"市政方向-通用基础",{"id":576,"name":577,"category":7,"favorite":8},534,"BIM工程师",{"id":579,"name":577,"category":7,"favorite":8},535]