[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-846-3":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":575},{"id":5,"name":6,"category":7,"favorite":8},846,"设备方向-通用基础","建筑工程",0,3,50,512,[13,34,46,54,66,78,90,99,111,123,135,147,159,170,179,188,199,211,223,233,245,253,265,277,289,301,313,325,337,349,360,372,382,394,402,414,423,433,442,454,463,475,483,491,503,515,527,539,551,563],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},1262370,1,"单选题","相邻不同级别洁净室之间和非洁净室之间的静压差不应小于( )Pa。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","3",false,{"key":24,"text":25,"correct":22},"B","5",{"key":27,"text":28,"correct":22},"C","8",{"key":30,"text":31,"correct":32},"D","10",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":27,"analysis":33},1262371,"系统平衡调整后,各空调机组的水流量应符合设计要求,允许偏差为( )。",[38,40,42,44],{"key":20,"text":39,"correct":22},"10%",{"key":24,"text":41,"correct":22},"15%",{"key":27,"text":43,"correct":32},"20%",{"key":30,"text":45,"correct":22},"25%",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},1262372,"对阀门强度试验时,试验压力为公称压力的1.5倍,持续时间不少于( )min,阀门的壳体、填料应无渗漏。",[50,51,52,53],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":32},{"key":27,"text":28,"correct":22},{"key":30,"text":31,"correct":22},{"id":55,"libraryId":5,"type":15,"typeLabel":16,"stem":56,"options":57,"answer":24,"analysis":33},1262373,"对阀门强度试验时,试验压力为公称压力的( )倍。",[58,60,62,64],{"key":20,"text":59,"correct":22},"1.0",{"key":24,"text":61,"correct":32},"1.5",{"key":27,"text":63,"correct":22},"2.0",{"key":30,"text":65,"correct":22},"2.5",{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":24,"analysis":33},1262374,"管道与设备的连接应在设备安装完毕后进行,与风管、制冷机组的连接须( )。",[70,72,74,76],{"key":20,"text":71,"correct":22},"采取刚性连接",{"key":24,"text":73,"correct":32},"采取柔性连接",{"key":27,"text":75,"correct":22},"强行对口连接",{"key":30,"text":77,"correct":22},"置于套管内连接",{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":30,"analysis":33},1262375,"制冷剂阀门安装前应进行严密性试验,严密性试验压力为阀门公称压力的1.1倍,持续时间( )s不漏为合格。",[82,84,86,88],{"key":20,"text":83,"correct":22},"15",{"key":24,"text":85,"correct":22},"20",{"key":27,"text":87,"correct":22},"25",{"key":30,"text":89,"correct":32},"30",{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":24,"analysis":33},1262376,"有两根以上的支管从干管引出时,连接部位应错开,间距不应小于2倍支管直径,且不小于( )mm。",[94,95,96,97],{"key":20,"text":31,"correct":22},{"key":24,"text":85,"correct":32},{"key":27,"text":89,"correct":22},{"key":30,"text":98,"correct":22},"40",{"id":100,"libraryId":5,"type":15,"typeLabel":16,"stem":101,"options":102,"answer":24,"analysis":33},1262377,"高效过滤器采用机械密封时,须采用密封胶,其厚度为( )mm。",[103,105,107,109],{"key":20,"text":104,"correct":22},"4～6",{"key":24,"text":106,"correct":32},"6～8",{"key":27,"text":108,"correct":22},"8～10",{"key":30,"text":110,"correct":22},"10～12",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":24,"analysis":33},1262378,"风机传动装置外露部位及直通大气的进出口必须装设( )。",[115,117,119,121],{"key":20,"text":116,"correct":22},"隔振器",{"key":24,"text":118,"correct":32},"防护罩",{"key":27,"text":120,"correct":22},"支架",{"key":30,"text":122,"correct":22},"金属套管",{"id":124,"libraryId":5,"type":15,"typeLabel":16,"stem":125,"options":126,"answer":24,"analysis":33},1262379,"在风管穿过需要封闭的防火、防爆的墙体或楼板时,应( )。",[127,129,131,133],{"key":20,"text":128,"correct":22},"增加管壁厚度不应小于1.2mm",{"key":24,"text":130,"correct":32},"设预埋管或防护套管",{"key":27,"text":132,"correct":22},"采用耐热不燃的材料替换",{"key":30,"text":134,"correct":22},"控制离地高度",{"id":136,"libraryId":5,"type":15,"typeLabel":16,"stem":137,"options":138,"answer":30,"analysis":33},1262380,"保温风管不能直接与支、吊架托架接触,应垫上坚固的隔热材料,其厚度与保温层相同,防止产生( )。",[139,141,143,145],{"key":20,"text":140,"correct":22},"锈蚀",{"key":24,"text":142,"correct":22},"污染",{"key":27,"text":144,"correct":22},"热桥",{"key":30,"text":146,"correct":32},"冷桥",{"id":148,"libraryId":5,"type":15,"typeLabel":16,"stem":149,"options":150,"answer":24,"analysis":33},1262381,"矩形风管立面与吊杆的间距不宜大于( )mm。",[151,153,155,157],{"key":20,"text":152,"correct":22},"100",{"key":24,"text":154,"correct":32},"150",{"key":27,"text":156,"correct":22},"200",{"key":30,"text":158,"correct":22},"250",{"id":160,"libraryId":5,"type":15,"typeLabel":16,"stem":161,"options":162,"answer":20,"analysis":33},1262382,"防火分区隔墙两侧的防火阀距墙体表面不应大于( )mm。",[163,164,166,168],{"key":20,"text":156,"correct":32},{"key":24,"text":165,"correct":22},"300",{"key":27,"text":167,"correct":22},"400",{"key":30,"text":169,"correct":22},"500",{"id":171,"libraryId":5,"type":15,"typeLabel":16,"stem":172,"options":173,"answer":20,"analysis":33},1262383,"金属风管的连接应平直、不扭曲,明装风管水平安装,水平度总偏差不应大于( )mm。",[174,175,177,178],{"key":20,"text":85,"correct":32},{"key":24,"text":176,"correct":22},"35",{"key":27,"text":89,"correct":22},{"key":30,"text":176,"correct":22},{"id":180,"libraryId":5,"type":15,"typeLabel":16,"stem":181,"options":182,"answer":24,"analysis":33},1262384,"风管的强度应能满足在( )倍工作压力下接缝处无开裂。",[183,184,185,186],{"key":20,"text":59,"correct":22},{"key":24,"text":61,"correct":32},{"key":27,"text":63,"correct":22},{"key":30,"text":187,"correct":22},"3.0",{"id":189,"libraryId":5,"type":15,"typeLabel":16,"stem":190,"options":191,"answer":27,"analysis":33},1262385,"当系统洁净度的等级为6～9级时,风管的法兰铆钉孔的间距不应大于( )mm。",[192,194,196,197],{"key":20,"text":193,"correct":22},"65",{"key":24,"text":195,"correct":22},"85",{"key":27,"text":152,"correct":32},{"key":30,"text":198,"correct":22},"115",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":30,"analysis":33},1262386,"支架的悬臂、吊架的横担采用( )制作。",[203,205,207,209],{"key":20,"text":204,"correct":22},"圆钢",{"key":24,"text":206,"correct":22},"圆钢和扁钢",{"key":27,"text":208,"correct":22},"扁钢",{"key":30,"text":210,"correct":32},"角钢或槽钢",{"id":212,"libraryId":5,"type":15,"typeLabel":16,"stem":213,"options":214,"answer":27,"analysis":33},1262387,"帆布柔性短管需要防潮时采取的措施是( )。",[215,217,219,221],{"key":20,"text":216,"correct":22},"涂刷油漆",{"key":24,"text":218,"correct":22},"涂刷防锈漆",{"key":27,"text":220,"correct":32},"涂刷帆布漆",{"key":30,"text":222,"correct":22},"镀锌",{"id":224,"libraryId":5,"type":15,"typeLabel":16,"stem":225,"options":226,"answer":24,"analysis":33},1262388,"风管的外径或外边尺寸的允许偏差为( )mm。",[227,229,230,232],{"key":20,"text":228,"correct":22},"2",{"key":24,"text":21,"correct":32},{"key":27,"text":231,"correct":22},"4",{"key":30,"text":25,"correct":22},{"id":234,"libraryId":5,"type":15,"typeLabel":16,"stem":235,"options":236,"answer":20,"analysis":33},1262389,"复合材料风管的覆面材料必须为( )。",[237,239,241,243],{"key":20,"text":238,"correct":32},"不燃材料",{"key":24,"text":240,"correct":22},"难燃材料",{"key":27,"text":242,"correct":22},"绝缘材料",{"key":30,"text":244,"correct":22},"塑性材料",{"id":246,"libraryId":5,"type":15,"typeLabel":16,"stem":247,"options":248,"answer":27,"analysis":33},1262390,"防火软接采用硅橡胶涂覆玻纤布为软接材料,用高温线缝制而成,最高耐温可达( )度。",[249,250,251,252],{"key":20,"text":156,"correct":22},{"key":24,"text":165,"correct":22},{"key":27,"text":167,"correct":32},{"key":30,"text":169,"correct":22},{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":30,"analysis":33},1262391,"室内采暖施工图中室内供暖系统字母代号为( )。",[257,259,261,263],{"key":20,"text":258,"correct":22},"L",{"key":24,"text":260,"correct":22},"R",{"key":27,"text":262,"correct":22},"P",{"key":30,"text":264,"correct":32},"N",{"id":266,"libraryId":5,"type":15,"typeLabel":16,"stem":267,"options":268,"answer":20,"analysis":33},1262392,"圆形风管所注标高应表示( )。",[269,271,273,275],{"key":20,"text":270,"correct":32},"管中心标高",{"key":24,"text":272,"correct":22},"管底标高",{"key":27,"text":274,"correct":22},"管顶标高",{"key":30,"text":276,"correct":22},"相对标高",{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":30,"analysis":33},1262393,"VRV系统是( )的简称。",[281,283,285,287],{"key":20,"text":282,"correct":22},"集中式单风管空调系统",{"key":24,"text":284,"correct":22},"集中式双风管空调系统",{"key":27,"text":286,"correct":22},"风机盘管式空调系统",{"key":30,"text":288,"correct":32},"可变冷媒流量空调系统",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":30,"analysis":33},1262394,"辐射供冷、供热空调系统是利用( )作为空调系统的冷、热源。",[293,295,297,299],{"key":20,"text":294,"correct":22},"高温热水或低温冷水",{"key":24,"text":296,"correct":22},"高温热水或高温冷水",{"key":27,"text":298,"correct":22},"低温热水或低温冷水",{"key":30,"text":300,"correct":32},"低温热水或高温冷水",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":24,"analysis":33},1262395,"以下不属于空调系统的构成的是( )。",[305,307,309,311],{"key":20,"text":306,"correct":22},"空气处理系统",{"key":24,"text":308,"correct":32},"送风排风系统",{"key":27,"text":310,"correct":22},"冷热源系统",{"key":30,"text":312,"correct":22},"能量输送分配系统",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":20,"analysis":33},1262396,"机械通风根据通风系统的作用范围不同,机械通风可划分为( )。",[317,319,321,323],{"key":20,"text":318,"correct":32},"局部通风和全面通风",{"key":24,"text":320,"correct":22},"自然通风和人工通风",{"key":27,"text":322,"correct":22},"局部通风和自然通风",{"key":30,"text":324,"correct":22},"人工通风和全面通风",{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":27,"analysis":33},1262397,"防雷接地系统中的避雷针、网、带的连接一般采用搭接焊，其焊接长度满足要求的是( )。",[329,331,333,335],{"key":20,"text":330,"correct":22},"圆钢与扁钢连接时，其长度为圆钢直径的5倍",{"key":24,"text":332,"correct":22},"扁钢为其宽度的3倍，两面施焊",{"key":27,"text":334,"correct":32},"扁钢为其宽度的2倍，三面施焊",{"key":30,"text":336,"correct":22},"圆钢为其长度的6倍，三面施焊",{"id":338,"libraryId":5,"type":15,"typeLabel":16,"stem":339,"options":340,"answer":24,"analysis":33},1262398,"避雷针一般选用镀锌圆钢或钢管加工而成,针长( )。",[341,343,345,347],{"key":20,"text":342,"correct":22},"1m以下",{"key":24,"text":344,"correct":32},"1～2m",{"key":27,"text":346,"correct":22},"2～3m",{"key":30,"text":348,"correct":22},"2m以上",{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":20,"analysis":33},1262399,"检查电动机绕组和控制线路的绝缘电阻应不低于( )MΩ。",[353,355,357,359],{"key":20,"text":354,"correct":32},"0.5",{"key":24,"text":356,"correct":22},"0.7",{"key":27,"text":358,"correct":22},"0.9",{"key":30,"text":59,"correct":22},{"id":361,"libraryId":5,"type":15,"typeLabel":16,"stem":362,"options":363,"answer":27,"analysis":33},1262400,"如果电动机出厂日期超过了制造厂保证期限,或经检查后有可疑时应进行( )。",[364,366,368,370],{"key":20,"text":365,"correct":22},"拆开接线盒",{"key":24,"text":367,"correct":22},"检验绝缘电阻值",{"key":27,"text":369,"correct":32},"抽芯检查",{"key":30,"text":371,"correct":22},"外观检查",{"id":373,"libraryId":5,"type":15,"typeLabel":16,"stem":374,"options":375,"answer":27,"analysis":33},1262401,"照明全负荷通电试运行时,民用住宅照明系统通电连续运行时间为( )h。",[376,378,380,381],{"key":20,"text":377,"correct":22},"24",{"key":24,"text":379,"correct":22},"12",{"key":27,"text":28,"correct":32},{"key":30,"text":231,"correct":22},{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":24,"analysis":33},1262402,"开关安装位置应便于操作,开关边缘距门框边缘距离( )m。",[386,388,390,392],{"key":20,"text":387,"correct":22},"0.10～0.15",{"key":24,"text":389,"correct":32},"0.15～0.20",{"key":27,"text":391,"correct":22},"0.20～0.25",{"key":30,"text":393,"correct":22},"0.25～0.30",{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":396,"options":397,"answer":30,"analysis":33},1262403,"大型花灯的固定及悬吊装置,应按灯具重量的( )倍做过载试验,以达到安全使用的目的。",[398,399,400,401],{"key":20,"text":61,"correct":22},{"key":24,"text":228,"correct":22},{"key":27,"text":21,"correct":22},{"key":30,"text":25,"correct":32},{"id":403,"libraryId":5,"type":15,"typeLabel":16,"stem":404,"options":405,"answer":27,"analysis":33},1262404,"对安装在顶棚装饰材料上的灯具,若灯泡距顶棚或木台太近,且顶棚为易燃材料时,应在灯具底座与顶棚间或灯泡与木台间放置( )。",[406,408,410,412],{"key":20,"text":407,"correct":22},"绝缘子",{"key":24,"text":409,"correct":22},"熔断器",{"key":27,"text":411,"correct":32},"隔热垫",{"key":30,"text":413,"correct":22},"防水垫",{"id":415,"libraryId":5,"type":15,"typeLabel":16,"stem":416,"options":417,"answer":30,"analysis":33},1262405,"照明灯具使用的导线其电压等级不应低于交流( )V,其最小线芯截面应符合规定,接线端子光洁、无锈蚀等现象。",[418,420,421,422],{"key":20,"text":419,"correct":22},"220",{"key":24,"text":165,"correct":22},{"key":27,"text":167,"correct":22},{"key":30,"text":169,"correct":32},{"id":424,"libraryId":5,"type":15,"typeLabel":16,"stem":425,"options":426,"answer":30,"analysis":33},1262406,"软线吊灯灯具重量不大于( )kg,",[427,428,430,432],{"key":20,"text":59,"correct":22},{"key":24,"text":429,"correct":22},"0.1",{"key":27,"text":431,"correct":22},"0.2",{"key":30,"text":354,"correct":32},{"id":434,"libraryId":5,"type":15,"typeLabel":16,"stem":435,"options":436,"answer":24,"analysis":33},1262407,"灯具安装时其质量大于( )kg,必须固定在螺栓或预埋吊钩上。",[437,438,439,440],{"key":20,"text":228,"correct":22},{"key":24,"text":21,"correct":32},{"key":27,"text":231,"correct":22},{"key":30,"text":441,"correct":22},"4.5",{"id":443,"libraryId":5,"type":15,"typeLabel":16,"stem":444,"options":445,"answer":30,"analysis":33},1262408,"室内灯具的安装方式主要有( )。",[446,448,450,452],{"key":20,"text":447,"correct":22},"吸顶式、嵌入式、挂式、悬吊式",{"key":24,"text":449,"correct":22},"落地式、吸顶式、吸壁式、悬吊式",{"key":27,"text":451,"correct":22},"吸顶式、嵌入式、挂式、落地式",{"key":30,"text":453,"correct":32},"吸顶式、嵌入式、吸壁式、悬吊式",{"id":455,"libraryId":5,"type":15,"typeLabel":16,"stem":456,"options":457,"answer":30,"analysis":33},1262409,"嵌入式配电箱全部电器安装完毕后,用( )伏兆欧表对线路进行绝缘检测。",[458,459,460,462],{"key":20,"text":419,"correct":22},{"key":24,"text":165,"correct":22},{"key":27,"text":461,"correct":22},"450",{"key":30,"text":169,"correct":32},{"id":464,"libraryId":5,"type":15,"typeLabel":16,"stem":465,"options":466,"answer":24,"analysis":33},1262410,"配电箱的安装高度以设计为准,箱体安装应保持水平和垂直,安装的垂直度允许偏差为( )。",[467,469,471,473],{"key":20,"text":468,"correct":22},"1.0‰",{"key":24,"text":470,"correct":32},"1.5‰",{"key":27,"text":472,"correct":22},"2.0‰",{"key":30,"text":474,"correct":22},"2.5‰",{"id":476,"libraryId":5,"type":15,"typeLabel":16,"stem":477,"options":478,"answer":20,"analysis":33},1262411,"在同一建筑物内同类配电箱的高度应保持一致,允许偏差为( )mm。",[479,480,481,482],{"key":20,"text":31,"correct":32},{"key":24,"text":83,"correct":22},{"key":27,"text":85,"correct":22},{"key":30,"text":87,"correct":22},{"id":484,"libraryId":5,"type":15,"typeLabel":16,"stem":485,"options":486,"answer":27,"analysis":33},1262412,"电线穿墙时应装过墙管保护,过墙管两端伸出墙面不小于( )mm。",[487,488,489,490],{"key":20,"text":25,"correct":22},{"key":24,"text":28,"correct":22},{"key":27,"text":31,"correct":32},{"key":30,"text":83,"correct":22},{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":30,"analysis":33},1262413,"以下电缆敷设程序错误的是( )。",[495,497,499,501],{"key":20,"text":496,"correct":22},"先敷设集中排列的电缆,后敷设分散排列的电缆",{"key":24,"text":498,"correct":22},"先敷设长电缆,后敷设短电缆",{"key":27,"text":500,"correct":22},"并列敷设的电缆先内后外",{"key":30,"text":502,"correct":32},"上下敷设的电缆先上后下",{"id":504,"libraryId":5,"type":15,"typeLabel":16,"stem":505,"options":506,"answer":27,"analysis":33},1262414,"电缆施放前应根据电缆总体布置情况,按施工实际( ),并把电缆按实际长度通盘计划,避免浪费。",[507,509,511,513],{"key":20,"text":508,"correct":22},"人力拖放电缆",{"key":24,"text":510,"correct":22},"采用电缆输送机,降低劳动强度",{"key":27,"text":512,"correct":32},"绘制电缆排列布置图",{"key":30,"text":514,"correct":22},"排列整齐",{"id":516,"libraryId":5,"type":15,"typeLabel":16,"stem":517,"options":518,"answer":24,"analysis":33},1262415,"电缆及其附件如不立即安装,应( )。",[519,521,523,525],{"key":20,"text":520,"correct":22},"松散堆放",{"key":24,"text":522,"correct":32},"集中分类存放",{"key":27,"text":524,"correct":22},"置于阳光下曝晒",{"key":30,"text":526,"correct":22},"每六个月检查一次",{"id":528,"libraryId":5,"type":15,"typeLabel":16,"stem":529,"options":530,"answer":27,"analysis":33},1262416,"母线水平安装可用( )。",[531,533,535,537],{"key":20,"text":532,"correct":22},"楼面支撑弹性支架",{"key":24,"text":534,"correct":22},"膨胀螺栓固定",{"key":27,"text":536,"correct":32},"托架或吊架",{"key":30,"text":538,"correct":22},"焊接固定",{"id":540,"libraryId":5,"type":15,"typeLabel":16,"stem":541,"options":542,"answer":27,"analysis":33},1262417,"金属桥架或线槽及其支架是以敷设电气线路为主的保护壳,和金属导管一样必须( )。",[543,545,547,549],{"key":20,"text":544,"correct":22},"用螺栓可靠连接",{"key":24,"text":546,"correct":22},"防腐蚀处理",{"key":27,"text":548,"correct":32},"接地可靠",{"key":30,"text":550,"correct":22},"确定走向",{"id":552,"libraryId":5,"type":15,"typeLabel":16,"stem":553,"options":554,"answer":20,"analysis":33},1262418,"绝缘导管的安装和弯曲,应在原材料规定的允许环境温度下进行,其温度不宜低于( )度。",[555,557,559,561],{"key":20,"text":556,"correct":32},"-15",{"key":24,"text":558,"correct":22},"-20",{"key":27,"text":560,"correct":22},"-10",{"key":30,"text":562,"correct":22},"-8",{"id":564,"libraryId":5,"type":15,"typeLabel":16,"stem":565,"options":566,"answer":20,"analysis":33},1262419,"钢管外壁刷漆要求与敷设方式和钢管种类有关,以下说法错误的是( )。",[567,569,571,573],{"key":20,"text":568,"correct":32},"埋人混凝土内的钢管需要刷防腐漆",{"key":24,"text":570,"correct":22},"埋人道渣垫层和土层内的钢管应刷两道沥青",{"key":27,"text":572,"correct":22},"埋人砖墙内的钢管应刷红丹漆等防腐",{"key":30,"text":574,"correct":22},"钢管明敷时,应刷一道防腐漆,一道面漆",[576,579,582,585,588,591],{"id":15,"name":577,"category":7,"favorite":578},"领导干部任职前廉政法规知识测试题",92,{"id":580,"name":581,"category":7,"favorite":15},595,"建筑结构与设备",{"id":583,"name":584,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":586,"name":587,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":589,"name":590,"category":7,"favorite":8},534,"BIM工程师",{"id":592,"name":590,"category":7,"favorite":8},535]