[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1254517":3},{"question":4,"library":20},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":17,"analysis":19},1254517,838,3,"判断题","对安装于主干管上的阀门，应抽查10％且不少于一个逐个作强度和严密性试验。",[11,15],{"key":12,"text":13,"correct":14},"A","正确",false,{"key":16,"text":17,"correct":18},"B","错误",true,"阀门安装前，应作强度和严密性试验。试验应在每批（同牌号、同型号、同规格）数量中抽查10%，且不少于一个。对于安装在主干管上起切断作用的闭路阀门，应逐个作强度和严密性试验。由施工方去做这个工作。",{"id":6,"name":21,"category":22,"favorite":23},"(设备安装施工)专业管理实务 岗位知识","建筑工程",0]