[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1254114":3},{"question":4,"library":29},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":27,"analysis":28},1254114,838,2,"多选题","ZC-8接地电阻测量仪使用的注意事项有（ ）。",[11,15,18,21,24],{"key":12,"text":13,"correct":14},"A","接地极、电位探测针、电流探测针三者成一直线，电位探测针居中，三者等距，均为20m",true,{"key":16,"text":17,"correct":14},"B","接地极、电位探测针、电流探测针各自引出相同截面的绝缘电线接至仪表上，要一一对应不可错接",{"key":19,"text":20,"correct":14},"C","ZC-8仪表应放置于水平位置，检查调零",{"key":22,"text":23,"correct":14},"D","先将倍率标度置于最大倍数，慢转摇把，使零指示器位于中间位置，加快转动速度至120γ\u002Fmin",{"key":25,"text":26,"correct":14},"E","测量标度盘的读数乘以倍率标度即得所测接地装置的接地电阻值","ABCDE","ZC-8接地电阻测量仪的使用的注意事项有：A.接地极、电位探测针、电流探测针三者成一直线，电位探测针居中，三者等距，均为20m。B.接地极、电位探测针、电流探测针各自引出相同截面的绝缘电线接至仪表上，要一一对应不可错节。C.ZC-8仪表应放置于水平位置，检查调零。D.先将倍率标度置于最大倍数，慢转摇把，使零指示器位于中间位置，加快转动速度至120γ\u002Fmin。E.如测量度盘读数小于1，应调整倍率标度于较小倍数，再调整测量标度盘，多次调整后，指针完全平衡在中心线上。F.测量标度盘的读数乘以倍率标度即得所测接地装置的接地电阻值。",{"id":6,"name":30,"category":31,"favorite":32},"(设备安装施工)专业管理实务 岗位知识","建筑工程",0]