[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-837-7":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":609},{"id":5,"name":6,"category":7,"favorite":8},837,"(设备安装施工)基础知识","建筑工程",0,7,50,1298,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,213,225,237,249,261,273,285,297,307,319,331,343,355,367,379,391,403,415,425,437,449,461,473,485,497,509,521,533,542,554,566,574,586,597],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},1252419,1,"单选题","圆形风管所注标高应表示（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","管中心标高",true,{"key":24,"text":25,"correct":26},"B","管底标高",false,{"key":28,"text":29,"correct":26},"C","管顶标高",{"key":31,"text":32,"correct":26},"D","相对标高","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},1252420,"适用于室内用水量均匀而室外供水系统压力不足，需要局部增压的给水系统。",[38,40,42,44],{"key":20,"text":39,"correct":26},"直接供水形式",{"key":24,"text":41,"correct":26},"附水箱供水形式",{"key":28,"text":43,"correct":22},"水泵给水形式",{"key":31,"text":45,"correct":26},"水池、水泵和水箱联合给水形式",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},1252421,"灯具安装时其质量大于（ ），必须固定在螺栓或预埋吊钩上。",[50,52,54,56],{"key":20,"text":51,"correct":26},"2kg",{"key":24,"text":53,"correct":22},"3kg",{"key":28,"text":55,"correct":26},"4kg",{"key":31,"text":57,"correct":26},"4.5kg",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":31,"analysis":33},1252422,"以下电缆敷设程序不正确的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":26},"先敷设集中排列的电缆，后敷设分散排列的电缆",{"key":24,"text":65,"correct":26},"先敷设长电缆，后敷设短电缆",{"key":28,"text":67,"correct":26},"并列敷设的电缆先内后外",{"key":31,"text":69,"correct":22},"上下敷设的电缆先上后下",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":28,"analysis":33},1252423,"金属桥架或线槽及其支架是以敷设电气线路为主的保护壳，和金属导管一样必须（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":26},"用螺栓可靠连接",{"key":24,"text":77,"correct":26},"防腐蚀处理",{"key":28,"text":79,"correct":22},"接地可靠",{"key":31,"text":81,"correct":26},"确定走向",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},1252424,"常用的电线型号中“BVP”表示（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":26},"铜芯聚氯乙烯绝缘电线",{"key":24,"text":89,"correct":22},"铜芯聚氯乙烯绝缘屏蔽电线",{"key":28,"text":91,"correct":26},"铜芯聚氯乙烯绝缘软线",{"key":31,"text":93,"correct":26},"铜芯橡皮绝缘电线",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":31,"analysis":33},1252425,"VRV系统是以下哪个系统的简称。",[98,100,102,104],{"key":20,"text":99,"correct":26},"集中式单风管空调系统",{"key":24,"text":101,"correct":26},"集中式双风管空调系统",{"key":28,"text":103,"correct":26},"风机盘管式空调系统",{"key":31,"text":105,"correct":22},"可变冷媒流量空调系统",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":20,"analysis":33},1252426,"检查电动机绕组和控制线路的绝缘电阻应不低于（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"0.5MΩ",{"key":24,"text":113,"correct":26},"0.7MΩ",{"key":28,"text":115,"correct":26},"0.9MΩ",{"key":31,"text":117,"correct":26},"1.0MΩ",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":31,"analysis":33},1252427,"嵌入式配电箱全部电器安装完毕后，用（ ）兆欧表对线路进行绝缘检测。",[122,124,126,128],{"key":20,"text":123,"correct":26},"220伏",{"key":24,"text":125,"correct":26},"300伏",{"key":28,"text":127,"correct":26},"450伏",{"key":31,"text":129,"correct":22},"500伏",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":31,"analysis":33},1252428,"室内灯具的安装方式主要有（ ）。",[134,136,138,140],{"key":20,"text":135,"correct":26},"吸顶式嵌入式挂式悬吊式",{"key":24,"text":137,"correct":26},"落地式吸顶式吸壁式悬吊式",{"key":28,"text":139,"correct":26},"吸顶式嵌入式挂式落地式",{"key":31,"text":141,"correct":22},"吸顶式嵌入式吸壁式悬吊式",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":24,"analysis":33},1252429,"生活给水系统在交付使用前必须进行消毒，以含20~30mg\u002FL游离氯的清洁水浸泡管道系统（ ）。",[146,148,150,152],{"key":20,"text":147,"correct":26},"12h",{"key":24,"text":149,"correct":22},"24h",{"key":28,"text":151,"correct":26},"36h",{"key":31,"text":153,"correct":26},"48h",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":20,"analysis":33},1252430,"聚乙烯（P E）管适用温度范围为（ ），具有良好的耐磨性、低温抗冲击性和耐化学腐蚀性。",[158,160,162,164],{"key":20,"text":159,"correct":22},"-60℃~+60℃",{"key":24,"text":161,"correct":26},"-80℃~+80℃",{"key":28,"text":163,"correct":26},"-40℃~+80℃",{"key":31,"text":165,"correct":26},"-40℃~+70℃",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":28,"analysis":33},1252431,"现浇钢筋混凝土楼梯根据（ ）不同分为板式楼梯和梁式楼梯。",[170,172,174,176],{"key":20,"text":171,"correct":26},"楼梯段的位置",{"key":24,"text":173,"correct":26},"楼梯使用性质",{"key":28,"text":175,"correct":22},"楼梯段结构形式",{"key":31,"text":177,"correct":26},"楼梯平面形式",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":24,"analysis":33},1252432,"下列导管分类中属于以导管通用程度分类的是（ ）。",[182,184,186,188],{"key":20,"text":183,"correct":26},"刚性导管",{"key":24,"text":185,"correct":22},"专用导管",{"key":28,"text":187,"correct":26},"柔性导管",{"key":31,"text":189,"correct":26},"可挠性导管",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":24,"analysis":33},1252433,"照明线路的绝缘摇测，摇动速度应保持在（ ）r\u002Fmin左右，读书应采用1min后的读数为宜。",[194,196,198,200],{"key":20,"text":195,"correct":26},"60",{"key":24,"text":197,"correct":22},"120",{"key":28,"text":199,"correct":26},"150",{"key":31,"text":201,"correct":26},"240",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":31,"analysis":33},1252434,"净化空调系统风管的法兰铆钉间距要求小于100mm，空气洁净等级为1、5的风管法兰铆钉间距要求小于（ ）mm。",[206,208,210,211],{"key":20,"text":207,"correct":26},"50",{"key":24,"text":209,"correct":26},"55",{"key":28,"text":195,"correct":26},{"key":31,"text":212,"correct":22},"65",{"id":214,"libraryId":5,"type":15,"typeLabel":16,"stem":215,"options":216,"answer":31,"analysis":33},1252435,"制冷剂阀门安装前应进行严密性试验，严密性试验压力为阀门公称压力的1.1倍，持续时间（ ）不漏为合格。",[217,219,221,223],{"key":20,"text":218,"correct":26},"15s",{"key":24,"text":220,"correct":26},"20s",{"key":28,"text":222,"correct":26},"25s",{"key":31,"text":224,"correct":22},"30s",{"id":226,"libraryId":5,"type":15,"typeLabel":16,"stem":227,"options":228,"answer":20,"analysis":33},1252436,"线路敷设方式文字符号中“PL”表示（ ）。",[229,231,233,235],{"key":20,"text":230,"correct":22},"塑料线卡",{"key":24,"text":232,"correct":26},"塑料管",{"key":28,"text":234,"correct":26},"塑料线槽",{"key":31,"text":236,"correct":26},"电线管",{"id":238,"libraryId":5,"type":15,"typeLabel":16,"stem":239,"options":240,"answer":20,"analysis":33},1252437,"给水排水平面图中管线或设备用（ ）。",[241,243,245,247],{"key":20,"text":242,"correct":22},"粗线",{"key":24,"text":244,"correct":26},"中粗线",{"key":28,"text":246,"correct":26},"中线",{"key":31,"text":248,"correct":26},"细线",{"id":250,"libraryId":5,"type":15,"typeLabel":16,"stem":251,"options":252,"answer":24,"analysis":33},1252438,"铸铁给水管下管时应根据管径大小、管道长度和重量、管材和接口强度、沟槽和现场情况而定，当管径小，重量轻时，一般采用（ ）。",[253,255,257,259],{"key":20,"text":254,"correct":26},"机械下管",{"key":24,"text":256,"correct":22},"人工下管",{"key":28,"text":258,"correct":26},"机械下管与人工下管共同使用",{"key":31,"text":260,"correct":26},"铺设管道基础垫层",{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":20,"analysis":33},1252439,"在同一建筑物内同类配电箱的高度应保持一致，允许偏差为（ ）。",[265,267,269,271],{"key":20,"text":266,"correct":22},"10mm",{"key":24,"text":268,"correct":26},"15mm",{"key":28,"text":270,"correct":26},"20mm",{"key":31,"text":272,"correct":26},"25mm",{"id":274,"libraryId":5,"type":15,"typeLabel":16,"stem":275,"options":276,"answer":28,"analysis":33},1252440,"如果电动机出厂日期超过了制造厂保证期限，或经检查后有可疑时应进行（ ）。",[277,279,281,283],{"key":20,"text":278,"correct":26},"拆开接线盒",{"key":24,"text":280,"correct":26},"检验绝缘电阻值",{"key":28,"text":282,"correct":22},"抽芯检查",{"key":31,"text":284,"correct":26},"外观检查",{"id":286,"libraryId":5,"type":15,"typeLabel":16,"stem":287,"options":288,"answer":24,"analysis":33},1252441,"柔性导管的长度在动力工程中不大于0.8m，在照明工程中不大于（ ）。",[289,291,293,295],{"key":20,"text":290,"correct":26},"0.8",{"key":24,"text":292,"correct":22},"1.2",{"key":28,"text":294,"correct":26},"1.5",{"key":31,"text":296,"correct":26},"1.8",{"id":298,"libraryId":5,"type":15,"typeLabel":16,"stem":299,"options":300,"answer":28,"analysis":33},1252442,"电线穿墙时应装过墙管保护，过墙管两端伸出墙面不小于（ ）。",[301,303,305,306],{"key":20,"text":302,"correct":26},"5mm",{"key":24,"text":304,"correct":26},"8mm",{"key":28,"text":266,"correct":22},{"key":31,"text":268,"correct":26},{"id":308,"libraryId":5,"type":15,"typeLabel":16,"stem":309,"options":310,"answer":20,"analysis":33},1252443,"风管系统按压力划分为三个类别，系统工作压力为500Pa的送风系统属（ ）。",[311,313,315,317],{"key":20,"text":312,"correct":22},"低压系统",{"key":24,"text":314,"correct":26},"中压系统",{"key":28,"text":316,"correct":26},"高压系统",{"key":31,"text":318,"correct":26},"超高压系统",{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":24,"analysis":33},1252444,"压力表应安装在便于观察的部位，当安装部位较高时，表盘可（ ）。",[323,325,327,329],{"key":20,"text":324,"correct":26},"稍向上倾斜",{"key":24,"text":326,"correct":22},"稍向下倾斜",{"key":28,"text":328,"correct":26},"稍向左倾斜",{"key":31,"text":330,"correct":26},"稍向右倾斜",{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":31,"analysis":33},1252445,"照明灯具使用的导线其电压等级不应低于交流（ ），其最小线芯截面应符合规定，接线端子光洁、无锈蚀等现象。",[335,337,339,341],{"key":20,"text":336,"correct":26},"220V",{"key":24,"text":338,"correct":26},"300V",{"key":28,"text":340,"correct":26},"400V",{"key":31,"text":342,"correct":22},"500V",{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":31,"analysis":33},1252446,"以下关于温度传感器的安装错误的是（ ）。",[347,349,351,353],{"key":20,"text":348,"correct":26},"风管型温度传感器的安装应在风管保温层完成之后进行",{"key":24,"text":350,"correct":26},"风管型温度传感器应安装在风管直管段的下游",{"key":28,"text":352,"correct":26},"水管型温度传感器的安装开孔与焊接工作，必须在管道的压力试验、清洗、防腐和保温前进行",{"key":31,"text":354,"correct":22},"水管型温度传感器的感温段小于管道直径的1\u002F2时，可安装在管道的顶部。",{"id":356,"libraryId":5,"type":15,"typeLabel":16,"stem":357,"options":358,"answer":24,"analysis":33},1252447,"管道与设备的连接应在设备安装完毕后进行，与风管、制冷机组的连接须（ ）。",[359,361,363,365],{"key":20,"text":360,"correct":26},"采取刚性连接",{"key":24,"text":362,"correct":22},"采取柔性连接",{"key":28,"text":364,"correct":26},"强行对口连接",{"key":31,"text":366,"correct":26},"置于套管内连接",{"id":368,"libraryId":5,"type":15,"typeLabel":16,"stem":369,"options":370,"answer":28,"analysis":33},1252448,"无缝钢管按制造方法分为热轧管和冷拔（轧）管。热轧管的最大公称直径为（ ）。",[371,373,375,377],{"key":20,"text":372,"correct":26},"200mm",{"key":24,"text":374,"correct":26},"400mm",{"key":28,"text":376,"correct":22},"600mm",{"key":31,"text":378,"correct":26},"800mm",{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":381,"options":382,"answer":24,"analysis":33},1252449,"对阀门强度试验时，试验压力为公称压力的1.5倍，持续时间不少于（ ），阀门的壳体、填料应无渗漏。",[383,385,387,389],{"key":20,"text":384,"correct":26},"3min",{"key":24,"text":386,"correct":22},"5min",{"key":28,"text":388,"correct":26},"8min",{"key":31,"text":390,"correct":26},"10min",{"id":392,"libraryId":5,"type":15,"typeLabel":16,"stem":393,"options":394,"answer":24,"analysis":33},1252450,"金属电缆桥架及其支架全长应不少于（ ）处与接地或接零干线相连接。",[395,397,399,401],{"key":20,"text":396,"correct":26},"1",{"key":24,"text":398,"correct":22},"2",{"key":28,"text":400,"correct":26},"3",{"key":31,"text":402,"correct":26},"4",{"id":404,"libraryId":5,"type":15,"typeLabel":16,"stem":405,"options":406,"answer":28,"analysis":33},1252451,"成品敞口水箱安装前应做（ ）",[407,409,411,413],{"key":20,"text":408,"correct":26},"盛水试验",{"key":24,"text":410,"correct":26},"煤油渗透试验",{"key":28,"text":412,"correct":22},"满水试验",{"key":31,"text":414,"correct":26},"水压试验",{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":417,"options":418,"answer":28,"analysis":33},1252452,"风管水平安装，直径或长边≤400mm时，支、吊架间距不大于（ ）。",[419,420,422,423],{"key":20,"text":372,"correct":26},{"key":24,"text":421,"correct":26},"300mm",{"key":28,"text":374,"correct":22},{"key":31,"text":424,"correct":26},"500mm",{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":31,"analysis":33},1252453,"塑料电线管（PVC电线管）根据目前国家建筑市场中的型号可分为轻型、中型、重型三种，在建筑施工中宜采用（ ）。",[429,431,433,435],{"key":20,"text":430,"correct":26},"轻型",{"key":24,"text":432,"correct":26},"中型",{"key":28,"text":434,"correct":26},"重型",{"key":31,"text":436,"correct":22},"中型、重型",{"id":438,"libraryId":5,"type":15,"typeLabel":16,"stem":439,"options":440,"answer":28,"analysis":33},1252454,"对安装在顶棚装饰材料上的灯具，若灯泡距顶棚或木台太近，且顶棚为易燃材料时，应在灯具底座与顶棚间或灯泡与木台间放置（ ）。",[441,443,445,447],{"key":20,"text":442,"correct":26},"绝缘子",{"key":24,"text":444,"correct":26},"熔断器",{"key":28,"text":446,"correct":22},"隔热垫",{"key":31,"text":448,"correct":26},"防水垫",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":28,"analysis":33},1252455,"下列关于结构整体简化正确的是（ ）。",[453,455,457,459],{"key":20,"text":454,"correct":26},"把空间结构都要分解为平面结构",{"key":24,"text":456,"correct":26},"若空间结构可以由几种不同类型平面结构组成，则要单独分解",{"key":28,"text":458,"correct":22},"对于多跨多层的空间刚架，可以截取纵向或横向平面刚架来分析",{"key":31,"text":460,"correct":26},"对延长方向结构的横截面保持不变的结构，可沿纵轴截取平面结构",{"id":462,"libraryId":5,"type":15,"typeLabel":16,"stem":463,"options":464,"answer":31,"analysis":33},1252456,"塑料排水管道的安装时，粘结前应对承插口先插入试验，不得全部插入，一般为承口的（ ）深度。",[465,467,469,471],{"key":20,"text":466,"correct":26},"1\u002F3",{"key":24,"text":468,"correct":26},"2\u002F3",{"key":28,"text":470,"correct":26},"1\u002F2",{"key":31,"text":472,"correct":22},"3\u002F4",{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":28,"analysis":33},1252457,"室外埋地排水管道一般沿道路平行于建筑物铺设，与建筑物的距离不小于（ ）。",[477,479,481,483],{"key":20,"text":478,"correct":26},"2~4m",{"key":24,"text":480,"correct":26},"2~5m",{"key":28,"text":482,"correct":22},"3~5m",{"key":31,"text":484,"correct":26},"3~6m",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":24,"analysis":33},1252458,"在风管穿过需要封闭的防火、防爆的墙体或楼板时，应（ ）。",[489,491,493,495],{"key":20,"text":490,"correct":26},"增加管壁厚度不应小于1.2mm",{"key":24,"text":492,"correct":22},"设预埋管或防护套管",{"key":28,"text":494,"correct":26},"采用耐热不燃的材料替换",{"key":31,"text":496,"correct":26},"控制离地高度",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":24,"analysis":33},1252459,"电缆及其附件如不立即安装，应（ ）。",[501,503,505,507],{"key":20,"text":502,"correct":26},"松散堆放",{"key":24,"text":504,"correct":22},"集中分类存放",{"key":28,"text":506,"correct":26},"至于阳关下曝晒",{"key":31,"text":508,"correct":26},"每六个月检查一次",{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":20,"analysis":33},1252460,"室外给水钢管安装时，管道接口法兰应安装在检查井内，不得埋在土里，如必须埋在土里，法兰应采取（ ）。",[513,515,517,519],{"key":20,"text":514,"correct":22},"防腐蚀措施",{"key":24,"text":516,"correct":26},"保温措施",{"key":28,"text":518,"correct":26},"防漏措施",{"key":31,"text":520,"correct":26},"防塌方措施",{"id":522,"libraryId":5,"type":15,"typeLabel":16,"stem":523,"options":524,"answer":31,"analysis":33},1252461,"标高所标注位置通常是管子的（ ）。",[525,527,529,531],{"key":20,"text":526,"correct":26},"管顶",{"key":24,"text":528,"correct":26},"管底",{"key":28,"text":530,"correct":26},"边缘",{"key":31,"text":532,"correct":22},"中心位置",{"id":534,"libraryId":5,"type":15,"typeLabel":16,"stem":535,"options":536,"answer":24,"analysis":33},1252462,"明配的导管固定点间距均匀，安装牢固，DN20壁厚≤2mm刚性钢导管沿墙明敷中间直线段管卡间的最大距离（ ）m。",[537,539,540,541],{"key":20,"text":538,"correct":26},"0.5",{"key":24,"text":396,"correct":22},{"key":28,"text":294,"correct":26},{"key":31,"text":398,"correct":26},{"id":543,"libraryId":5,"type":15,"typeLabel":16,"stem":544,"options":545,"answer":20,"analysis":33},1252463,"建筑电气工程是为建筑物建造的电气设施，这种设备要确保在使用中对建筑物和使用建筑物的人都有可靠的（ ）。",[546,548,550,552],{"key":20,"text":547,"correct":22},"安全保障",{"key":24,"text":549,"correct":26},"功能保障",{"key":28,"text":551,"correct":26},"使用保障",{"key":31,"text":553,"correct":26},"节能保障",{"id":555,"libraryId":5,"type":15,"typeLabel":16,"stem":556,"options":557,"answer":20,"analysis":33},1252464,"绝缘导管的安装和弯曲，应在原材料规定的允许环境温度下进行，其温度不宜低于（ ）。",[558,560,562,564],{"key":20,"text":559,"correct":22},"A.&ndash;15℃",{"key":24,"text":561,"correct":26},"&ndash;20℃",{"key":28,"text":563,"correct":26},"&ndash;10℃",{"key":31,"text":565,"correct":26},"&ndash;8℃",{"id":567,"libraryId":5,"type":15,"typeLabel":16,"stem":568,"options":569,"answer":24,"analysis":33},1252465,"金属电缆桥架及其支架全长应不少于（ ）处与接地（P E）或接零（PEN）干线相连接。",[570,571,572,573],{"key":20,"text":396,"correct":26},{"key":24,"text":398,"correct":22},{"key":28,"text":400,"correct":26},{"key":31,"text":402,"correct":26},{"id":575,"libraryId":5,"type":15,"typeLabel":16,"stem":576,"options":577,"answer":24,"analysis":33},1252466,"埋地管道防腐加强级防腐结构是（ ）。",[578,580,582,584],{"key":20,"text":579,"correct":26},"底漆一面漆一面漆一面漆",{"key":24,"text":581,"correct":22},"底漆一面漆一面漆、玻璃布、面漆一面漆",{"key":28,"text":583,"correct":26},"底漆一面漆一面漆、玻璃布、面漆一面漆、玻璃布",{"key":31,"text":585,"correct":26},"底漆一面漆一面漆、玻璃布、面漆一面漆、玻璃布、面漆一面漆",{"id":587,"libraryId":5,"type":15,"typeLabel":16,"stem":588,"options":589,"answer":24,"analysis":33},1252467,"卫生器具交付前应作（ ）。",[590,592,593,595],{"key":20,"text":591,"correct":26},"试压",{"key":24,"text":412,"correct":22},{"key":28,"text":594,"correct":26},"通球试验",{"key":31,"text":596,"correct":26},"灌水试验",{"id":598,"libraryId":5,"type":15,"typeLabel":16,"stem":599,"options":600,"answer":24,"analysis":33},1252468,"金属导管（ ）对口熔焊连接；镀锌和壁厚小于等于2mm的钢导管不得套管熔焊连接。",[601,603,605,607],{"key":20,"text":602,"correct":26},"可以",{"key":24,"text":604,"correct":22},"严禁",{"key":28,"text":606,"correct":26},"宜",{"key":31,"text":608,"correct":26},"应",[610,613,616,619,622,625],{"id":15,"name":611,"category":7,"favorite":612},"领导干部任职前廉政法规知识测试题",92,{"id":614,"name":615,"category":7,"favorite":15},595,"建筑结构与设备",{"id":617,"name":618,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":620,"name":621,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":623,"name":624,"category":7,"favorite":8},534,"BIM工程师",{"id":626,"name":624,"category":7,"favorite":8},535]