[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-837-6":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":606},{"id":5,"name":6,"category":7,"favorite":8},837,"(设备安装施工)基础知识","建筑工程",0,6,50,1298,[13,34,46,58,70,82,94,106,118,130,142,152,164,176,188,200,212,224,236,245,257,269,281,293,305,315,327,337,349,361,373,385,397,409,421,432,444,456,466,478,490,502,514,524,536,548,560,570,582,594],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},1252369,1,"单选题","每个报警阀组控制的最不利点喷头处，应设（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","末端试水装置",true,{"key":24,"text":25,"correct":26},"B","自动排气装置",false,{"key":28,"text":29,"correct":26},"C","安全阀",{"key":31,"text":32,"correct":26},"D","疏水阀","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},1252370,"管道系统的冲洗应在管道试压合格（ ），调试、运行（ ）进行。",[38,40,42,44],{"key":20,"text":39,"correct":26},"前后",{"key":24,"text":41,"correct":26},"前前",{"key":28,"text":43,"correct":26},"后后",{"key":31,"text":45,"correct":22},"后前",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},1252371,"隐蔽或埋地的排水管道在隐蔽前必须做灌水试验，其灌水高度应不低于底层卫生器具的上边缘或底层地面高度。检验方法：满水（ ）水面下降后，再灌满观察（ ），液面不降，管道及接口无渗漏为合格。",[50,52,54,56],{"key":20,"text":51,"correct":26},"15min15min",{"key":24,"text":53,"correct":26},"5min5min",{"key":28,"text":55,"correct":26},"5min15min",{"key":31,"text":57,"correct":22},"15min5min",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},1252372,"钢管外壁刷漆要求与敷设方式和钢管种类有关，以下说法错误的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"埋入混凝土内的钢管需要刷防腐漆",{"key":24,"text":65,"correct":26},"埋入道渣垫层和土层内的钢管应刷两道沥青",{"key":28,"text":67,"correct":26},"埋入砖墙内的钢管应刷红丹漆等防腐",{"key":31,"text":69,"correct":26},"钢管明敷时，应刷一道防腐漆，一道面漆",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":31,"analysis":33},1252373,"市政给水管网、污水排放管网均属于市政设施，其建造属（ ）范畴。",[74,76,78,80],{"key":20,"text":75,"correct":26},"给水工程",{"key":24,"text":77,"correct":26},"排水工程",{"key":28,"text":79,"correct":26},"安装工程",{"key":31,"text":81,"correct":22},"市政工程",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":31,"analysis":33},1252374,"不锈钢管的连接方式多样，下面哪种不是不锈钢管常见的管件类型（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":26},"活套式法兰连接",{"key":24,"text":89,"correct":26},"压紧式",{"key":28,"text":91,"correct":26},"承插焊接式",{"key":31,"text":93,"correct":22},"柔性平口连接",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":20,"analysis":33},1252375,"（ ）以其制作省工及适于在安装加工现场集中预制，因而采用十分广泛，并已成为设备安装所有管件中主要采取的类型。",[98,100,102,104],{"key":20,"text":99,"correct":22},"无缝钢管管件",{"key":24,"text":101,"correct":26},"可锻铸铁钢管",{"key":28,"text":103,"correct":26},"球墨铸铁管件",{"key":31,"text":105,"correct":26},"硬聚氯乙烯管件",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},1252376,"对阀门强度试验时，试验压力为公称压力的（ ）倍。",[110,112,114,116],{"key":20,"text":111,"correct":26},"1.0",{"key":24,"text":113,"correct":22},"1.5",{"key":28,"text":115,"correct":26},"2.0",{"key":31,"text":117,"correct":26},"2.5",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":28,"analysis":33},1252377,"下列楼梯中属于按楼梯平面形式分类的为（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":26},"辅助楼梯",{"key":24,"text":125,"correct":26},"封闭楼梯间",{"key":28,"text":127,"correct":22},"双跑平行楼梯",{"key":31,"text":129,"correct":26},"主要楼梯",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":31,"analysis":33},1252378,"电力线缆的作用是（ ）。",[134,136,138,140],{"key":20,"text":135,"correct":26},"为信号提供通路",{"key":24,"text":137,"correct":26},"为指令提供通路",{"key":28,"text":139,"correct":26},"为测量数据提供通路",{"key":31,"text":141,"correct":22},"供应电力",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":24,"analysis":33},1252379,"安全出口标志灯距地高度不低于（ ）m，且安装在疏散出口和楼梯口里侧的上方。",[146,147,149,150],{"key":20,"text":113,"correct":26},{"key":24,"text":148,"correct":22},"2",{"key":28,"text":117,"correct":26},{"key":31,"text":151,"correct":26},"3",{"id":153,"libraryId":5,"type":15,"typeLabel":16,"stem":154,"options":155,"answer":20,"analysis":33},1252380,"“倒铺法”保温的构造层次依次是（ ）",[156,158,160,162],{"key":20,"text":157,"correct":22},"保温层防水层结构层",{"key":24,"text":159,"correct":26},"防水层结构层保温层",{"key":28,"text":161,"correct":26},"防水层保温层结构层",{"key":31,"text":163,"correct":26},"保温层结构层防水层",{"id":165,"libraryId":5,"type":15,"typeLabel":16,"stem":166,"options":167,"answer":31,"analysis":33},1252381,"不需要考虑可拆卸形式的保冷结构的部位是（ ）。",[168,170,172,174],{"key":20,"text":169,"correct":26},"人孔",{"key":24,"text":171,"correct":26},"阀门",{"key":28,"text":173,"correct":26},"法兰",{"key":31,"text":175,"correct":22},"吊架",{"id":177,"libraryId":5,"type":15,"typeLabel":16,"stem":178,"options":179,"answer":20,"analysis":33},1252382,"复合材料风管的覆面材料必须为（ ）。",[180,182,184,186],{"key":20,"text":181,"correct":22},"不燃材料",{"key":24,"text":183,"correct":26},"难燃材料",{"key":28,"text":185,"correct":26},"绝缘材料",{"key":31,"text":187,"correct":26},"塑性材料",{"id":189,"libraryId":5,"type":15,"typeLabel":16,"stem":190,"options":191,"answer":28,"analysis":33},1252383,"泛水通常先用水泥砂浆在垂直面与屋面交界处做成半径大于（ ）mm的圆弧。",[192,194,196,198],{"key":20,"text":193,"correct":26},"10",{"key":24,"text":195,"correct":26},"20",{"key":28,"text":197,"correct":22},"50",{"key":31,"text":199,"correct":26},"80",{"id":201,"libraryId":5,"type":15,"typeLabel":16,"stem":202,"options":203,"answer":24,"analysis":33},1252384,"通球试验的通球球径不小于排水管径的（ ）。",[204,206,208,210],{"key":20,"text":205,"correct":26},"3\u002F4",{"key":24,"text":207,"correct":22},"2\u002F3",{"key":28,"text":209,"correct":26},"1\u002F2",{"key":31,"text":211,"correct":26},"1\u002F3",{"id":213,"libraryId":5,"type":15,"typeLabel":16,"stem":214,"options":215,"answer":24,"analysis":33},1252385,"电力电缆在桥架内横断面的填充率不应大于（ ）。",[216,218,220,222],{"key":20,"text":217,"correct":26},"0.3",{"key":24,"text":219,"correct":22},"40％",{"key":28,"text":221,"correct":26},"50％",{"key":31,"text":223,"correct":26},"60%",{"id":225,"libraryId":5,"type":15,"typeLabel":16,"stem":226,"options":227,"answer":31,"analysis":33},1252386,"浇筑混凝土管墩、管座时，应待混凝土的强度达到（ ）以上方可回土。",[228,230,232,234],{"key":20,"text":229,"correct":26},"2MPa",{"key":24,"text":231,"correct":26},"3MPa",{"key":28,"text":233,"correct":26},"4MPa",{"key":31,"text":235,"correct":22},"5MPa",{"id":237,"libraryId":5,"type":15,"typeLabel":16,"stem":238,"options":239,"answer":24,"analysis":33},1252387,"室内给水管道的水压试验，当设计未注明时，一般应为工作压力的（ ）。",[240,242,243,244],{"key":20,"text":241,"correct":26},"1",{"key":24,"text":113,"correct":22},{"key":28,"text":148,"correct":26},{"key":31,"text":117,"correct":26},{"id":246,"libraryId":5,"type":15,"typeLabel":16,"stem":247,"options":248,"answer":28,"analysis":33},1252388,"母线水平安装可用（ ）。",[249,251,253,255],{"key":20,"text":250,"correct":26},"楼面职称弹性支架",{"key":24,"text":252,"correct":26},"膨胀螺栓固定",{"key":28,"text":254,"correct":22},"托架或吊架",{"key":31,"text":256,"correct":26},"焊接固定",{"id":258,"libraryId":5,"type":15,"typeLabel":16,"stem":259,"options":260,"answer":24,"analysis":33},1252389,"开关安装位置应便于操作，开关边缘距门框边缘距离（ ）。",[261,263,265,267],{"key":20,"text":262,"correct":26},"0.10~0.15m",{"key":24,"text":264,"correct":22},"0.15~0.20m",{"key":28,"text":266,"correct":26},"0.20~0.25m",{"key":31,"text":268,"correct":26},"0.25~0.30m",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":24,"analysis":33},1252390,"安装在墙上的手动火灾报警按钮距地面高度为（ ）。",[273,275,277,279],{"key":20,"text":274,"correct":26},"1.2m",{"key":24,"text":276,"correct":22},"1.5m",{"key":28,"text":278,"correct":26},"1.6m",{"key":31,"text":280,"correct":26},"1.8m",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":20,"analysis":33},1252391,"防火分区隔墙两侧的防火阀距墙体表面不应大于（ ）。",[285,287,289,291],{"key":20,"text":286,"correct":22},"200mm",{"key":24,"text":288,"correct":26},"300mm",{"key":28,"text":290,"correct":26},"400mm",{"key":31,"text":292,"correct":26},"500mm",{"id":294,"libraryId":5,"type":15,"typeLabel":16,"stem":295,"options":296,"answer":28,"analysis":33},1252392,"金属排水管上的吊钩或卡箍应固定在（ ）上。",[297,299,301,303],{"key":20,"text":298,"correct":26},"围护结构",{"key":24,"text":300,"correct":26},"支撑结构",{"key":28,"text":302,"correct":22},"承重结构",{"key":31,"text":304,"correct":26},"随意固定",{"id":306,"libraryId":5,"type":15,"typeLabel":16,"stem":307,"options":308,"answer":24,"analysis":33},1252393,"建筑排水硬聚氯乙烯管立管的支承件间距，当立管外径为50mm时不大于（ ）。",[309,311,312,313],{"key":20,"text":310,"correct":26},"1.0m",{"key":24,"text":274,"correct":22},{"key":28,"text":276,"correct":26},{"key":31,"text":314,"correct":26},"2m",{"id":316,"libraryId":5,"type":15,"typeLabel":16,"stem":317,"options":318,"answer":28,"analysis":33},1252394,"系统平衡调整后，各空调机组的水流量应符合设计要求，允许偏差为（ ）",[319,321,323,325],{"key":20,"text":320,"correct":26},"10%",{"key":24,"text":322,"correct":26},"15%",{"key":28,"text":324,"correct":22},"20%",{"key":31,"text":326,"correct":26},"25%",{"id":328,"libraryId":5,"type":15,"typeLabel":16,"stem":329,"options":330,"answer":28,"analysis":33},1252395,"非镀锌电缆桥架间连接板的两端跨接铜芯接地线，接地线最小允许截面积不小于（ ）m㎡。",[331,332,333,335],{"key":20,"text":113,"correct":26},{"key":24,"text":117,"correct":26},{"key":28,"text":334,"correct":22},"4",{"key":31,"text":336,"correct":26},"6",{"id":338,"libraryId":5,"type":15,"typeLabel":16,"stem":339,"options":340,"answer":31,"analysis":33},1252396,"管道法兰连接一般用于消防、喷淋及空调水系统的（ ）的连接。",[341,343,345,347],{"key":20,"text":342,"correct":26},"焊接钢管",{"key":24,"text":344,"correct":26},"塑料管",{"key":28,"text":346,"correct":26},"铝塑复合管",{"key":31,"text":348,"correct":22},"无缝钢管、螺旋管",{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":24,"analysis":33},1252397,"建筑工程施工时，给水排水工程的管理和作业人员要进行积极的配合，为日后工程的实施创造良好的条件。配合的内容除少数的直埋支管外，大量的是（ ）。",[353,355,357,359],{"key":20,"text":354,"correct":26},"设污水、废水及雨水管道",{"key":24,"text":356,"correct":22},"预埋构件、预留孔洞",{"key":28,"text":358,"correct":26},"设置阀门等给水附件",{"key":31,"text":360,"correct":26},"做好管道防腐和保温工作",{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":28,"analysis":33},1252398,"下面对刚性防水屋面的特点描述错误的是（ ）。",[365,367,369,371],{"key":20,"text":366,"correct":26},"构造简单",{"key":24,"text":368,"correct":26},"造价低",{"key":28,"text":370,"correct":22},"不易开裂",{"key":31,"text":372,"correct":26},"施工方便",{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":24,"analysis":33},1252399,"配电箱的安装高度以设计为准，箱体安装应保持水平和垂直，安装的垂直度允许偏差为（ ）。",[377,379,381,383],{"key":20,"text":378,"correct":26},"1.0‰",{"key":24,"text":380,"correct":22},"1.5‰",{"key":28,"text":382,"correct":26},"2.0‰",{"key":31,"text":384,"correct":26},"2.5‰",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":31,"analysis":33},1252400,"支架的悬臂、吊架的横担采用（ ）制作。",[389,391,393,395],{"key":20,"text":390,"correct":26},"圆钢",{"key":24,"text":392,"correct":26},"圆钢和扁钢",{"key":28,"text":394,"correct":26},"扁钢",{"key":31,"text":396,"correct":22},"角钢或槽钢",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":24,"analysis":33},1252401,"以下不属于空调系统的构成的是（ ）。",[401,403,405,407],{"key":20,"text":402,"correct":26},"空气处理系统",{"key":24,"text":404,"correct":22},"送风排风系统",{"key":28,"text":406,"correct":26},"冷热源系统",{"key":31,"text":408,"correct":26},"能量输送分配系统",{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":411,"options":412,"answer":31,"analysis":33},1252402,"室内采暖施工图中室内供暖系统字母代号为（ ）。",[413,415,417,419],{"key":20,"text":414,"correct":26},"L",{"key":24,"text":416,"correct":26},"R",{"key":28,"text":418,"correct":26},"P",{"key":31,"text":420,"correct":22},"N",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":31,"analysis":33},1252403,"综合布线系统中的光纤应按（ ）测试。",[425,427,429,430],{"key":20,"text":426,"correct":26},"10％",{"key":24,"text":428,"correct":26},"30％",{"key":28,"text":221,"correct":26},{"key":31,"text":431,"correct":22},"全部",{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":434,"options":435,"answer":28,"analysis":33},1252404,"当系统洁净度的等级为6~9级时，风管的法兰铆钉孔的间距不应大于（ ）。",[436,438,440,442],{"key":20,"text":437,"correct":26},"65mm",{"key":24,"text":439,"correct":26},"85mm",{"key":28,"text":441,"correct":22},"100mm",{"key":31,"text":443,"correct":26},"115mm",{"id":445,"libraryId":5,"type":15,"typeLabel":16,"stem":446,"options":447,"answer":31,"analysis":33},1252405,"管径大于等于100mm的镀锌钢管应采用（ ）连接。",[448,450,452,454],{"key":20,"text":449,"correct":26},"焊接",{"key":24,"text":451,"correct":26},"承插",{"key":28,"text":453,"correct":26},"螺纹",{"key":31,"text":455,"correct":22},"卡箍",{"id":457,"libraryId":5,"type":15,"typeLabel":16,"stem":458,"options":459,"answer":24,"analysis":33},1252406,"点型感烟火灾探测器的安装间距，不应超过（ ）。",[460,461,463,464],{"key":20,"text":193,"correct":26},{"key":24,"text":462,"correct":22},"15",{"key":28,"text":195,"correct":26},{"key":31,"text":465,"correct":26},"25",{"id":467,"libraryId":5,"type":15,"typeLabel":16,"stem":468,"options":469,"answer":20,"analysis":33},1252407,"消防工程验收由（ ）单位组织。",[470,472,474,476],{"key":20,"text":471,"correct":22},"建设",{"key":24,"text":473,"correct":26},"施工",{"key":28,"text":475,"correct":26},"监理",{"key":31,"text":477,"correct":26},"设计",{"id":479,"libraryId":5,"type":15,"typeLabel":16,"stem":480,"options":481,"answer":24,"analysis":33},1252408,"在建筑工程施工时电气专业要积极、正确、及时与（ ）配合。",[482,484,486,488],{"key":20,"text":483,"correct":26},"给水排水工程施工",{"key":24,"text":485,"correct":22},"土建工程施工",{"key":28,"text":487,"correct":26},"通风与空调工程施工",{"key":31,"text":489,"correct":26},"消防工程",{"id":491,"libraryId":5,"type":15,"typeLabel":16,"stem":492,"options":493,"answer":28,"analysis":33},1252409,"防雷接地系统中的避雷针、网、带的连接一般采用搭接焊，其焊接长度满足要求的是（ ）",[494,496,498,500],{"key":20,"text":495,"correct":26},"圆钢与扁钢连接时，其长度为圆钢直径的5倍",{"key":24,"text":497,"correct":26},"扁钢为其宽度的3倍，两面施焊",{"key":28,"text":499,"correct":22},"扁钢为其宽度的2倍，三面施焊",{"key":31,"text":501,"correct":26},"圆钢为其长度的6倍，三面施焊",{"id":503,"libraryId":5,"type":15,"typeLabel":16,"stem":504,"options":505,"answer":28,"analysis":33},1252410,"空调冷热水系统安装完毕，外观检验合格后，进行压力试验。系统设计工作压力为1.6MPa，但设计未规定试验压力，则试验压力应为（ ）。",[506,508,510,512],{"key":20,"text":507,"correct":26},"1.6MPa",{"key":24,"text":509,"correct":26},"1.84MPa",{"key":28,"text":511,"correct":22},"2.1MPa",{"key":31,"text":513,"correct":26},"2.4MPa",{"id":515,"libraryId":5,"type":15,"typeLabel":16,"stem":516,"options":517,"answer":24,"analysis":33},1252411,"在上人屋面上，通气管应高出屋面（ ），并应根据防雷要求设置防雷装置。",[518,520,521,522],{"key":20,"text":519,"correct":26},"1m",{"key":24,"text":314,"correct":22},{"key":28,"text":276,"correct":26},{"key":31,"text":523,"correct":26},"0.8m",{"id":525,"libraryId":5,"type":15,"typeLabel":16,"stem":526,"options":527,"answer":20,"analysis":33},1252412,"布线系统中电线敷设的要求用类似数学公式的文字表达正确的是（ ）。",[528,530,532,534],{"key":20,"text":529,"correct":22},"a-d（e×f）g-h",{"key":24,"text":531,"correct":26},"a-e（d×f）h-g",{"key":28,"text":533,"correct":26},"e-d（a×f）g-h",{"key":31,"text":535,"correct":26},"d-a（g×f）e-h",{"id":537,"libraryId":5,"type":15,"typeLabel":16,"stem":538,"options":539,"answer":20,"analysis":33},1252413,"配电柜（盘）安装调整结束后，应用螺栓将柜体与（ ）进行紧固。",[540,542,544,546],{"key":20,"text":541,"correct":22},"基础型钢",{"key":24,"text":543,"correct":26},"不锈钢底座",{"key":28,"text":545,"correct":26},"水泥基础",{"key":31,"text":547,"correct":26},"室内地面",{"id":549,"libraryId":5,"type":15,"typeLabel":16,"stem":550,"options":551,"answer":24,"analysis":33},1252414,"建筑电气工程中，按供电对象的负荷分类不包括（ ）。",[552,554,556,558],{"key":20,"text":553,"correct":26},"照明负荷",{"key":24,"text":555,"correct":22},"短时工作制负荷",{"key":28,"text":557,"correct":26},"民用建筑负荷",{"key":31,"text":559,"correct":26},"通信及数据处理设备负荷",{"id":561,"libraryId":5,"type":15,"typeLabel":16,"stem":562,"options":563,"answer":24,"analysis":33},1252415,"矩形风管立面与吊杆的间距不宜大于（ ）。",[564,565,567,568],{"key":20,"text":441,"correct":26},{"key":24,"text":566,"correct":22},"150mm",{"key":28,"text":286,"correct":26},{"key":31,"text":569,"correct":26},"250mm",{"id":571,"libraryId":5,"type":15,"typeLabel":16,"stem":572,"options":573,"answer":31,"analysis":33},1252416,"属于卫生器具排水附件的是（ ）。",[574,576,578,580],{"key":20,"text":575,"correct":26},"冲洗阀",{"key":24,"text":577,"correct":26},"浮球阀",{"key":28,"text":579,"correct":26},"配水阀",{"key":31,"text":581,"correct":22},"存水弯",{"id":583,"libraryId":5,"type":15,"typeLabel":16,"stem":584,"options":585,"answer":28,"analysis":33},1252417,"镀锌钢管进盒、箱采用套丝，锁母连接，丝长以安装完后外露（ ）丝为宜。",[586,588,590,592],{"key":20,"text":587,"correct":26},"1~2",{"key":24,"text":589,"correct":26},"1~3",{"key":28,"text":591,"correct":22},"2~3",{"key":31,"text":593,"correct":26},"2~4",{"id":595,"libraryId":5,"type":15,"typeLabel":16,"stem":596,"options":597,"answer":20,"analysis":33},1252418,"当悬吊在楼板下面的污水横管上有（ ）个及以上大便器时，应在横管的起端设清扫口。",[598,600,602,604],{"key":20,"text":599,"correct":22},"二",{"key":24,"text":601,"correct":26},"三",{"key":28,"text":603,"correct":26},"四",{"key":31,"text":605,"correct":26},"五",[607,610,613,616,619,622],{"id":15,"name":608,"category":7,"favorite":609},"领导干部任职前廉政法规知识测试题",92,{"id":611,"name":612,"category":7,"favorite":15},595,"建筑结构与设备",{"id":614,"name":615,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":617,"name":618,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":620,"name":621,"category":7,"favorite":8},534,"BIM工程师",{"id":623,"name":621,"category":7,"favorite":8},535]