[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-837-15":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":619},{"id":5,"name":6,"category":7,"favorite":8},837,"(设备安装施工)基础知识","建筑工程",0,15,50,1298,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,226,238,250,262,274,286,298,310,322,334,344,356,368,380,392,404,416,428,440,452,464,476,488,500,512,524,536,548,560,572,583,595,607],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},1252819,1,"单选题","机械设备安装找标高过程中，标高调整的方法是（ ）",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","利用千斤顶顶升",false,{"key":24,"text":25,"correct":22},"B","调整调节螺钉",{"key":27,"text":28,"correct":29},"C","调整垫铁高度",true,{"key":31,"text":32,"correct":22},"D","楔入专用斜铁器","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},1252820,"以下关于施工项目经理部综合性的描述，错误的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"施工项目经理部是企业所属的经济组织，主要职责是管理施工项目的各种经济活动",{"key":24,"text":41,"correct":22},"施工项目经理部的管理职能是综合的，包括计划、组织、控制、协调、指挥等多方面",{"key":27,"text":43,"correct":22},"施工项目经理部的管理业务是综合的，从横向看包括人、财、物、生产和经营活动，从纵向看包括施工项目寿命周期的主要过程",{"key":31,"text":45,"correct":29},"施工项目经理部受企业多个职能部门的领导",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},1252821,"施工组织设计的关键是保证（ ）目标的实现。",[50,52,54,56],{"key":20,"text":51,"correct":22},"进度",{"key":24,"text":53,"correct":29},"质量",{"key":27,"text":55,"correct":22},"成本",{"key":31,"text":57,"correct":22},"安全",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":27,"analysis":33},1252822,"起重机吊装载荷是指（ ）",[62,64,66,68],{"key":20,"text":63,"correct":22},"吊物重量",{"key":24,"text":65,"correct":22},"吊物重量乘载荷系数",{"key":27,"text":67,"correct":29},"吊物重量加吊索及附件重量",{"key":31,"text":69,"correct":22},"吊物重量加吊索重量之和乘载荷系数",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":27,"analysis":33},1252823,"电缆接头的两侧绝缘垫间的耐压值，不得低于电缆保护层绝缘水平的",[74,76,78,80],{"key":20,"text":75,"correct":22},"1.2倍",{"key":24,"text":77,"correct":22},"1.5倍",{"key":27,"text":79,"correct":29},"2.0倍",{"key":31,"text":81,"correct":22},"2.5倍",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":20,"analysis":33},1252824,"危险等级分值在160-320是属于（ ）危险程度",[86,88,90,92],{"key":20,"text":87,"correct":29},"高度危险.不可能继续作业",{"key":24,"text":89,"correct":22},"一般危险.需要注意",{"key":27,"text":91,"correct":22},"极其危险.不可能继续作业",{"key":31,"text":93,"correct":22},"显著危险.需要整改",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":27,"analysis":33},1252825,"特种设备安全监督管理部门的职责是定期向社会公布特种设备的安全状况和（ ）",[98,100,102,104],{"key":20,"text":99,"correct":22},"优质产品推广目录",{"key":24,"text":101,"correct":22},"不合格产品品牌和型号",{"key":27,"text":103,"correct":29},"能效状况",{"key":31,"text":105,"correct":22},"重大责任事故及处理通报",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":27,"analysis":33},1252826,"锅炉安装单位必须经单位所在地的（ ）批准，取得相应级别锅炉的安装资格。",[110,112,114,116],{"key":20,"text":111,"correct":22},"市级建设行政主管部门",{"key":24,"text":113,"correct":22},"市级质量检验检测机构",{"key":27,"text":115,"correct":29},"省级特种设备安全监督管理部门",{"key":31,"text":117,"correct":22},"国务院特种设备安全监督管理部门",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":31,"analysis":33},1252827,"《钢结构工程施工质量验收规范》规定，低合金结构钢在环境温度低于（ ）时，不应进行冷矫正和冷弯曲",[122,124,126,128],{"key":20,"text":123,"correct":22},"-18℃",{"key":24,"text":125,"correct":22},"-16℃",{"key":27,"text":127,"correct":22},"-14℃",{"key":31,"text":129,"correct":29},"-12℃",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":31,"analysis":33},1252828,"常用于工作压力不超过1.3MPa，介质温度不超过200℃的直径较大的管道，一般选用（ ）",[134,136,138,140],{"key":20,"text":135,"correct":22},"焊接钢管",{"key":24,"text":137,"correct":22},"螺旋缝翱够",{"key":27,"text":139,"correct":22},"高压无缝钢管",{"key":31,"text":141,"correct":29},"螺旋缝钢管",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":20,"analysis":33},1252829,"室内电缆敷设程序中电缆管加工与敷设的紧后工序是",[146,148,150,152],{"key":20,"text":147,"correct":29},"电缆牌制作",{"key":24,"text":149,"correct":22},"电缆电气试验",{"key":27,"text":151,"correct":22},"电缆沟接地线安装",{"key":31,"text":153,"correct":22},"电缆两端电气设备安装",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":31,"analysis":33},1252830,"直线段钢制桥架超过30m，（ ）桥架超过15m时，应留有伸缩缝或伸缩片",[158,160,162,164],{"key":20,"text":159,"correct":22},"铁制",{"key":24,"text":161,"correct":22},"钢制",{"key":27,"text":163,"correct":22},"铜制",{"key":31,"text":165,"correct":29},"铝制",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":31,"analysis":33},1252831,"有封存标志的计量器具是指（ ）的计量器具。",[170,172,174,176],{"key":20,"text":171,"correct":22},"有严重缺损",{"key":24,"text":173,"correct":22},"检定不合格",{"key":27,"text":175,"correct":22},"落后淘汰",{"key":31,"text":177,"correct":29},"暂停使用",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":20,"analysis":33},1252832,"施工单位所选用的计量器具和设备，必须具有产品合格证或（ ）",[182,184,186,188],{"key":20,"text":183,"correct":29},"技术鉴定书",{"key":24,"text":185,"correct":22},"产品说明书",{"key":27,"text":187,"correct":22},"制造许可证",{"key":31,"text":189,"correct":22},"使用规范",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":20,"analysis":33},1252833,"工程竣工后的建筑消防验收，应检查其消防设施配置是否符合（ ）的要求。",[194,196,198,200],{"key":20,"text":195,"correct":29},"已获审核批准的消防设计",{"key":24,"text":197,"correct":22},"工程可投入使用或生产",{"key":27,"text":199,"correct":22},"建筑防火等级标准",{"key":31,"text":201,"correct":22},"公安消防部门管理",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":31,"analysis":33},1252834,"项目成本管理应遵循的程序不包括：（ ）。",[206,208,210,212],{"key":20,"text":207,"correct":22},"掌握生产要素的市场价格的变动状态",{"key":24,"text":209,"correct":22},"确定项目合同价",{"key":27,"text":211,"correct":22},"编制成本计划，确定成本实施目标",{"key":31,"text":213,"correct":29},"材料管理考核",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":27,"analysis":33},1252835,"在整装锅炉的技术安装要点中，放线复检锅炉基础时应注意快装锅炉条形基础平面倾斜度为",[218,220,222,224],{"key":20,"text":219,"correct":22},"1：15",{"key":24,"text":221,"correct":22},"1：20",{"key":27,"text":223,"correct":29},"1：25",{"key":31,"text":225,"correct":22},"1：30",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":20,"analysis":33},1252836,"项目资源管理的全过程为（ ）。",[230,232,234,236],{"key":20,"text":231,"correct":29},"项目资源计划、配置、控制和处置",{"key":24,"text":233,"correct":22},"人力资源管理、材料管理、机械设备管理、技术管理和资金管理",{"key":27,"text":235,"correct":22},"编制投资配置计划，确定投入资源的数量与时间",{"key":31,"text":237,"correct":22},"采取科学的措施，进行有效组合，合理投入，动态调控。",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":24,"analysis":33},1252837,"高压电器及成套装置的功能不包括（ ）",[242,244,246,248],{"key":20,"text":243,"correct":22},"通断",{"key":24,"text":245,"correct":29},"变压",{"key":27,"text":247,"correct":22},"保护",{"key":31,"text":249,"correct":22},"调节",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":20,"analysis":33},1252838,"采用水准仪和水准尺测定待测点与已知点之间的高差，通过计算得到待定点高程的方法是（ ）",[254,256,258,260],{"key":20,"text":255,"correct":29},"高差法",{"key":24,"text":257,"correct":22},"三边测量法",{"key":27,"text":259,"correct":22},"仪高法",{"key":31,"text":261,"correct":22},"三角测量法",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":27,"analysis":33},1252839,"当阀门与管道连接时，要求阀门在关闭状态下安装的是（ ）方式连接。",[266,268,270,272],{"key":20,"text":267,"correct":22},"电焊焊接",{"key":24,"text":269,"correct":22},"气焊焊接",{"key":27,"text":271,"correct":29},"法兰",{"key":31,"text":273,"correct":22},"热熔",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":20,"analysis":33},1252840,"不锈钢管道的吹扫和清洗方法宜采用（ ）",[278,280,282,284],{"key":20,"text":279,"correct":29},"水冲洗后空气吹干",{"key":24,"text":281,"correct":22},"蒸汽吹扫后空气吹干",{"key":27,"text":283,"correct":22},"蒸汽吹扫后进行油清洗",{"key":31,"text":285,"correct":22},"水冲洗后进行油清洗",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":27,"analysis":33},1252841,"动态式炉窑砌筑必须在（ ）合格后方可进行。",[290,292,294,296],{"key":20,"text":291,"correct":22},"炉窑壳（筒）体安装验收",{"key":24,"text":293,"correct":22},"炉窑壳（筒）体对接焊缝经无损检测",{"key":27,"text":295,"correct":29},"炉窑单机无负荷试运转验收",{"key":31,"text":297,"correct":22},"炉窑无负荷联动试运转验收",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":20,"analysis":33},1252842,"机电工程施工总承包一级企业可承包（ ）工程的施工。",[302,304,306,308],{"key":20,"text":303,"correct":29},"各类机电",{"key":24,"text":305,"correct":22},"大型机电",{"key":27,"text":307,"correct":22},"特殊机电",{"key":31,"text":309,"correct":22},"建筑机电",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":31,"analysis":33},1252843,"室内排水管道的检验试验应包括（ ）等试验。",[314,316,318,320],{"key":20,"text":315,"correct":22},"水压",{"key":24,"text":317,"correct":22},"气压",{"key":27,"text":319,"correct":22},"泄漏性",{"key":31,"text":321,"correct":29},"灌水",{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":20,"analysis":33},1252844,"将激光束置于铅直方向以进行竖向准直的仪器是",[326,328,330,332],{"key":20,"text":327,"correct":29},"激光垂线仪",{"key":24,"text":329,"correct":22},"激光经纬仪",{"key":27,"text":331,"correct":22},"激光平面仪",{"key":31,"text":333,"correct":22},"激光水准仪",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":20,"analysis":33},1252845,"高程测量常用的方法包括（ ）。",[338,340,342,343],{"key":20,"text":339,"correct":29},"水准测量法",{"key":24,"text":341,"correct":22},"流体静力水准测量法",{"key":27,"text":255,"correct":22},{"key":31,"text":259,"correct":22},{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":24,"analysis":33},1252846,"电力电容器安装工序中电容器二次搬运的紧后工序是",[348,350,352,354],{"key":20,"text":349,"correct":22},"连线",{"key":24,"text":351,"correct":29},"电容器安装",{"key":27,"text":353,"correct":22},"送电前检查",{"key":31,"text":355,"correct":22},"送电运行验收",{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":358,"options":359,"answer":24,"analysis":33},1252847,"项目经理部是为项目经理（ ）提供信息依据，当好助手。",[360,362,364,366],{"key":20,"text":361,"correct":22},"策划",{"key":24,"text":363,"correct":29},"决策",{"key":27,"text":365,"correct":22},"领导",{"key":31,"text":367,"correct":22},"指挥",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":27,"analysis":33},1252848,"建筑采暖管道穿过墙壁和楼板时应设置",[372,374,376,378],{"key":20,"text":373,"correct":22},"水泥套管",{"key":24,"text":375,"correct":22},"铸铁套管",{"key":27,"text":377,"correct":29},"金属套管",{"key":31,"text":379,"correct":22},"瓷质套管",{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":24,"analysis":33},1252849,"空调系统带冷（热）源的连续试运行时间应不少于（ ）",[384,386,388,390],{"key":20,"text":385,"correct":22},"2h",{"key":24,"text":387,"correct":29},"8h",{"key":27,"text":389,"correct":22},"12h",{"key":31,"text":391,"correct":22},"24h",{"id":393,"libraryId":5,"type":15,"typeLabel":16,"stem":394,"options":395,"answer":27,"analysis":33},1252850,"灌水试验的检验方法是，灌水到满水15min，水面下降后再灌满观察（ ），液面不降，室内排水管道的接口无渗漏为合格。",[396,398,400,402],{"key":20,"text":397,"correct":22},"1min",{"key":24,"text":399,"correct":22},"3min",{"key":27,"text":401,"correct":29},"5min",{"key":31,"text":403,"correct":22},"8min",{"id":405,"libraryId":5,"type":15,"typeLabel":16,"stem":406,"options":407,"answer":27,"analysis":33},1252851,"输送介质温度为120℃",[408,410,412,414],{"key":20,"text":409,"correct":22},"低温管道",{"key":24,"text":411,"correct":22},"常温管道",{"key":27,"text":413,"correct":29},"中温管道",{"key":31,"text":415,"correct":22},"高温管道",{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":27,"analysis":33},1252852,"粗装修消防验收属于消防设施的（ ）验收",[420,422,424,426],{"key":20,"text":421,"correct":22},"完整性",{"key":24,"text":423,"correct":22},"可用性",{"key":27,"text":425,"correct":29},"功能性",{"key":31,"text":427,"correct":22},"操作性",{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":430,"options":431,"answer":20,"analysis":33},1252853,"关于无损检测人员的要求，下列说法中错误的是（ ）",[432,434,436,438],{"key":20,"text":433,"correct":29},"工级人员可进行签发检测报告的工作",{"key":24,"text":435,"correct":22},"Ⅱ级人员可进行评定检测结果的工作",{"key":27,"text":437,"correct":22},"Ⅲ级人员可进行审核检测报告的工作",{"key":31,"text":439,"correct":22},"Ⅲ级人员可进行无损检测工艺的编制工作",{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":31,"analysis":33},1252854,"机电工程中，常用的特厚板是指厚度大于（ ）的板材。",[444,446,448,450],{"key":20,"text":445,"correct":22},"4mm",{"key":24,"text":447,"correct":22},"25mm",{"key":27,"text":449,"correct":22},"50mm",{"key":31,"text":451,"correct":29},"60mm",{"id":453,"libraryId":5,"type":15,"typeLabel":16,"stem":454,"options":455,"answer":27,"analysis":33},1252855,"下列中不属于特种设备“四方责任”的部门是",[456,458,460,462],{"key":20,"text":457,"correct":22},"生产和使用单位",{"key":24,"text":459,"correct":22},"检验检测机构",{"key":27,"text":461,"correct":29},"设计单位",{"key":31,"text":463,"correct":22},"监督部门",{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":20,"analysis":33},1252856,"管道与设备作为一个系统进行试验时，当管道的试验压力等于或小于设备的试验压力时，应按（ ）进行试验",[468,470,472,474],{"key":20,"text":469,"correct":29},"管道的试验压力",{"key":24,"text":471,"correct":22},"设备的试验压力",{"key":27,"text":473,"correct":22},"管道设计压力的1.15倍",{"key":31,"text":475,"correct":22},"设备设计压力的1.15倍",{"id":477,"libraryId":5,"type":15,"typeLabel":16,"stem":478,"options":479,"answer":24,"analysis":33},1252857,"工程项目质量检验的“三检制”不包括（ ）",[480,482,484,486],{"key":20,"text":481,"correct":22},"操作人员的自检",{"key":24,"text":483,"correct":29},"专职检验人员的终检",{"key":27,"text":485,"correct":22},"操作人员的互检",{"key":31,"text":487,"correct":22},"专职质量管理人员的专检",{"id":489,"libraryId":5,"type":15,"typeLabel":16,"stem":490,"options":491,"answer":20,"analysis":33},1252858,"有热位移的管道，吊点应设在位移的相反方向，按位移值的（ ）偏位安装",[492,494,496,498],{"key":20,"text":493,"correct":29},"1\u002F2",{"key":24,"text":495,"correct":22},"1\u002F3",{"key":27,"text":497,"correct":22},"1\u002F4",{"key":31,"text":499,"correct":22},"1\u002F5",{"id":501,"libraryId":5,"type":15,"typeLabel":16,"stem":502,"options":503,"answer":27,"analysis":33},1252859,"架空电力线路导线架设程序中，导线展放的紧后工序是（ ）",[504,506,508,510],{"key":20,"text":505,"correct":22},"紧线",{"key":24,"text":507,"correct":22},"导线固定",{"key":27,"text":509,"correct":29},"导线连接",{"key":31,"text":511,"correct":22},"跳线连接",{"id":513,"libraryId":5,"type":15,"typeLabel":16,"stem":514,"options":515,"answer":31,"analysis":33},1252860,"母线通过负荷电流或短路电流时产生发热的胀伸能沿本身的中心方向",[516,518,520,522],{"key":20,"text":517,"correct":22},"上下移动",{"key":24,"text":519,"correct":22},"左右移动",{"key":27,"text":521,"correct":22},"垂直移动",{"key":31,"text":523,"correct":29},"自由移动",{"id":525,"libraryId":5,"type":15,"typeLabel":16,"stem":526,"options":527,"answer":27,"analysis":33},1252861,"进行高电压试验时，操作人员与高电压回路间应该具有足够的安全距离。如电压等级为6-10kV，不设防护栅时，最小安全距离为（",[528,530,532,534],{"key":20,"text":529,"correct":22},"1m",{"key":24,"text":531,"correct":22},"0.5m",{"key":27,"text":533,"correct":29},"0.7m",{"key":31,"text":535,"correct":22},"1.2m",{"id":537,"libraryId":5,"type":15,"typeLabel":16,"stem":538,"options":539,"answer":27,"analysis":33},1252862,"《电力法》对在电力设施保护区域内施工作业的规定，说法错误的是（ ）。",[540,542,544,546],{"key":20,"text":541,"correct":22},"制定电力设施保护区施工方案前先要摸清周边电力设施的实情",{"key":24,"text":543,"correct":22},"电力管理部门应当对电力设施保护区设立标志",{"key":27,"text":545,"correct":29},"在电力设施保护区域内施工作业.往往发生在建设项目红线范围内",{"key":31,"text":547,"correct":22},"电力设施保护区内施工方案编制完成后.报经电力管理部门批准后执行",{"id":549,"libraryId":5,"type":15,"typeLabel":16,"stem":550,"options":551,"answer":24,"analysis":33},1252863,"对设备保温层施工技术要求描述错误的一项是",[552,554,556,558],{"key":20,"text":553,"correct":22},"施工后的保温层不得覆盖设备铭牌",{"key":24,"text":555,"correct":29},"硬质或半硬质材料作保温层.拼接宽度不应大于10mm",{"key":27,"text":557,"correct":22},"用散装材料时.保温层应包扎镀锌铁丝网",{"key":31,"text":559,"correct":22},"同层保温应错缝.上下层要压缝",{"id":561,"libraryId":5,"type":15,"typeLabel":16,"stem":562,"options":563,"answer":27,"analysis":33},1252864,"焊接工艺评定应以可靠的（ ）为依据，并在工程施焊之前完成。",[564,566,568,570],{"key":20,"text":565,"correct":22},"焊接工艺",{"key":24,"text":567,"correct":22},"焊接技术",{"key":27,"text":569,"correct":29},"钢材焊接性能",{"key":31,"text":571,"correct":22},"焊接材料性能",{"id":573,"libraryId":5,"type":15,"typeLabel":16,"stem":574,"options":575,"answer":31,"analysis":33},1252865,"防雷接地模块的安装要满足有关规范的规定，通常接地模块顶面埋深不应小于（",[576,578,580,581],{"key":20,"text":577,"correct":22},"03m",{"key":24,"text":579,"correct":22},"0.4m",{"key":27,"text":531,"correct":22},{"key":31,"text":582,"correct":29},"0.6m",{"id":584,"libraryId":5,"type":15,"typeLabel":16,"stem":585,"options":586,"answer":27,"analysis":33},1252866,"施工项目职业健康安全（OHS）管理的目标具体不包括：（ ）。",[587,589,591,593],{"key":20,"text":588,"correct":22},"减少或消除人的不安全行为的目标",{"key":24,"text":590,"correct":22},"减少或消除设备、材料的不安全状态的目标",{"key":27,"text":592,"correct":29},"施工过程管理的目标",{"key":31,"text":594,"correct":22},"改善生产环境和保护自然环境的目标",{"id":596,"libraryId":5,"type":15,"typeLabel":16,"stem":597,"options":598,"answer":24,"analysis":33},1252867,"项目经理部直属（ ）领导，主要承担和负责现场项目管理的日常工作。",[599,601,603,605],{"key":20,"text":600,"correct":22},"施工经理",{"key":24,"text":602,"correct":29},"项目经理",{"key":27,"text":604,"correct":22},"分公司经理",{"key":31,"text":606,"correct":22},"总经理",{"id":608,"libraryId":5,"type":15,"typeLabel":16,"stem":609,"options":610,"answer":31,"analysis":33},1252868,"关于工业非金属管道安装技术要求，下列说法中错误的是（ ）",[611,613,615,617],{"key":20,"text":612,"correct":22},"应尽量避免恶劣环境下施工题",{"key":24,"text":614,"correct":22},"电熔连接和热熔连接时，连接机具工作环境温度应在10~40℃之间",{"key":27,"text":616,"correct":22},"缠绕连接时，环境温度不宜低于5℃",{"key":31,"text":618,"correct":29},"密封圈承插连接时必须使用硬化处理的橡胶圈",[620,623,626,629,632,635],{"id":15,"name":621,"category":7,"favorite":622},"领导干部任职前廉政法规知识测试题",92,{"id":624,"name":625,"category":7,"favorite":15},595,"建筑结构与设备",{"id":627,"name":628,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":630,"name":631,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":633,"name":634,"category":7,"favorite":8},534,"BIM工程师",{"id":636,"name":634,"category":7,"favorite":8},535]