[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-818-5":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":582},{"id":5,"name":6,"category":7,"favorite":8},818,"(标准员)专业管理实务 岗位知识","建筑工程",0,5,50,1147,[13,34,46,58,70,82,94,106,118,130,142,154,165,177,185,197,209,221,233,241,253,265,277,289,300,312,324,336,344,356,368,379,387,397,409,421,431,443,451,463,472,484,496,508,518,526,534,546,558,570],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},1157952,1,"单选题","根据《屋面工程质量验收规范》GB50207-2012，保温材料的（ ）、表观密度或干密度、抗压强度或压缩强度、燃烧性能，必须符合设计要求。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","化学成分",false,{"key":24,"text":25,"correct":22},"B","厚度",{"key":27,"text":28,"correct":22},"C","尺寸",{"key":30,"text":31,"correct":32},"D","导热系数",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":27,"analysis":33},1157953,"标准编号为GB50092-96是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"建筑工程施工质量验收统一标准",{"key":24,"text":41,"correct":22},"烟囱工程施工及验收规范",{"key":27,"text":43,"correct":32},"沥青路面施工及验收规范",{"key":30,"text":45,"correct":22},"水泥混凝土路面施工及验收规范",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},1157954,"标准编号为GB50119-2013是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"滑动模板工程技术规范",{"key":24,"text":53,"correct":32},"混凝土外加剂应用技术规范",{"key":27,"text":55,"correct":22},"混凝土质量控制标准",{"key":30,"text":57,"correct":22},"钢筋混凝土升板结构技术规范",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},1157955,"根据《大体积混凝土施工规范》CJB50496-2009，炎热天气浇筑大体积混凝土时，宜采用遮盖、洒水、拌冰屑等降低混凝土原材料温度的措施，混凝土人模温度宜控制在（ ）以下。",[62,64,66,68],{"key":20,"text":63,"correct":32},"30℃",{"key":24,"text":65,"correct":22},"25℃",{"key":27,"text":67,"correct":22},"35℃",{"key":30,"text":69,"correct":22},"20℃",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},1157956,"根据《电梯工程施工质量验收规范》GB50310-2002，固定悬挂装置、随行电缆、补偿装置绳头组合必须安全可靠，且每个绳头组合必须安装（ ）的装置。",[74,76,78,80],{"key":20,"text":75,"correct":22},"防绳头起火",{"key":24,"text":77,"correct":32},"防螺母松动和脱落",{"key":27,"text":79,"correct":22},"防绳头松开",{"key":30,"text":81,"correct":22},"防摆动",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":27,"analysis":33},1157958,"根据《建筑工程施工质量验收统一标准》GB50300-2013，单位工程完工后，施工单位应组织有关人员进行自检。总监理工程师应组织各专业监理工程师对工程质量进行竣工预验收。存在施工质量问题时，应由施工单位整改。整改完毕后，由（ ）向建设单位提交工程竣工报告，申请工程竣工验收。",[86,88,90,92],{"key":20,"text":87,"correct":22},"设计单位",{"key":24,"text":89,"correct":22},"监理单位",{"key":27,"text":91,"correct":32},"施工单位",{"key":30,"text":93,"correct":22},"勘察单位项目负责人",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":27,"analysis":33},1157959,"根据《建筑机械使用安全技术规程》JGJ33-2012，建筑起重机的变幅限制器、力矩限制器、（ ）以及各种行程限位开关等安全保护装置，应完好齐全、灵敏可靠，不得随意调整或拆除。严禁利用限制器和限位装置代替操纵机构。",[98,100,102,104],{"key":20,"text":99,"correct":22},"安全绳",{"key":24,"text":101,"correct":22},"安全带",{"key":27,"text":103,"correct":32},"重量限制器",{"key":30,"text":105,"correct":22},"支腿",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":20,"analysis":33},1157960,"根据《城镇道路工程施工与质量验收规范》CJJ1-2008，施工中必须建立安全皮术交底制度，并对作业人员进行相关的安全技术教育与培训。作业前（ ）人员必须向作业人员进行详尽的安全技术交底，并形成文件。",[110,112,114,116],{"key":20,"text":111,"correct":32},"主管施工技术",{"key":24,"text":113,"correct":22},"项目经理",{"key":27,"text":115,"correct":22},"生产经理",{"key":30,"text":117,"correct":22},"施工员",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},1157961,"根据《建筑施工升降机安装、使用、拆卸安全技术规程》JGJ215-2010，严禁用（ ）作为停止运行的控制开关。",[122,124,126,128],{"key":20,"text":123,"correct":22},"漏电保护器",{"key":24,"text":125,"correct":32},"行程限位开关",{"key":27,"text":127,"correct":22},"传感器",{"key":30,"text":129,"correct":22},"变幅限位器",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":24,"analysis":33},1157962,"根据《通风与空调工程施工质量验收规范》GB50243-2002，防火风管的本体、框架与固定材料、密封垫料必须为（ ），其耐火等级应符合设计的规定。",[134,136,138,140],{"key":20,"text":135,"correct":22},"可燃材料",{"key":24,"text":137,"correct":32},"不燃材料",{"key":27,"text":139,"correct":22},"易燃材料",{"key":30,"text":141,"correct":22},"难燃材料",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":20,"analysis":33},1157963,"（ ）是企业在同一验收规范的尺度下进行竞争的法宝。",[146,148,150,152],{"key":20,"text":147,"correct":32},"施工技术规范",{"key":24,"text":149,"correct":22},"企业标准",{"key":27,"text":151,"correct":22},"企业管理规范",{"key":30,"text":153,"correct":22},"施工标准",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":27,"analysis":33},1157964,"根据《建筑工程施工质量验收统一标准》GB50300-2013，检验批应由（ ）组织施工单位项目专业质量检查员、专业工长等进行验收。",[158,159,161,163],{"key":20,"text":113,"correct":22},{"key":24,"text":160,"correct":22},"项目技术负责人",{"key":27,"text":162,"correct":32},"专业监理工程师",{"key":30,"text":164,"correct":22},"总监理工程师",{"id":166,"libraryId":5,"type":15,"typeLabel":16,"stem":167,"options":168,"answer":30,"analysis":33},1157965,"根据《大体积混凝土施工规范》GB50496-2009，超长大体积混凝土采用跳仓法施工施工时，跳仓的最大分块尺寸不宜大于（ ）。",[169,171,173,175],{"key":20,"text":170,"correct":22},"45m",{"key":24,"text":172,"correct":22},"35m",{"key":27,"text":174,"correct":22},"30m",{"key":30,"text":176,"correct":32},"40m",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":30,"analysis":33},1157966,"标准编号为GBJ97-87是（ ）。",[181,182,183,184],{"key":20,"text":39,"correct":22},{"key":24,"text":41,"correct":22},{"key":27,"text":43,"correct":22},{"key":30,"text":45,"correct":32},{"id":186,"libraryId":5,"type":15,"typeLabel":16,"stem":187,"options":188,"answer":24,"analysis":33},1157967,"根据《施工现场临时用电安全技术规范》JGJ46-2005，对夜间影响飞机或车辆通行的在建工程及机械设备，必须设置醒目的红色信号灯，其电源应设在施工现场总电源开关的（ ），并应设置外电线路停止供电时的应急自备电源。",[189,191,193,195],{"key":20,"text":190,"correct":22},"后侧",{"key":24,"text":192,"correct":32},"前侧",{"key":27,"text":194,"correct":22},"左侧",{"key":30,"text":196,"correct":22},"右侧",{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":27,"analysis":33},1157968,"根据《建筑施工升降机安装、使用、拆卸安全技术规程》JGJ215-2010，严禁施工升降机使用超过（ ）的防坠安全器。",[201,203,205,207],{"key":20,"text":202,"correct":22},"15年",{"key":24,"text":204,"correct":22},"有效期",{"key":27,"text":206,"correct":32},"有效标定期",{"key":30,"text":208,"correct":22},"20年",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":20,"analysis":33},1157969,"模板及其支架应根据施工过程中的各种工况进行设计，应具有足够的承载力和（ ），并应保证其整体稳固性。",[213,215,217,219],{"key":20,"text":214,"correct":32},"刚度",{"key":24,"text":216,"correct":22},"强度",{"key":27,"text":218,"correct":22},"挠度",{"key":30,"text":220,"correct":22},"内力",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":27,"analysis":33},1157970,"根据《地下防水工程质量验收规范》GB50208-2011，涂料防水层的平均厚度应符合设计要求，最小厚度不得小于设计厚度的（ ）。",[225,227,229,231],{"key":20,"text":226,"correct":22},"60％",{"key":24,"text":228,"correct":22},"70％",{"key":27,"text":230,"correct":32},"80％",{"key":30,"text":232,"correct":22},"90％",{"id":234,"libraryId":5,"type":15,"typeLabel":16,"stem":235,"options":236,"answer":24,"analysis":33},1157971,"根据《通风与空调工程施工质量验收规范》GB50243-2002，复合材料风管的覆面材料必须为（ ），内部的绝热材料应为不燃或难燃B1级，且对人体无害的材料。",[237,238,239,240],{"key":20,"text":135,"correct":22},{"key":24,"text":137,"correct":32},{"key":27,"text":139,"correct":22},{"key":30,"text":141,"correct":22},{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":30,"analysis":33},1157972,"根据《施工现场临时用电安全技术规范》JGJ46-2005，开关箱中漏电保护器的额定漏电动作电流不应大于（ ）。",[245,247,249,251],{"key":20,"text":246,"correct":22},"10A",{"key":24,"text":248,"correct":22},"10mA",{"key":27,"text":250,"correct":22},"30A",{"key":30,"text":252,"correct":32},"30mA",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":24,"analysis":33},1157973,"根据《施工现场临时用电安全技术规范》JGJ46-2005，对配电箱、开关箱进行定期维修、检查时，必须将其（ ）分闸断电，并悬挂“禁止合闸、有人工作\\\"停电标志牌，严禁带电作业。",[257,259,261,263],{"key":20,"text":258,"correct":22},"总电源隔离开关",{"key":24,"text":260,"correct":32},"前一级相应的电源隔离开关",{"key":27,"text":262,"correct":22},"最后一级相应的电源隔离开关",{"key":30,"text":264,"correct":22},"三级电源隔离开关",{"id":266,"libraryId":5,"type":15,"typeLabel":16,"stem":267,"options":268,"answer":27,"analysis":33},1157974,"根据《砌体结构工程施工质量验收规范》GB50203-2011，正常施工条件下，砖砌体、小砌块砌体每日砌筑高度宜控制在（ ）或一步脚手架高度内。",[269,271,273,275],{"key":20,"text":270,"correct":22},"1.8m",{"key":24,"text":272,"correct":22},"2.0m",{"key":27,"text":274,"correct":32},"1.5m",{"key":30,"text":276,"correct":22},"1.2m",{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":30,"analysis":33},1157975,"根据《建筑施工扣件式钢管脚手架安全技术规范》JGJ130-2011，开口型脚手架的两端必须设置连墙件，连墙件的垂直间距不应大于建筑物的（ ），并且不应大于4m。",[281,283,285,287],{"key":20,"text":282,"correct":22},"1\u002F5层高",{"key":24,"text":284,"correct":22},"1\u002F3层高",{"key":27,"text":286,"correct":22},"1\u002F2层高",{"key":30,"text":288,"correct":32},"层高",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":27,"analysis":33},1157976,"根据《建筑工程施工质量验收统一标准》GB50300-2013，经返修或加固处理仍不能满足（ ）或重要使用功能的分部工程及单位工程，严禁验收。",[293,294,296,298],{"key":20,"text":28,"correct":22},{"key":24,"text":295,"correct":22},"标高",{"key":27,"text":297,"correct":32},"安全",{"key":30,"text":299,"correct":22},"重量",{"id":301,"libraryId":5,"type":15,"typeLabel":16,"stem":302,"options":303,"answer":30,"analysis":33},1157977,"根据《混凝土结构工程施工规范》GB50666-2011，原材料进场复验应符合下列规定：应对水泥的强度、安定性、凝结时间及其他必要指标进行检验。同一生产厂家、同一品种、同一等级且连续进场的水泥散装不超过（ ）为一检验批。",[304,306,308,310],{"key":20,"text":305,"correct":22},"20t",{"key":24,"text":307,"correct":22},"100t",{"key":27,"text":309,"correct":22},"200t",{"key":30,"text":311,"correct":32},"500t",{"id":313,"libraryId":5,"type":15,"typeLabel":16,"stem":314,"options":315,"answer":27,"analysis":33},1157978,"根据《施工现场临时用电安全技术规范》JGJ46-2005第1.0.3条规定，建筑施工现场临时用电做法错误的是（ ）。",[316,318,320,322],{"key":20,"text":317,"correct":22},"采用三级配电系统",{"key":24,"text":319,"correct":22},"采用TN-s接零保护系统",{"key":27,"text":321,"correct":32},"采用三级漏电保护系统",{"key":30,"text":323,"correct":22},"采用二级漏电保护系统",{"id":325,"libraryId":5,"type":15,"typeLabel":16,"stem":326,"options":327,"answer":24,"analysis":33},1157979,"根据《混凝土结构工程施工质量验收规范》GB50204-2015，混凝土的强度等级必须符合设计要求。用于检验混凝土强度的试件应在（ ）随机抽取。",[328,330,332,334],{"key":20,"text":329,"correct":22},"搅拌机出料口",{"key":24,"text":331,"correct":32},"浇筑地点",{"key":27,"text":333,"correct":22},"混凝土搅拌运输车出料口",{"key":30,"text":335,"correct":22},"混凝土输送泵进料口",{"id":337,"libraryId":5,"type":15,"typeLabel":16,"stem":338,"options":339,"answer":27,"analysis":33},1157980,"标准编号为GB50164-2011是（ ）。",[340,341,342,343],{"key":20,"text":51,"correct":22},{"key":24,"text":53,"correct":22},{"key":27,"text":55,"correct":32},{"key":30,"text":57,"correct":22},{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":24,"analysis":33},1157981,"标准编号为GB50156-2012是（ ）。",[348,350,352,354],{"key":20,"text":349,"correct":22},"粉煤灰混凝土应用技术规范",{"key":24,"text":351,"correct":32},"汽车加油加气站设计与施工规范",{"key":27,"text":353,"correct":22},"蓄滞洪区建筑工程技术规范",{"key":30,"text":355,"correct":22},"建设工程施工现场供电安全规范",{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":358,"options":359,"answer":27,"analysis":33},1157982,"根据《施工现场临时用电安全技术规范》JGJ46-2005，电缆中必须包含全部工作芯线和用作保护零线或保护线的芯线。需要三相四线制配电的电缆线路必须采（ ）。",[360,362,364,366],{"key":20,"text":361,"correct":22},"2芯电缆+3芯电缆",{"key":24,"text":363,"correct":22},"四芯电缆",{"key":27,"text":365,"correct":32},"五芯电缆",{"key":30,"text":367,"correct":22},"二根电缆",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":20,"analysis":33},1157983,"根据《大体积混凝土施工规范》GB50496-2009，混凝土结构物实体最小几何尺寸不小于（ ）的大体量混凝土，或预计会因混凝土中胶凝材料水化引起的温度变化和收缩而导致有害裂缝产生的混凝土。",[372,374,376,377],{"key":20,"text":373,"correct":32},"1m",{"key":24,"text":375,"correct":22},"0.8m",{"key":27,"text":276,"correct":22},{"key":30,"text":378,"correct":22},"0.9m",{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":381,"options":382,"answer":20,"analysis":33},1157984,"根据《电梯工程施工质量验收规范》GB50310-2002，电梯安装之前，所有层门预留孔必须设有高度不小于（ ）的安全保护围封，并应保证有足够的强度。",[383,384,385,386],{"key":20,"text":276,"correct":32},{"key":24,"text":274,"correct":22},{"key":27,"text":270,"correct":22},{"key":30,"text":272,"correct":22},{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":389,"options":390,"answer":27,"analysis":33},1157985,"根据《建筑施工组织设计规范》GB\u002FT50502-2009，施工组织总设计应由（ ）审批。",[391,392,394,396],{"key":20,"text":113,"correct":22},{"key":24,"text":393,"correct":22},"业主单位技术负责人",{"key":27,"text":395,"correct":32},"总承包单位技术负责人",{"key":30,"text":160,"correct":22},{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":20,"analysis":33},1157986,"根据《屋面工程质量验收规范》GB50207-2012，屋面工程所用的防水、保温材料产品质量应由（ ）建设行政主管部门对其资质认可和质量技术监督部门对其计量认证的质量检测单位检测。",[401,403,405,407],{"key":20,"text":402,"correct":32},"省级以上",{"key":24,"text":404,"correct":22},"市级以上",{"key":27,"text":406,"correct":22},"建设部",{"key":30,"text":408,"correct":22},"委托部门",{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":411,"options":412,"answer":27,"analysis":33},1157987,"根据《施工现场临时用电安全技术规范》JGJ46-2005，在建工程周边有架空线路时，当外电线路电压等级在1~10kV时，在建工程（含脚手架）的周边与架空线路的边线之间的最小安全操作距离为（ ）。",[413,415,417,419],{"key":20,"text":414,"correct":22},"10m",{"key":24,"text":416,"correct":22},"5m",{"key":27,"text":418,"correct":32},"6m",{"key":30,"text":420,"correct":22},"4m",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":20,"analysis":33},1157988,"根据《建筑施工工具式脚手架安全技术规范》JGJ202-2010，附着式升降脚手架直线布置的架体支承跨度不应大于（ ）。",[425,427,428,430],{"key":20,"text":426,"correct":32},"7m",{"key":24,"text":418,"correct":22},{"key":27,"text":429,"correct":22},"8m",{"key":30,"text":414,"correct":22},{"id":432,"libraryId":5,"type":15,"typeLabel":16,"stem":433,"options":434,"answer":30,"analysis":33},1157989,"根据《建筑机械使用安全技术规程》JGJ33-2012，机械必须按照出厂使用说明书规定的技术性能、承载能力和使用条件，正确操作，合理使用，严禁（ ）、超速作业或任意扩大使用范围。",[435,437,439,441],{"key":20,"text":436,"correct":22},"不挂安全绳",{"key":24,"text":438,"correct":22},"不挂安全带",{"key":27,"text":440,"correct":22},"换驾驶员",{"key":30,"text":442,"correct":32},"超载",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":20,"analysis":33},1157990,"标准编号为GB50300-2013是（ ）。",[447,448,449,450],{"key":20,"text":39,"correct":32},{"key":24,"text":41,"correct":22},{"key":27,"text":43,"correct":22},{"key":30,"text":45,"correct":22},{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":453,"options":454,"answer":30,"analysis":33},1157991,"根据《大体积混凝土施工规范》GB50496-2009，冬期浇筑大体积混凝土时，冬期浇筑混凝土，宜采用热水拌合、加热骨料等提高混凝土原材料温度的措施，混凝土人模温度不宜低于（ ）。",[455,457,459,461],{"key":20,"text":456,"correct":22},"-5℃",{"key":24,"text":458,"correct":22},"0℃",{"key":27,"text":460,"correct":22},"3℃",{"key":30,"text":462,"correct":32},"5℃",{"id":464,"libraryId":5,"type":15,"typeLabel":16,"stem":465,"options":466,"answer":27,"analysis":33},1157992,"根据《建筑机械使用安全技术规程》JGJ33-2012，建筑机械上的各种安全防护及（ ）和各种安全信息装置必须齐全有效。",[467,468,469,471],{"key":20,"text":99,"correct":22},{"key":24,"text":101,"correct":22},{"key":27,"text":470,"correct":32},"保险装置",{"key":30,"text":105,"correct":22},{"id":473,"libraryId":5,"type":15,"typeLabel":16,"stem":474,"options":475,"answer":30,"analysis":33},1157993,"根据《混凝土质量控制标准》GB50164-2011，混凝土施工养护时间，对于采用粉煤灰硅酸盐水泥、火山灰质硅酸盐水泥、复合硅酸盐水泥配制的混凝土，或掺加缓凝剂的混疑土以及大掺量矿物掺合料混凝土，采用浇水和潮湿覆盖的养护时间不得少于（ ）。",[476,478,480,482],{"key":20,"text":477,"correct":22},"5d",{"key":24,"text":479,"correct":22},"10d",{"key":27,"text":481,"correct":22},"7d",{"key":30,"text":483,"correct":32},"14d",{"id":485,"libraryId":5,"type":15,"typeLabel":16,"stem":486,"options":487,"answer":24,"analysis":33},1157994,"标准编号为GB50290-98是（ ）。",[488,490,492,494],{"key":20,"text":489,"correct":22},"组合钢模板技术规范",{"key":24,"text":491,"correct":32},"土工合成材料应用技术规范",{"key":27,"text":493,"correct":22},"管井技术规范",{"key":30,"text":495,"correct":22},"住宅装饰装修施工规范",{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":27,"analysis":33},1157995,"标准编号为GB50108-2008是（ ）。",[500,502,504,506],{"key":20,"text":501,"correct":22},"冷弯薄壁型钢结构技术规范",{"key":24,"text":503,"correct":22},"锚杆喷射混凝土支护技术规范",{"key":27,"text":505,"correct":32},"地下工程防水技术规范",{"key":30,"text":507,"correct":22},"膨胀土地区建筑技术规范",{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":24,"analysis":33},1157996,"根据《建筑施工工具式脚手架安全技术规范》JGJ202-2010，附着式升降脚手架架体宽度不应大于（ ）。",[512,513,514,516],{"key":20,"text":274,"correct":22},{"key":24,"text":276,"correct":32},{"key":27,"text":515,"correct":22},"108m",{"key":30,"text":517,"correct":22},"1.0m",{"id":519,"libraryId":5,"type":15,"typeLabel":16,"stem":520,"options":521,"answer":24,"analysis":33},1157997,"标准编号为GB50078-2008是（ ）。",[522,523,524,525],{"key":20,"text":39,"correct":22},{"key":24,"text":41,"correct":32},{"key":27,"text":43,"correct":22},{"key":30,"text":45,"correct":22},{"id":527,"libraryId":5,"type":15,"typeLabel":16,"stem":528,"options":529,"answer":20,"analysis":33},1157998,"标准编号为GB\u002FT50214-2013是（ ）。",[530,531,532,533],{"key":20,"text":489,"correct":32},{"key":24,"text":491,"correct":22},{"key":27,"text":493,"correct":22},{"key":30,"text":495,"correct":22},{"id":535,"libraryId":5,"type":15,"typeLabel":16,"stem":536,"options":537,"answer":30,"analysis":33},1157999,"根据《城镇道路工程施工与质量验收规范》CJJ1-200&土方路基施工，机械作业时，配合作业人员（ ）。",[538,540,542,544],{"key":20,"text":539,"correct":22},"应该佩戴安全帽才能在机械作业和走行范围内作业",{"key":24,"text":541,"correct":22},"应该采取隔离措施才能在机械作业和走行范围内作业",{"key":27,"text":543,"correct":22},"应该在有专人监护时才能在机械作业和走行范围内作业",{"key":30,"text":545,"correct":32},"严禁处在机械作业和走行范围内",{"id":547,"libraryId":5,"type":15,"typeLabel":16,"stem":548,"options":549,"answer":30,"analysis":33},1158000,"某住宅楼建设项目，现场施工进入最后的配件安装阶段。楼梯栏杆的安装工入搬运配件刚刚进入从单元入口进入地下室时，由于光线突然变暗，致使工入不小心而从楼梯平台坠落到地下一层，造成大腿骨折的重伤事故。结合事故分析回答下列问题： 2.除了背景中提到的光线突然变暗这-因素外，试分析造成这-事故的其他因素还有（ ）。",[550,552,554,556],{"key":20,"text":551,"correct":22},"工入施工操作技能素质",{"key":24,"text":553,"correct":22},"工入的身体素质",{"key":27,"text":555,"correct":22},"设计图纸缺陷",{"key":30,"text":557,"correct":32},"安全员隐患检查不到位",{"id":559,"libraryId":5,"type":15,"typeLabel":16,"stem":560,"options":561,"answer":30,"analysis":33},1158002,"根据《建筑施工扣件式钢管脚手架安全技术规范》JGJ130-2011，脚手架立杆基础不在同一高度上时，必须将（ ）延长两跨与立杆固定，高低差不应大于1m。",[562,564,566,568],{"key":20,"text":563,"correct":22},"另外加扣件",{"key":24,"text":565,"correct":22},"另外加纵向扫地杆",{"key":27,"text":567,"correct":22},"低处的纵向扫地杆向高处",{"key":30,"text":569,"correct":32},"高处的纵向扫地杆向低处",{"id":571,"libraryId":5,"type":15,"typeLabel":16,"stem":572,"options":573,"answer":27,"analysis":33},1158003,"某检验批混凝土试块强度值不满足规范要求，在法定检测单位对混凝土实体采用作破损检验等方法测定，其实际强度已达规范允许和设计要求值时，这种质量问题的处理昔施可采取（ ）。",[574,576,578,580],{"key":20,"text":575,"correct":22},"修补处理",{"key":24,"text":577,"correct":22},"返工处理",{"key":27,"text":579,"correct":32},"不做处理",{"key":30,"text":581,"correct":22},"不作为质量问题记录",[583,586,589,592,595,598],{"id":15,"name":584,"category":7,"favorite":585},"领导干部任职前廉政法规知识测试题",92,{"id":587,"name":588,"category":7,"favorite":15},595,"建筑结构与设备",{"id":590,"name":591,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":593,"name":594,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":596,"name":597,"category":7,"favorite":8},534,"BIM工程师",{"id":599,"name":597,"category":7,"favorite":8},535]