[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-804-23":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":729},{"id":5,"name":6,"category":7,"favorite":8},804,"一建通信与广电工程实务","建筑工程",0,23,50,1173,[13,38,53,67,81,95,110,124,139,154,168,183,198,212,224,238,252,265,279,293,307,321,336,350,364,378,392,406,420,434,448,463,477,492,506,520,535,549,563,577,591,606,618,631,645,659,673,687,701,715],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},1153390,2,"多选题","卫星通信线路由（）组成。",[19,23,26,30,33],{"key":20,"text":21,"correct":22},"A","发端地球站",true,{"key":24,"text":25,"correct":22},"B","卫星转发器",{"key":27,"text":28,"correct":29},"C","微波站",false,{"key":31,"text":32,"correct":22},"D","上行传播路径",{"key":34,"text":35,"correct":22},"E","下行传播路径","ABDE","",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":52,"analysis":37},1153391,"卫星通信系统的最大特点是多址工作方式，常用的有（）。",[42,44,46,48,50],{"key":20,"text":43,"correct":22},"频分多址",{"key":24,"text":45,"correct":22},"时分多址",{"key":27,"text":47,"correct":22},"空分多址",{"key":31,"text":49,"correct":22},"码分多址",{"key":34,"text":51,"correct":29},"波分多址","ABCD",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":52,"analysis":37},1153392,"VSAT网络主要由（）组成。",[57,59,61,63,65],{"key":20,"text":58,"correct":22},"通信卫星",{"key":24,"text":60,"correct":22},"网络控制中心",{"key":27,"text":62,"correct":22},"主站",{"key":31,"text":64,"correct":22},"用户",{"key":34,"text":66,"correct":29},"本地操作控制台（LOC）",{"id":68,"libraryId":5,"type":15,"typeLabel":16,"stem":69,"options":70,"answer":36,"analysis":37},1153393,"4G关键技术有（）。",[71,73,75,77,79],{"key":20,"text":72,"correct":22},"正交频分复用",{"key":24,"text":74,"correct":22},"多输入输出",{"key":27,"text":76,"correct":29},"接力软切换",{"key":31,"text":78,"correct":22},"智能天线",{"key":34,"text":80,"correct":22},"基于IP的核心网",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":52,"analysis":37},1153394,"4G蜂窝移动通信网络的主要特征包括（）。",[85,87,89,91,93],{"key":20,"text":86,"correct":22},"提供更高的传输速率",{"key":24,"text":88,"correct":22},"支持更高的终端移动速度（250km／h）",{"key":27,"text":90,"correct":22},"全IP网络架构、承载与控制分离",{"key":31,"text":92,"correct":22},"提供无处不在的服务、异构网络协同",{"key":34,"text":94,"correct":29},"提供手机电视业务",{"id":96,"libraryId":5,"type":15,"typeLabel":16,"stem":97,"options":98,"answer":109,"analysis":37},1153395,"5G网络架构将引入全新的网络技术，（）将成为5G网络的重要特征。",[99,101,103,105,107],{"key":20,"text":100,"correct":22},"SDN",{"key":24,"text":102,"correct":22},"NFV",{"key":27,"text":104,"correct":29},"IP",{"key":31,"text":106,"correct":29},"SDH",{"key":34,"text":108,"correct":29},"WDM","AB",{"id":111,"libraryId":5,"type":15,"typeLabel":16,"stem":112,"options":113,"answer":36,"analysis":37},1153396,"通信电源系统集中供电方式由（）组成。",[114,116,118,120,122],{"key":20,"text":115,"correct":22},"交流供电系统",{"key":24,"text":117,"correct":22},"直流供电系统",{"key":27,"text":119,"correct":29},"机房照明系统",{"key":31,"text":121,"correct":22},"接地系统",{"key":34,"text":123,"correct":22},"集中监控系统",{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":138,"analysis":37},1153397,"蓄电池的主要指标包括（）。",[128,130,132,134,136],{"key":20,"text":129,"correct":22},"电动势",{"key":24,"text":131,"correct":29},"电流",{"key":27,"text":133,"correct":22},"终了电压",{"key":31,"text":135,"correct":29},"开始电压",{"key":34,"text":137,"correct":22},"循环寿命","ACE",{"id":140,"libraryId":5,"type":15,"typeLabel":16,"stem":141,"options":142,"answer":153,"analysis":37},1153398,"2G移动通信系统主要由（）组成。",[143,145,147,149,151],{"key":20,"text":144,"correct":29},"无线基站（BTS）",{"key":24,"text":146,"correct":22},"移动交换子系统（NSS）",{"key":27,"text":148,"correct":22},"操作维护子系统（OSS）",{"key":31,"text":150,"correct":22},"基站子系统（BSS）",{"key":34,"text":152,"correct":22},"移动台（MS）","BCDE",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":153,"analysis":37},1153399,"设备通电前的检查应包括（）。",[158,160,162,164,166],{"key":20,"text":159,"correct":29},"插好架内保险和分保险",{"key":24,"text":161,"correct":22},"机架和机框内部应清洁，查看有无焊锡、芯线头、脱落的紧固件或其他异物",{"key":27,"text":163,"correct":22},"架内无断线混线，开关、旋钮、继电器、印刷电路板齐全，插接牢固",{"key":31,"text":165,"correct":22},"开关预置位置符合说明书要求",{"key":34,"text":167,"correct":22},"各接线器、连接电缆插头连接应正确、牢固、可靠",{"id":169,"libraryId":5,"type":15,"typeLabel":16,"stem":170,"options":171,"answer":182,"analysis":37},1153400,"直埋光缆线路工程中，下列情况中可以采用塑料管保护的有（）。",[172,174,176,178,180],{"key":20,"text":173,"correct":22},"穿越允许开挖路面的公路或乡村大道时",{"key":24,"text":175,"correct":29},"穿越铁路时",{"key":27,"text":177,"correct":22},"通过村镇等动土可能性较大的地段时",{"key":31,"text":179,"correct":22},"穿越有疏浚可能的沟渠时",{"key":34,"text":181,"correct":22},"穿越有挖泥可能的水塘时","ACDE",{"id":184,"libraryId":5,"type":15,"typeLabel":16,"stem":185,"options":186,"answer":197,"analysis":37},1153401,"通信局（站）的交流供电系统避雷措施应包括（）。",[187,189,191,193,195],{"key":20,"text":188,"correct":22},"当电力变压器设在站外时，宜在上方架设良导体避雷线",{"key":24,"text":190,"correct":22},"电力变压器高、低压侧均应各装一组避雷器",{"key":27,"text":192,"correct":22},"当电力变压器设在站内时，其高压电力线应采用地埋电力电缆",{"key":31,"text":194,"correct":29},"电力电缆应选用具有塑料护套的电力电缆",{"key":34,"text":196,"correct":22},"在架空电力线路与地埋电力电缆连接处应装设避雷器","ABCE",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":211,"analysis":37},1153402,"通信设备机架直流电源在供电前应检查输入端电源的（）。",[202,204,205,207,209],{"key":20,"text":203,"correct":22},"电压",{"key":24,"text":131,"correct":29},{"key":27,"text":206,"correct":29},"相序",{"key":31,"text":208,"correct":22},"极性",{"key":34,"text":210,"correct":29},"电抗","AD",{"id":213,"libraryId":5,"type":15,"typeLabel":16,"stem":214,"options":215,"answer":223,"analysis":37},1153403,"安装阀控式密封铅酸蓄电池时，应用万用表检查电池端（）。",[216,217,219,220,222],{"key":20,"text":203,"correct":22},{"key":24,"text":218,"correct":29},"电阻",{"key":27,"text":131,"correct":29},{"key":31,"text":221,"correct":29},"杂音",{"key":34,"text":208,"correct":22},"AE",{"id":225,"libraryId":5,"type":15,"typeLabel":16,"stem":226,"options":227,"answer":36,"analysis":37},1153404,"敷设电源线的基本要求包括（）。",[228,230,232,234,236],{"key":20,"text":229,"correct":22},"电源线必须采用整段线料，中间无接头",{"key":24,"text":231,"correct":22},"馈电采用铜（铝）排敷设时，铜（铝）排应平直，看不出有明显不平或锤痕",{"key":27,"text":233,"correct":29},"电源线正极应为蓝色标志，负极应为红色标志，保护地应为黄色标志",{"key":31,"text":235,"correct":22},"铜鼻子的规格必须与铜芯电源线规格一致",{"key":34,"text":237,"correct":22},"电源线连接时应保持熔丝或空气开关断开，电缆接线端子（或端头）采用绝缘材料包裹严实",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":52,"analysis":37},1153405,"网络优化主要从（）等方面来进行分析。",[242,244,246,248,250],{"key":20,"text":243,"correct":22},"掉话",{"key":24,"text":245,"correct":22},"无线接通率",{"key":27,"text":247,"correct":22},"切换",{"key":31,"text":249,"correct":22},"干扰",{"key":34,"text":251,"correct":29},"上下行速率",{"id":253,"libraryId":5,"type":15,"typeLabel":16,"stem":254,"options":255,"answer":52,"analysis":37},1153406,"网络指标从移动终端感知来讲主要有（）。",[256,258,260,262,263],{"key":20,"text":257,"correct":22},"掉话率",{"key":24,"text":259,"correct":22},"呼叫建立成功率",{"key":27,"text":261,"correct":22},"语音质量",{"key":31,"text":251,"correct":22},{"key":34,"text":264,"correct":29},"容量",{"id":266,"libraryId":5,"type":15,"typeLabel":16,"stem":267,"options":268,"answer":278,"analysis":37},1153407,"网络优化的过程实际上就是一个平衡（）之间矛盾的过程。",[269,271,272,274,276],{"key":20,"text":270,"correct":22},"覆盖",{"key":24,"text":264,"correct":22},{"key":27,"text":273,"correct":22},"质量",{"key":31,"text":275,"correct":29},"效益",{"key":34,"text":277,"correct":29},"安全","ABC",{"id":280,"libraryId":5,"type":15,"typeLabel":16,"stem":281,"options":282,"answer":138,"analysis":37},1153408,"无线网性能检验项目包括（）。",[283,285,287,289,291],{"key":20,"text":284,"correct":22},"覆盖性能",{"key":24,"text":286,"correct":29},"安全模式控制",{"key":27,"text":288,"correct":22},"保持能力",{"key":31,"text":290,"correct":29},"无线资源管理",{"key":34,"text":292,"correct":22},"服务质量",{"id":294,"libraryId":5,"type":15,"typeLabel":16,"stem":295,"options":296,"answer":211,"analysis":37},1153409,"对光纤放大器（O A）测试所使用的主要测试仪表有（）。",[297,299,301,303,305],{"key":20,"text":298,"correct":22},"光谱分析仪",{"key":24,"text":300,"correct":29},"多波长计",{"key":27,"text":302,"correct":29},"光源",{"key":31,"text":304,"correct":22},"光功率计",{"key":34,"text":306,"correct":29},"光可变衰耗器",{"id":308,"libraryId":5,"type":15,"typeLabel":16,"stem":309,"options":310,"answer":278,"analysis":37},1153410,"电缆单盘检验的主要项目有（）。",[311,313,315,317,319],{"key":20,"text":312,"correct":22},"环阻测试",{"key":24,"text":314,"correct":22},"不良线对检验",{"key":27,"text":316,"correct":22},"绝缘电阻检验",{"key":31,"text":318,"correct":29},"耐压检验",{"key":34,"text":320,"correct":29},"频响测试",{"id":322,"libraryId":5,"type":15,"typeLabel":16,"stem":323,"options":324,"answer":335,"analysis":37},1153411,"某通信机房新装五列设备机架，各列机架高度和完工后测得的垂直偏差数据如下，（）为合格的列。",[325,327,329,331,333],{"key":20,"text":326,"correct":22},"机架高度为1.8m，垂直偏差为1.5mm",{"key":24,"text":328,"correct":22},"机架高度为2m，垂直偏差为2mm",{"key":27,"text":330,"correct":29},"机架高度为2m，垂直偏差为3.5mm",{"key":31,"text":332,"correct":22},"机架高度为2.6m，垂直偏差为2.5mm",{"key":34,"text":334,"correct":29},"机架高度为2.6m，垂直偏差为3.5mm","ABD",{"id":337,"libraryId":5,"type":15,"typeLabel":16,"stem":338,"options":339,"answer":278,"analysis":37},1153412,"接地系统室外部分包括（）。",[340,342,344,346,348],{"key":20,"text":341,"correct":22},"建筑物接地",{"key":24,"text":343,"correct":22},"天线铁塔接地",{"key":27,"text":345,"correct":22},"天馈线接地",{"key":31,"text":347,"correct":29},"设备工作接地",{"key":34,"text":349,"correct":29},"机架保护接地",{"id":351,"libraryId":5,"type":15,"typeLabel":16,"stem":352,"options":353,"answer":52,"analysis":37},1153413,"基站工程参数表包含基站的（）。",[354,356,358,360,362],{"key":20,"text":355,"correct":22},"经纬度",{"key":24,"text":357,"correct":22},"天线方位角",{"key":27,"text":359,"correct":22},"天线高度",{"key":31,"text":361,"correct":22},"天线俯仰角",{"key":34,"text":363,"correct":29},"基带测试",{"id":365,"libraryId":5,"type":15,"typeLabel":16,"stem":366,"options":367,"answer":138,"analysis":37},1153414,"天馈线系统安装施工中，常用的吊装设备有（）。",[368,370,372,374,376],{"key":20,"text":369,"correct":22},"卷扬机",{"key":24,"text":371,"correct":29},"吊车",{"key":27,"text":373,"correct":22},"手推绞盘",{"key":31,"text":375,"correct":29},"升降车",{"key":34,"text":377,"correct":22},"手扳葫芦",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":36,"analysis":37},1153415,"符合微波天线馈源安装的技术要求的有（）。",[382,384,386,388,390],{"key":20,"text":383,"correct":22},"馈源极化方向和波导接口符合馈线走向的要求",{"key":24,"text":385,"correct":22},"安装方位角及俯仰角应符合工程设计规定，垂直方向和水平方位应留有调整余量",{"key":27,"text":387,"correct":29},"垂直面与中心轴线的夹角小于或等于25°",{"key":31,"text":389,"correct":22},"天线主反射面接缝平齐、均匀、光滑",{"key":34,"text":391,"correct":22},"馈线连接的接口清洁且电接触良好",{"id":393,"libraryId":5,"type":15,"typeLabel":16,"stem":394,"options":395,"answer":278,"analysis":37},1153416,"架空线路工程中，按建筑方式分类的拉线应包括（）。",[396,398,400,402,404],{"key":20,"text":397,"correct":22},"落地拉线",{"key":24,"text":399,"correct":22},"高桩拉线",{"key":27,"text":401,"correct":22},"吊板拉线",{"key":31,"text":403,"correct":29},"撑杆",{"key":34,"text":405,"correct":29},"风暴拉线",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":197,"analysis":37},1153417,"发电机组监控开通后应能实现油机的自动（）。",[410,412,414,416,418],{"key":20,"text":411,"correct":22},"启动",{"key":24,"text":413,"correct":22},"停机",{"key":27,"text":415,"correct":22},"调整输出电压",{"key":31,"text":417,"correct":29},"调整输出电流",{"key":34,"text":419,"correct":22},"调整输出频率",{"id":421,"libraryId":5,"type":15,"typeLabel":16,"stem":422,"options":423,"answer":109,"analysis":37},1153418,"通信局（站）的（），应分别对地加装避雷器。",[424,426,428,430,432],{"key":20,"text":425,"correct":22},"市电油机转换屏（或交流稳压器）的输入端",{"key":24,"text":427,"correct":22},"交流配电屏输入端的三根相线及零线",{"key":27,"text":429,"correct":29},"整流器输出端",{"key":31,"text":431,"correct":29},"不间断电源设备输出端",{"key":34,"text":433,"correct":29},"通信用空调输出端",{"id":435,"libraryId":5,"type":15,"typeLabel":16,"stem":436,"options":437,"answer":182,"analysis":37},1153419,"天馈线系统安装前需要做的工作有（）。",[438,440,442,444,446],{"key":20,"text":439,"correct":22},"所安装的天线、馈线运送到安装现场，检查有无损伤",{"key":24,"text":441,"correct":29},"检查机房内设备是否安装完毕",{"key":27,"text":443,"correct":22},"依据设计核对天线的安装位置、方位角度，确定安装方案",{"key":31,"text":445,"correct":22},"布置安装天线后方尾绳，制定安全措施，划定安装区域，设立明显标志",{"key":34,"text":447,"correct":22},"安装前要仔细检查所有的连接螺栓",{"id":449,"libraryId":5,"type":15,"typeLabel":16,"stem":450,"options":451,"answer":462,"analysis":37},1153420,"通信局（站）的馈线防雷措施应包括（）。",[452,454,456,458,460],{"key":20,"text":453,"correct":22},"天线必须安装避雷针，避雷针必须高于天线最高点的金属部分1m以上",{"key":24,"text":455,"correct":29},"天线馈线金属护套应在顶端及进入机房入口处的外侧加装保安器",{"key":27,"text":457,"correct":29},"出入微波站的电缆内芯线在进站处应作保护接地",{"key":31,"text":459,"correct":22},"在架空避雷线的支柱上严禁悬挂电话线、广播线、电视接收天线及低压架空线等",{"key":34,"text":461,"correct":22},"电源芯线在机房入口处应就近对地加装保安器","ADE",{"id":464,"libraryId":5,"type":15,"typeLabel":16,"stem":465,"options":466,"answer":36,"analysis":37},1153421,"下列关于接地装置的说法，正确的有（）。",[467,469,471,473,475],{"key":20,"text":468,"correct":22},"通信局（站）应采用联合接地方式",{"key":24,"text":470,"correct":22},"接地体埋深上端距地面应不小于0．7m",{"key":27,"text":472,"correct":29},"接地体可采用裸铝导体材料",{"key":31,"text":474,"correct":22},"接地引入线长度不宜超过30m",{"key":34,"text":476,"correct":22},"接地汇集线应设明显标志",{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":479,"options":480,"answer":491,"analysis":37},1153422,"通信设备的抗震措施应包括（）。",[481,483,485,487,489],{"key":20,"text":482,"correct":22},"通信设备顶部应与列架上梁可靠加固，设备下部应与地面加固",{"key":24,"text":484,"correct":22},"机房的承重房柱应采用“包柱子”方式与机房加固件连为一体",{"key":27,"text":486,"correct":29},"地震多发地区列架必须考虑与房柱加固",{"key":31,"text":488,"correct":29},"墙终端一侧，如是玻璃窗户无法加固时，应使用扁钢跨过窗户进行加固",{"key":34,"text":490,"correct":22},"抗震支架要求横平竖直，连接牢固","ABE",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":197,"analysis":37},1153423,"通信机房的环境要求包括（）。",[496,498,500,502,504],{"key":20,"text":497,"correct":22},"温度",{"key":24,"text":499,"correct":22},"湿度",{"key":27,"text":501,"correct":22},"防尘",{"key":31,"text":503,"correct":29},"绝缘",{"key":34,"text":505,"correct":22},"照明",{"id":507,"libraryId":5,"type":15,"typeLabel":16,"stem":508,"options":509,"answer":278,"analysis":37},1153424,"光缆线路工程中，当光缆线路无法避开雷暴严重地域时，应采用（）等防雷措施。",[510,512,514,516,518],{"key":20,"text":511,"correct":22},"消弧线保护",{"key":24,"text":513,"correct":22},"避雷针保护",{"key":27,"text":515,"correct":22},"排流线保护",{"key":31,"text":517,"correct":29},"套钢管保护",{"key":34,"text":519,"correct":29},"套塑料管保护",{"id":521,"libraryId":5,"type":15,"typeLabel":16,"stem":522,"options":523,"answer":534,"analysis":37},1153425,"波分复用设备合波器（OMU）的主要测试项目有（）。",[524,526,528,530,532],{"key":20,"text":525,"correct":29},"中心频率与偏离",{"key":24,"text":527,"correct":22},"插入损耗及偏差",{"key":27,"text":529,"correct":22},"极化相关损耗",{"key":31,"text":531,"correct":29},"抖动转移特性",{"key":34,"text":533,"correct":29},"输入抖动容限及频偏","BC",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":153,"analysis":37},1153426,"安装总配线架及各种配线架安装的基本要求包括（）。",[539,541,543,545,547],{"key":20,"text":540,"correct":29},"总配线架侧面位置应与成端电缆上线槽或上线孔洞相对应",{"key":24,"text":542,"correct":22},"跳线环安装位置应平滑、垂直整齐",{"key":27,"text":544,"correct":22},"总配线架滑梯安装应牢固可靠",{"key":31,"text":546,"correct":22},"滑轨拼接平正，滑梯滑动平稳，手闸灵敏",{"key":34,"text":548,"correct":22},"滑轨端头应安装挡头，防止滑梯滑出滑道",{"id":550,"libraryId":5,"type":15,"typeLabel":16,"stem":551,"options":552,"answer":182,"analysis":37},1153427,"机盘安装的基本要求包括（）。",[553,555,557,559,561],{"key":20,"text":554,"correct":22},"核对机盘的型号，是否与现场要求的机盘型号、性能相符",{"key":24,"text":556,"correct":29},"插盘前必须穿绝缘鞋",{"key":27,"text":558,"correct":22},"安插时应依据设计中的面板排列图进行，各种机盘要准确无误地插入子架中相应的位置",{"key":31,"text":560,"correct":22},"插盘前必须戴好防静电手环",{"key":34,"text":562,"correct":22},"有手汗者插盘前要戴手套",{"id":564,"libraryId":5,"type":15,"typeLabel":16,"stem":565,"options":566,"answer":36,"analysis":37},1153428,"设备通电过程中的检查应包括（）。",[567,569,571,573,575],{"key":20,"text":568,"correct":22},"接通机架总保险，观察有无异样情况",{"key":24,"text":570,"correct":22},"开启主电源开关，逐级接通分保险",{"key":27,"text":572,"correct":29},"加电检查时，应戴防静电手环，手环与机架接地点不应接触",{"key":31,"text":574,"correct":22},"各种信号灯、电表指示应符合要求，如有异常，应关机检查",{"key":34,"text":576,"correct":22},"个别单盘有问题，应换盘试验，确认故障原因",{"id":578,"libraryId":5,"type":15,"typeLabel":16,"stem":579,"options":580,"answer":52,"analysis":37},1153429,"微波设备搬迁前应制定详细的搬迁计划、申请停电路时间，提前做好新机房的（）准备工作。",[581,583,585,587,589],{"key":20,"text":582,"correct":22},"天馈线系统",{"key":24,"text":584,"correct":22},"电源系统",{"key":27,"text":586,"correct":22},"走线架安装",{"key":31,"text":588,"correct":22},"线缆的布放",{"key":34,"text":590,"correct":29},"通道主要指标测试",{"id":592,"libraryId":5,"type":15,"typeLabel":16,"stem":593,"options":594,"answer":605,"analysis":37},1153430,"下面关于GPS天线安装要求正确的有（）。",[595,597,599,601,603],{"key":20,"text":596,"correct":29},"上方60°范围内（至少南向45°）应无建筑物遮挡",{"key":24,"text":598,"correct":29},"离周围尺寸大于200mm的金属物体的水平距离不宜小于2500mm",{"key":27,"text":600,"correct":22},"天线应垂直安装",{"key":31,"text":602,"correct":22},"垂直度各向偏差应不超过1°",{"key":34,"text":604,"correct":29},"在垂直方向与基站天线距离没有限制","CD",{"id":607,"libraryId":5,"type":15,"typeLabel":16,"stem":608,"options":609,"answer":182,"analysis":37},1153431,"SDH设备的抖动测试项目包括（）。",[610,611,612,614,616],{"key":20,"text":533,"correct":22},{"key":24,"text":525,"correct":29},{"key":27,"text":613,"correct":22},"输出抖动",{"key":31,"text":615,"correct":22},"映射抖动和结合抖动",{"key":34,"text":617,"correct":22},"再生器抖动转移特性",{"id":619,"libraryId":5,"type":15,"typeLabel":16,"stem":620,"options":621,"answer":52,"analysis":37},1153432,"核心网网管测试项目包括（）管理功能。",[622,624,626,628,629],{"key":20,"text":623,"correct":22},"配置",{"key":24,"text":625,"correct":22},"告警",{"key":27,"text":627,"correct":22},"性能",{"key":31,"text":277,"correct":22},{"key":34,"text":630,"correct":29},"呼叫失败率",{"id":632,"libraryId":5,"type":15,"typeLabel":16,"stem":633,"options":634,"answer":36,"analysis":37},1153433,"核心网数据承载业务测试包括（）。",[635,637,639,641,643],{"key":20,"text":636,"correct":22},"下载类业务",{"key":24,"text":638,"correct":22},"电子邮件类业务",{"key":27,"text":640,"correct":29},"SVLTE方式业务",{"key":31,"text":642,"correct":22},"流媒体业务",{"key":34,"text":644,"correct":22},"VoLP类业务",{"id":646,"libraryId":5,"type":15,"typeLabel":16,"stem":647,"options":648,"answer":223,"analysis":37},1153434,"核心网可靠性测试的内容有（）。",[649,651,653,655,657],{"key":20,"text":650,"correct":22},"EPC核心网设备主备模块倒换",{"key":24,"text":652,"correct":29},"数据库备份安全测试",{"key":27,"text":654,"correct":29},"操作系统安全检查",{"key":31,"text":656,"correct":29},"分权分域管理安全检查",{"key":34,"text":658,"correct":22},"计费不准确率指标应小于十万分之一",{"id":660,"libraryId":5,"type":15,"typeLabel":16,"stem":661,"options":662,"answer":52,"analysis":37},1153435,"DT测试过程中需要显示的信息包括（）。",[663,665,667,669,671],{"key":20,"text":664,"correct":22},"服务小区",{"key":24,"text":666,"correct":22},"终端发射功率",{"key":27,"text":668,"correct":22},"数据服务质量",{"key":31,"text":670,"correct":22},"主要邻区间切换",{"key":34,"text":672,"correct":29},"基站发射功率",{"id":674,"libraryId":5,"type":15,"typeLabel":16,"stem":675,"options":676,"answer":223,"analysis":37},1153436,"属于LTEFDD路测要求的内容有（）。",[677,679,681,683,685],{"key":20,"text":678,"correct":22},"测试时间宜安排在工作日话务忙时进行",{"key":24,"text":680,"correct":29},"在城郊快速路车速应保持在40～60公里／小时",{"key":27,"text":682,"correct":29},"数据业务测试时应使用不低于12MB的数据包",{"key":31,"text":684,"correct":29},"每次测试数据业务要求持续90s，间隔10s，若出现未连接情况，应间隔10s进行下一次业务",{"key":34,"text":686,"correct":22},"FTP短呼测试每次呼叫时长100s，呼叫结束后断开，10s后重新尝试接入",{"id":688,"libraryId":5,"type":15,"typeLabel":16,"stem":689,"options":690,"answer":700,"analysis":37},1153437,"网络优化中参数调整的内容很多，从BSS侧看，主要包括（）。",[691,693,695,697,698],{"key":20,"text":692,"correct":29},"交换容量",{"key":24,"text":694,"correct":29},"中继数量",{"key":27,"text":696,"correct":22},"信道数量",{"key":31,"text":357,"correct":22},{"key":34,"text":699,"correct":22},"小区参数","CDE",{"id":702,"libraryId":5,"type":15,"typeLabel":16,"stem":703,"options":704,"answer":197,"analysis":37},1153438,"逆变器在（）情况下应启动保护电路动作并进行声、光告警。",[705,707,709,711,713],{"key":20,"text":706,"correct":22},"输入电压过高",{"key":24,"text":708,"correct":22},"输入电压过低",{"key":27,"text":710,"correct":22},"输出过压",{"key":31,"text":712,"correct":29},"输出电流过低",{"key":34,"text":714,"correct":22},"输出过流",{"id":716,"libraryId":5,"type":15,"typeLabel":16,"stem":717,"options":718,"answer":52,"analysis":37},1153439,"光缆中继段测试内容包括（）。",[719,721,723,725,727],{"key":20,"text":720,"correct":22},"线路衰减系数及传输长度",{"key":24,"text":722,"correct":22},"光纤后向散射曲线",{"key":27,"text":724,"correct":22},"光纤偏振模色散",{"key":31,"text":726,"correct":22},"对地绝缘电阻",{"key":34,"text":728,"correct":29},"串音衰耗",[730,734,737,740,743,746],{"id":731,"name":732,"category":7,"favorite":733},1,"领导干部任职前廉政法规知识测试题",92,{"id":735,"name":736,"category":7,"favorite":731},595,"建筑结构与设备",{"id":738,"name":739,"category":7,"favorite":731},715,"招标采购专业知识与法律法规",{"id":741,"name":742,"category":7,"favorite":731},848,"市政方向-通用基础",{"id":744,"name":745,"category":7,"favorite":8},534,"BIM工程师",{"id":747,"name":745,"category":7,"favorite":8},535]