[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1153428":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1153428,804,2,"多选题","设备通电过程中的检查应包括（）。",[11,15,18,22,25],{"key":12,"text":13,"correct":14},"A","接通机架总保险，观察有无异样情况",true,{"key":16,"text":17,"correct":14},"B","开启主电源开关，逐级接通分保险",{"key":19,"text":20,"correct":21},"C","加电检查时，应戴防静电手环，手环与机架接地点不应接触",false,{"key":23,"text":24,"correct":14},"D","各种信号灯、电表指示应符合要求，如有异常，应关机检查",{"key":26,"text":27,"correct":14},"E","个别单盘有问题，应换盘试验，确认故障原因","ABDE","2020版教材页码P96-100 通电检查： 1.接通列保险，检查信号系统是否正常，有无告警。 2.接通机架告警保险，观察告警信息是否正常。 3.接通机架总保险，观察有无异样情况。 4.开启主电源开关，逐级接通分保险，通过鼻闻、眼看、耳听注意有无异味、冒烟、打火和不正常的声音等现象。 5.电源开启后预热，无任何异常现象后，开启高压电源，加上高压电源应保持不跳闸。 上述机架加电过程中，应随时检查各种信号灯、电表指示是否符合规定，如有异常，应关机检查。安装机盘时，如发现个别单盘有问题，应换盘试验，确认故障原因。加电检查时，应戴防静电子环，手环与机架接地点应接触良好。",{"id":6,"name":31,"category":32,"favorite":33},"一建通信与广电工程实务","建筑工程",0]