[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1151657":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1151657,803,2,"多选题","下列关于电力起爆的说法，正确的是（ ）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","用于同一爆破网路内的电雷管，电阻值应相同",true,{"key":16,"text":17,"correct":18},"B","供给每个电雷管的实际电流应小于准爆电流",false,{"key":20,"text":21,"correct":14},"C","装炮前工作面一切电源应切除，照明至少设于距工作面30m以外",{"key":23,"text":24,"correct":18},"D","雷雨天应采用电爆网路",{"key":26,"text":27,"correct":14},"E","网路中的支线、区域线和母线彼此连接之前各自的两端应短路、绝缘","ACE","2020版教材P143 \u002F 2019版教材P145 电力起爆，应遵守的规定。（1）用于同一爆破网路内的电雷管，电阻值应相同。康铜桥丝雷管的电阻极差不得超过0.25Ω，镍铬桥丝雷管的电阻极差不得超过0.5Ω。（2）网路中的支线、区域线和母线彼此连接之前各自的两端应短路、绝缘。（3）装炮前工作面一切电源应切除，照明至少设于距工作面30m以外，只有确认炮区无漏电、感应电后，才可装炮。（4）雷雨天严禁采用电爆网路（5）供给每个电雷管的实际电流应大于准爆电流，具体要求是：①直流电源:一艇爆破不小于2.5 A;对于洞室爆破或大规模爆破不小于3A。②交流电源：一般爆破不小于3 A;对于洞室爆破或大规模爆破不小于4A。（6）网路中全部导线应绝缘。有水时导线应架空。各接头应用绝缘胶布包好，两条线的搭接口禁止重叠，至少应错开0.1m。（7）测量电阻只许使用经过检查的专用爆破测试仪表或线路电桥。严禁使用其他电气仪表进行量测。（8）通电后若发生拒爆,应立即切断母线电源，将母线两端拧在一起,锁上电源开关箱进行检查。进行检查的时间：对于即发电雷管，至少在l0min以后；对于延发电雷管，至少在15min以后。",{"id":6,"name":31,"category":32,"favorite":33},"一建水利水电工程实务","建筑工程",0]