[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-802-41":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":301},{"id":5,"name":6,"category":7,"favorite":8},802,"一建市政公用工程实务","建筑工程",0,41,50,2019,[13,38,53,68,83,98,112,127,141,155,169,184,199,214,229,243,258,272,287],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},1149973,2,"多选题","已批准占用或挖掘城市道路的工程项目，发生()情况应提前办理变更审批手续。",[19,23,27,30,33],{"key":20,"text":21,"correct":22},"A","调换作业队",false,{"key":24,"text":25,"correct":26},"B","需要移动位置",true,{"key":28,"text":29,"correct":26},"C","扩大面积",{"key":31,"text":32,"correct":22},"D","增加施工机械",{"key":34,"text":35,"correct":26},"E","延长时间","BCE","",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":52,"analysis":37},1149974,"对未中断交通的施工作业道路，应当由公安机关交通管理部门负责加强（）。",[42,44,46,48,50],{"key":20,"text":43,"correct":22},"办理审批手续",{"key":24,"text":45,"correct":26},"交通安全监督检查",{"key":28,"text":47,"correct":22},"签发相关文件",{"key":31,"text":49,"correct":26},"维护道路交通秩序",{"key":34,"text":51,"correct":22},"清除道路障碍","BD",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":67,"analysis":37},1149975,"有关道路施工安全管理说法正确的是()。",[57,59,61,63,65],{"key":20,"text":58,"correct":26},"施工中必须建立安全技术交底制度",{"key":24,"text":60,"correct":26},"对作业人员进行相关的安全技术教育与培训",{"key":28,"text":62,"correct":26},"施工技术人员必须向作业人员进行详尽的安全技术交底并形成文件",{"key":31,"text":64,"correct":22},"摊铺等专业分包工程，安全技术交底由分包单位负责",{"key":34,"text":66,"correct":22},"道路摊铺专业性较强，由专业队伍负责作业安全","ABC",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":82,"analysis":37},1149976,"施工过程中，必须对主梁各个施工阶段的( )等进行检测，并应及时将有关数据反馈给设计单位。",[72,74,76,78,80],{"key":20,"text":73,"correct":26},"拉索索力",{"key":24,"text":75,"correct":22},"主塔线型",{"key":28,"text":77,"correct":26},"主梁标高",{"key":31,"text":79,"correct":26},"塔梁内力",{"key":34,"text":81,"correct":26},"塔索位移量","ACDE",{"id":84,"libraryId":5,"type":15,"typeLabel":16,"stem":85,"options":86,"answer":97,"analysis":37},1149977,"下列有关索夹安装控制，说法正确是（ ）。",[87,89,91,93,95],{"key":20,"text":88,"correct":26},"安装前必须测定主缆的空缆线形，设计单位确认索夹位置",{"key":24,"text":90,"correct":26},"在环境温度稳定时对索夹进行放样、定位",{"key":28,"text":92,"correct":26},"清除索夹位置处主缆表面的油污及灰尘并应涂防锈漆",{"key":31,"text":94,"correct":22},"当索夹在主缆上精确定位后，应立即紧固索夹螺栓即完成安装",{"key":34,"text":96,"correct":26},"紧固同一索夹螺栓时，各螺栓受力应均匀，并应按三个荷载阶段（即索夹安装时、钢箱梁吊装后、桥面铺装后）对索夹螺栓进行紧固","ABCE",{"id":99,"libraryId":5,"type":15,"typeLabel":16,"stem":100,"options":101,"answer":67,"analysis":37},1149978,"喷锚暗挖隧道工程开工前，应核对地质资料，调查沿线( )等，并制定保护措施。",[102,104,106,108,110],{"key":20,"text":103,"correct":26},"地面建筑物基础",{"key":24,"text":105,"correct":26},"地下构筑物",{"key":28,"text":107,"correct":26},"地下管线",{"key":31,"text":109,"correct":22},"地下水",{"key":34,"text":111,"correct":22},"地面树木",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":126,"analysis":37},1149979,"盾构掘进应尽量连续作业，以( )。",[116,118,120,122,124],{"key":20,"text":117,"correct":26},"减少对地层的扰动",{"key":24,"text":119,"correct":26},"保证隧道质量",{"key":28,"text":121,"correct":22},"降低施工成本",{"key":31,"text":123,"correct":22},"加快施工进度",{"key":34,"text":125,"correct":26},"减小地表隆沉值","ABE",{"id":128,"libraryId":5,"type":15,"typeLabel":16,"stem":129,"options":130,"answer":97,"analysis":37},1149980,"下列表述中，( )是水池气密性试验应具备的工作条件。",[131,133,135,137,139],{"key":20,"text":132,"correct":26},"池体满水试验合格",{"key":24,"text":134,"correct":26},"所需的空气压缩机等设备已准备就绪",{"key":28,"text":136,"correct":26},"池顶盖板的封闭",{"key":31,"text":138,"correct":22},"保护层喷涂后",{"key":34,"text":140,"correct":26},"工艺测温孔的加堵封闭",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":97,"analysis":37},1149981,"关于给排水管道施工质量控制，说法正确的是( )。",[145,147,149,151,153],{"key":20,"text":146,"correct":26},"各分项工程应按照施工技术标准进行质量控制",{"key":24,"text":148,"correct":26},"每分项工程完成后，必须进行检验",{"key":28,"text":150,"correct":26},"相关各分项工程之间，必须进行交接检验",{"key":31,"text":152,"correct":22},"所有隐蔽分项工程无须进行隐蔽验收",{"key":34,"text":154,"correct":26},"未经检验或验收不合格不得进行下道分项工程",{"id":156,"libraryId":5,"type":15,"typeLabel":16,"stem":157,"options":158,"answer":67,"analysis":37},1149982,"给水排水管道沟槽回填前的规定中，( )是正确的。",[159,161,163,165,167],{"key":20,"text":160,"correct":26},"水压试验前，除接口外，管道两侧及管顶以上回填高度不应小于0.5m",{"key":24,"text":162,"correct":26},"压力管道水压试验合格后，应及时回填其余部分",{"key":28,"text":164,"correct":26},"无压管道在闭水或闭气试验合格后应及时回填",{"key":31,"text":166,"correct":22},"水压试验前，接口、管道两侧及管顶均不能回填",{"key":34,"text":168,"correct":22},"水压试验前，接口、管道两侧及管顶以上回填高度不应小于0.5m",{"id":170,"libraryId":5,"type":15,"typeLabel":16,"stem":171,"options":172,"answer":183,"analysis":37},1149983,"根据《城市供热管网工程施工及验收规范》的规定，热力管道焊接施工单位应具备的条件包括()。",[173,175,177,179,181],{"key":20,"text":174,"correct":26},"有负责焊接工艺的焊接技术人员,检查人员和检验人员",{"key":24,"text":176,"correct":26},"有符合焊接工艺要求的焊接设备且性能稳定可靠",{"key":28,"text":178,"correct":22},"焊接工人的人数必须超过100人",{"key":31,"text":180,"correct":22},"检验人员必须本科毕业",{"key":34,"text":182,"correct":22},"有进行气密性检验的试验室","AB",{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":198,"analysis":37},1149984,"以下( )是热力管道施焊单位应具有的人员。",[188,190,192,194,196],{"key":20,"text":189,"correct":26},"焊接技术人员",{"key":24,"text":191,"correct":22},"监督人员",{"key":28,"text":193,"correct":26},"检查人员",{"key":31,"text":195,"correct":22},"监理人员",{"key":34,"text":197,"correct":26},"检验人员","ACE",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":213,"analysis":37},1149985,"关于热力管道直埋保温管接头的规定，以下正确的叙述是( )。",[203,205,207,209,211],{"key":20,"text":204,"correct":26},"接头施工采取的工艺应有合格的检验报告",{"key":24,"text":206,"correct":26},"接头外观不应出现过烧、鼓包、翘边、褶皱或层间脱离等现象",{"key":28,"text":208,"correct":22},"接头焊接完毕即可进行保温和密封",{"key":31,"text":210,"correct":26},"接头处的钢管表面应干净、干燥",{"key":34,"text":212,"correct":26},"接头外护层安装完成后，必须全部进行气密性检验并应合格","ABDE",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":228,"analysis":37},1149986,"关于聚乙烯燃气管道连接的要求，以下说法正确的是( )。",[218,220,222,224,226],{"key":20,"text":219,"correct":22},"不同级别聚乙烯燃气管道连接时，不能进行电熔连接",{"key":24,"text":221,"correct":22},"不同熔体流动速率的聚乙烯原料制造的管材或管件，不能进行电熔连接",{"key":28,"text":223,"correct":26},"不同级别、不同熔体流动速率的聚乙烯原料制造的管材或管件，必须进行电熔连接",{"key":31,"text":225,"correct":22},"不同标准尺寸比（SDR值）的聚乙烯燃气管道连接时，不能采用电熔连接",{"key":34,"text":227,"correct":26},"聚乙烯燃气管道连接施工前必须进行试验","CE",{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":97,"analysis":37},1149987,"凡参加燃气管道焊接工作的焊工应该具备以下条件( )。",[233,235,237,239,241],{"key":20,"text":234,"correct":26},"承担燃气钢质管道、设备焊接的人员，必须具有锅炉压力容器、压力管道特种设备操作人员资格证（焊接）和焊工合格证书，且在证书的有效期及合格范围内从事焊接工作",{"key":24,"text":236,"correct":26},"焊接工作中断6个月以上的焊工应重新参加焊工考试",{"key":28,"text":238,"correct":26},"承担其他材质燃气管道安装的人员，必须经过培训，并经考试合格，间断安装时间超过6个月，再次上岗前应重新考试和技术评定。",{"key":31,"text":240,"correct":22},"无高血压病",{"key":34,"text":242,"correct":26},"当使用的安装设备发生变化时，应针对该设备操作要求进行专门培训",{"id":244,"libraryId":5,"type":15,"typeLabel":16,"stem":245,"options":246,"answer":257,"analysis":37},1149988,"综合管廊模板施工前，应根据（）条件进行模板及支架设计。",[247,249,251,253,255],{"key":20,"text":248,"correct":26},"结构形式",{"key":24,"text":250,"correct":26},"施工工艺",{"key":28,"text":252,"correct":26},"设备",{"key":31,"text":254,"correct":26},"材料供应",{"key":34,"text":256,"correct":22},"政府管理部门要求","ABCD",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":257,"analysis":37},1149989,"基坑施工过程中，必须立即进行危险报警的情况包括()。",[262,264,266,268,270],{"key":20,"text":263,"correct":26},"监测数据达到监测报警值的累计值",{"key":24,"text":265,"correct":26},"基坑出现流沙或管涌",{"key":28,"text":267,"correct":26},"支护结构的支撑出现压屈",{"key":31,"text":269,"correct":26},"周边管线由于变形而泄漏",{"key":34,"text":271,"correct":22},"基坑支护结构由于开挖变形增大",{"id":273,"libraryId":5,"type":15,"typeLabel":16,"stem":274,"options":275,"answer":286,"analysis":37},1149990,"当出现下列（）情况之一时，应加强监测，提高监测频率。",[276,278,280,282,284],{"key":20,"text":277,"correct":26},"监测数据达到报警值",{"key":24,"text":279,"correct":22},"监测数据变化速率减缓",{"key":28,"text":281,"correct":22},"基坑边堆放物料",{"key":31,"text":283,"correct":26},"存在勘察未发现的不良地质",{"key":34,"text":285,"correct":26},"支护结构出现开裂","ADE",{"id":288,"libraryId":5,"type":15,"typeLabel":16,"stem":289,"options":290,"answer":198,"analysis":37},1149991,"工程测量作业所使用的仪器和相关设备，应做到及时检查校正，加强（）。",[291,293,295,297,299],{"key":20,"text":292,"correct":26},"维护",{"key":24,"text":294,"correct":22},"检查",{"key":28,"text":296,"correct":26},"养护",{"key":31,"text":298,"correct":22},"使用管理",{"key":34,"text":300,"correct":26},"定期检修",[302,306,309,312,315,318],{"id":303,"name":304,"category":7,"favorite":305},1,"领导干部任职前廉政法规知识测试题",92,{"id":307,"name":308,"category":7,"favorite":303},595,"建筑结构与设备",{"id":310,"name":311,"category":7,"favorite":303},715,"招标采购专业知识与法律法规",{"id":313,"name":314,"category":7,"favorite":303},848,"市政方向-通用基础",{"id":316,"name":317,"category":7,"favorite":8},534,"BIM工程师",{"id":319,"name":317,"category":7,"favorite":8},535]