[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-802-17":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":603},{"id":5,"name":6,"category":7,"favorite":8},802,"一建市政公用工程实务","建筑工程",0,17,50,2019,[13,34,46,58,70,82,94,106,118,130,142,154,165,177,189,201,213,225,237,248,260,272,284,294,306,318,330,342,354,364,372,384,396,408,418,427,438,450,462,473,485,497,509,521,533,545,557,568,580,591],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},1148752,1,"单选题","供热管道进行严密性试验时，试验压力为设计压力的1.25倍，且不小于（ ）MPa。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","1",false,{"key":24,"text":25,"correct":26},"B","0.6",true,{"key":28,"text":29,"correct":22},"C","0.5",{"key":31,"text":32,"correct":22},"D","0.2","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},1148753,"热力管网试运行的时间为：应在设计参数下连续热运行（ ）h。",[38,40,42,44],{"key":20,"text":39,"correct":22},"24",{"key":24,"text":41,"correct":22},"36",{"key":28,"text":43,"correct":22},"48",{"key":31,"text":45,"correct":26},"72",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},1148754,"热力网按敷设方式最常见的为：管沟敷设、（ ）敷设及直埋敷设。",[50,52,54,56],{"key":20,"text":51,"correct":22},"高支架",{"key":24,"text":53,"correct":22},"浅埋暗挖",{"key":28,"text":55,"correct":22},"盾构",{"key":31,"text":57,"correct":26},"架空",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},1148755,"按敷设方式分类，热力管道直接埋设在地下，无管沟的敷设叫做（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":26},"直埋敷设",{"key":24,"text":65,"correct":22},"地沟敷设",{"key":28,"text":67,"correct":22},"不通行管沟敷设",{"key":31,"text":69,"correct":22},"顶管敷设",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},1148756,"按热力管道系统形式来分，直接消耗一次热媒，中间设备少，但一次补充量大的是（ ）系统。",[74,76,78,80],{"key":20,"text":75,"correct":22},"闭式",{"key":24,"text":77,"correct":26},"开式",{"key":28,"text":79,"correct":22},"蒸汽",{"key":31,"text":81,"correct":22},"凝结水",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":20,"analysis":33},1148757,"沟槽土方开挖到基底后，地基应由施工、监理、建设、勘察和设计等单位共同验收。对松软地基、坑洞等不符合要求的地基，应由（ ）提出处理意见。",[86,88,90,92],{"key":20,"text":87,"correct":26},"设计单位或勘察单位",{"key":24,"text":89,"correct":22},"监理单位",{"key":28,"text":91,"correct":22},"施工单位技术负责人",{"key":31,"text":93,"correct":22},"建设单位技术负责人",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":31,"analysis":33},1148758,"下列关于管道固定支架说法错误的是（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":22},"固定支架必须严格安装在设计位置，位置应正确",{"key":24,"text":101,"correct":22},"支架处管道不得有环焊缝",{"key":28,"text":103,"correct":22},"固定支架的固定角板应与管道焊接",{"key":31,"text":105,"correct":26},"支架应与管道连接牢固，以限制管道伸缩",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":20,"analysis":33},1148759,"弹簧支、吊架的安装高度应按设计要求进行调整。弹簧的临时固定件，应待管道安装、试压、（ ）完毕后拆除。",[110,112,114,116],{"key":20,"text":111,"correct":26},"管道保温",{"key":24,"text":113,"correct":22},"管道焊接",{"key":28,"text":115,"correct":22},"管道试压",{"key":31,"text":117,"correct":22},"管道冲洗",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},1148760,"热网上的补偿器主要是由于（ ）原因而设置的。",[122,124,126,128],{"key":20,"text":123,"correct":22},"钢管所受压力",{"key":24,"text":125,"correct":26},"钢管所受温度",{"key":28,"text":127,"correct":22},"钢管太大",{"key":31,"text":129,"correct":22},"钢管强度",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":20,"analysis":33},1148761,"热力管网中需要添加补偿器的原因不包括（ ）。",[134,136,138,140],{"key":20,"text":135,"correct":26},"便于设备及管件的拆装维护",{"key":24,"text":137,"correct":22},"为了释放温度变形",{"key":28,"text":139,"correct":22},"消除温度应力",{"key":31,"text":141,"correct":22},"确保管网运行安全",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":28,"analysis":33},1148762,"用于一般汽、水管路作全启或全闭操作的阀门称为（ ）。",[146,148,150,152],{"key":20,"text":147,"correct":22},"截止阀",{"key":24,"text":149,"correct":22},"柱塞阀",{"key":28,"text":151,"correct":26},"闸阀",{"key":31,"text":153,"correct":22},"止回阀",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":20,"analysis":33},1148763,"主要用于蒸汽管路，可根据需要降低气体压力的是（ ）。",[158,160,161,163],{"key":20,"text":159,"correct":26},"减压阀",{"key":24,"text":151,"correct":22},{"key":28,"text":162,"correct":22},"安全阀",{"key":31,"text":164,"correct":22},"球阀",{"id":166,"libraryId":5,"type":15,"typeLabel":16,"stem":167,"options":168,"answer":20,"analysis":33},1148764,"供热管道强度试验所用压力表，其精度等级不得低于（ ）级。",[169,171,173,175],{"key":20,"text":170,"correct":26},"1.0",{"key":24,"text":172,"correct":22},"1.5",{"key":28,"text":174,"correct":22},"2.0",{"key":31,"text":176,"correct":22},"2.5",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":31,"analysis":33},1148765,"某供热管网设计压力为0.4MPa，其严密性试验压力（ ）。",[181,183,185,187],{"key":20,"text":182,"correct":22},"0.42",{"key":24,"text":184,"correct":22},"0.46",{"key":28,"text":186,"correct":22},"0.50",{"key":31,"text":188,"correct":26},"0.60",{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":24,"analysis":33},1148766,"供热站所所有系统应进行严密性试验，试验压力为1.25倍设计压力，且不得低于（ ），稳压在1h内，详细检查管道、焊缝、管路附件及设备等无渗漏，压力降不大于0.05MPa为合格。",[193,195,197,199],{"key":20,"text":194,"correct":22},"0.5MPa",{"key":24,"text":196,"correct":26},"0.6MPa",{"key":28,"text":198,"correct":22},"0.4MPa",{"key":31,"text":200,"correct":22},"0.8MPa",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":20,"analysis":33},1148767,"输气压力为1.2MPa的燃气管道为（ ）燃气管道。",[205,207,209,211],{"key":20,"text":206,"correct":26},"次高压A",{"key":24,"text":208,"correct":22},"次高压B",{"key":28,"text":210,"correct":22},"高压A",{"key":31,"text":212,"correct":22},"高压B",{"id":214,"libraryId":5,"type":15,"typeLabel":16,"stem":215,"options":216,"answer":20,"analysis":33},1148768,"高压燃气管道应采用（ ）。",[217,219,221,223],{"key":20,"text":218,"correct":26},"钢管",{"key":24,"text":220,"correct":22},"机械接口铸铁管",{"key":28,"text":222,"correct":22},"PE管",{"key":31,"text":224,"correct":22},"承插接口铸铁管",{"id":226,"libraryId":5,"type":15,"typeLabel":16,"stem":227,"options":228,"answer":20,"analysis":33},1148769,"下面关于燃气管道安装的要求叙述中不正确的是（ ）。",[229,231,233,235],{"key":20,"text":230,"correct":26},"高压和中压A燃气管道，应采用机械接口铸铁管",{"key":24,"text":232,"correct":22},"中压B燃气管道宜采用钢管或机械接口铸铁管",{"key":28,"text":234,"correct":22},"低压地下燃气管道采用聚乙烯管材时，应符合有关标准的规定",{"key":31,"text":236,"correct":22},"地下燃气管道不得从建筑物和大型构筑物的下面穿越",{"id":238,"libraryId":5,"type":15,"typeLabel":16,"stem":239,"options":240,"answer":24,"analysis":33},1148770,"我国城市燃气管道按压力来分，低压燃气输气压力P＜（ ）MPa。",[241,243,245,247],{"key":20,"text":242,"correct":22},"0.001",{"key":24,"text":244,"correct":26},"0.01",{"key":28,"text":246,"correct":22},"0.1",{"key":31,"text":170,"correct":22},{"id":249,"libraryId":5,"type":15,"typeLabel":16,"stem":250,"options":251,"answer":20,"analysis":33},1148771,"利用道路桥梁跨越河流的燃气管道，其管道的输送压力（ ）。",[252,254,256,258],{"key":20,"text":253,"correct":26},"不应大于0.4MPa",{"key":24,"text":255,"correct":22},"不应小于0.4MPa",{"key":28,"text":257,"correct":22},"不应大于0.5MPa",{"key":31,"text":259,"correct":22},"不应小于0.5MPa",{"id":261,"libraryId":5,"type":15,"typeLabel":16,"stem":262,"options":263,"answer":31,"analysis":33},1148772,"燃气管道通过河流时，不可采用下面哪种方式（ ）。",[264,266,268,270],{"key":20,"text":265,"correct":22},"穿越河底",{"key":24,"text":267,"correct":22},"管桥跨越",{"key":28,"text":269,"correct":22},"利用道路桥梁跨越",{"key":31,"text":271,"correct":26},"穿越河底时，敷设在PVC套管内",{"id":273,"libraryId":5,"type":15,"typeLabel":16,"stem":274,"options":275,"answer":20,"analysis":33},1148773,"燃气管道及其附件组装完成并在试压前，应进行气体吹扫，每次吹扫管道长度不宜超过（ ）m。",[276,278,280,282],{"key":20,"text":277,"correct":26},"500",{"key":24,"text":279,"correct":22},"600",{"key":28,"text":281,"correct":22},"800",{"key":31,"text":283,"correct":22},"1000",{"id":285,"libraryId":5,"type":15,"typeLabel":16,"stem":286,"options":287,"answer":20,"analysis":33},1148774,"高压和中压A燃气管道应采用下面哪种管材（ ）。",[288,289,290,292],{"key":20,"text":218,"correct":26},{"key":24,"text":220,"correct":22},{"key":28,"text":291,"correct":22},"聚乙烯管材",{"key":31,"text":293,"correct":22},"聚氯乙烯管材",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":28,"analysis":33},1148775,"通过用户管道引入口的总阀门将燃气引向室内，并分配到每个燃气用具的是下面哪种管道（ ）。",[298,300,302,304],{"key":20,"text":299,"correct":22},"分配管道",{"key":24,"text":301,"correct":22},"用户引入管道",{"key":28,"text":303,"correct":26},"室内燃气管道",{"key":31,"text":305,"correct":22},"车间燃气管道",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":20,"analysis":33},1148776,"干管及支管的末端连接城市或大型工业企业，作为供应区的气源点的是（ ）。",[310,312,314,316],{"key":20,"text":311,"correct":26},"长距离输气管道",{"key":24,"text":313,"correct":22},"城市燃气管道",{"key":28,"text":315,"correct":22},"工业企业燃气管道",{"key":31,"text":317,"correct":22},"炉前燃气管道",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":20,"analysis":33},1148777,"按燃气的（ ）不同可以将燃气管道划分为长距离输气管道、城市燃气管道和工业企业燃气管道。",[322,324,326,328],{"key":20,"text":323,"correct":26},"用途",{"key":24,"text":325,"correct":22},"压力",{"key":28,"text":327,"correct":22},"管径",{"key":31,"text":329,"correct":22},"敷设方式",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":20,"analysis":33},1148778,"我国城市燃气管道按输气压力来分，高压A燃气管道的压力为2.5MPa＜P≤（ ）MPa。",[334,336,338,340],{"key":20,"text":335,"correct":26},"4.0",{"key":24,"text":337,"correct":22},"3.5",{"key":28,"text":339,"correct":22},"5.0",{"key":31,"text":341,"correct":22},"6.0",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":31,"analysis":33},1148779,"次高压A燃气管道的输气压力值为下面的哪一个（ ）。",[346,348,350,352],{"key":20,"text":347,"correct":22},"0.1MPa＜P≤0.2MPa",{"key":24,"text":349,"correct":22},"0.2MPa＜P≤0.4MPa",{"key":28,"text":351,"correct":22},"0.4MPa＜P＜0.8MPa",{"key":31,"text":353,"correct":26},"0.8MPa＜P≤1.6MPa",{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":28,"analysis":33},1148780,"我国城市燃气管道按输气压力来分，中压A燃气管道的压力在0.2MPa＜P≤（ ）MPa范围内。",[358,359,361,363],{"key":20,"text":29,"correct":22},{"key":24,"text":360,"correct":22},"0.3",{"key":28,"text":362,"correct":26},"0.4",{"key":31,"text":25,"correct":22},{"id":365,"libraryId":5,"type":15,"typeLabel":16,"stem":366,"options":367,"answer":20,"analysis":33},1148781,"西气东输管道属于（ ）燃气管道。",[368,369,370,371],{"key":20,"text":210,"correct":26},{"key":24,"text":206,"correct":22},{"key":28,"text":212,"correct":22},{"key":31,"text":208,"correct":22},{"id":373,"libraryId":5,"type":15,"typeLabel":16,"stem":374,"options":375,"answer":31,"analysis":33},1148782,"一般来说下面哪种燃气管道构成大城市输配管网系统的外环网（ ）。",[376,378,380,382],{"key":20,"text":377,"correct":22},"中压A燃气管道",{"key":24,"text":379,"correct":22},"中压B燃气管道",{"key":28,"text":381,"correct":22},"次高压B燃气管道",{"key":31,"text":383,"correct":26},"高压B燃气管道",{"id":385,"libraryId":5,"type":15,"typeLabel":16,"stem":386,"options":387,"answer":28,"analysis":33},1148783,"当地下燃气管道穿过排水管、热力管沟、联合地沟等各种用途沟槽时，燃气管道外部必须（ ）。",[388,390,392,394],{"key":20,"text":389,"correct":22},"提高防腐等级",{"key":24,"text":391,"correct":22},"加大管径",{"key":28,"text":393,"correct":26},"做套管",{"key":31,"text":395,"correct":22},"加厚管壁",{"id":397,"libraryId":5,"type":15,"typeLabel":16,"stem":398,"options":399,"answer":20,"analysis":33},1148784,"地下燃气管道与构筑物的水平间距无法满足安全距离时，应（ ）。",[400,402,404,406],{"key":20,"text":401,"correct":26},"将管道设于管道沟或刚性套管内",{"key":24,"text":403,"correct":22},"采用管桥",{"key":28,"text":405,"correct":22},"埋高绝缘装置",{"key":31,"text":407,"correct":22},"采用加厚的无缝钢管",{"id":409,"libraryId":5,"type":15,"typeLabel":16,"stem":410,"options":411,"answer":20,"analysis":33},1148785,"地下燃气管道保护设施两端应伸出障碍物且与被跨越的障碍物间的距离不应小于（ ）m。",[412,413,415,417],{"key":20,"text":29,"correct":26},{"key":24,"text":414,"correct":22},"0.7",{"key":28,"text":416,"correct":22},"0.8",{"key":31,"text":21,"correct":22},{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":20,"analysis":33},1148786,"燃气管道穿越电车轨道和城镇主要干道时宜（ ）。",[422,424,425,426],{"key":20,"text":423,"correct":26},"敷设在套管或地沟内",{"key":24,"text":403,"correct":22},{"key":28,"text":405,"correct":22},{"key":31,"text":407,"correct":22},{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":20,"analysis":33},1148787,"燃气管道穿越河底时，燃气管道宜采用（ ）。",[431,432,434,436],{"key":20,"text":218,"correct":26},{"key":24,"text":433,"correct":22},"铸铁管",{"key":28,"text":435,"correct":22},"塑料管",{"key":31,"text":437,"correct":22},"钢筋混凝土管",{"id":439,"libraryId":5,"type":15,"typeLabel":16,"stem":440,"options":441,"answer":24,"analysis":33},1148788,"燃气管道随桥梁敷设，过河架空的燃气管道向下弯曲时，宜采用（ ）弯头。",[442,444,446,448],{"key":20,"text":443,"correct":22},"30°",{"key":24,"text":445,"correct":26},"45°",{"key":28,"text":447,"correct":22},"60°",{"key":31,"text":449,"correct":22},"90°",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":20,"analysis":33},1148789,"为了排除燃气管道中的冷凝水和石油伴生气管道中的轻质油，管道敷设时应有一定坡度，以便在低处设（ ），将汇集的水或油排出。",[454,456,458,460],{"key":20,"text":455,"correct":26},"凝水缸",{"key":24,"text":457,"correct":22},"过滤器",{"key":28,"text":459,"correct":22},"调压器",{"key":31,"text":461,"correct":22},"引射器",{"id":463,"libraryId":5,"type":15,"typeLabel":16,"stem":464,"options":465,"answer":28,"analysis":33},1148790,"下列燃气和热水管网附属设备中，属于燃气管网独有的是（ ）。",[466,468,470,471],{"key":20,"text":467,"correct":22},"阀门",{"key":24,"text":469,"correct":22},"补偿装置",{"key":28,"text":455,"correct":26},{"key":31,"text":472,"correct":22},"排气装置",{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":28,"analysis":33},1148791,"为了保证燃气管网的安全与操作方便，地下燃气管道的阀门一般都设置在（ ）。",[477,479,481,483],{"key":20,"text":478,"correct":22},"地上",{"key":24,"text":480,"correct":22},"阀门盖",{"key":28,"text":482,"correct":26},"阀门井口",{"key":31,"text":484,"correct":22},"保温层",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":24,"analysis":33},1148792,"关于燃气管道强度试验的说法，错误的是（ ）。",[489,491,493,495],{"key":20,"text":490,"correct":22},"压力计及温度记录仪表均不应少于2块",{"key":24,"text":492,"correct":26},"埋地管道回填土宜回填至管上方0.3m以上，并留出焊接口",{"key":28,"text":494,"correct":22},"试验用压力计的量程应为试验压力的1.5～2倍",{"key":31,"text":496,"correct":22},"管道焊接检验、清扫合格",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":28,"analysis":33},1148793,"燃气管道的气密性试验持续时间一般不少于（ ），实际压力降不超过允许值为合格。",[501,503,505,507],{"key":20,"text":502,"correct":22},"4h",{"key":24,"text":504,"correct":22},"12h",{"key":28,"text":506,"correct":26},"24h",{"key":31,"text":508,"correct":22},"48h",{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":20,"analysis":33},1148794,"燃气管道设计压力大于5kPa，严密性试验压力为设计压力的（ ）倍，且不得小于0.1MPa，稳压时间为（ ）h，修正压降不超过（ ）Pa，即为合格。",[513,515,517,519],{"key":20,"text":514,"correct":26},"1.15，24，133",{"key":24,"text":516,"correct":22},"1.25，24，133",{"key":28,"text":518,"correct":22},"1.15，2，125",{"key":31,"text":520,"correct":22},"1.25，2，125",{"id":522,"libraryId":5,"type":15,"typeLabel":16,"stem":523,"options":524,"answer":28,"analysis":33},1148795,"关于燃气管道严密性试验应满足的条件，表述错误的是（ ）。",[525,527,529,531],{"key":20,"text":526,"correct":22},"强度试验合格后，即可进行严密性试验",{"key":24,"text":528,"correct":22},"设计压力小于5kPa时，试验压力应为20kPa",{"key":28,"text":530,"correct":26},"设计压力大于5kPa时，试验压力应为20kPa",{"key":31,"text":532,"correct":22},"设计压力大于或等于5kPa时，试验压力应为设计压力的1.15倍，且不得小于0.1MPa",{"id":534,"libraryId":5,"type":15,"typeLabel":16,"stem":535,"options":536,"answer":20,"analysis":33},1148796,"燃气管道在安装过程中需要进行严密性试验，试验时所用的介质应是（ ）。",[537,539,541,543],{"key":20,"text":538,"correct":26},"空气",{"key":24,"text":540,"correct":22},"肥皂水",{"key":28,"text":542,"correct":22},"水",{"key":31,"text":544,"correct":22},"沙",{"id":546,"libraryId":5,"type":15,"typeLabel":16,"stem":547,"options":548,"answer":20,"analysis":33},1148797,"燃气管道气密性试验，压力应根据管道设计输气压力而定，当设计输气压力P＜5kPa时，试验压力为（ ）。",[549,551,553,555],{"key":20,"text":550,"correct":26},"20kPa",{"key":24,"text":552,"correct":22},"10kPa",{"key":28,"text":554,"correct":22},"15kPa",{"key":31,"text":556,"correct":22},"25kPa",{"id":558,"libraryId":5,"type":15,"typeLabel":16,"stem":559,"options":560,"answer":28,"analysis":33},1148798,"燃气管道做强度试验时，当压力达到规定值后，应稳压（ ）。",[561,563,565,567],{"key":20,"text":562,"correct":22},"3h",{"key":24,"text":564,"correct":22},"2h",{"key":28,"text":566,"correct":26},"1h",{"key":31,"text":502,"correct":22},{"id":569,"libraryId":5,"type":15,"typeLabel":16,"stem":570,"options":571,"answer":24,"analysis":33},1148799,"埋地燃气管道，必须回填土至管顶（ ）以上后才可进行气密性试验。",[572,574,576,578],{"key":20,"text":573,"correct":22},"0.2m",{"key":24,"text":575,"correct":26},"0.5m",{"key":28,"text":577,"correct":22},"1.0m",{"key":31,"text":579,"correct":22},"0.8m",{"id":581,"libraryId":5,"type":15,"typeLabel":16,"stem":582,"options":583,"answer":28,"analysis":33},1148800,"当室外燃气钢管的设计输气压力为0.1MPa时，其强度试验压力应为（ ）。",[584,586,588,589],{"key":20,"text":585,"correct":22},"0.1MPa",{"key":24,"text":587,"correct":22},"0.15MPa",{"key":28,"text":198,"correct":26},{"key":31,"text":590,"correct":22},"0.3MPa",{"id":592,"libraryId":5,"type":15,"typeLabel":16,"stem":593,"options":594,"answer":24,"analysis":33},1148801,"综合管廊是建于地下用于容纳（）类及以上城市工程管线的构筑物及附属设施。",[595,597,599,601],{"key":20,"text":596,"correct":22},"一",{"key":24,"text":598,"correct":26},"两",{"key":28,"text":600,"correct":22},"三",{"key":31,"text":602,"correct":22},"四",[604,607,610,613,616,619],{"id":15,"name":605,"category":7,"favorite":606},"领导干部任职前廉政法规知识测试题",92,{"id":608,"name":609,"category":7,"favorite":15},595,"建筑结构与设备",{"id":611,"name":612,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":614,"name":615,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":617,"name":618,"category":7,"favorite":8},534,"BIM工程师",{"id":620,"name":618,"category":7,"favorite":8},535]