[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1149888":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1149888,802,2,"多选题","防水施工质量控制中，下列表述正确的有（ ）。",[11,15,18,22,25],{"key":12,"text":13,"correct":14},"A","应在初期支护完全稳定，且衬砌检查合格后进行",false,{"key":16,"text":17,"correct":14},"B","清理混凝土表面，剔除尖、突部位并用混凝土压实、找平",{"key":19,"text":20,"correct":21},"C","衬垫材料应直顺，用垫圈固定，钉牢在基面上",true,{"key":23,"text":24,"correct":21},"D","固定衬垫的垫圈，应与防水卷材同材质，并焊接牢固",{"key":26,"text":27,"correct":21},"E","采用专用热合机焊接，焊缝应均匀连续","CDE","2020教材P371 \u002F 2019教材P372 三、防水、二次衬砌施工质量控制：（一）防水层施工：1、应在初期支护基本稳定且衬砌检查合格后进行；2、清理混凝土表面，剔除尖、突部位并用水泥砂浆压实、找平，防水层铺设基面凹凸高差不应大于50mm，基面阴阳角应处理成圆角或钝角，圆弧半径不宜小于100mm；3、衬垫材料应直顺，用垫圈固定，钉牢在基面上；固定衬垫的垫圈，应与防水卷材同材质，并焊接牢固；衬垫固定时宜交错布置，间距应符合设计要求；固定钉距防水卷材外边缘的距离不应于于0.5m；衬垫材料搭接宽度不宜小于500mm。4、防水卷材固定在初期初砌面上，采用软塑料类防水卷材时，宜采用热焊固定在垫圈上。5、采用专用热合机焊接，焊缝应均匀连续；双焊缝搭接的焊缝宽不应小于10mm；焊缝不得有漏焊、假焊、焊焦、焊穿等现象；焊缝应经充气试验合格；气压0.15MPa，经过3min其下降值不大于20%。",{"id":6,"name":31,"category":32,"favorite":33},"一建市政公用工程实务","建筑工程",0]