[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1149725":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1149725,802,2,"多选题","燃气管道穿越河底时，应附合下列要求：（ ）",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","在埋设燃气管道位置的河流两岸上,下游应设标志",true,{"key":16,"text":17,"correct":18},"B","管道对接安装引起的误差不得大于5°",false,{"key":20,"text":21,"correct":14},"C","宜采用钢管",{"key":23,"text":24,"correct":14},"D","不通航时，燃气管道至河底最小覆土厚度不应小于0.5m",{"key":26,"text":27,"correct":14},"E","通航时，燃气管道至河底最小覆土厚度不应小于1.0m，还应考虑疏浚和投锚深度","ACDE","2020教材P234 \u002F 2019教材P235 燃气管道穿越河底时，应符合下列要求：（1）燃气管道宜采用钢管；（2）燃气管道至规划河底的覆土厚度，对不通航河流不应小于0.5m；对通航的河流不应小于1.0m，还应考虑疏浚和投锚深度；（3）稳管措施应根据计算确定；（4）在埋设燃气管道位置的河流两岸上、下游应设立标志。",{"id":6,"name":31,"category":32,"favorite":33},"一建市政公用工程实务","建筑工程",0]