[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1149527":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1149527,802,2,"多选题","关于管涵施工技术要点的说法，错误的有()。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","管涵通常采用工厂预制钢筋混凝土管的成品管节",false,{"key":16,"text":17,"correct":18},"B","当管涵设计基础为混凝土或砌体基础时，基础上面可不设混凝土管座",true,{"key":20,"text":21,"correct":18},"C","当管涵基础为天然地基时，应将管底土层夯压密实，形成平基管座",{"key":23,"text":24,"correct":18},"D","管涵的沉降缝应设在两端",{"key":26,"text":27,"correct":14},"E","管涵出入端墙、翼墙应符合《给水排水构筑物工程施工及验收规范》GB50141-2008有关规定","BCD","2020教材P91 \u002F 2019教材P92 一、管涵施工技术要点(1)管涵是采用工厂预制钢筋混凝土管成品管节做成的涵洞的统称。管节断面形式分为圆形、椭圆形、卵形、矩形等。(2）当管涵设计为混凝土或砌体基础时，基础上面应设混凝土管座，其顶部弧形面应与管身紧密贴合，使管节均匀受力。(3)当管涵为无混凝土（或砌体）基础、管体直接设置在天然地基上时，应按照设计要求将管底土层夯压密实，并做成与管身弧度密贴的弧形管座，安装管节时应注意保持完整。管底层承载力不符合设计要求时，应按规范要求进行处理、加固。(4)管涵的沉降缝应设在管节接缝处。(5)管涵进出水口的沟床应整理直顺，与上下游导流排水系统连接顺畅、稳固。(6)采用预制管埋设的管涵施工，应符合现行国家标准《给水排水管道工程施工及验收规范》G B 50268—2008有关规定。(7)管涵出入端墙、翼墙应符合现行国家标准《给水排水构筑物工程施工及验收规范》GB 50141—2008第5.5节规定。",{"id":6,"name":31,"category":32,"favorite":33},"一建市政公用工程实务","建筑工程",0]