[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1149209":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1149209,802,2,"多选题","（2010 年真题）关于供热管道补偿器安装的说法，正确的有（ ）",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","管道补偿器的两端，应各设一个固定支座",false,{"key":16,"text":17,"correct":18},"B","靠近补偿器的两端，应至少各设有一个导向支座",true,{"key":20,"text":21,"correct":14},"C","应对补偿器进行预拉伸",{"key":23,"text":24,"correct":18},"D","填料式补偿器垂直安装时，有插管的一段应置于上部",{"key":26,"text":27,"correct":18},"E","管道安装、试压、保温完毕后，应将补偿器临时固定装置的坚固件松开","BDE","有补偿器装置的管段，在补偿器安装前，管道和固定支架之间不得进行固定，故A 错误。在靠近补偿器的两端，至少应各设一个导向支架，保证运行时自由伸缩，不偏离中心，故B 正确。当安装的环境温度不得低于补偿零点（设计的最高温度与最低温度差值的1\u002F2）时，应对补偿器进行预拉伸，拉伸的具体数值应符合设计文件的规定，故C 错误。补偿器的临时固定装置在管道安装、试压、保温完毕后，应将紧周件松开，保证在使用中=可以自由伸缩，故E 正确。",{"id":6,"name":31,"category":32,"favorite":33},"一建市政公用工程实务","建筑工程",0]