[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1149200":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1149200,802,2,"多选题","（2020年真题）关于直径50m的无粘结预应力混凝土沉淀池施工技术的说法，正确的有（）。",[11,15,18,21,25],{"key":12,"text":13,"correct":14},"A","无粘结预应力筋不允许有接头",true,{"key":16,"text":17,"correct":14},"B","封锚外露预应力筋保护层厚度不小于50mm",{"key":19,"text":20,"correct":14},"C","封锚混凝土强度等级不得低于C40",{"key":22,"text":23,"correct":24},"D","安装时，每段预应力筋计算长度为两端张拉工作长度和锚具长度",false,{"key":26,"text":27,"correct":24},"E","封锚前无粘结预应力筋应切断，外露长度不大于50mm","ABC","P188-191 选项A正确，无粘结预应力筋中严禁有接头。 选项B正确，外露预应力筋的保护层厚度不应小于50mm。 选项C正确，封锚混凝土强度等级不得低于相应结构混凝土强度等级，且不得低于C40。 选项D错误，每段无粘结预应力筋的计算长度应加入一个锚固肋宽度及两端张拉工作长度和锚具长度。 选项E错误，凸出式锚固端锚具的保护层厚度不应小于50mm。",{"id":6,"name":31,"category":32,"favorite":33},"一建市政公用工程实务","建筑工程",0]