[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1148734":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},1148734,802,1,"单选题","下列关于热力管道安装无损检测要求说法错误的是（ ）。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","管线折点处现场焊接的焊缝，应进行100%的无损探伤检验",false,{"key":16,"text":17,"correct":14},"B","钢管与设备、管件连接处的焊缝应进行100%无损探伤检验",{"key":19,"text":20,"correct":21},"C","焊缝返修前应进行表面质量及100%的无损探伤检验",true,{"key":23,"text":24,"correct":14},"D","现场制作的各种管件，数量按100%进行，其合格标准不得低于管道无损检验标准","2020\u002F2019教材P221 （六）（4）钢管与设备、管件连接处的焊缝应进行100%无损探伤检验；管线折点处现场焊接的焊缝，应进行100%的无损探伤检验；焊缝返修后应进行表面质量及100%的无损探伤检验，其检验数量不计在规定检验数中；现场制作的各种管件，数量按100%进行，其合格标准不得低于管道无损检验标准。",{"id":6,"name":27,"category":28,"favorite":29},"一建市政公用工程实务","建筑工程",0]