[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1148533":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},1148533,802,1,"单选题","关于支架法现浇预应力混凝土连续梁施工技术，说法错误的有()。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","支架的地基承载力应符合要求",false,{"key":16,"text":17,"correct":14},"B","支架底部应有良好的排水措施，不得被水浸泡",{"key":19,"text":20,"correct":21},"C","安装支架时，应根据支架拼装间隙和地基沉降等，设置预拱度",true,{"key":23,"text":24,"correct":14},"D","各种支架和模板安装后，宜采取预压方法消除拼装间隙和地基沉降等非弹性变形","2020\u002F2019教材P79 （1)支架的地基承载力应符合要求，必要时，应采取加强处理或其他措施。（2)应有简便可行的落架拆模措施。（3)各种支架和模板安装后，宜采取预压方法消除拼装间隙和地基沉降等非弹性变形。（4)安装支架时，应根据梁体和支架的弹性、非弹性变形，设置预拱度。（5)支架底部应有良好的排水措施，不得被水浸泡。（6)浇筑混凝土时应采取防止支架不均匀下沉的措施。",{"id":6,"name":27,"category":28,"favorite":29},"一建市政公用工程实务","建筑工程",0]