[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-800-39":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":649},{"id":5,"name":6,"category":7,"favorite":8},800,"一建建筑工程实务","建筑工程",0,39,50,2362,[13,34,45,63,73,82,90,98,110,122,134,146,158,167,182,197,212,227,239,252,263,275,290,304,316,330,342,354,369,384,396,408,423,438,450,462,476,491,503,516,531,543,558,570,582,594,609,617,629,637],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},1145324,1,"单选题","关于建筑物内的厨房，其顶棚、墙面、地面所采用的装修材料的燃烧性能等级的说法，正确的是（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","顶棚、墙面、地面均应采用A级装修材料",true,{"key":24,"text":25,"correct":26},"B","顶棚应采用A级装修材料，墙面和地面应采用不低于B1级装修材料",false,{"key":28,"text":29,"correct":26},"C","顶棚和墙面应采用A级装修材料，地面采用不低于B1级装修材料",{"key":31,"text":32,"correct":26},"D","顶棚、墙面、地面均可采用经过阻燃处理的B1级装修材料","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},1145325,"建筑的空调机房，其内部所用装饰装修材料应为（ ）等级防火材料。",[38,39,41,43],{"key":20,"text":20,"correct":22},{"key":24,"text":40,"correct":26},"B1",{"key":28,"text":42,"correct":26},"B2",{"key":31,"text":44,"correct":26},"B3",{"id":46,"libraryId":5,"type":47,"typeLabel":48,"stem":49,"options":50,"answer":62,"analysis":33},1145326,2,"多选题","下列房间内部所有装修均应采用A级装修材料的有（ ）。",[51,53,55,57,59],{"key":20,"text":52,"correct":22},"消防水泵房",{"key":24,"text":54,"correct":22},"排烟机房",{"key":28,"text":56,"correct":22},"配电室",{"key":31,"text":58,"correct":26},"中央控制室",{"key":60,"text":61,"correct":22},"E","通风和空调机房","ABCE",{"id":64,"libraryId":5,"type":15,"typeLabel":16,"stem":65,"options":66,"answer":20,"analysis":33},1145327,"《建筑内部装修设计防火规范》GB50222的强制性条文规定，消防水泵房、排烟机房、固定灭火系统钢瓶间、配电室、变压器室、通风和空调机房等，其内部所有装修均应采用（ ）装修材料。",[67,69,71,72],{"key":20,"text":68,"correct":22},"A级",{"key":24,"text":70,"correct":26},"B级",{"key":28,"text":70,"correct":26},{"key":31,"text":70,"correct":26},{"id":74,"libraryId":5,"type":47,"typeLabel":48,"stem":75,"options":76,"answer":62,"analysis":33},1145328,"内部所有装修均应采用A级装修材料的有（ ）。",[77,78,79,80,81],{"key":20,"text":52,"correct":22},{"key":24,"text":54,"correct":22},{"key":28,"text":56,"correct":22},{"key":31,"text":58,"correct":26},{"key":60,"text":61,"correct":22},{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},1145329,"施涂于A级基材上，湿涂覆比小于1.5kg\u002Fm2的有机装饰涂料，可作为（ ）级装修材料使用。",[86,87,88,89],{"key":20,"text":20,"correct":26},{"key":24,"text":40,"correct":22},{"key":28,"text":42,"correct":26},{"key":31,"text":44,"correct":26},{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":20,"analysis":33},1145330,"根据《建筑内部装修设计防火规范》GB50222-2001，安装在钢龙骨上燃烧性能达到B1级的纸面石膏板，可作为（ ）级装修材料使用。",[94,95,96,97],{"key":20,"text":20,"correct":22},{"key":24,"text":40,"correct":26},{"key":28,"text":42,"correct":26},{"key":31,"text":44,"correct":26},{"id":99,"libraryId":5,"type":15,"typeLabel":16,"stem":100,"options":101,"answer":31,"analysis":33},1145331,"单位重量小于300g\u002Fm2的纸质、布质壁纸，当直接粘贴在（ ）上时，可作为B1级装修材料使用。",[102,104,106,108],{"key":20,"text":103,"correct":26},"难燃木材",{"key":24,"text":105,"correct":26},"难燃胶合板",{"key":28,"text":107,"correct":26},"玻璃棉吸声板",{"key":31,"text":109,"correct":22},"混凝土基层",{"id":111,"libraryId":5,"type":15,"typeLabel":16,"stem":112,"options":113,"answer":31,"analysis":33},1145332,"下列叙述错误的是（ ）。",[114,116,118,120],{"key":20,"text":115,"correct":26},"安装在钢龙骨上燃烧性能达到B1级的纸面石膏板、矿棉吸声板，可作为A级装修材料使用。",{"key":24,"text":117,"correct":26},"单位面积质量小于300g\u002Fm2的纸质，布质壁纸，当直接粘贴在A级基材上时，可作为B1组装修材料使用",{"key":28,"text":119,"correct":26},"施涂于A级基材上的无机装饰材料，可作为A级装修材料使用",{"key":31,"text":121,"correct":22},"施涂于A级基材上，湿涂覆比小于1.5kg\u002Fm2，且涂层干膜厚度不大于1.0mm的有机装修涂料，不可作为B级装修材料使用",{"id":123,"libraryId":5,"type":15,"typeLabel":16,"stem":124,"options":125,"answer":28,"analysis":33},1145333,"对于非人员密集、非用火、燃油、燃气等具有火灾危险性的场所，应采用（ ）的保温材料。",[126,128,130,132],{"key":20,"text":127,"correct":26},"低烟、低毒且燃烧性能不低于B2的保温材料",{"key":24,"text":129,"correct":26},"低烟且燃烧性能不低于A的保温材料",{"key":28,"text":131,"correct":22},"低烟、低毒且燃烧性能不低于B1级的保温材料",{"key":31,"text":133,"correct":26},"低毒且燃烧性能不低于A的保温材料",{"id":135,"libraryId":5,"type":15,"typeLabel":16,"stem":136,"options":137,"answer":28,"analysis":33},1145334,"保温系统采用燃烧性能为B1的保温材料作防护层时，防护层的厚度不应小于（ ）mm。",[138,140,142,144],{"key":20,"text":139,"correct":26},"5",{"key":24,"text":141,"correct":26},"8",{"key":28,"text":143,"correct":22},"10",{"key":31,"text":145,"correct":26},"12",{"id":147,"libraryId":5,"type":15,"typeLabel":16,"stem":148,"options":149,"answer":20,"analysis":33},1145335,"与基层墙体、装饰层之间无空腔的建筑外墙外保温系统，其保温材料的燃烧性能应（ ）",[150,152,154,156],{"key":20,"text":151,"correct":22},"住宅建筑建筑高度大于100m时，保温材料的燃烧性能应为A级",{"key":24,"text":153,"correct":26},"住宅建筑建筑高度大于27m时，但不大于100m时，保温材料的燃烧性能不应低于B2级",{"key":28,"text":155,"correct":26},"除住宅建筑外其他建筑，高度大于50m时，保温材料的燃烧性能不应低于B2级",{"key":31,"text":157,"correct":26},"除住宅建筑外其他建筑，建筑高度不大于10m时，保温材料的燃烧性能不应低于B3级",{"id":159,"libraryId":5,"type":15,"typeLabel":16,"stem":160,"options":161,"answer":20,"analysis":33},1145336,"建筑内、外保温系统，宜采用燃烧性能为（ ）级材料。",[162,163,164,166],{"key":20,"text":20,"correct":22},{"key":24,"text":40,"correct":26},{"key":28,"text":165,"correct":26},"B1、B2",{"key":31,"text":42,"correct":26},{"id":168,"libraryId":5,"type":47,"typeLabel":48,"stem":169,"options":170,"answer":181,"analysis":33},1145337,"根据《建筑材料及制品燃烧性能分级》，建筑材料燃烧性能分为（ ）等几个等级。",[171,173,175,177,179],{"key":20,"text":172,"correct":22},"不燃性材料",{"key":24,"text":174,"correct":26},"阻燃性材料",{"key":28,"text":176,"correct":22},"难燃性材料",{"key":31,"text":178,"correct":22},"可燃性材料",{"key":60,"text":180,"correct":22},"易燃性材料","ACDE",{"id":183,"libraryId":5,"type":47,"typeLabel":48,"stem":184,"options":185,"answer":196,"analysis":33},1145338,"下列子分部工程，属于主体结构分部的有（ ）。",[186,188,190,192,194],{"key":20,"text":187,"correct":26},"混凝土基础",{"key":24,"text":189,"correct":22},"混凝土结构",{"key":28,"text":191,"correct":22},"砌体结构",{"key":31,"text":193,"correct":22},"钢结构",{"key":60,"text":195,"correct":26},"网架和索膜结构","BCD",{"id":198,"libraryId":5,"type":47,"typeLabel":48,"stem":199,"options":200,"answer":211,"analysis":33},1145339,"下列各项中，适用于管井降水的情况有（ ）。",[201,203,205,207,209],{"key":20,"text":202,"correct":26},"地表水",{"key":24,"text":204,"correct":22},"含水丰富的潜水",{"key":28,"text":206,"correct":22},"承压水",{"key":31,"text":208,"correct":26},"含水量不大的潜水",{"key":60,"text":210,"correct":26},"裂隙水","BC",{"id":213,"libraryId":5,"type":47,"typeLabel":48,"stem":214,"options":215,"answer":226,"analysis":33},1145340,"关于土钉墙施工构造的说法，正确的有（ ）。",[216,218,220,222,224],{"key":20,"text":217,"correct":22},"土钉的长度宜为开挖深度的0.5～1.2倍，间距宜为1～2m，与水平面夹角宜为5°～20°",{"key":24,"text":219,"correct":22},"土钉钢筋宜采用HRB400、HRB500级钢筋，钢筋直径宜为16~32mm,钻孔直径宜为70~120mm",{"key":28,"text":221,"correct":26},"注浆材料宜采用水泥浆或水泥砂浆，其强度等级不宜低于10MPa",{"key":31,"text":223,"correct":22},"喷射混凝土强度等级不宜低于C20，面层厚度不宜小于80mm",{"key":60,"text":225,"correct":26},"坡面上下段钢筋网搭接长度应大于200mm","ABD",{"id":228,"libraryId":5,"type":15,"typeLabel":16,"stem":229,"options":230,"answer":28,"analysis":33},1145341,"根据《建筑基坑支护技术规程》的规定，钢筋混凝土支撑构件的混凝土强度等级不应低于（ ）。",[231,233,235,237],{"key":20,"text":232,"correct":26},"C15",{"key":24,"text":234,"correct":26},"C20",{"key":28,"text":236,"correct":22},"C25",{"key":31,"text":238,"correct":26},"C10",{"id":240,"libraryId":5,"type":47,"typeLabel":48,"stem":241,"options":242,"answer":196,"analysis":33},1145342,"关于土钉墙设计及构造应符合的规定，说法正确的是（ ）。",[243,245,247,249,251],{"key":20,"text":244,"correct":26},"土钉墙墙面坡度不宜大于1：0.1",{"key":24,"text":246,"correct":22},"土钉的长度宜为开挖深度的0.5～1.2倍",{"key":28,"text":248,"correct":22},"土钉钢筋宜采用HRB400、HRB500级钢筋",{"key":31,"text":250,"correct":22},"注浆材料宜采用水泥浆或水泥砂浆，其强度等级不宜低于20MPa",{"key":60,"text":225,"correct":26},{"id":253,"libraryId":5,"type":47,"typeLabel":48,"stem":254,"options":255,"answer":226,"analysis":33},1145343,"关于土钉墙施工的说法，正确的有（ ）。",[256,257,259,261,262],{"key":20,"text":217,"correct":22},{"key":24,"text":258,"correct":22},"土钉钢筋宜采用Ⅱ、Ⅲ级钢筋，钢筋直径宜为16～32mm，钻孔直径宜为70～120mm",{"key":28,"text":260,"correct":26},"注浆材料宜采用水泥浆或水泥砂浆，其强度等级不宜低于M10",{"key":31,"text":223,"correct":22},{"key":60,"text":225,"correct":26},{"id":264,"libraryId":5,"type":15,"typeLabel":16,"stem":265,"options":266,"answer":31,"analysis":33},1145344,"下列土钉墙基坑支护的设计构造，错误的是（ ）。",[267,269,271,273],{"key":20,"text":268,"correct":26},"土钉墙墙面坡度1:0.2",{"key":24,"text":270,"correct":26},"土钉长度为开挖深度的0.8倍",{"key":28,"text":272,"correct":26},"土钉的间距2m",{"key":31,"text":274,"correct":22},"用强度等级为15MPa的水泥浆注浆",{"id":276,"libraryId":5,"type":47,"typeLabel":48,"stem":277,"options":278,"answer":289,"analysis":33},1145345,"适用于基坑侧壁安全等级为一级的支护形式有（ ）。",[279,281,283,285,287],{"key":20,"text":280,"correct":22},"排桩",{"key":24,"text":282,"correct":26},"逆作拱墙",{"key":28,"text":284,"correct":26},"土钉墙",{"key":31,"text":286,"correct":26},"水泥土墙",{"key":60,"text":288,"correct":22},"地下连续墙","AE",{"id":291,"libraryId":5,"type":47,"typeLabel":48,"stem":292,"options":293,"answer":62,"analysis":33},1145346,"关于排桩、地下连续墙的说法，正确的有（ ）。",[294,296,298,300,302],{"key":20,"text":295,"correct":22},"悬臂式排桩结构桩径不宜小于600mm",{"key":24,"text":297,"correct":22},"排桩与桩顶冠梁的混凝土强度等级宜大于C25",{"key":28,"text":299,"correct":22},"悬臂式现浇钢筋混凝土地下连续墙厚度不宜小于600mm",{"key":31,"text":301,"correct":26},"水下灌注混凝土地下连续墙混凝土强度等级为C15",{"key":60,"text":303,"correct":22},"桩锚体系中土层锚杆锚固段长度不宜小于6m",{"id":305,"libraryId":5,"type":47,"typeLabel":48,"stem":306,"options":307,"answer":315,"analysis":33},1145347,"深基坑的支护形式包括（ ）。",[308,310,311,313,314],{"key":20,"text":309,"correct":26},"斜拉支撑",{"key":24,"text":288,"correct":22},{"key":28,"text":312,"correct":26},"挡土灌注桩支护",{"key":31,"text":280,"correct":22},{"key":60,"text":286,"correct":22},"BDE",{"id":317,"libraryId":5,"type":47,"typeLabel":48,"stem":318,"options":319,"answer":196,"analysis":33},1145348,"适用注浆法进行处理的有（ ）。",[320,322,324,326,328],{"key":20,"text":321,"correct":26},"淤泥质土",{"key":24,"text":323,"correct":22},"人工填土",{"key":28,"text":325,"correct":22},"黏性土",{"key":31,"text":327,"correct":22},"砂土",{"key":60,"text":329,"correct":26},"碎石土",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":31,"analysis":33},1145349,"关于地基处理的做法，正确的是（ ）。",[334,336,338,340],{"key":20,"text":335,"correct":26},"砂石垫层是将基础底面下一定厚度软土层挖去，然后用强度较高的混凝土将挖去部分填充而成",{"key":24,"text":337,"correct":26},"强夯法适用含饱和水的软土或杂填土地基中",{"key":28,"text":339,"correct":26},"砂井预压堆载法是在杂填土集中处常用的一种地基处理方法",{"key":31,"text":341,"correct":22},"深层搅拌法利用水泥浆作固化剂，采用深层搅拌机在地基深部就地将软土和固化剂充分搅拌而成",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":28,"analysis":33},1145350,"关于砂石桩施工顺序，说法正确的是（ ）。",[346,348,350,352],{"key":20,"text":347,"correct":26},"对于砂土地基宜从中间向两侧进行",{"key":24,"text":349,"correct":26},"对黏性土地基宜从外围向中间进行",{"key":28,"text":351,"correct":22},"对黏性土地基宜从中间向外围或隔排施工",{"key":31,"text":353,"correct":26},"与既有建筑邻近施工时应采用隔排施工",{"id":355,"libraryId":5,"type":47,"typeLabel":48,"stem":356,"options":357,"answer":368,"analysis":33},1145351,"常用的地基处理技术有（ ）。",[358,360,362,364,366],{"key":20,"text":359,"correct":26},"灌注桩法",{"key":24,"text":361,"correct":22},"换填垫层法",{"key":28,"text":363,"correct":22},"堆载预压法",{"key":31,"text":365,"correct":22},"振冲法",{"key":60,"text":367,"correct":22},"砂桩挤密法","BCDE",{"id":370,"libraryId":5,"type":47,"typeLabel":48,"stem":371,"options":372,"answer":383,"analysis":33},1145352,"关于换填垫层材料选用，说法正确的有（ ）。",[373,375,377,379,381],{"key":20,"text":374,"correct":22},"当使用粉细砂时，应掺入不少于总重30%的碎石或卵石",{"key":24,"text":376,"correct":22},"选用粉质黏土时，土料中有机质含量不得超过5%；当含有碎石时，其粒径不宜大于50mm",{"key":28,"text":378,"correct":26},"选用灰土时，体积配合比宜为2:8或3:7，土料不宜用粉质黏土",{"key":31,"text":380,"correct":22},"选用粉煤灰时，粉煤灰垫层上宜覆土0.3～0.5m",{"key":60,"text":382,"correct":22},"选用矿渣时，矿渣的松散重度不小于11kN／m3，有机质及含泥总量不超过5%","ABDE",{"id":385,"libraryId":5,"type":15,"typeLabel":16,"stem":386,"options":387,"answer":28,"analysis":33},1145353,"地下工程穿墙管防水施工，其卷材加强层宽度不应小于（ ）。",[388,390,392,394],{"key":20,"text":389,"correct":26},"200mm",{"key":24,"text":391,"correct":26},"400mm",{"key":28,"text":393,"correct":22},"500mm",{"key":31,"text":395,"correct":26},"1000mm",{"id":397,"libraryId":5,"type":15,"typeLabel":16,"stem":398,"options":399,"answer":24,"analysis":33},1145354,"关于卷材防水施工，说法正确的是（ ）。",[400,402,404,406],{"key":20,"text":401,"correct":26},"冷粘法铺贴卷材时，接缝口密封材料封严宽度不应小于100mm",{"key":24,"text":403,"correct":22},"底板卷材防水层的细石混凝土保护层厚度应不小于50mm",{"key":28,"text":405,"correct":26},"两幅卷材短边和长边搭接宽度均不应小于80mm",{"key":31,"text":407,"correct":26},"多层卷材上下两层和相邻两幅卷材的接缝应错开200mm以上",{"id":409,"libraryId":5,"type":47,"typeLabel":48,"stem":410,"options":411,"answer":422,"analysis":33},1145355,"屋面高聚物改性沥青防水卷材的常用铺贴方法有（ ）。",[412,414,416,418,420],{"key":20,"text":413,"correct":22},"热熔法",{"key":24,"text":415,"correct":26},"热粘结剂法",{"key":28,"text":417,"correct":22},"冷粘法",{"key":31,"text":419,"correct":22},"自粘法",{"key":60,"text":421,"correct":26},"热风焊接法","ACD",{"id":424,"libraryId":5,"type":47,"typeLabel":48,"stem":425,"options":426,"answer":437,"analysis":33},1145356,"关于防水层施工环境气温条件，符合规范要求的有（ ）。",[427,429,431,433,435],{"key":20,"text":428,"correct":22},"四级大风时施工地下防水工程的防水层",{"key":24,"text":430,"correct":26},"0℃气温条件下，施工防水混凝土",{"key":28,"text":432,"correct":26},"0℃气温条件下，施工无机防水涂料",{"key":31,"text":434,"correct":22},"-5℃气温条件下，施工膨润土防水涂料",{"key":60,"text":436,"correct":22},"-5℃气温条件下，热熔法施工高聚物改性沥青防水卷材","ADE",{"id":439,"libraryId":5,"type":15,"typeLabel":16,"stem":440,"options":441,"answer":28,"analysis":33},1145357,"土方开挖前应检查的是（ ）。",[442,444,446,448],{"key":20,"text":443,"correct":26},"定位放线、周围环境和降低地下水位系统",{"key":24,"text":445,"correct":26},"定位放线、压实度和周围环境",{"key":28,"text":447,"correct":22},"定位放线，排水和地下水控制系统，以及对周边影响范围内地下管线和建（构）筑物保护措施的落实",{"key":31,"text":449,"correct":26},"定位放线、运输路线和排水降水系统",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":24,"analysis":33},1145358,"基坑土方开挖的顺序、方法必须与设计要求相一致，并遵循“开槽支撑，（ ），严禁超挖”的原则。",[454,456,458,460],{"key":20,"text":455,"correct":26},"先撑后挖，整体开挖",{"key":24,"text":457,"correct":22},"先撑后挖，分层开挖",{"key":28,"text":459,"correct":26},"先挖后撑，整体开挖",{"key":31,"text":461,"correct":26},"先挖后撑，分层开挖",{"id":463,"libraryId":5,"type":47,"typeLabel":48,"stem":464,"options":465,"answer":368,"analysis":33},1145359,"灰土地基、砂和砂石地基在施工过程中应检查的项目有（ ）。",[466,468,470,472,474],{"key":20,"text":467,"correct":26},"总铺设厚度",{"key":24,"text":469,"correct":22},"分段施工时搭接部分的夯实情况",{"key":28,"text":471,"correct":22},"加水量",{"key":31,"text":473,"correct":22},"压实遍数",{"key":60,"text":475,"correct":22},"压实系数",{"id":477,"libraryId":5,"type":47,"typeLabel":48,"stem":478,"options":479,"answer":490,"analysis":33},1145360,"水泥土搅拌桩施工结束后应检查的项目有（ ）。",[480,482,484,486,488],{"key":20,"text":481,"correct":22},"桩体强度",{"key":24,"text":483,"correct":22},"桩体直径",{"key":28,"text":485,"correct":22},"地基承载力",{"key":31,"text":487,"correct":26},"桩体长度",{"key":60,"text":489,"correct":26},"桩体标高","ABC",{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":20,"analysis":33},1145362,"属于外围护系统现场实验和测试的项目是（ ）",[495,497,499,501],{"key":20,"text":496,"correct":22},"饰面砖（板）的粘结强度测试",{"key":24,"text":498,"correct":26},"层间变形性能",{"key":28,"text":500,"correct":26},"耐撞击性能",{"key":31,"text":502,"correct":26},"耐火极限",{"id":504,"libraryId":5,"type":47,"typeLabel":48,"stem":505,"options":506,"answer":383,"analysis":33},1145363,"外围护部品应完成的现场隐蔽项目验收有（ ）。",[507,509,511,512,514],{"key":20,"text":508,"correct":22},"预埋件",{"key":24,"text":510,"correct":22},"与主体结构的连接节点",{"key":28,"text":498,"correct":26},{"key":31,"text":513,"correct":22},"变形缝及墙面转角处的构造节点",{"key":60,"text":515,"correct":22},"防火构造",{"id":517,"libraryId":5,"type":47,"typeLabel":48,"stem":518,"options":519,"answer":530,"analysis":33},1145364,"梁板类简支受弯预制构件进场时，对大型构件及有可靠应用经验的构件，可只进行（ ）检验。",[520,522,524,526,528],{"key":20,"text":521,"correct":22},"裂缝宽度",{"key":24,"text":523,"correct":22},"抗裂",{"key":28,"text":525,"correct":26},"承载力",{"key":31,"text":527,"correct":26},"混凝土强度",{"key":60,"text":529,"correct":22},"挠度","ABE",{"id":532,"libraryId":5,"type":15,"typeLabel":16,"stem":533,"options":534,"answer":31,"analysis":33},1145365,"装配式建筑施工时，同一厂家（ ）生产的材料、部品，用于（ ）施工且属于同一工程项目的多个单位工程，可（ ）进行进场验收。",[535,537,539,541],{"key":20,"text":536,"correct":26},"分批同期合并",{"key":24,"text":538,"correct":26},"同批分期合并",{"key":28,"text":540,"correct":26},"分批分期合并",{"key":31,"text":542,"correct":22},"同批同期合并",{"id":544,"libraryId":5,"type":47,"typeLabel":48,"stem":545,"options":546,"answer":557,"analysis":33},1145366,"钢结构涂装工程中，防腐涂料的涂料、涂装遍数、涂层厚度应符合设计要求，当设计对涂层厚度无要求时，涂层干漆膜应满足（ ）。",[547,549,551,553,555],{"key":20,"text":548,"correct":22},"总厚度室外应为150μm",{"key":24,"text":550,"correct":26},"总厚度室外可为125μm",{"key":28,"text":552,"correct":22},"总厚度室内应为125μm",{"key":31,"text":554,"correct":26},"每遍厚度允许偏差为-5μm",{"key":60,"text":556,"correct":26},"每遍厚度允许偏差为±5μm","AC",{"id":559,"libraryId":5,"type":15,"typeLabel":16,"stem":560,"options":561,"answer":28,"analysis":33},1145367,"钢结构组装时，顶紧接触面紧贴面积最小限值是（ ）。",[562,564,566,568],{"key":20,"text":563,"correct":26},"50%",{"key":24,"text":565,"correct":26},"60%",{"key":28,"text":567,"correct":22},"75%",{"key":31,"text":569,"correct":26},"70%",{"id":571,"libraryId":5,"type":15,"typeLabel":16,"stem":572,"options":573,"answer":28,"analysis":33},1145368,"桁架结构杆件轴线交点错位的允许偏差最大限值是（ ）mm。",[574,576,578,580],{"key":20,"text":575,"correct":26},"1",{"key":24,"text":577,"correct":26},"2",{"key":28,"text":579,"correct":22},"3",{"key":31,"text":581,"correct":26},"4",{"id":583,"libraryId":5,"type":15,"typeLabel":16,"stem":584,"options":585,"answer":24,"analysis":33},1145369,"关于多层及高层钢结构安装工程的说法，正确的是（ ）。",[586,588,590,592],{"key":20,"text":587,"correct":26},"所有构件的中心线及标高基准点等标记必须齐全",{"key":24,"text":589,"correct":22},"结构楼层标高可以按相对标高进行控制",{"key":28,"text":591,"correct":26},"上层柱的定位轴线可从下层柱的轴线引上",{"key":31,"text":593,"correct":26},"柱、梁、支撑等构件的长度尺寸应等于构件的设计长度尺寸，偏差控制在允许范围之内",{"id":595,"libraryId":5,"type":47,"typeLabel":48,"stem":596,"options":597,"answer":608,"analysis":33},1145370,"单层钢结构安装工程中，不得在其上焊接悬挂物和卡具的构件有（ ）。",[598,600,602,604,606],{"key":20,"text":599,"correct":22},"吊车梁受拉翼缘",{"key":24,"text":601,"correct":22},"直接承受动力荷载的梁受拉翼缘",{"key":28,"text":603,"correct":22},"吊车桁架受拉弦杆",{"key":31,"text":605,"correct":22},"直接承受动力荷载的桁架受拉弦杆",{"key":60,"text":607,"correct":26},"主梁受拉翼缘","ABCD",{"id":610,"libraryId":5,"type":15,"typeLabel":16,"stem":611,"options":612,"answer":24,"analysis":33},1145371,"对于多层及高层钢结构安装工程的说法，正确的是（ ）。",[613,614,615,616],{"key":20,"text":587,"correct":26},{"key":24,"text":589,"correct":22},{"key":28,"text":591,"correct":26},{"key":31,"text":593,"correct":26},{"id":618,"libraryId":5,"type":15,"typeLabel":16,"stem":619,"options":620,"answer":20,"analysis":33},1145372,"关于高强度螺栓终拧后螺栓丝扣外露的说法，正确的是（ ）。",[621,623,625,627],{"key":20,"text":622,"correct":22},"丝扣外露为2～3扣，其中允许有10%的螺栓丝扣外露1扣或4扣",{"key":24,"text":624,"correct":26},"丝扣外露为2～3扣，其中允许有20%的螺栓丝扣外露1扣或4扣",{"key":28,"text":626,"correct":26},"丝扣外露为3～4扣，其中允许有10%的螺栓丝扣外露1扣或4扣",{"key":31,"text":628,"correct":26},"丝扣外露为3～4扣，其中允许有20%的螺栓丝扣外露1扣或4扣",{"id":630,"libraryId":5,"type":15,"typeLabel":16,"stem":631,"options":632,"answer":24,"analysis":33},1145373,"永久性普通螺栓紧固应牢固、可靠，丝扣外露最小限值是（ ）扣。",[633,634,635,636],{"key":20,"text":575,"correct":26},{"key":24,"text":577,"correct":22},{"key":28,"text":579,"correct":26},{"key":31,"text":581,"correct":26},{"id":638,"libraryId":5,"type":15,"typeLabel":16,"stem":639,"options":640,"answer":20,"analysis":33},1145374,"普通螺栓作为永久性连接螺栓时，当设计有要求或对其质量有疑义时，应进行螺栓实物复验指标是（ ）。",[641,643,645,647],{"key":20,"text":642,"correct":22},"最小拉力荷载",{"key":24,"text":644,"correct":26},"摩擦面抗滑移系数",{"key":28,"text":646,"correct":26},"紧固轴力",{"key":31,"text":648,"correct":26},"预拉力",[650,653,656,659,662,665],{"id":15,"name":651,"category":7,"favorite":652},"领导干部任职前廉政法规知识测试题",92,{"id":654,"name":655,"category":7,"favorite":15},595,"建筑结构与设备",{"id":657,"name":658,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":660,"name":661,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":663,"name":664,"category":7,"favorite":8},534,"BIM工程师",{"id":666,"name":664,"category":7,"favorite":8},535]