[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1145608":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1145608,800,2,"多选题","大体积混凝土施工过程中，减少或防止出现裂缝的技术措施有()。2014年",[11,15,18,21,25],{"key":12,"text":13,"correct":14},"A","二次振捣",true,{"key":16,"text":17,"correct":14},"B","二次表面抹压",{"key":19,"text":20,"correct":14},"C","控制混凝土内部温度的降温速率",{"key":22,"text":23,"correct":24},"D","尽快降低混凝土表面温度",false,{"key":26,"text":27,"correct":14},"E","保温保湿养护","ABCE","大体积混凝土防裂宜采取以保温、保湿养护为主体，抗放兼施为主导的大体积混凝土温控措施。大体积混凝土工程施工前，宜对施工阶段大体积混凝土浇筑体的温度、温度应力及收缩应力进行试算，并确定施工阶段大体积混凝土浇筑体的升温峰值，里表温差及降温速率的控制指标，制定相应的温控技术措施。大体积混凝土浇筑宜采用二次振捣工艺，浇筑面应及时进行二次抹压处理，减少表面收缩裂缝。@##",{"id":6,"name":31,"category":32,"favorite":33},"一建建筑工程实务","建筑工程",0]