[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1145430":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1145430,800,2,"多选题","对屋面工程细部构造的质量验收，下列说法中正确的是（ ）。",[11,15,18,22,25],{"key":12,"text":13,"correct":14},"A","铺贴檐口800mm范围内的卷材应采取满粘法",true,{"key":16,"text":17,"correct":14},"B","防水层伸入水落口杯内不应小于50mm",{"key":19,"text":20,"correct":21},"C","变形缝的泛水高度不应小于300mm",false,{"key":23,"text":24,"correct":14},"D","伸出屋面管道的泛水高度及附加层铺，其周围的找平层应抹出髙度不小于30mm的排水坡",{"key":26,"text":27,"correct":21},"E","沟内附加层在天沟、檐沟与屋面交接处宜空铺，空铺的宽度不应小于250mm","ABD","2020教材P412 \u002F 2019教材P413 （3）檐口800m m范围内的卷材应满粘，檐口端部应抹聚合物水泥砂浆，其下端应做成鹰嘴或滴水槽。 （6）防水层和附加层伸入水落口杯内不应小于50m m，并应粘结牢固。 （8）伸出屋面管道的泛水高度及附加层铺设，应符合设计要求。其周围的找平层应抹出髙度不小于30m m的排水坡。",{"id":6,"name":31,"category":32,"favorite":33},"一建建筑工程实务","建筑工程",0]