[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1145347":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1145347,800,2,"多选题","深基坑的支护形式包括（ ）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","斜拉支撑",false,{"key":16,"text":17,"correct":18},"B","地下连续墙",true,{"key":20,"text":21,"correct":14},"C","挡土灌注桩支护",{"key":23,"text":24,"correct":18},"D","排桩",{"key":26,"text":27,"correct":18},"E","水泥土墙","BDE","2020教材P393 \u002F 2019教材P394 （1）排桩支护适用条件：基坑侧壁安全等级为一级、二级、三级；适用于可采取降水或止水帷幕的基坑。（2）地下连续墙适用条件：基坑侧壁安全等级为一级、二级、三级；适用于周边环境条件复杂的深基坑。（3）水泥土桩墙适用条件：基坑侧壁安全等级宜为二、三级；水泥土桩施工范围内地基土承载力不宜大于150kPa;基坑深度不宜大于6m。（4）逆作拱墙适用条件：基坑侧壁安全等级宜为三级；淤泥和淤泥质土场地不宜采用；拱墙轴线的矢跨比不宜小于1\u002F8;基坑深度不宜大于12m;地下水位高于基坑底面时，应采取降水或截水措施。",{"id":6,"name":31,"category":32,"favorite":33},"一建建筑工程实务","建筑工程",0]