[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1145346":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1145346,800,2,"多选题","关于排桩、地下连续墙的说法，正确的有（ ）。",[11,15,18,21,25],{"key":12,"text":13,"correct":14},"A","悬臂式排桩结构桩径不宜小于600mm",true,{"key":16,"text":17,"correct":14},"B","排桩与桩顶冠梁的混凝土强度等级宜大于C25",{"key":19,"text":20,"correct":14},"C","悬臂式现浇钢筋混凝土地下连续墙厚度不宜小于600mm",{"key":22,"text":23,"correct":24},"D","水下灌注混凝土地下连续墙混凝土强度等级为C15",false,{"key":26,"text":27,"correct":14},"E","桩锚体系中土层锚杆锚固段长度不宜小于6m","ABCE","2020教材P393 \u002F 2019教材P394 排粧、地下连续墙（1）悬臂式排桩结构桩径不宜小于600mm，桩间距应根据排桩受力及桩间土稳定条件确定。（2）排桩顶部应设钢筋混凝土冠梁连接，冠梁宽度水平方向不宜小于桩径，冠梁高度竖直方向不宜小于梁宽0.6倍。排桩与粧顶冠梁的混凝土强度等级宜大于C25;当冠梁作为连系梁时可按构造配筋。（4）悬臂式现浇钢筋混凝土地下连续墙厚度不宜小于600mm，地下连续墙顶部应设置钢筋混凝土冠梁，冠梁宽度不宜小于地下连续墙厚度，高度不宜小于墙厚0.6倍。（5）水下灌注混凝土地下连续墙混凝土强度等级宜取C30—C40，地下连续墙作为地下室外墙时还应满足抗渗要求。（6）锚杆长度设计应符合下列规定：2）土层锚杆锚固段长度不宜小于6m;",{"id":6,"name":31,"category":32,"favorite":33},"一建建筑工程实务","建筑工程",0]