[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1145343":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1145343,800,2,"多选题","关于土钉墙施工的说法，正确的有（ ）。",[11,15,18,22,25],{"key":12,"text":13,"correct":14},"A","土钉的长度宜为开挖深度的0.5～1.2倍，间距宜为1～2m，与水平面夹角宜为5°～20°",true,{"key":16,"text":17,"correct":14},"B","土钉钢筋宜采用Ⅱ、Ⅲ级钢筋，钢筋直径宜为16～32mm，钻孔直径宜为70～120mm",{"key":19,"text":20,"correct":21},"C","注浆材料宜采用水泥浆或水泥砂浆，其强度等级不宜低于M10",false,{"key":23,"text":24,"correct":14},"D","喷射混凝土强度等级不宜低于C20，面层厚度不宜小于80mm",{"key":26,"text":27,"correct":21},"E","坡面上下段钢筋网搭接长度应大于200mm","ABD","2020教材P394 \u002F 2019教材P395 （1）土钉墙设计及构造应符合下列规定： 1）土钉墙墙面坡度不宜大于1:0.2; 2）土钉必须和面层有效连接，应设置承压板或加强钢筋等构造措施，承压板或加强钢筋应与土钉螺栓连接或钢筋焊接连接； 3）土钉的长度宜为开挖深度的0.5~1.2倍，间距宜为1~2 m，与水平面夹角宜为5°~20°； 4）土钉钢筋宜采用HRB400、HRB500级钢筋，钢筋直径宜为16~32mm钻孔直径宜为70~120mm; 5）注浆材料宜采用水泥浆或水泥砂浆，其强度等级不宜低于20MPa 6）喷射混凝土面层宜配置钢筋网，钢筋直径宜为6~1 0 m m，间距宜为150~300mm；喷射混凝土强度等级不宜低于C20，面层厚度不宜小于80m m; 7）坡面上下段钢筋网搭接长度应大于300mm。 （2）当地下水位高于基坑底面时，应采取降水或截水措施；土钉墙墙顶应采用砂浆或混凝土护面，坡顶和坡脚应设排水措施，坡面上可根据具体情况设置泄水孔。",{"id":6,"name":31,"category":32,"favorite":33},"一建建筑工程实务","建筑工程",0]