[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1145025":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1145025,800,2,"多选题","关于屋面、厕浴间防水工程蓄水试验的说法，正确的有（ ）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","屋面在雨后或持续淋水2h后或蓄水时间不应少于24h",true,{"key":16,"text":17,"correct":18},"B","屋面在雨后或持续淋水2h后或蓄水时间不应少于12h",false,{"key":20,"text":21,"correct":14},"C","厨房、厕浴间做24h蓄水试验",{"key":23,"text":24,"correct":18},"D","厨房、厕浴间做12h蓄水试验",{"key":26,"text":27,"correct":14},"E","墙面间歇淋水试验应达到30min以上不渗漏。","ACE","2020教材P229 \u002F 2019教材P231 （二）屋面防水工程：防水层完工后，应在雨后或持续淋水2h后（有可能作蓄水检验的屋面，其蓄水时间不应少于24h）（三）厨房、厕浴间防水工程厨房、厕浴间防水层完成后，应做24h蓄水试验，确认无渗漏时再做保护层和面层。设备与饰面层施工完后还应在其上继续做第二次24h蓄水试验，达到最终无渗漏和排水畅通为合格，方可进行正式验收。墙面间歇淋水试验应达到30min以上不渗漏。",{"id":6,"name":31,"category":32,"favorite":33},"一建建筑工程实务","建筑工程",0]