[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1144786":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1144786,800,2,"多选题","关于建筑幕墙防火技术要点的说法，正确的有（ ）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","幕墙与各层楼板、隔墙外沿间的缝隙，填充材料可采用岩棉或矿棉",true,{"key":16,"text":17,"correct":18},"B","防火层应采用厚度不小于1.0mm的镀锌钢板承托",false,{"key":20,"text":21,"correct":14},"C","承托板与主体结构、幕墙结构及承托板之间的缝隙应采用防火密封胶密封",{"key":23,"text":24,"correct":14},"D","防火层不应与玻璃直接接触，防火材料朝玻璃面处宜采用装饰材料覆盖",{"key":26,"text":27,"correct":14},"E","同一幕墙玻璃单元不应跨越两个防火分区","ACDE","2020教材P164 \u002F 2019教材P166 （1） 幕墙与各层楼板、隔墙外沿间的缝隙，应采用不燃材料封堵，填充材料可采用岩棉或矿棉，其厚度不应小于 100mm 并应满足设计的耐火极限要求，在楼层间形成水平防火烟带。防火层应采用厚度不小于 1.5mm 的镀锌钢板承托，不得采用铝板。 承托板与主体结构、幕墙结构及承托板之间的缝隙应采用防火密封胶密封。防火密封胶应有法定检测机构的防火检验报告",{"id":6,"name":31,"category":32,"favorite":33},"一建建筑工程实务","建筑工程",0]