[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1144665":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1144665,800,2,"多选题","下列关于防水混凝土施工缝留置技术要求的说法中，正确的有（ ）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","墙体水平施工缝不应留在剪力最大处，应留在高出底板表面不小于500mm的墙体上",false,{"key":16,"text":17,"correct":18},"B","拱（板）墙结合的水平施工缝，宜留在拱（板）墙接缝线以下150～300mm处",true,{"key":20,"text":21,"correct":18},"C","墙体有预留孔洞时，施工缝距孔洞边缘不应小于300mm",{"key":23,"text":24,"correct":18},"D","垂直施工缝应避开地下水和裂隙水较多的地段，并宜与变形缝相结合",{"key":26,"text":27,"correct":14},"E","墙体水平施工缝不应留在剪力底板与侧墙的交接处，应留在高出底板表面不小于500mm的墙体上","BCD","2020教材P133 \u002F 2019教材P132 （6） 防水混凝土应连续浇筑，宜少留施工缝。当留设施工缝时，应符合下列规定： 1） 墙体水平施工缝不应留在剪力最大处或底板与侧墙的交接处，应留在高出底板表面不小于300mm 的墙体上。拱（板）墙结合的水平施工缝，宜留在拱（板）墙接缝线以下150 ~ 300mm 处。墙体有预留孔洞时，施工缝距孔洞边缘不应小于300mm； 2） 垂直施工缝应避开地下水和裂隙水较多的地段，并宜与变形缝相结合。",{"id":6,"name":31,"category":32,"favorite":33},"一建建筑工程实务","建筑工程",0]