[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1144591":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1144591,800,2,"多选题","关于砌体直槎处拉结钢筋的说法，以下正确的是（ ）。",[11,15,18,22,25],{"key":12,"text":13,"correct":14},"A","非抗震设防及抗震设防烈度为6度、7度地区的临时间断处，当不能留置斜槎时，除转角处外，可留直槎，但直槎必须做成凸槎",true,{"key":16,"text":17,"correct":14},"B","120mm墙厚应放置2①6的拉结钢筋",{"key":19,"text":20,"correct":21},"C","间距沿墙高不应超过600mm",false,{"key":23,"text":24,"correct":14},"D","抗震设防6度、7度地区，埋入长度从留槎处算起每边均不应小于1000mm",{"key":26,"text":27,"correct":21},"E","末端应有180°弯钩","ABD","2020教材P116 \u002F 2019教材P115 （12）非抗震设防及抗震设防烈度为6度、7度地区的临时间断处，当不能留斜槎时，除转角处外，可留直槎，但直槎必须做成凸槎。留直槎处应加设拉结筋，拉结钢筋的数量为每120mm墙厚应放置1Φ6拉结钢筋（120mm厚墙应放置2Φ6拉结钢筋），间距沿墙高不应超过500mm，且竖向间距偏差不应超过100mm；埋入长度从留槎处算起每边均不应小于500mm，对抗震设防烈度6度、7度地区，不应小于1000mm；末端应有90°弯钩。",{"id":6,"name":31,"category":32,"favorite":33},"一建建筑工程实务","建筑工程",0]